McAfee-Secured Website

Exam Bundle

Exam Code: SK0-005

Exam Name CompTIA Server+ Certification Exam

Certification Provider: CompTIA

Corresponding Certification: CompTIA Server+

CompTIA SK0-005 Bundle $44.99

100% CompTIA SK0-005 Guaranteed Success With Testking Training Materials

Get Real SK0-005 Exam Questions & Expert Verified Answers as Experienced on the Real Exam!

  • Questions & Answers

    SK0-005 Questions & Answers

    617 Questions & Answers

    The ultimate exam preparation tool, Questions & Answers mirrors the actual SK0-005 exam while allowing you to hone and measure every aspect of your test-taking ability.

  • SK0-005 Video Course

    SK0-005 Video Course

    139 Video Lectures

    SK0-005 Video Course is developed by CompTIA Professionals to help you pass the SK0-005 exam.

    Description

    This course will improve your knowledge and skills required to pass CompTIA Server+ Certification Exam exam.
  • Study Guide

    SK0-005 Study Guide

    533 PDF Pages

    Developed by industry experts, this 533-page guide spells out in painstaking detail all of the information you need to ace SK0-005 exam.

CompTIA Server+ Certification Exam (SK0-005) Practice Tests

Satisfaction Guaranteed

Money Back Guarantee

Testking provides hassle-free money back guarantee with our products. That is because we have 100% trust in the abilities of our professional and experience product team, and our record is a proof of that.

99.6% PASS RATE
Total Cost: $194.97
Bundle Price: $149.98

Purchase Individually

  • Questions & Answers

    Questions & Answers

    617 Questions

    $124.99
  • SK0-005 Video Course

    Video Course

    139 Video Lectures

    $39.99
  • Study Guide

    Study Guide

    533 PDF Pages

    $29.99

CompTIA SK0-005 Practice Test 98

Question 970

A server operations team encounters the following situation: A server reports intermittent DRAM faults only when a new memory channel is populated, though each DIMM passes a standalone test. After making the corrective change, which result best demonstrates that this particular problem is resolved?

  1. NIC inventory and link status remain stable across cold starts.
  2. All eight expected physical disks reappear without unnecessary replacements.
  3. Sustained link testing completes without the relevant corrected-error storm.
  4. A tested supported DIMM configuration runs without memory controller errors.

Explanation

Correct Answer

D:

This is incident-specific acceptance evidence: A tested supported DIMM configuration runs without memory controller errors. It verifies the action check memory channel layout and CPU/motherboard compatibility, then isolate the failing slot or controller. The failure under test was: Multi-DIMM electrical loading or a channel fault can appear only in certain populations.

Incorrect Answers

A:

This observation tests an unrelated Given a scenario, troubleshoot common hardware failures case: An expansion NIC appears intermittently after transport, and chassis logs show PCIe link-training failures in the slot. It may be true while the current failure persists; the decisive current cause is: Multi-DIMM electrical loading or a channel fault can appear only in certain populations.

B:

This observation tests an unrelated Given a scenario, troubleshoot common hardware failures case: A storage chassis reports all eight disks unavailable at once after a backplane power cable was disturbed during maintenance. It may be true while the current failure persists; the decisive current cause is: Multi-DIMM electrical loading or a channel fault can appear only in certain populations.

C:

This observation tests an unrelated Given a scenario, troubleshoot common hardware failures case: A compute node freezes only when a high-speed NIC transfers data; vendor logs show repeated corrected PCIe bus errors. It may be true while the current failure persists; the decisive current cause is: Multi-DIMM electrical loading or a channel fault can appear only in certain populations.

Question 971

A server operations team encounters the following situation: A server reports intermittent DRAM faults only when a new memory channel is populated, though each DIMM passes a standalone test. Which underlying cause most specifically explains the observed symptoms?

  1. Multi-DIMM electrical loading or a channel fault can appear only in certain populations.
  2. Insufficient remaining power supply capacity leads to shutdown.
  3. Unsupported or misconfigured memory prevents hardware initialization.
  4. Poor heat transfer from the CPU to its cooling assembly causes instability.

