McAfee-Secured Website

Exam Bundle

Exam Code: SK0-005

Exam Name CompTIA Server+ Certification Exam

Certification Provider: CompTIA

Corresponding Certification: CompTIA Server+

CompTIA SK0-005 Bundle $44.99

100% CompTIA SK0-005 Guaranteed Success With Testking Training Materials

Get Real SK0-005 Exam Questions & Expert Verified Answers as Experienced on the Real Exam!

  • Questions & Answers

    SK0-005 Questions & Answers

    617 Questions & Answers

    The ultimate exam preparation tool, Questions & Answers mirrors the actual SK0-005 exam while allowing you to hone and measure every aspect of your test-taking ability.

  • SK0-005 Video Course

    SK0-005 Video Course

    139 Video Lectures

    SK0-005 Video Course is developed by CompTIA Professionals to help you pass the SK0-005 exam.

    Description

    This course will improve your knowledge and skills required to pass CompTIA Server+ Certification Exam exam.
  • Study Guide

    SK0-005 Study Guide

    533 PDF Pages

    Developed by industry experts, this 533-page guide spells out in painstaking detail all of the information you need to ace SK0-005 exam.

CompTIA Server+ Certification Exam (SK0-005) Practice Tests

Satisfaction Guaranteed

Money Back Guarantee

Testking provides hassle-free money back guarantee with our products. That is because we have 100% trust in the abilities of our professional and experience product team, and our record is a proof of that.

99.6% PASS RATE
Total Cost: $194.97
Bundle Price: $149.98

Purchase Individually

  • Questions & Answers

    Questions & Answers

    617 Questions

    $124.99
  • SK0-005 Video Course

    Video Course

    139 Video Lectures

    $39.99
  • Study Guide

    Study Guide

    533 PDF Pages

    $29.99

CompTIA SK0-005 Practice Test 97

Question 960

A server operations team encounters the following situation: A compute node freezes only when a high-speed NIC transfers data; vendor logs show repeated corrected PCIe bus errors. Which sustained operational control best reduces the likelihood of this same issue recurring?

  1. Investigate recurring cold-boot setting resets promptly.
  2. Validate populated memory layouts rather than testing only individual sticks.
  3. Monitor correctable bus errors before they become fatal.
  4. Monitor per-supply health and rack electrical headroom.

Explanation

Correct Answer

C:

This control targets the underlying recurrence risk: PCIe signal or firmware instability appears under traffic load. It builds validation into the affected workflow and supports the expected recovery result: Sustained link testing completes without the relevant corrected-error storm.

Incorrect Answers

A:

This control addresses a different scenario: A server loses time and boot order whenever rack power is fully isolated, though it behaves normally across OS-only reboots. That event's root mechanism was a weak battery fails to preserve persistent real-time clock and firmware values. The described incident instead arises from: PCIe signal or firmware instability appears under traffic load.

B:

This control addresses a different scenario: A server reports intermittent DRAM faults only when a new memory channel is populated, though each DIMM passes a standalone test. That event's root mechanism was multi-DIMM electrical loading or a channel fault can appear only in certain populations. The described incident instead arises from: PCIe signal or firmware instability appears under traffic load.

D:

This control addresses a different scenario: A virtualization host suddenly powers off during peak usage, while PSU telemetry shows overload and a degraded redundant supply. That event's root mechanism was insufficient remaining power supply capacity leads to shutdown. The described incident instead arises from: PCIe signal or firmware instability appears under traffic load.

Question 961

A server operations team encounters the following situation: A maintenance technician blows dust deeper into server fan bearings with uncontrolled shop compressed air, after which fans vibrate and overheat. Given the stated symptoms and constraints, which corrective action is the best next step?

  1. Use vendor-approved ESD-safe cleaning and replace damaged cooling components.
  2. Reseat the compatible heat sink using manufacturer mounting procedure and thermal material.
  3. Use vendor-supported firmware recovery to restore compatible component versions.
  4. Remove the obstruction and validate the chassis's intended airflow direction.

Explanation

Correct Answer

A:

The preferred corrective action directly addresses the incident: A maintenance technician blows dust deeper into server fan bearings with uncontrolled shop compressed air, after which fans vibrate and overheat. The fault mechanism is improper cleaning can damage fans instead of restoring airflow. Expected confirmation is: Fans run within vibration and temperature tolerances after service.

