McAfee-Secured Website

Exam Bundle

Exam Code: SK0-005

Exam Name CompTIA Server+ Certification Exam

Certification Provider: CompTIA

Corresponding Certification: CompTIA Server+

CompTIA SK0-005 Bundle $44.99

100% CompTIA SK0-005 Guaranteed Success With Testking Training Materials

Get Real SK0-005 Exam Questions & Expert Verified Answers as Experienced on the Real Exam!

  • Questions & Answers

    SK0-005 Questions & Answers

    617 Questions & Answers

    The ultimate exam preparation tool, Questions & Answers mirrors the actual SK0-005 exam while allowing you to hone and measure every aspect of your test-taking ability.

  • SK0-005 Video Course

    SK0-005 Video Course

    139 Video Lectures

    SK0-005 Video Course is developed by CompTIA Professionals to help you pass the SK0-005 exam.

    Description

    This course will improve your knowledge and skills required to pass CompTIA Server+ Certification Exam exam.
  • Study Guide

    SK0-005 Study Guide

    533 PDF Pages

    Developed by industry experts, this 533-page guide spells out in painstaking detail all of the information you need to ace SK0-005 exam.

CompTIA Server+ Certification Exam (SK0-005) Practice Tests

Satisfaction Guaranteed

Money Back Guarantee

Testking provides hassle-free money back guarantee with our products. That is because we have 100% trust in the abilities of our professional and experience product team, and our record is a proof of that.

99.6% PASS RATE
Total Cost: $194.97
Bundle Price: $149.98

Purchase Individually

  • Questions & Answers

    Questions & Answers

    617 Questions

    $124.99
  • SK0-005 Video Course

    Video Course

    139 Video Lectures

    $39.99
  • Study Guide

    Study Guide

    533 PDF Pages

    $29.99

CompTIA SK0-005 Practice Test 95

Question 940

A server operations team encounters the following situation: A new CPU cooler has a loose mounting bracket, and server logs show intermittent overheating and unexplained kernel crashes. Which sustained operational control best reduces the likelihood of this same issue recurring?

  1. Check CPU stepping and firmware prerequisites during parts swaps.
  2. Inspect mounting torque and temperature after processor service.
  3. Check seating and retainer locks on shipped servers.
  4. Trend ECC events and retire failing modules before service loss.

Explanation

Correct Answer

B:

This control targets the underlying recurrence risk: Poor heat transfer from the CPU to its cooling assembly causes instability. It builds validation into the affected workflow and supports the expected recovery result: A CPU stress test shows stable temperatures and no spontaneous shutdown.

Incorrect Answers

A:

This control addresses a different scenario: A four-CPU node continues displaying hardware faults after a processor replacement because its BIOS version does not recognize the new CPU stepping. That event's root mechanism was processor revision compatibility depends on firmware support. The described incident instead arises from: Poor heat transfer from the CPU to its cooling assembly causes instability.

C:

This control addresses a different scenario: An expansion NIC appears intermittently after transport, and chassis logs show PCIe link-training failures in the slot. That event's root mechanism was a marginal PCIe card connection disrupts device enumeration. The described incident instead arises from: Poor heat transfer from the CPU to its cooling assembly causes instability.

D:

This control addresses a different scenario: A compute server produces repeated uncorrectable ECC memory errors followed by kernel panics, while its processor temperatures remain normal. That event's root mechanism was uncorrectable RAM faults can cause host crashes independently of thermal conditions. The described incident instead arises from: Poor heat transfer from the CPU to its cooling assembly causes instability.

Question 941

A server operations team encounters the following situation: An expansion NIC appears intermittently after transport, and chassis logs show PCIe link-training failures in the slot. Given the stated symptoms and constraints, which corrective action is the best next step?

  1. Check shared backplane power and connectors before replacing individual drives.
  2. Remove the obstruction and validate the chassis's intended airflow direction.
  3. Test and replace the supported CMOS battery while preserving UEFI settings.
  4. Use ESD-safe servicing to reseat or replace the supported card and inspect its slot.

Explanation

Correct Answer

D:

The preferred corrective action directly addresses the incident: An expansion NIC appears intermittently after transport, and chassis logs show PCIe link-training failures in the slot. The fault mechanism is a marginal PCIe card connection disrupts device enumeration. Expected confirmation is: NIC inventory and link status remain stable across cold starts.

