    Description

    This course will improve your knowledge and skills required to pass CompTIA Server+ Certification Exam exam.
  • Study Guide

    SK0-005 Study Guide

    533 PDF Pages

    Developed by industry experts, this 533-page guide spells out in painstaking detail all of the information you need to ace SK0-005 exam.

CompTIA Server+ Certification Exam (SK0-005) Practice Tests

Satisfaction Guaranteed

Money Back Guarantee

Testking provides hassle-free money back guarantee with our products. That is because we have 100% trust in the abilities of our professional and experience product team, and our record is a proof of that.

99.6% PASS RATE
Total Cost: $194.97
Bundle Price: $149.98

Purchase Individually

  • Questions & Answers

    Questions & Answers

    617 Questions

    $124.99
  • SK0-005 Video Course

    Video Course

    139 Video Lectures

    $39.99
  • Study Guide

    Study Guide

    533 PDF Pages

    $29.99

CompTIA SK0-005 Practice Test 94

Question 930

A server operations team encounters the following situation: A blade's host crashes when its GPU workload starts, but temperature logs reveal rapid GPU overheating and an obstructed air duct. After making the corrective change, which result best demonstrates that this particular problem is resolved?

  1. A CPU stress test shows stable temperatures and no spontaneous shutdown.
  2. Thermal telemetry remains within limits while the application executes.
  3. Memory error counters stop increasing and stress testing completes without crashes.
  4. Fans run within vibration and temperature tolerances after service.

Explanation

Correct Answer

B:

This is incident-specific acceptance evidence: Thermal telemetry remains within limits while the application executes. It verifies the action restore the approved airflow path and retest the GPU cooling system. The failure under test was: The workload exposes insufficient GPU cooling rather than an application-only defect.

Incorrect Answers

A:

This observation tests an unrelated Given a scenario, troubleshoot common hardware failures case: A new CPU cooler has a loose mounting bracket, and server logs show intermittent overheating and unexplained kernel crashes. It may be true while the current failure persists; the decisive current cause is: The workload exposes insufficient GPU cooling rather than an application-only defect.

C:

This observation tests an unrelated Given a scenario, troubleshoot common hardware failures case: A compute server produces repeated uncorrectable ECC memory errors followed by kernel panics, while its processor temperatures remain normal. It may be true while the current failure persists; the decisive current cause is: The workload exposes insufficient GPU cooling rather than an application-only defect.

D:

This observation tests an unrelated Given a scenario, troubleshoot common hardware failures case: A maintenance technician blows dust deeper into server fan bearings with uncontrolled shop compressed air, after which fans vibrate and overheat. It may be true while the current failure persists; the decisive current cause is: The workload exposes insufficient GPU cooling rather than an application-only defect.

Question 931

A server operations team encounters the following situation: A blade's host crashes when its GPU workload starts, but temperature logs reveal rapid GPU overheating and an obstructed air duct. Which underlying cause most specifically explains the observed symptoms?

  1. Historical unrelated alerts are being mistaken for current fault evidence.
  2. Multi-DIMM electrical loading or a channel fault can appear only in certain populations.
  3. The workload exposes insufficient GPU cooling rather than an application-only defect.
  4. A marginal PCIe card connection disrupts device enumeration.

Explanation

Correct Answer

C:

This root-cause explanation directly accounts for the reported condition: A blade's host crashes when its GPU workload starts, but temperature logs reveal rapid GPU overheating and an obstructed air duct. The corrective step is: Restore the approved airflow path and retest the GPU cooling system. The verifying outcome is: Thermal telemetry remains within limits while the application executes.

Incorrect Answers

A:

This alternative cause would explain a different case: A server's chassis LED flags a failed redundant fan, but engineers replace its disk controller based only on unrelated historical alerts. It does not explain the actual incident's evidence. The present cause is: The workload exposes insufficient GPU cooling rather than an application-only defect.

B:

This alternative cause would explain a different case: A server reports intermittent DRAM faults only when a new memory channel is populated, though each DIMM passes a standalone test. It does not explain the actual incident's evidence. The present cause is: The workload exposes insufficient GPU cooling rather than an application-only defect.

D:

This alternative cause would explain a different case: An expansion NIC appears intermittently after transport, and chassis logs show PCIe link-training failures in the slot. It does not explain the actual incident's evidence. The present cause is: The workload exposes insufficient GPU cooling rather than an application-only defect.

Question 932

A server operations team encounters the following situation: A blade's host crashes when its GPU workload starts, but temperature logs reveal rapid GPU overheating and an obstructed air duct. Which sustained operational control best reduces the likelihood of this same issue recurring?

  1. Inspect fan maps and sensor health after hardware maintenance.
  2. Check seating and retainer locks on shipped servers.
  3. Trend ECC events and retire failing modules before service loss.
  4. Include accelerator thermal checks in chassis service acceptance.