Explanation

Correct Answer

A:

This root-cause explanation directly accounts for the reported condition: A server reports intermittent DRAM faults only when a new memory channel is populated, though each DIMM passes a standalone test. The corrective step is: Check memory channel layout and CPU/motherboard compatibility, then isolate the failing slot or controller. The verifying outcome is: A tested supported DIMM configuration runs without memory controller errors.

Incorrect Answers

B:

This alternative cause would explain a different case: A virtualization host suddenly powers off during peak usage, while PSU telemetry shows overload and a degraded redundant supply. It does not explain the actual incident's evidence. The present cause is: Multi-DIMM electrical loading or a channel fault can appear only in certain populations.

C:

This alternative cause would explain a different case: A rack server emits repeated POST beep codes and never initializes video after a technician installs unsupported memory DIMMs. It does not explain the actual incident's evidence. The present cause is: Multi-DIMM electrical loading or a channel fault can appear only in certain populations.

D:

This alternative cause would explain a different case: A new CPU cooler has a loose mounting bracket, and server logs show intermittent overheating and unexplained kernel crashes. It does not explain the actual incident's evidence. The present cause is: Multi-DIMM electrical loading or a channel fault can appear only in certain populations.

Question 972

A server operations team encounters the following situation: A server reports intermittent DRAM faults only when a new memory channel is populated, though each DIMM passes a standalone test. Which sustained operational control best reduces the likelihood of this same issue recurring?

  1. Monitor per-supply health and rack electrical headroom.
  2. Validate populated memory layouts rather than testing only individual sticks.
  3. Inspect fan maps and sensor health after hardware maintenance.
  4. Inspect shared connectors after internal chassis service.

Explanation

Correct Answer

B:

This control targets the underlying recurrence risk: Multi-DIMM electrical loading or a channel fault can appear only in certain populations. It builds validation into the affected workflow and supports the expected recovery result: A tested supported DIMM configuration runs without memory controller errors.

Incorrect Answers

A:

This control addresses a different scenario: A virtualization host suddenly powers off during peak usage, while PSU telemetry shows overload and a degraded redundant supply. That event's root mechanism was insufficient remaining power supply capacity leads to shutdown. The described incident instead arises from: Multi-DIMM electrical loading or a channel fault can appear only in certain populations.

C:

This control addresses a different scenario: A server sounds a fan alarm and CPU temperature rises to its throttling threshold after a replacement fan was connected to the wrong header. That event's root mechanism was improper cooling fan placement reduces effective processor airflow. The described incident instead arises from: Multi-DIMM electrical loading or a channel fault can appear only in certain populations.

D:

This control addresses a different scenario: A storage chassis reports all eight disks unavailable at once after a backplane power cable was disturbed during maintenance. That event's root mechanism was simultaneous failures across multiple drives point to a shared backplane or power path. The described incident instead arises from: Multi-DIMM electrical loading or a channel fault can appear only in certain populations.

Question 973

A server operations team encounters the following situation: A four-CPU node continues displaying hardware faults after a processor replacement because its BIOS version does not recognize the new CPU stepping. Given the stated symptoms and constraints, which corrective action is the best next step?

  1. Reseat the compatible heat sink using manufacturer mounting procedure and thermal material.
  2. Restore the approved airflow path and retest the GPU cooling system.
  3. Use ESD-safe servicing to reseat or replace the supported card and inspect its slot.
  4. Apply the minimum vendor-supported firmware for that processor before enabling production use.

Explanation

Correct Answer

D:

The preferred corrective action directly addresses the incident: A four-CPU node continues displaying hardware faults after a processor replacement because its BIOS version does not recognize the new CPU stepping. The fault mechanism is processor revision compatibility depends on firmware support. Expected confirmation is: POST identifies the processor and passes platform diagnostics.

Incorrect Answers

A:

This action is better suited to a separate Given a scenario, troubleshoot common hardware failures incident: A new CPU cooler has a loose mounting bracket, and server logs show intermittent overheating and unexplained kernel crashes. That case involves: Poor heat transfer from the CPU to its cooling assembly causes instability. Here the observed mechanism is instead: Processor revision compatibility depends on firmware support. Applying the other repair would not directly resolve this fault.