Incorrect Answers

A:

This action is better suited to a separate Given a scenario, troubleshoot common hardware failures incident: A storage chassis reports all eight disks unavailable at once after a backplane power cable was disturbed during maintenance. That case involves: Simultaneous failures across multiple drives point to a shared backplane or power path. Here the observed mechanism is instead: A marginal PCIe card connection disrupts device enumeration. Applying the other repair would not directly resolve this fault.

B:

This action is better suited to a separate Given a scenario, troubleshoot common hardware failures incident: A rack has proper ambient temperature but a specific node overheats after someone places a blanking cover across its rear exhaust. That case involves: Local blocked exhaust can overheat a server even with adequate facility cooling. Here the observed mechanism is instead: A marginal PCIe card connection disrupts device enumeration. Applying the other repair would not directly resolve this fault.

C:

This action is better suited to a separate Given a scenario, troubleshoot common hardware failures incident: A server loses time and boot order whenever rack power is fully isolated, though it behaves normally across OS-only reboots. That case involves: A weak battery fails to preserve persistent real-time clock and firmware values. Here the observed mechanism is instead: A marginal PCIe card connection disrupts device enumeration. Applying the other repair would not directly resolve this fault.

Question 942

A server operations team encounters the following situation: An expansion NIC appears intermittently after transport, and chassis logs show PCIe link-training failures in the slot. After making the corrective change, which result best demonstrates that this particular problem is resolved?

  1. NIC inventory and link status remain stable across cold starts.
  2. Thermal telemetry remains within limits while the application executes.
  3. Replacing the indicated fan clears the active fault and normalizes RPM.
  4. A tested supported DIMM configuration runs without memory controller errors.

Explanation

Correct Answer

A:

This is incident-specific acceptance evidence: NIC inventory and link status remain stable across cold starts. It verifies the action use ESD-safe servicing to reseat or replace the supported card and inspect its slot. The failure under test was: A marginal PCIe card connection disrupts device enumeration.

Incorrect Answers

B:

This observation tests an unrelated Given a scenario, troubleshoot common hardware failures case: A blade's host crashes when its GPU workload starts, but temperature logs reveal rapid GPU overheating and an obstructed air duct. It may be true while the current failure persists; the decisive current cause is: A marginal PCIe card connection disrupts device enumeration.

C:

This observation tests an unrelated Given a scenario, troubleshoot common hardware failures case: A server's chassis LED flags a failed redundant fan, but engineers replace its disk controller based only on unrelated historical alerts. It may be true while the current failure persists; the decisive current cause is: A marginal PCIe card connection disrupts device enumeration.

D:

This observation tests an unrelated Given a scenario, troubleshoot common hardware failures case: A server reports intermittent DRAM faults only when a new memory channel is populated, though each DIMM passes a standalone test. It may be true while the current failure persists; the decisive current cause is: A marginal PCIe card connection disrupts device enumeration.

Question 943

A server operations team encounters the following situation: An expansion NIC appears intermittently after transport, and chassis logs show PCIe link-training failures in the slot. Which underlying cause most specifically explains the observed symptoms?

  1. Unsupported or misconfigured memory prevents hardware initialization.
  2. A marginal PCIe card connection disrupts device enumeration.
  3. Historical unrelated alerts are being mistaken for current fault evidence.
  4. Multi-DIMM electrical loading or a channel fault can appear only in certain populations.

Explanation

Correct Answer

B:

This root-cause explanation directly accounts for the reported condition: An expansion NIC appears intermittently after transport, and chassis logs show PCIe link-training failures in the slot. The corrective step is: Use ESD-safe servicing to reseat or replace the supported card and inspect its slot. The verifying outcome is: NIC inventory and link status remain stable across cold starts.

Incorrect Answers

A:

This alternative cause would explain a different case: A rack server emits repeated POST beep codes and never initializes video after a technician installs unsupported memory DIMMs. It does not explain the actual incident's evidence. The present cause is: A marginal PCIe card connection disrupts device enumeration.