Incorrect Answers

B:

This action is better suited to a separate Given a scenario, troubleshoot common hardware failures incident: A new CPU cooler has a loose mounting bracket, and server logs show intermittent overheating and unexplained kernel crashes. That case involves: Poor heat transfer from the CPU to its cooling assembly causes instability. Here the observed mechanism is instead: Improper cleaning can damage fans instead of restoring airflow. Applying the other repair would not directly resolve this fault.

C:

This action is better suited to a separate Given a scenario, troubleshoot common hardware failures incident: A server stops passing POST after a firmware change, and management logs identify an unsupported revision for its RAID adapter. That case involves: Platform firmware and controller firmware are incompatible. Here the observed mechanism is instead: Improper cleaning can damage fans instead of restoring airflow. Applying the other repair would not directly resolve this fault.

D:

This action is better suited to a separate Given a scenario, troubleshoot common hardware failures incident: A rack has proper ambient temperature but a specific node overheats after someone places a blanking cover across its rear exhaust. That case involves: Local blocked exhaust can overheat a server even with adequate facility cooling. Here the observed mechanism is instead: Improper cleaning can damage fans instead of restoring airflow. Applying the other repair would not directly resolve this fault.

Question 962

A server operations team encounters the following situation: A maintenance technician blows dust deeper into server fan bearings with uncontrolled shop compressed air, after which fans vibrate and overheat. After making the corrective change, which result best demonstrates that this particular problem is resolved?

  1. Firmware clock and boot priority persist after a full power removal.
  2. Fans run within vibration and temperature tolerances after service.
  3. A tested supported DIMM configuration runs without memory controller errors.
  4. Sustained link testing completes without the relevant corrected-error storm.

Explanation

Correct Answer

B:

This is incident-specific acceptance evidence: Fans run within vibration and temperature tolerances after service. It verifies the action use vendor-approved ESD-safe cleaning and replace damaged cooling components. The failure under test was: Improper cleaning can damage fans instead of restoring airflow.

Incorrect Answers

A:

This observation tests an unrelated Given a scenario, troubleshoot common hardware failures case: A server loses time and boot order whenever rack power is fully isolated, though it behaves normally across OS-only reboots. It may be true while the current failure persists; the decisive current cause is: Improper cleaning can damage fans instead of restoring airflow.

C:

This observation tests an unrelated Given a scenario, troubleshoot common hardware failures case: A server reports intermittent DRAM faults only when a new memory channel is populated, though each DIMM passes a standalone test. It may be true while the current failure persists; the decisive current cause is: Improper cleaning can damage fans instead of restoring airflow.

D:

This observation tests an unrelated Given a scenario, troubleshoot common hardware failures case: A compute node freezes only when a high-speed NIC transfers data; vendor logs show repeated corrected PCIe bus errors. It may be true while the current failure persists; the decisive current cause is: Improper cleaning can damage fans instead of restoring airflow.

Question 963

A server operations team encounters the following situation: A maintenance technician blows dust deeper into server fan bearings with uncontrolled shop compressed air, after which fans vibrate and overheat. Which underlying cause most specifically explains the observed symptoms?

  1. Improper cooling fan placement reduces effective processor airflow.
  2. PCIe signal or firmware instability appears under traffic load.
  3. Improper cleaning can damage fans instead of restoring airflow.
  4. Simultaneous failures across multiple drives point to a shared backplane or power path.

Explanation

Correct Answer

C:

This root-cause explanation directly accounts for the reported condition: A maintenance technician blows dust deeper into server fan bearings with uncontrolled shop compressed air, after which fans vibrate and overheat. The corrective step is: Use vendor-approved ESD-safe cleaning and replace damaged cooling components. The verifying outcome is: Fans run within vibration and temperature tolerances after service.

Incorrect Answers

A:

This alternative cause would explain a different case: A server sounds a fan alarm and CPU temperature rises to its throttling threshold after a replacement fan was connected to the wrong header. It does not explain the actual incident's evidence. The present cause is: Improper cleaning can damage fans instead of restoring airflow.

B:

This alternative cause would explain a different case: A compute node freezes only when a high-speed NIC transfers data; vendor logs show repeated corrected PCIe bus errors. It does not explain the actual incident's evidence. The present cause is: Improper cleaning can damage fans instead of restoring airflow.

