McAfee-Secured Website

Exam Bundle

Exam Code: SK0-005

Exam Name CompTIA Server+ Certification Exam

Certification Provider: CompTIA

Corresponding Certification: CompTIA Server+

CompTIA SK0-005 Bundle $44.99

100% CompTIA SK0-005 Guaranteed Success With Testking Training Materials

Get Real SK0-005 Exam Questions & Expert Verified Answers as Experienced on the Real Exam!

  • Questions & Answers

    SK0-005 Questions & Answers

    617 Questions & Answers

    The ultimate exam preparation tool, Questions & Answers mirrors the actual SK0-005 exam while allowing you to hone and measure every aspect of your test-taking ability.

  • SK0-005 Video Course

    SK0-005 Video Course

    139 Video Lectures

    SK0-005 Video Course is developed by CompTIA Professionals to help you pass the SK0-005 exam.

    Description

    This course will improve your knowledge and skills required to pass CompTIA Server+ Certification Exam exam.
  • Study Guide

    SK0-005 Study Guide

    533 PDF Pages

    Developed by industry experts, this 533-page guide spells out in painstaking detail all of the information you need to ace SK0-005 exam.

CompTIA Server+ Certification Exam (SK0-005) Practice Tests

Satisfaction Guaranteed

Money Back Guarantee

Testking provides hassle-free money back guarantee with our products. That is because we have 100% trust in the abilities of our professional and experience product team, and our record is a proof of that.

99.6% PASS RATE
Total Cost: $194.97
Bundle Price: $149.98

Purchase Individually

  • Questions & Answers

    Questions & Answers

    617 Questions

    $124.99
  • SK0-005 Video Course

    Video Course

    139 Video Lectures

    $39.99
  • Study Guide

    Study Guide

    533 PDF Pages

    $29.99

CompTIA SK0-005 Practice Test 96

Question 950

A server operations team encounters the following situation: A storage chassis reports all eight disks unavailable at once after a backplane power cable was disturbed during maintenance. After making the corrective change, which result best demonstrates that this particular problem is resolved?

  1. Replacing the indicated fan clears the active fault and normalizes RPM.
  2. Memory error counters stop increasing and stress testing completes without crashes.
  3. All eight expected physical disks reappear without unnecessary replacements.
  4. Fan RPM and temperature remain within spec under representative load.

Explanation

Correct Answer

C:

This is incident-specific acceptance evidence: All eight expected physical disks reappear without unnecessary replacements. It verifies the action check shared backplane power and connectors before replacing individual drives. The failure under test was: Simultaneous failures across multiple drives point to a shared backplane or power path.

Incorrect Answers

A:

This observation tests an unrelated Given a scenario, troubleshoot common hardware failures case: A server's chassis LED flags a failed redundant fan, but engineers replace its disk controller based only on unrelated historical alerts. It may be true while the current failure persists; the decisive current cause is: Simultaneous failures across multiple drives point to a shared backplane or power path.

B:

This observation tests an unrelated Given a scenario, troubleshoot common hardware failures case: A compute server produces repeated uncorrectable ECC memory errors followed by kernel panics, while its processor temperatures remain normal. It may be true while the current failure persists; the decisive current cause is: Simultaneous failures across multiple drives point to a shared backplane or power path.

D:

This observation tests an unrelated Given a scenario, troubleshoot common hardware failures case: A server sounds a fan alarm and CPU temperature rises to its throttling threshold after a replacement fan was connected to the wrong header. It may be true while the current failure persists; the decisive current cause is: Simultaneous failures across multiple drives point to a shared backplane or power path.

Question 951

A server operations team encounters the following situation: A storage chassis reports all eight disks unavailable at once after a backplane power cable was disturbed during maintenance. Which underlying cause most specifically explains the observed symptoms?

  1. A weak battery fails to preserve persistent real-time clock and firmware values.
  2. Platform firmware and controller firmware are incompatible.
  3. Historical unrelated alerts are being mistaken for current fault evidence.
  4. Simultaneous failures across multiple drives point to a shared backplane or power path.