C:

This alternative cause would explain a different case: A server's chassis LED flags a failed redundant fan, but engineers replace its disk controller based only on unrelated historical alerts. It does not explain the actual incident's evidence. The present cause is: A marginal PCIe card connection disrupts device enumeration.

D:

This alternative cause would explain a different case: A server reports intermittent DRAM faults only when a new memory channel is populated, though each DIMM passes a standalone test. It does not explain the actual incident's evidence. The present cause is: A marginal PCIe card connection disrupts device enumeration.

Question 944

A server operations team encounters the following situation: An expansion NIC appears intermittently after transport, and chassis logs show PCIe link-training failures in the slot. Which sustained operational control best reduces the likelihood of this same issue recurring?

  1. Cross-check DIMM speed, rank and placement against vendor HCLs.
  2. Correlate active hardware indicators with maintenance timestamps.
  3. Check seating and retainer locks on shipped servers.
  4. Inspect shared connectors after internal chassis service.

Explanation

Correct Answer

C:

This control targets the underlying recurrence risk: A marginal PCIe card connection disrupts device enumeration. It builds validation into the affected workflow and supports the expected recovery result: NIC inventory and link status remain stable across cold starts.

Incorrect Answers

A:

This control addresses a different scenario: A rack server emits repeated POST beep codes and never initializes video after a technician installs unsupported memory DIMMs. That event's root mechanism was unsupported or misconfigured memory prevents hardware initialization. The described incident instead arises from: A marginal PCIe card connection disrupts device enumeration.

B:

This control addresses a different scenario: A server's chassis LED flags a failed redundant fan, but engineers replace its disk controller based only on unrelated historical alerts. That event's root mechanism was historical unrelated alerts are being mistaken for current fault evidence. The described incident instead arises from: A marginal PCIe card connection disrupts device enumeration.

D:

This control addresses a different scenario: A storage chassis reports all eight disks unavailable at once after a backplane power cable was disturbed during maintenance. That event's root mechanism was simultaneous failures across multiple drives point to a shared backplane or power path. The described incident instead arises from: A marginal PCIe card connection disrupts device enumeration.

Question 945

A server operations team encounters the following situation: A server stops passing POST after a firmware change, and management logs identify an unsupported revision for its RAID adapter. Given the stated symptoms and constraints, which corrective action is the best next step?

  1. Use vendor-supported firmware recovery to restore compatible component versions.
  2. Remove the obstruction and validate the chassis's intended airflow direction.
  3. Diagnose the affected PCIe path, firmware and supported card compatibility.
  4. Apply the minimum vendor-supported firmware for that processor before enabling production use.

Explanation

Correct Answer

A:

The preferred corrective action directly addresses the incident: A server stops passing POST after a firmware change, and management logs identify an unsupported revision for its RAID adapter. The fault mechanism is platform firmware and controller firmware are incompatible. Expected confirmation is: Storage adapter initializes normally and the logical volumes appear unchanged.

Incorrect Answers

B:

This action is better suited to a separate Given a scenario, troubleshoot common hardware failures incident: A rack has proper ambient temperature but a specific node overheats after someone places a blanking cover across its rear exhaust. That case involves: Local blocked exhaust can overheat a server even with adequate facility cooling. Here the observed mechanism is instead: Platform firmware and controller firmware are incompatible. Applying the other repair would not directly resolve this fault.

C:

This action is better suited to a separate Given a scenario, troubleshoot common hardware failures incident: A compute node freezes only when a high-speed NIC transfers data; vendor logs show repeated corrected PCIe bus errors. That case involves: PCIe signal or firmware instability appears under traffic load. Here the observed mechanism is instead: Platform firmware and controller firmware are incompatible. Applying the other repair would not directly resolve this fault.

D:

This action is better suited to a separate Given a scenario, troubleshoot common hardware failures incident: A four-CPU node continues displaying hardware faults after a processor replacement because its BIOS version does not recognize the new CPU stepping. That case involves: Processor revision compatibility depends on firmware support. Here the observed mechanism is instead: Platform firmware and controller firmware are incompatible. Applying the other repair would not directly resolve this fault.

Question 946

A server operations team encounters the following situation: A server stops passing POST after a firmware change, and management logs identify an unsupported revision for its RAID adapter. After making the corrective change, which result best demonstrates that this particular problem is resolved?