B:

This action is better suited to a separate Given a scenario, troubleshoot common hardware failures incident: A blade's host crashes when its GPU workload starts, but temperature logs reveal rapid GPU overheating and an obstructed air duct. That case involves: The workload exposes insufficient GPU cooling rather than an application-only defect. Here the observed mechanism is instead: Processor revision compatibility depends on firmware support. Applying the other repair would not directly resolve this fault.

C:

This action is better suited to a separate Given a scenario, troubleshoot common hardware failures incident: An expansion NIC appears intermittently after transport, and chassis logs show PCIe link-training failures in the slot. That case involves: A marginal PCIe card connection disrupts device enumeration. Here the observed mechanism is instead: Processor revision compatibility depends on firmware support. Applying the other repair would not directly resolve this fault.

Question 974

A server operations team encounters the following situation: A four-CPU node continues displaying hardware faults after a processor replacement because its BIOS version does not recognize the new CPU stepping. After making the corrective change, which result best demonstrates that this particular problem is resolved?

  1. POST identifies the processor and passes platform diagnostics.
  2. Sustained link testing completes without the relevant corrected-error storm.
  3. The host withstands measured peak load and a controlled single-feed failure.
  4. All eight expected physical disks reappear without unnecessary replacements.

Explanation

Correct Answer

A:

This is incident-specific acceptance evidence: POST identifies the processor and passes platform diagnostics. It verifies the action apply the minimum vendor-supported firmware for that processor before enabling production use. The failure under test was: Processor revision compatibility depends on firmware support.

Incorrect Answers

B:

This observation tests an unrelated Given a scenario, troubleshoot common hardware failures case: A compute node freezes only when a high-speed NIC transfers data; vendor logs show repeated corrected PCIe bus errors. It may be true while the current failure persists; the decisive current cause is: Processor revision compatibility depends on firmware support.

C:

This observation tests an unrelated Given a scenario, troubleshoot common hardware failures case: A virtualization host suddenly powers off during peak usage, while PSU telemetry shows overload and a degraded redundant supply. It may be true while the current failure persists; the decisive current cause is: Processor revision compatibility depends on firmware support.

D:

This observation tests an unrelated Given a scenario, troubleshoot common hardware failures case: A storage chassis reports all eight disks unavailable at once after a backplane power cable was disturbed during maintenance. It may be true while the current failure persists; the decisive current cause is: Processor revision compatibility depends on firmware support.

Question 975

A server operations team encounters the following situation: A four-CPU node continues displaying hardware faults after a processor replacement because its BIOS version does not recognize the new CPU stepping. Which underlying cause most specifically explains the observed symptoms?

  1. Local blocked exhaust can overheat a server even with adequate facility cooling.
  2. Processor revision compatibility depends on firmware support.
  3. A weak battery fails to preserve persistent real-time clock and firmware values.
  4. A marginal PCIe card connection disrupts device enumeration.

Explanation

Correct Answer

B:

This root-cause explanation directly accounts for the reported condition: A four-CPU node continues displaying hardware faults after a processor replacement because its BIOS version does not recognize the new CPU stepping. The corrective step is: Apply the minimum vendor-supported firmware for that processor before enabling production use. The verifying outcome is: POST identifies the processor and passes platform diagnostics.

Incorrect Answers

A:

This alternative cause would explain a different case: A rack has proper ambient temperature but a specific node overheats after someone places a blanking cover across its rear exhaust. It does not explain the actual incident's evidence. The present cause is: Processor revision compatibility depends on firmware support.

C:

This alternative cause would explain a different case: A server loses time and boot order whenever rack power is fully isolated, though it behaves normally across OS-only reboots. It does not explain the actual incident's evidence. The present cause is: Processor revision compatibility depends on firmware support.

D:

This alternative cause would explain a different case: An expansion NIC appears intermittently after transport, and chassis logs show PCIe link-training failures in the slot. It does not explain the actual incident's evidence. The present cause is: Processor revision compatibility depends on firmware support.

Question 976

A server operations team encounters the following situation: A four-CPU node continues displaying hardware faults after a processor replacement because its BIOS version does not recognize the new CPU stepping. Which sustained operational control best reduces the likelihood of this same issue recurring?