Explanation

Correct Answer

D:

This root-cause explanation directly accounts for the reported condition: A storage chassis reports all eight disks unavailable at once after a backplane power cable was disturbed during maintenance. The corrective step is: Check shared backplane power and connectors before replacing individual drives. The verifying outcome is: All eight expected physical disks reappear without unnecessary replacements.

Incorrect Answers

A:

This alternative cause would explain a different case: A server loses time and boot order whenever rack power is fully isolated, though it behaves normally across OS-only reboots. It does not explain the actual incident's evidence. The present cause is: Simultaneous failures across multiple drives point to a shared backplane or power path.

B:

This alternative cause would explain a different case: A server stops passing POST after a firmware change, and management logs identify an unsupported revision for its RAID adapter. It does not explain the actual incident's evidence. The present cause is: Simultaneous failures across multiple drives point to a shared backplane or power path.

C:

This alternative cause would explain a different case: A server's chassis LED flags a failed redundant fan, but engineers replace its disk controller based only on unrelated historical alerts. It does not explain the actual incident's evidence. The present cause is: Simultaneous failures across multiple drives point to a shared backplane or power path.

Question 952

A server operations team encounters the following situation: A storage chassis reports all eight disks unavailable at once after a backplane power cable was disturbed during maintenance. Which sustained operational control best reduces the likelihood of this same issue recurring?

  1. Inspect shared connectors after internal chassis service.
  2. Check chassis clearances during rack cable and panel maintenance.
  3. Monitor per-supply health and rack electrical headroom.
  4. Cross-check DIMM speed, rank and placement against vendor HCLs.

Explanation

Correct Answer

A:

This control targets the underlying recurrence risk: Simultaneous failures across multiple drives point to a shared backplane or power path. It builds validation into the affected workflow and supports the expected recovery result: All eight expected physical disks reappear without unnecessary replacements.

Incorrect Answers

B:

This control addresses a different scenario: A rack has proper ambient temperature but a specific node overheats after someone places a blanking cover across its rear exhaust. That event's root mechanism was local blocked exhaust can overheat a server even with adequate facility cooling. The described incident instead arises from: Simultaneous failures across multiple drives point to a shared backplane or power path.

C:

This control addresses a different scenario: A virtualization host suddenly powers off during peak usage, while PSU telemetry shows overload and a degraded redundant supply. That event's root mechanism was insufficient remaining power supply capacity leads to shutdown. The described incident instead arises from: Simultaneous failures across multiple drives point to a shared backplane or power path.

D:

This control addresses a different scenario: A rack server emits repeated POST beep codes and never initializes video after a technician installs unsupported memory DIMMs. That event's root mechanism was unsupported or misconfigured memory prevents hardware initialization. The described incident instead arises from: Simultaneous failures across multiple drives point to a shared backplane or power path.

Question 953

A server operations team encounters the following situation: A server's chassis LED flags a failed redundant fan, but engineers replace its disk controller based only on unrelated historical alerts. Given the stated symptoms and constraints, which corrective action is the best next step?

  1. Use vendor diagnostics to isolate and replace the failed memory module or channel.
  2. Restore the approved airflow path and retest the GPU cooling system.
  3. Use current component sensors and LED fault mapping to confirm the affected fan.
  4. Diagnose the affected PCIe path, firmware and supported card compatibility.

Explanation

Correct Answer

C:

The preferred corrective action directly addresses the incident: A server's chassis LED flags a failed redundant fan, but engineers replace its disk controller based only on unrelated historical alerts. The fault mechanism is historical unrelated alerts are being mistaken for current fault evidence. Expected confirmation is: Replacing the indicated fan clears the active fault and normalizes RPM.

Incorrect Answers

A:

This action is better suited to a separate Given a scenario, troubleshoot common hardware failures incident: A compute server produces repeated uncorrectable ECC memory errors followed by kernel panics, while its processor temperatures remain normal. That case involves: Uncorrectable RAM faults can cause host crashes independently of thermal conditions. Here the observed mechanism is instead: Historical unrelated alerts are being mistaken for current fault evidence. Applying the other repair would not directly resolve this fault.

B:

This action is better suited to a separate Given a scenario, troubleshoot common hardware failures incident: A blade's host crashes when its GPU workload starts, but temperature logs reveal rapid GPU overheating and an obstructed air duct. That case involves: The workload exposes insufficient GPU cooling rather than an application-only defect. Here the observed mechanism is instead: Historical unrelated alerts are being mistaken for current fault evidence. Applying the other repair would not directly resolve this fault.