D:

This alternative cause would explain a different case: A storage chassis reports all eight disks unavailable at once after a backplane power cable was disturbed during maintenance. It does not explain the actual incident's evidence. The present cause is: Improper cleaning can damage fans instead of restoring airflow.

Question 964

A server operations team encounters the following situation: A maintenance technician blows dust deeper into server fan bearings with uncontrolled shop compressed air, after which fans vibrate and overheat. Which sustained operational control best reduces the likelihood of this same issue recurring?

  1. Monitor per-supply health and rack electrical headroom.
  2. Test firmware dependency matrices before updates.
  3. Trend ECC events and retire failing modules before service loss.
  4. Follow approved compressed-air and rotor-control instructions.

Explanation

Correct Answer

D:

This control targets the underlying recurrence risk: Improper cleaning can damage fans instead of restoring airflow. It builds validation into the affected workflow and supports the expected recovery result: Fans run within vibration and temperature tolerances after service.

Incorrect Answers

A:

This control addresses a different scenario: A virtualization host suddenly powers off during peak usage, while PSU telemetry shows overload and a degraded redundant supply. That event's root mechanism was insufficient remaining power supply capacity leads to shutdown. The described incident instead arises from: Improper cleaning can damage fans instead of restoring airflow.

B:

This control addresses a different scenario: A server stops passing POST after a firmware change, and management logs identify an unsupported revision for its RAID adapter. That event's root mechanism was platform firmware and controller firmware are incompatible. The described incident instead arises from: Improper cleaning can damage fans instead of restoring airflow.

C:

This control addresses a different scenario: A compute server produces repeated uncorrectable ECC memory errors followed by kernel panics, while its processor temperatures remain normal. That event's root mechanism was uncorrectable RAM faults can cause host crashes independently of thermal conditions. The described incident instead arises from: Improper cleaning can damage fans instead of restoring airflow.

Question 965

A server operations team encounters the following situation: A rack has proper ambient temperature but a specific node overheats after someone places a blanking cover across its rear exhaust. Given the stated symptoms and constraints, which corrective action is the best next step?

  1. Consult model POST diagnostics and replace DIMMs with supported parts.
  2. Remove the obstruction and validate the chassis's intended airflow direction.
  3. Restore the approved airflow path and retest the GPU cooling system.
  4. Check shared backplane power and connectors before replacing individual drives.

Explanation

Correct Answer

B:

The preferred corrective action directly addresses the incident: A rack has proper ambient temperature but a specific node overheats after someone places a blanking cover across its rear exhaust. The fault mechanism is local blocked exhaust can overheat a server even with adequate facility cooling. Expected confirmation is: The node temperature normalizes under the same room conditions.

Incorrect Answers

A:

This action is better suited to a separate Given a scenario, troubleshoot common hardware failures incident: A rack server emits repeated POST beep codes and never initializes video after a technician installs unsupported memory DIMMs. That case involves: Unsupported or misconfigured memory prevents hardware initialization. Here the observed mechanism is instead: Local blocked exhaust can overheat a server even with adequate facility cooling. Applying the other repair would not directly resolve this fault.

C:

This action is better suited to a separate Given a scenario, troubleshoot common hardware failures incident: A blade's host crashes when its GPU workload starts, but temperature logs reveal rapid GPU overheating and an obstructed air duct. That case involves: The workload exposes insufficient GPU cooling rather than an application-only defect. Here the observed mechanism is instead: Local blocked exhaust can overheat a server even with adequate facility cooling. Applying the other repair would not directly resolve this fault.

D:

This action is better suited to a separate Given a scenario, troubleshoot common hardware failures incident: A storage chassis reports all eight disks unavailable at once after a backplane power cable was disturbed during maintenance. That case involves: Simultaneous failures across multiple drives point to a shared backplane or power path. Here the observed mechanism is instead: Local blocked exhaust can overheat a server even with adequate facility cooling. Applying the other repair would not directly resolve this fault.

Question 966

A server operations team encounters the following situation: A rack has proper ambient temperature but a specific node overheats after someone places a blanking cover across its rear exhaust. After making the corrective change, which result best demonstrates that this particular problem is resolved?

