Question 90
At a telecommunications exchange in Dallas, a primary firewall must fail over to a synchronized peer during an appliance shutdown. The change affects voice services. What outcome directly proves this configuration works?
Explanation
Correct Answer
At a telecommunications exchange in Dallas, this verifies the specific active/passive ha requirement rather than merely recording an intended configuration: The passive peer takes over after the active unit is isolated and allowed traffic resumes through the surviving unit. The associated implementation is: configure active/passive HA with working HA1/HA2 paths and configuration synchronization.
Incorrect Answers
The offered observation would confirm the separate intervention: Resolve the documented HA compatibility and synchronization prerequisites before testing failover. It measures: HA status shows synchronized peers and compatible software/content state without synchronization alarms. The current active/passive ha configuration is Configure active/passive HA with working HA1/HA2 paths and configuration synchronization, and must demonstrate: The passive peer takes over after the active unit is isolated and allowed traffic resumes through the surviving unit. The two acceptance checks are not interchangeable even though they share a feature area.
That observation measures link and path monitoring after this other intervention: Configure HA link monitoring for the business-critical uplink with an appropriate failure response. Its result is: Disconnecting that uplink produces the expected HA event and moves service to the healthy peer. The requested active/passive ha change is Configure active/passive HA with working HA1/HA2 paths and configuration synchronization, which must demonstrate: The passive peer takes over after the active unit is isolated and allowed traffic resumes through the surviving unit. The offered evidence does not validate the specified control.
The offered observation would confirm the separate intervention: Provide the required HA data synchronization interface/path for the selected platform and mode. It measures: Session sync indicators are healthy and established permitted traffic survives the supported failover test. The current active/passive ha configuration is Configure active/passive HA with working HA1/HA2 paths and configuration synchronization, and must demonstrate: The passive peer takes over after the active unit is isolated and allowed traffic resumes through the surviving unit. The two acceptance checks are not interchangeable even though they share a feature area.