D:

This action is better suited to a separate Given a scenario, troubleshoot common hardware failures incident: A compute node freezes only when a high-speed NIC transfers data; vendor logs show repeated corrected PCIe bus errors. That case involves: PCIe signal or firmware instability appears under traffic load. Here the observed mechanism is instead: Historical unrelated alerts are being mistaken for current fault evidence. Applying the other repair would not directly resolve this fault.

Question 954

A server operations team encounters the following situation: A server's chassis LED flags a failed redundant fan, but engineers replace its disk controller based only on unrelated historical alerts. After making the corrective change, which result best demonstrates that this particular problem is resolved?

  1. A CPU stress test shows stable temperatures and no spontaneous shutdown.
  2. POST identifies the processor and passes platform diagnostics.
  3. Fan RPM and temperature remain within spec under representative load.
  4. Replacing the indicated fan clears the active fault and normalizes RPM.

Explanation

Correct Answer

D:

This is incident-specific acceptance evidence: Replacing the indicated fan clears the active fault and normalizes RPM. It verifies the action use current component sensors and LED fault mapping to confirm the affected fan. The failure under test was: Historical unrelated alerts are being mistaken for current fault evidence.

Incorrect Answers

A:

This observation tests an unrelated Given a scenario, troubleshoot common hardware failures case: A new CPU cooler has a loose mounting bracket, and server logs show intermittent overheating and unexplained kernel crashes. It may be true while the current failure persists; the decisive current cause is: Historical unrelated alerts are being mistaken for current fault evidence.

B:

This observation tests an unrelated Given a scenario, troubleshoot common hardware failures case: A four-CPU node continues displaying hardware faults after a processor replacement because its BIOS version does not recognize the new CPU stepping. It may be true while the current failure persists; the decisive current cause is: Historical unrelated alerts are being mistaken for current fault evidence.

C:

This observation tests an unrelated Given a scenario, troubleshoot common hardware failures case: A server sounds a fan alarm and CPU temperature rises to its throttling threshold after a replacement fan was connected to the wrong header. It may be true while the current failure persists; the decisive current cause is: Historical unrelated alerts are being mistaken for current fault evidence.

Question 955

A server operations team encounters the following situation: A server's chassis LED flags a failed redundant fan, but engineers replace its disk controller based only on unrelated historical alerts. Which underlying cause most specifically explains the observed symptoms?

  1. Historical unrelated alerts are being mistaken for current fault evidence.
  2. Processor revision compatibility depends on firmware support.
  3. Insufficient remaining power supply capacity leads to shutdown.
  4. Improper cooling fan placement reduces effective processor airflow.

Explanation

Correct Answer

A:

This root-cause explanation directly accounts for the reported condition: A server's chassis LED flags a failed redundant fan, but engineers replace its disk controller based only on unrelated historical alerts. The corrective step is: Use current component sensors and LED fault mapping to confirm the affected fan. The verifying outcome is: Replacing the indicated fan clears the active fault and normalizes RPM.

Incorrect Answers

B:

This alternative cause would explain a different case: A four-CPU node continues displaying hardware faults after a processor replacement because its BIOS version does not recognize the new CPU stepping. It does not explain the actual incident's evidence. The present cause is: Historical unrelated alerts are being mistaken for current fault evidence.

C:

This alternative cause would explain a different case: A virtualization host suddenly powers off during peak usage, while PSU telemetry shows overload and a degraded redundant supply. It does not explain the actual incident's evidence. The present cause is: Historical unrelated alerts are being mistaken for current fault evidence.

D:

This alternative cause would explain a different case: A server sounds a fan alarm and CPU temperature rises to its throttling threshold after a replacement fan was connected to the wrong header. It does not explain the actual incident's evidence. The present cause is: Historical unrelated alerts are being mistaken for current fault evidence.

Question 956

A server operations team encounters the following situation: A server's chassis LED flags a failed redundant fan, but engineers replace its disk controller based only on unrelated historical alerts. Which sustained operational control best reduces the likelihood of this same issue recurring?