Explanation

Correct Answer

D:

This control targets the underlying recurrence risk: The workload exposes insufficient GPU cooling rather than an application-only defect. It builds validation into the affected workflow and supports the expected recovery result: Thermal telemetry remains within limits while the application executes.

Incorrect Answers

A:

This control addresses a different scenario: A server sounds a fan alarm and CPU temperature rises to its throttling threshold after a replacement fan was connected to the wrong header. That event's root mechanism was improper cooling fan placement reduces effective processor airflow. The described incident instead arises from: The workload exposes insufficient GPU cooling rather than an application-only defect.

B:

This control addresses a different scenario: An expansion NIC appears intermittently after transport, and chassis logs show PCIe link-training failures in the slot. That event's root mechanism was a marginal PCIe card connection disrupts device enumeration. The described incident instead arises from: The workload exposes insufficient GPU cooling rather than an application-only defect.

C:

This control addresses a different scenario: A compute server produces repeated uncorrectable ECC memory errors followed by kernel panics, while its processor temperatures remain normal. That event's root mechanism was uncorrectable RAM faults can cause host crashes independently of thermal conditions. The described incident instead arises from: The workload exposes insufficient GPU cooling rather than an application-only defect.

Question 933

A server operations team encounters the following situation: A server loses time and boot order whenever rack power is fully isolated, though it behaves normally across OS-only reboots. Given the stated symptoms and constraints, which corrective action is the best next step?

  1. Check shared backplane power and connectors before replacing individual drives.
  2. Test and replace the supported CMOS battery while preserving UEFI settings.
  3. Use current component sensors and LED fault mapping to confirm the affected fan.
  4. Use ESD-safe servicing to reseat or replace the supported card and inspect its slot.

Explanation

Correct Answer

B:

The preferred corrective action directly addresses the incident: A server loses time and boot order whenever rack power is fully isolated, though it behaves normally across OS-only reboots. The fault mechanism is a weak battery fails to preserve persistent real-time clock and firmware values. Expected confirmation is: Firmware clock and boot priority persist after a full power removal.

Incorrect Answers

A:

This action is better suited to a separate Given a scenario, troubleshoot common hardware failures incident: A storage chassis reports all eight disks unavailable at once after a backplane power cable was disturbed during maintenance. That case involves: Simultaneous failures across multiple drives point to a shared backplane or power path. Here the observed mechanism is instead: A weak battery fails to preserve persistent real-time clock and firmware values. Applying the other repair would not directly resolve this fault.

C:

This action is better suited to a separate Given a scenario, troubleshoot common hardware failures incident: A server's chassis LED flags a failed redundant fan, but engineers replace its disk controller based only on unrelated historical alerts. That case involves: Historical unrelated alerts are being mistaken for current fault evidence. Here the observed mechanism is instead: A weak battery fails to preserve persistent real-time clock and firmware values. Applying the other repair would not directly resolve this fault.

D:

This action is better suited to a separate Given a scenario, troubleshoot common hardware failures incident: An expansion NIC appears intermittently after transport, and chassis logs show PCIe link-training failures in the slot. That case involves: A marginal PCIe card connection disrupts device enumeration. Here the observed mechanism is instead: A weak battery fails to preserve persistent real-time clock and firmware values. Applying the other repair would not directly resolve this fault.

Question 934

A server operations team encounters the following situation: A server loses time and boot order whenever rack power is fully isolated, though it behaves normally across OS-only reboots. After making the corrective change, which result best demonstrates that this particular problem is resolved?

  1. A tested supported DIMM configuration runs without memory controller errors.
  2. POST identifies the processor and passes platform diagnostics.
  3. Firmware clock and boot priority persist after a full power removal.
  4. Replacing the indicated fan clears the active fault and normalizes RPM.

Explanation

Correct Answer

C:

This is incident-specific acceptance evidence: Firmware clock and boot priority persist after a full power removal. It verifies the action test and replace the supported CMOS battery while preserving UEFI settings. The failure under test was: A weak battery fails to preserve persistent real-time clock and firmware values.

Incorrect Answers

A:

This observation tests an unrelated Given a scenario, troubleshoot common hardware failures case: A server reports intermittent DRAM faults only when a new memory channel is populated, though each DIMM passes a standalone test. It may be true while the current failure persists; the decisive current cause is: A weak battery fails to preserve persistent real-time clock and firmware values.

B:

This observation tests an unrelated Given a scenario, troubleshoot common hardware failures case: A four-CPU node continues displaying hardware faults after a processor replacement because its BIOS version does not recognize the new CPU stepping. It may be true while the current failure persists; the decisive current cause is: A weak battery fails to preserve persistent real-time clock and firmware values.