  1. Inspect shared connectors after internal chassis service.
  2. Monitor correctable bus errors before they become fatal.
  3. Check CPU stepping and firmware prerequisites during parts swaps.
  4. Cross-check DIMM speed, rank and placement against vendor HCLs.

Explanation

Correct Answer

C:

This control targets the underlying recurrence risk: Processor revision compatibility depends on firmware support. It builds validation into the affected workflow and supports the expected recovery result: POST identifies the processor and passes platform diagnostics.

Incorrect Answers

A:

This control addresses a different scenario: A storage chassis reports all eight disks unavailable at once after a backplane power cable was disturbed during maintenance. That event's root mechanism was simultaneous failures across multiple drives point to a shared backplane or power path. The described incident instead arises from: Processor revision compatibility depends on firmware support.

B:

This control addresses a different scenario: A compute node freezes only when a high-speed NIC transfers data; vendor logs show repeated corrected PCIe bus errors. That event's root mechanism was pCIe signal or firmware instability appears under traffic load. The described incident instead arises from: Processor revision compatibility depends on firmware support.

D:

This control addresses a different scenario: A rack server emits repeated POST beep codes and never initializes video after a technician installs unsupported memory DIMMs. That event's root mechanism was unsupported or misconfigured memory prevents hardware initialization. The described incident instead arises from: Processor revision compatibility depends on firmware support.

Question 977

A server operations team encounters the following situation: A RAID 5 volume runs degraded for days, then a second disk fails during a rebuild and the filesystem becomes unavailable. Given the stated symptoms and constraints, which corrective action is the best next step?

  1. Stop unsafe rebuild attempts and recover using a verified backup or specialist process.
  2. Tune supported rebuild priority and capacity plan without compromising array protection.
  3. Identify inode exhaustion and safely remove or archive unnecessary small files.
  4. Configure supported multipathing and verify both independent storage paths.

Explanation

Correct Answer

A:

The preferred corrective action directly addresses the incident: A RAID 5 volume runs degraded for days, then a second disk fails during a rebuild and the filesystem becomes unavailable. The fault mechanism is rAID 5 cannot tolerate two simultaneous drive failures. Expected confirmation is: Validated recovery restores required data without writing to compromised members.

Incorrect Answers

B:

This action is better suited to a separate Given a scenario, troubleshoot storage problems incident: A storage pool's rebuild takes days on large slow HDDs, during which application latency spikes and background verification collides with production demand. That case involves: Rebuild I/O competes with application I/O on constrained drives. Here the observed mechanism is instead: RAID 5 cannot tolerate two simultaneous drive failures. Applying the other repair would not directly resolve this fault.

C:

This action is better suited to a separate Given a scenario, troubleshoot storage problems incident: A storage host has 50 GB free but a Linux application cannot create new small files; filesystem inode availability is zero. That case involves: Free data blocks do not guarantee free filesystem metadata inodes. Here the observed mechanism is instead: RAID 5 cannot tolerate two simultaneous drive failures. Applying the other repair would not directly resolve this fault.

D:

This action is better suited to a separate Given a scenario, troubleshoot storage problems incident: A storage system with dual paths uses only one multipath route, and a planned HBA shutdown causes a total I/O outage. That case involves: Redundant physical ports provide no resilience without usable alternate paths. Here the observed mechanism is instead: RAID 5 cannot tolerate two simultaneous drive failures. Applying the other repair would not directly resolve this fault.

Question 978

A server operations team encounters the following situation: A RAID 5 volume runs degraded for days, then a second disk fails during a rebuild and the filesystem becomes unavailable. After making the corrective change, which result best demonstrates that this particular problem is resolved?

  1. The HBA path stays stable and optical error counters stop increasing.
  2. Validated recovery restores required data without writing to compromised members.
  3. A full scheduled backup completes with measured headroom.
  4. The selected backup restores and its checksum matches recorded expected values.

Explanation

Correct Answer

B:

This is incident-specific acceptance evidence: Validated recovery restores required data without writing to compromised members. It verifies the action stop unsafe rebuild attempts and recover using a verified backup or specialist process. The failure under test was: RAID 5 cannot tolerate two simultaneous drive failures.