  1. Replacing the indicated fan clears the active fault and normalizes RPM.
  2. All eight expected physical disks reappear without unnecessary replacements.
  3. The node temperature normalizes under the same room conditions.
  4. A CPU stress test shows stable temperatures and no spontaneous shutdown.

Explanation

Correct Answer

C:

This is incident-specific acceptance evidence: The node temperature normalizes under the same room conditions. It verifies the action remove the obstruction and validate the chassis's intended airflow direction. The failure under test was: Local blocked exhaust can overheat a server even with adequate facility cooling.

Incorrect Answers

A:

This observation tests an unrelated Given a scenario, troubleshoot common hardware failures case: A server's chassis LED flags a failed redundant fan, but engineers replace its disk controller based only on unrelated historical alerts. It may be true while the current failure persists; the decisive current cause is: Local blocked exhaust can overheat a server even with adequate facility cooling.

B:

This observation tests an unrelated Given a scenario, troubleshoot common hardware failures case: A storage chassis reports all eight disks unavailable at once after a backplane power cable was disturbed during maintenance. It may be true while the current failure persists; the decisive current cause is: Local blocked exhaust can overheat a server even with adequate facility cooling.

D:

This observation tests an unrelated Given a scenario, troubleshoot common hardware failures case: A new CPU cooler has a loose mounting bracket, and server logs show intermittent overheating and unexplained kernel crashes. It may be true while the current failure persists; the decisive current cause is: Local blocked exhaust can overheat a server even with adequate facility cooling.

Question 967

A server operations team encounters the following situation: A rack has proper ambient temperature but a specific node overheats after someone places a blanking cover across its rear exhaust. Which underlying cause most specifically explains the observed symptoms?

  1. Poor heat transfer from the CPU to its cooling assembly causes instability.
  2. Simultaneous failures across multiple drives point to a shared backplane or power path.
  3. Improper cooling fan placement reduces effective processor airflow.
  4. Local blocked exhaust can overheat a server even with adequate facility cooling.

Explanation

Correct Answer

D:

This root-cause explanation directly accounts for the reported condition: A rack has proper ambient temperature but a specific node overheats after someone places a blanking cover across its rear exhaust. The corrective step is: Remove the obstruction and validate the chassis's intended airflow direction. The verifying outcome is: The node temperature normalizes under the same room conditions.

Incorrect Answers

A:

This alternative cause would explain a different case: A new CPU cooler has a loose mounting bracket, and server logs show intermittent overheating and unexplained kernel crashes. It does not explain the actual incident's evidence. The present cause is: Local blocked exhaust can overheat a server even with adequate facility cooling.

B:

This alternative cause would explain a different case: A storage chassis reports all eight disks unavailable at once after a backplane power cable was disturbed during maintenance. It does not explain the actual incident's evidence. The present cause is: Local blocked exhaust can overheat a server even with adequate facility cooling.

C:

This alternative cause would explain a different case: A server sounds a fan alarm and CPU temperature rises to its throttling threshold after a replacement fan was connected to the wrong header. It does not explain the actual incident's evidence. The present cause is: Local blocked exhaust can overheat a server even with adequate facility cooling.

Question 968

A server operations team encounters the following situation: A rack has proper ambient temperature but a specific node overheats after someone places a blanking cover across its rear exhaust. Which sustained operational control best reduces the likelihood of this same issue recurring?

  1. Check chassis clearances during rack cable and panel maintenance.
  2. Monitor per-supply health and rack electrical headroom.
  3. Check CPU stepping and firmware prerequisites during parts swaps.
  4. Inspect fan maps and sensor health after hardware maintenance.

Explanation

Correct Answer

A:

This control targets the underlying recurrence risk: Local blocked exhaust can overheat a server even with adequate facility cooling. It builds validation into the affected workflow and supports the expected recovery result: The node temperature normalizes under the same room conditions.

Incorrect Answers

B:

This control addresses a different scenario: A virtualization host suddenly powers off during peak usage, while PSU telemetry shows overload and a degraded redundant supply. That event's root mechanism was insufficient remaining power supply capacity leads to shutdown. The described incident instead arises from: Local blocked exhaust can overheat a server even with adequate facility cooling.

C:

This control addresses a different scenario: A four-CPU node continues displaying hardware faults after a processor replacement because its BIOS version does not recognize the new CPU stepping. That event's root mechanism was processor revision compatibility depends on firmware support. The described incident instead arises from: Local blocked exhaust can overheat a server even with adequate facility cooling.