D:

This observation tests an unrelated Given a scenario, troubleshoot common hardware failures case: A server's chassis LED flags a failed redundant fan, but engineers replace its disk controller based only on unrelated historical alerts. It may be true while the current failure persists; the decisive current cause is: A weak battery fails to preserve persistent real-time clock and firmware values.

Question 935

A server operations team encounters the following situation: A server loses time and boot order whenever rack power is fully isolated, though it behaves normally across OS-only reboots. Which underlying cause most specifically explains the observed symptoms?

  1. Improper cleaning can damage fans instead of restoring airflow.
  2. Insufficient remaining power supply capacity leads to shutdown.
  3. Simultaneous failures across multiple drives point to a shared backplane or power path.
  4. A weak battery fails to preserve persistent real-time clock and firmware values.

Explanation

Correct Answer

D:

This root-cause explanation directly accounts for the reported condition: A server loses time and boot order whenever rack power is fully isolated, though it behaves normally across OS-only reboots. The corrective step is: Test and replace the supported CMOS battery while preserving UEFI settings. The verifying outcome is: Firmware clock and boot priority persist after a full power removal.

Incorrect Answers

A:

This alternative cause would explain a different case: A maintenance technician blows dust deeper into server fan bearings with uncontrolled shop compressed air, after which fans vibrate and overheat. It does not explain the actual incident's evidence. The present cause is: A weak battery fails to preserve persistent real-time clock and firmware values.

B:

This alternative cause would explain a different case: A virtualization host suddenly powers off during peak usage, while PSU telemetry shows overload and a degraded redundant supply. It does not explain the actual incident's evidence. The present cause is: A weak battery fails to preserve persistent real-time clock and firmware values.

C:

This alternative cause would explain a different case: A storage chassis reports all eight disks unavailable at once after a backplane power cable was disturbed during maintenance. It does not explain the actual incident's evidence. The present cause is: A weak battery fails to preserve persistent real-time clock and firmware values.

Question 936

A server operations team encounters the following situation: A server loses time and boot order whenever rack power is fully isolated, though it behaves normally across OS-only reboots. Which sustained operational control best reduces the likelihood of this same issue recurring?

  1. Investigate recurring cold-boot setting resets promptly.
  2. Follow approved compressed-air and rotor-control instructions.
  3. Inspect shared connectors after internal chassis service.
  4. Check CPU stepping and firmware prerequisites during parts swaps.

Explanation

Correct Answer

A:

This control targets the underlying recurrence risk: A weak battery fails to preserve persistent real-time clock and firmware values. It builds validation into the affected workflow and supports the expected recovery result: Firmware clock and boot priority persist after a full power removal.

Incorrect Answers

B:

This control addresses a different scenario: A maintenance technician blows dust deeper into server fan bearings with uncontrolled shop compressed air, after which fans vibrate and overheat. That event's root mechanism was improper cleaning can damage fans instead of restoring airflow. The described incident instead arises from: A weak battery fails to preserve persistent real-time clock and firmware values.

C:

This control addresses a different scenario: A storage chassis reports all eight disks unavailable at once after a backplane power cable was disturbed during maintenance. That event's root mechanism was simultaneous failures across multiple drives point to a shared backplane or power path. The described incident instead arises from: A weak battery fails to preserve persistent real-time clock and firmware values.

D:

This control addresses a different scenario: A four-CPU node continues displaying hardware faults after a processor replacement because its BIOS version does not recognize the new CPU stepping. That event's root mechanism was processor revision compatibility depends on firmware support. The described incident instead arises from: A weak battery fails to preserve persistent real-time clock and firmware values.

Question 937

A server operations team encounters the following situation: A new CPU cooler has a loose mounting bracket, and server logs show intermittent overheating and unexplained kernel crashes. Given the stated symptoms and constraints, which corrective action is the best next step?

  1. Correct fan installation and verify thermal control with hardware diagnostics.
  2. Consult model POST diagnostics and replace DIMMs with supported parts.
  3. Reseat the compatible heat sink using manufacturer mounting procedure and thermal material.
  4. Restore the approved airflow path and retest the GPU cooling system.

Explanation

Correct Answer

C:

The preferred corrective action directly addresses the incident: A new CPU cooler has a loose mounting bracket, and server logs show intermittent overheating and unexplained kernel crashes. The fault mechanism is poor heat transfer from the CPU to its cooling assembly causes instability. Expected confirmation is: A CPU stress test shows stable temperatures and no spontaneous shutdown.

Incorrect Answers

A:

This action is better suited to a separate Given a scenario, troubleshoot common hardware failures incident: A server sounds a fan alarm and CPU temperature rises to its throttling threshold after a replacement fan was connected to the wrong header. That case involves: Improper cooling fan placement reduces effective processor airflow. Here the observed mechanism is instead: Poor heat transfer from the CPU to its cooling assembly causes instability. Applying the other repair would not directly resolve this fault.