  1. The host withstands measured peak load and a controlled single-feed failure.
  2. Storage adapter initializes normally and the logical volumes appear unchanged.
  3. Memory error counters stop increasing and stress testing completes without crashes.
  4. All eight expected physical disks reappear without unnecessary replacements.

Explanation

Correct Answer

B:

This is incident-specific acceptance evidence: Storage adapter initializes normally and the logical volumes appear unchanged. It verifies the action use vendor-supported firmware recovery to restore compatible component versions. The failure under test was: Platform firmware and controller firmware are incompatible.

Incorrect Answers

A:

This observation tests an unrelated Given a scenario, troubleshoot common hardware failures case: A virtualization host suddenly powers off during peak usage, while PSU telemetry shows overload and a degraded redundant supply. It may be true while the current failure persists; the decisive current cause is: Platform firmware and controller firmware are incompatible.

C:

This observation tests an unrelated Given a scenario, troubleshoot common hardware failures case: A compute server produces repeated uncorrectable ECC memory errors followed by kernel panics, while its processor temperatures remain normal. It may be true while the current failure persists; the decisive current cause is: Platform firmware and controller firmware are incompatible.

D:

This observation tests an unrelated Given a scenario, troubleshoot common hardware failures case: A storage chassis reports all eight disks unavailable at once after a backplane power cable was disturbed during maintenance. It may be true while the current failure persists; the decisive current cause is: Platform firmware and controller firmware are incompatible.

Question 947

A server operations team encounters the following situation: A server stops passing POST after a firmware change, and management logs identify an unsupported revision for its RAID adapter. Which underlying cause most specifically explains the observed symptoms?

  1. Local blocked exhaust can overheat a server even with adequate facility cooling.
  2. PCIe signal or firmware instability appears under traffic load.
  3. Platform firmware and controller firmware are incompatible.
  4. A weak battery fails to preserve persistent real-time clock and firmware values.

Explanation

Correct Answer

C:

This root-cause explanation directly accounts for the reported condition: A server stops passing POST after a firmware change, and management logs identify an unsupported revision for its RAID adapter. The corrective step is: Use vendor-supported firmware recovery to restore compatible component versions. The verifying outcome is: Storage adapter initializes normally and the logical volumes appear unchanged.

Incorrect Answers

A:

This alternative cause would explain a different case: A rack has proper ambient temperature but a specific node overheats after someone places a blanking cover across its rear exhaust. It does not explain the actual incident's evidence. The present cause is: Platform firmware and controller firmware are incompatible.

B:

This alternative cause would explain a different case: A compute node freezes only when a high-speed NIC transfers data; vendor logs show repeated corrected PCIe bus errors. It does not explain the actual incident's evidence. The present cause is: Platform firmware and controller firmware are incompatible.

D:

This alternative cause would explain a different case: A server loses time and boot order whenever rack power is fully isolated, though it behaves normally across OS-only reboots. It does not explain the actual incident's evidence. The present cause is: Platform firmware and controller firmware are incompatible.

Question 948

A server operations team encounters the following situation: A server stops passing POST after a firmware change, and management logs identify an unsupported revision for its RAID adapter. Which sustained operational control best reduces the likelihood of this same issue recurring?

  1. Inspect fan maps and sensor health after hardware maintenance.
  2. Validate populated memory layouts rather than testing only individual sticks.
  3. Investigate recurring cold-boot setting resets promptly.
  4. Test firmware dependency matrices before updates.

Explanation

Correct Answer

D:

This control targets the underlying recurrence risk: Platform firmware and controller firmware are incompatible. It builds validation into the affected workflow and supports the expected recovery result: Storage adapter initializes normally and the logical volumes appear unchanged.

Incorrect Answers

A:

This control addresses a different scenario: A server sounds a fan alarm and CPU temperature rises to its throttling threshold after a replacement fan was connected to the wrong header. That event's root mechanism was improper cooling fan placement reduces effective processor airflow. The described incident instead arises from: Platform firmware and controller firmware are incompatible.

B:

This control addresses a different scenario: A server reports intermittent DRAM faults only when a new memory channel is populated, though each DIMM passes a standalone test. That event's root mechanism was multi-DIMM electrical loading or a channel fault can appear only in certain populations. The described incident instead arises from: Platform firmware and controller firmware are incompatible.