D:

This control addresses a different scenario: A server sounds a fan alarm and CPU temperature rises to its throttling threshold after a replacement fan was connected to the wrong header. That event's root mechanism was improper cooling fan placement reduces effective processor airflow. The described incident instead arises from: Local blocked exhaust can overheat a server even with adequate facility cooling.

Question 969

A server operations team encounters the following situation: A server reports intermittent DRAM faults only when a new memory channel is populated, though each DIMM passes a standalone test. Given the stated symptoms and constraints, which corrective action is the best next step?

  1. Diagnose the affected PCIe path, firmware and supported card compatibility.
  2. Correct fan installation and verify thermal control with hardware diagnostics.
  3. Check memory channel layout and CPU/motherboard compatibility, then isolate the failing slot or controller.
  4. Use vendor diagnostics to isolate and replace the failed memory module or channel.

Explanation

Correct Answer

C:

The preferred corrective action directly addresses the incident: A server reports intermittent DRAM faults only when a new memory channel is populated, though each DIMM passes a standalone test. The fault mechanism is multi-DIMM electrical loading or a channel fault can appear only in certain populations. Expected confirmation is: A tested supported DIMM configuration runs without memory controller errors.

Incorrect Answers

A:

This action is better suited to a separate Given a scenario, troubleshoot common hardware failures incident: A compute node freezes only when a high-speed NIC transfers data; vendor logs show repeated corrected PCIe bus errors. That case involves: PCIe signal or firmware instability appears under traffic load. Here the observed mechanism is instead: Multi-DIMM electrical loading or a channel fault can appear only in certain populations. Applying the other repair would not directly resolve this fault.

B:

This action is better suited to a separate Given a scenario, troubleshoot common hardware failures incident: A server sounds a fan alarm and CPU temperature rises to its throttling threshold after a replacement fan was connected to the wrong header. That case involves: Improper cooling fan placement reduces effective processor airflow. Here the observed mechanism is instead: Multi-DIMM electrical loading or a channel fault can appear only in certain populations. Applying the other repair would not directly resolve this fault.

D:

This action is better suited to a separate Given a scenario, troubleshoot common hardware failures incident: A compute server produces repeated uncorrectable ECC memory errors followed by kernel panics, while its processor temperatures remain normal. That case involves: Uncorrectable RAM faults can cause host crashes independently of thermal conditions. Here the observed mechanism is instead: Multi-DIMM electrical loading or a channel fault can appear only in certain populations. Applying the other repair would not directly resolve this fault.

Question 970

A server operations team encounters the following situation: A server reports intermittent DRAM faults only when a new memory channel is populated, though each DIMM passes a standalone test. After making the corrective change, which result best demonstrates that this particular problem is resolved?

  1. NIC inventory and link status remain stable across cold starts.
  2. All eight expected physical disks reappear without unnecessary replacements.
  3. Sustained link testing completes without the relevant corrected-error storm.
  4. A tested supported DIMM configuration runs without memory controller errors.

Explanation

Correct Answer

D:

This is incident-specific acceptance evidence: A tested supported DIMM configuration runs without memory controller errors. It verifies the action check memory channel layout and CPU/motherboard compatibility, then isolate the failing slot or controller. The failure under test was: Multi-DIMM electrical loading or a channel fault can appear only in certain populations.

Incorrect Answers

A:

This observation tests an unrelated Given a scenario, troubleshoot common hardware failures case: An expansion NIC appears intermittently after transport, and chassis logs show PCIe link-training failures in the slot. It may be true while the current failure persists; the decisive current cause is: Multi-DIMM electrical loading or a channel fault can appear only in certain populations.

B:

This observation tests an unrelated Given a scenario, troubleshoot common hardware failures case: A storage chassis reports all eight disks unavailable at once after a backplane power cable was disturbed during maintenance. It may be true while the current failure persists; the decisive current cause is: Multi-DIMM electrical loading or a channel fault can appear only in certain populations.

C:

This observation tests an unrelated Given a scenario, troubleshoot common hardware failures case: A compute node freezes only when a high-speed NIC transfers data; vendor logs show repeated corrected PCIe bus errors. It may be true while the current failure persists; the decisive current cause is: Multi-DIMM electrical loading or a channel fault can appear only in certain populations.