Incorrect Answers

A:

This observation tests an unrelated Given a scenario, troubleshoot storage problems case: A SAN volume disappears intermittently after a fiber patch replacement and port counters show increasing optical receive errors. It may be true while the current failure persists; the decisive current cause is: RAID 5 cannot tolerate two simultaneous drive failures.

C:

This observation tests an unrelated Given a scenario, troubleshoot storage problems case: A backup job fails at 70% every night because its target volume runs out of available capacity during the incremental chain. It may be true while the current failure persists; the decisive current cause is: RAID 5 cannot tolerate two simultaneous drive failures.

D:

This observation tests an unrelated Given a scenario, troubleshoot storage problems case: A backup restore complains about a corrupt archive despite correct target capacity; a checksum differs between the repository and source media. It may be true while the current failure persists; the decisive current cause is: RAID 5 cannot tolerate two simultaneous drive failures.

Question 979

A server operations team encounters the following situation: A RAID 5 volume runs degraded for days, then a second disk fails during a rebuild and the filesystem becomes unavailable. Which underlying cause most specifically explains the observed symptoms?

  1. Rebuild I/O competes with application I/O on constrained drives.
  2. Block detection is independent from filesystem format compatibility.
  3. RAID 5 cannot tolerate two simultaneous drive failures.
  4. Increasing virtual block capacity does not automatically resize in-guest structures.

Explanation

Correct Answer

C:

This root-cause explanation directly accounts for the reported condition: A RAID 5 volume runs degraded for days, then a second disk fails during a rebuild and the filesystem becomes unavailable. The corrective step is: Stop unsafe rebuild attempts and recover using a verified backup or specialist process. The verifying outcome is: Validated recovery restores required data without writing to compromised members.

Incorrect Answers

A:

This alternative cause would explain a different case: A storage pool's rebuild takes days on large slow HDDs, during which application latency spikes and background verification collides with production demand. It does not explain the actual incident's evidence. The present cause is: RAID 5 cannot tolerate two simultaneous drive failures.

B:

This alternative cause would explain a different case: A Linux SAN volume is visible as a block device but fails to mount after migration because the new host lacks the filesystem driver. It does not explain the actual incident's evidence. The present cause is: RAID 5 cannot tolerate two simultaneous drive failures.

D:

This alternative cause would explain a different case: An administrator expands a virtual disk but the guest still sees the old filesystem capacity, causing an application out-of-space error. It does not explain the actual incident's evidence. The present cause is: RAID 5 cannot tolerate two simultaneous drive failures.

Question 980

A server operations team encounters the following situation: A RAID 5 volume runs degraded for days, then a second disk fails during a rebuild and the filesystem becomes unavailable. Which sustained operational control best reduces the likelihood of this same issue recurring?

  1. Trend SMART health and replace predictive failures before outage.
  2. Use a verified end-to-end storage expansion runbook.
  3. Factor rebuild windows into drive and RAID sizing.
  4. Alert and act promptly on degraded arrays with recovery readiness.

Explanation

Correct Answer

D:

This control targets the underlying recurrence risk: RAID 5 cannot tolerate two simultaneous drive failures. It builds validation into the affected workflow and supports the expected recovery result: Validated recovery restores required data without writing to compromised members.

Incorrect Answers

A:

This control addresses a different scenario: A database becomes read-only after storage logs report repeated bad blocks and SMART attributes degrade on one HDD. That event's root mechanism was the physical disk has developing media errors. The described incident instead arises from: RAID 5 cannot tolerate two simultaneous drive failures.

B:

This control addresses a different scenario: An administrator expands a virtual disk but the guest still sees the old filesystem capacity, causing an application out-of-space error. That event's root mechanism was increasing virtual block capacity does not automatically resize in-guest structures. The described incident instead arises from: RAID 5 cannot tolerate two simultaneous drive failures.

C:

This control addresses a different scenario: A storage pool's rebuild takes days on large slow HDDs, during which application latency spikes and background verification collides with production demand. That event's root mechanism was rebuild I/O competes with application I/O on constrained drives. The described incident instead arises from: RAID 5 cannot tolerate two simultaneous drive failures.