C:

This control addresses a different scenario: A server loses time and boot order whenever rack power is fully isolated, though it behaves normally across OS-only reboots. That event's root mechanism was a weak battery fails to preserve persistent real-time clock and firmware values. The described incident instead arises from: Platform firmware and controller firmware are incompatible.

Question 949

A server operations team encounters the following situation: A storage chassis reports all eight disks unavailable at once after a backplane power cable was disturbed during maintenance. Given the stated symptoms and constraints, which corrective action is the best next step?

  1. Reseat the compatible heat sink using manufacturer mounting procedure and thermal material.
  2. Check shared backplane power and connectors before replacing individual drives.
  3. Use vendor-supported firmware recovery to restore compatible component versions.
  4. Use ESD-safe servicing to reseat or replace the supported card and inspect its slot.

Explanation

Correct Answer

B:

The preferred corrective action directly addresses the incident: A storage chassis reports all eight disks unavailable at once after a backplane power cable was disturbed during maintenance. The fault mechanism is simultaneous failures across multiple drives point to a shared backplane or power path. Expected confirmation is: All eight expected physical disks reappear without unnecessary replacements.

Incorrect Answers

A:

This action is better suited to a separate Given a scenario, troubleshoot common hardware failures incident: A new CPU cooler has a loose mounting bracket, and server logs show intermittent overheating and unexplained kernel crashes. That case involves: Poor heat transfer from the CPU to its cooling assembly causes instability. Here the observed mechanism is instead: Simultaneous failures across multiple drives point to a shared backplane or power path. Applying the other repair would not directly resolve this fault.

C:

This action is better suited to a separate Given a scenario, troubleshoot common hardware failures incident: A server stops passing POST after a firmware change, and management logs identify an unsupported revision for its RAID adapter. That case involves: Platform firmware and controller firmware are incompatible. Here the observed mechanism is instead: Simultaneous failures across multiple drives point to a shared backplane or power path. Applying the other repair would not directly resolve this fault.

D:

This action is better suited to a separate Given a scenario, troubleshoot common hardware failures incident: An expansion NIC appears intermittently after transport, and chassis logs show PCIe link-training failures in the slot. That case involves: A marginal PCIe card connection disrupts device enumeration. Here the observed mechanism is instead: Simultaneous failures across multiple drives point to a shared backplane or power path. Applying the other repair would not directly resolve this fault.

Question 950

A server operations team encounters the following situation: A storage chassis reports all eight disks unavailable at once after a backplane power cable was disturbed during maintenance. After making the corrective change, which result best demonstrates that this particular problem is resolved?

  1. Replacing the indicated fan clears the active fault and normalizes RPM.
  2. Memory error counters stop increasing and stress testing completes without crashes.
  3. All eight expected physical disks reappear without unnecessary replacements.
  4. Fan RPM and temperature remain within spec under representative load.

Explanation

Correct Answer

C:

This is incident-specific acceptance evidence: All eight expected physical disks reappear without unnecessary replacements. It verifies the action check shared backplane power and connectors before replacing individual drives. The failure under test was: Simultaneous failures across multiple drives point to a shared backplane or power path.

Incorrect Answers

A:

This observation tests an unrelated Given a scenario, troubleshoot common hardware failures case: A server's chassis LED flags a failed redundant fan, but engineers replace its disk controller based only on unrelated historical alerts. It may be true while the current failure persists; the decisive current cause is: Simultaneous failures across multiple drives point to a shared backplane or power path.

B:

This observation tests an unrelated Given a scenario, troubleshoot common hardware failures case: A compute server produces repeated uncorrectable ECC memory errors followed by kernel panics, while its processor temperatures remain normal. It may be true while the current failure persists; the decisive current cause is: Simultaneous failures across multiple drives point to a shared backplane or power path.

D:

This observation tests an unrelated Given a scenario, troubleshoot common hardware failures case: A server sounds a fan alarm and CPU temperature rises to its throttling threshold after a replacement fan was connected to the wrong header. It may be true while the current failure persists; the decisive current cause is: Simultaneous failures across multiple drives point to a shared backplane or power path.