  1. Inspect fan maps and sensor health after hardware maintenance.
  2. Correlate active hardware indicators with maintenance timestamps.
  3. Check seating and retainer locks on shipped servers.
  4. Check chassis clearances during rack cable and panel maintenance.

Explanation

Correct Answer

B:

This control targets the underlying recurrence risk: Historical unrelated alerts are being mistaken for current fault evidence. It builds validation into the affected workflow and supports the expected recovery result: Replacing the indicated fan clears the active fault and normalizes RPM.

Incorrect Answers

A:

This control addresses a different scenario: A server sounds a fan alarm and CPU temperature rises to its throttling threshold after a replacement fan was connected to the wrong header. That event's root mechanism was improper cooling fan placement reduces effective processor airflow. The described incident instead arises from: Historical unrelated alerts are being mistaken for current fault evidence.

C:

This control addresses a different scenario: An expansion NIC appears intermittently after transport, and chassis logs show PCIe link-training failures in the slot. That event's root mechanism was a marginal PCIe card connection disrupts device enumeration. The described incident instead arises from: Historical unrelated alerts are being mistaken for current fault evidence.

D:

This control addresses a different scenario: A rack has proper ambient temperature but a specific node overheats after someone places a blanking cover across its rear exhaust. That event's root mechanism was local blocked exhaust can overheat a server even with adequate facility cooling. The described incident instead arises from: Historical unrelated alerts are being mistaken for current fault evidence.

Question 957

A server operations team encounters the following situation: A compute node freezes only when a high-speed NIC transfers data; vendor logs show repeated corrected PCIe bus errors. Given the stated symptoms and constraints, which corrective action is the best next step?

  1. Remove the obstruction and validate the chassis's intended airflow direction.
  2. Check shared backplane power and connectors before replacing individual drives.
  3. Use ESD-safe servicing to reseat or replace the supported card and inspect its slot.
  4. Diagnose the affected PCIe path, firmware and supported card compatibility.

Explanation

Correct Answer

D:

The preferred corrective action directly addresses the incident: A compute node freezes only when a high-speed NIC transfers data; vendor logs show repeated corrected PCIe bus errors. The fault mechanism is pCIe signal or firmware instability appears under traffic load. Expected confirmation is: Sustained link testing completes without the relevant corrected-error storm.

Incorrect Answers

A:

This action is better suited to a separate Given a scenario, troubleshoot common hardware failures incident: A rack has proper ambient temperature but a specific node overheats after someone places a blanking cover across its rear exhaust. That case involves: Local blocked exhaust can overheat a server even with adequate facility cooling. Here the observed mechanism is instead: PCIe signal or firmware instability appears under traffic load. Applying the other repair would not directly resolve this fault.

B:

This action is better suited to a separate Given a scenario, troubleshoot common hardware failures incident: A storage chassis reports all eight disks unavailable at once after a backplane power cable was disturbed during maintenance. That case involves: Simultaneous failures across multiple drives point to a shared backplane or power path. Here the observed mechanism is instead: PCIe signal or firmware instability appears under traffic load. Applying the other repair would not directly resolve this fault.

C:

This action is better suited to a separate Given a scenario, troubleshoot common hardware failures incident: An expansion NIC appears intermittently after transport, and chassis logs show PCIe link-training failures in the slot. That case involves: A marginal PCIe card connection disrupts device enumeration. Here the observed mechanism is instead: PCIe signal or firmware instability appears under traffic load. Applying the other repair would not directly resolve this fault.

Question 958

A server operations team encounters the following situation: A compute node freezes only when a high-speed NIC transfers data; vendor logs show repeated corrected PCIe bus errors. After making the corrective change, which result best demonstrates that this particular problem is resolved?

  1. Sustained link testing completes without the relevant corrected-error storm.
  2. The host withstands measured peak load and a controlled single-feed failure.
  3. A CPU stress test shows stable temperatures and no spontaneous shutdown.
  4. POST identifies the processor and passes platform diagnostics.

Explanation

Correct Answer

A:

This is incident-specific acceptance evidence: Sustained link testing completes without the relevant corrected-error storm. It verifies the action diagnose the affected PCIe path, firmware and supported card compatibility. The failure under test was: PCIe signal or firmware instability appears under traffic load.

Incorrect Answers

B:

This observation tests an unrelated Given a scenario, troubleshoot common hardware failures case: A virtualization host suddenly powers off during peak usage, while PSU telemetry shows overload and a degraded redundant supply. It may be true while the current failure persists; the decisive current cause is: PCIe signal or firmware instability appears under traffic load.

C:

This observation tests an unrelated Given a scenario, troubleshoot common hardware failures case: A new CPU cooler has a loose mounting bracket, and server logs show intermittent overheating and unexplained kernel crashes. It may be true while the current failure persists; the decisive current cause is: PCIe signal or firmware instability appears under traffic load.

D:

This observation tests an unrelated Given a scenario, troubleshoot common hardware failures case: A four-CPU node continues displaying hardware faults after a processor replacement because its BIOS version does not recognize the new CPU stepping. It may be true while the current failure persists; the decisive current cause is: PCIe signal or firmware instability appears under traffic load.

Question 959

A server operations team encounters the following situation: A compute node freezes only when a high-speed NIC transfers data; vendor logs show repeated corrected PCIe bus errors. Which underlying cause most specifically explains the observed symptoms?

  1. Processor revision compatibility depends on firmware support.
  2. PCIe signal or firmware instability appears under traffic load.
  3. Platform firmware and controller firmware are incompatible.
  4. Simultaneous failures across multiple drives point to a shared backplane or power path.

Explanation

Correct Answer

B:

This root-cause explanation directly accounts for the reported condition: A compute node freezes only when a high-speed NIC transfers data; vendor logs show repeated corrected PCIe bus errors. The corrective step is: Diagnose the affected PCIe path, firmware and supported card compatibility. The verifying outcome is: Sustained link testing completes without the relevant corrected-error storm.

Incorrect Answers

A:

This alternative cause would explain a different case: A four-CPU node continues displaying hardware faults after a processor replacement because its BIOS version does not recognize the new CPU stepping. It does not explain the actual incident's evidence. The present cause is: PCIe signal or firmware instability appears under traffic load.

C:

This alternative cause would explain a different case: A server stops passing POST after a firmware change, and management logs identify an unsupported revision for its RAID adapter. It does not explain the actual incident's evidence. The present cause is: PCIe signal or firmware instability appears under traffic load.

D:

This alternative cause would explain a different case: A storage chassis reports all eight disks unavailable at once after a backplane power cable was disturbed during maintenance. It does not explain the actual incident's evidence. The present cause is: PCIe signal or firmware instability appears under traffic load.

Question 960

A server operations team encounters the following situation: A compute node freezes only when a high-speed NIC transfers data; vendor logs show repeated corrected PCIe bus errors. Which sustained operational control best reduces the likelihood of this same issue recurring?

  1. Investigate recurring cold-boot setting resets promptly.
  2. Validate populated memory layouts rather than testing only individual sticks.
  3. Monitor correctable bus errors before they become fatal.
  4. Monitor per-supply health and rack electrical headroom.

Explanation

Correct Answer

C:

This control targets the underlying recurrence risk: PCIe signal or firmware instability appears under traffic load. It builds validation into the affected workflow and supports the expected recovery result: Sustained link testing completes without the relevant corrected-error storm.

Incorrect Answers

A:

This control addresses a different scenario: A server loses time and boot order whenever rack power is fully isolated, though it behaves normally across OS-only reboots. That event's root mechanism was a weak battery fails to preserve persistent real-time clock and firmware values. The described incident instead arises from: PCIe signal or firmware instability appears under traffic load.

B:

This control addresses a different scenario: A server reports intermittent DRAM faults only when a new memory channel is populated, though each DIMM passes a standalone test. That event's root mechanism was multi-DIMM electrical loading or a channel fault can appear only in certain populations. The described incident instead arises from: PCIe signal or firmware instability appears under traffic load.

D:

This control addresses a different scenario: A virtualization host suddenly powers off during peak usage, while PSU telemetry shows overload and a degraded redundant supply. That event's root mechanism was insufficient remaining power supply capacity leads to shutdown. The described incident instead arises from: PCIe signal or firmware instability appears under traffic load.