B:

This action is better suited to a separate Given a scenario, troubleshoot common hardware failures incident: A rack server emits repeated POST beep codes and never initializes video after a technician installs unsupported memory DIMMs. That case involves: Unsupported or misconfigured memory prevents hardware initialization. Here the observed mechanism is instead: Poor heat transfer from the CPU to its cooling assembly causes instability. Applying the other repair would not directly resolve this fault.

D:

This action is better suited to a separate Given a scenario, troubleshoot common hardware failures incident: A blade's host crashes when its GPU workload starts, but temperature logs reveal rapid GPU overheating and an obstructed air duct. That case involves: The workload exposes insufficient GPU cooling rather than an application-only defect. Here the observed mechanism is instead: Poor heat transfer from the CPU to its cooling assembly causes instability. Applying the other repair would not directly resolve this fault.

Question 938

A server operations team encounters the following situation: A new CPU cooler has a loose mounting bracket, and server logs show intermittent overheating and unexplained kernel crashes. After making the corrective change, which result best demonstrates that this particular problem is resolved?

  1. Thermal telemetry remains within limits while the application executes.
  2. All eight expected physical disks reappear without unnecessary replacements.
  3. The host withstands measured peak load and a controlled single-feed failure.
  4. A CPU stress test shows stable temperatures and no spontaneous shutdown.

Explanation

Correct Answer

D:

This is incident-specific acceptance evidence: A CPU stress test shows stable temperatures and no spontaneous shutdown. It verifies the action reseat the compatible heat sink using manufacturer mounting procedure and thermal material. The failure under test was: Poor heat transfer from the CPU to its cooling assembly causes instability.

Incorrect Answers

A:

This observation tests an unrelated Given a scenario, troubleshoot common hardware failures case: A blade's host crashes when its GPU workload starts, but temperature logs reveal rapid GPU overheating and an obstructed air duct. It may be true while the current failure persists; the decisive current cause is: Poor heat transfer from the CPU to its cooling assembly causes instability.

B:

This observation tests an unrelated Given a scenario, troubleshoot common hardware failures case: A storage chassis reports all eight disks unavailable at once after a backplane power cable was disturbed during maintenance. It may be true while the current failure persists; the decisive current cause is: Poor heat transfer from the CPU to its cooling assembly causes instability.

C:

This observation tests an unrelated Given a scenario, troubleshoot common hardware failures case: A virtualization host suddenly powers off during peak usage, while PSU telemetry shows overload and a degraded redundant supply. It may be true while the current failure persists; the decisive current cause is: Poor heat transfer from the CPU to its cooling assembly causes instability.

Question 939

A server operations team encounters the following situation: A new CPU cooler has a loose mounting bracket, and server logs show intermittent overheating and unexplained kernel crashes. Which underlying cause most specifically explains the observed symptoms?

  1. Poor heat transfer from the CPU to its cooling assembly causes instability.
  2. Uncorrectable RAM faults can cause host crashes independently of thermal conditions.
  3. A marginal PCIe card connection disrupts device enumeration.
  4. Platform firmware and controller firmware are incompatible.

Explanation

Correct Answer

A:

This root-cause explanation directly accounts for the reported condition: A new CPU cooler has a loose mounting bracket, and server logs show intermittent overheating and unexplained kernel crashes. The corrective step is: Reseat the compatible heat sink using manufacturer mounting procedure and thermal material. The verifying outcome is: A CPU stress test shows stable temperatures and no spontaneous shutdown.

Incorrect Answers

B:

This alternative cause would explain a different case: A compute server produces repeated uncorrectable ECC memory errors followed by kernel panics, while its processor temperatures remain normal. It does not explain the actual incident's evidence. The present cause is: Poor heat transfer from the CPU to its cooling assembly causes instability.

C:

This alternative cause would explain a different case: An expansion NIC appears intermittently after transport, and chassis logs show PCIe link-training failures in the slot. It does not explain the actual incident's evidence. The present cause is: Poor heat transfer from the CPU to its cooling assembly causes instability.

D:

This alternative cause would explain a different case: A server stops passing POST after a firmware change, and management logs identify an unsupported revision for its RAID adapter. It does not explain the actual incident's evidence. The present cause is: Poor heat transfer from the CPU to its cooling assembly causes instability.

Question 940

A server operations team encounters the following situation: A new CPU cooler has a loose mounting bracket, and server logs show intermittent overheating and unexplained kernel crashes. Which sustained operational control best reduces the likelihood of this same issue recurring?

  1. Check CPU stepping and firmware prerequisites during parts swaps.
  2. Inspect mounting torque and temperature after processor service.
  3. Check seating and retainer locks on shipped servers.
  4. Trend ECC events and retire failing modules before service loss.

Explanation

Correct Answer

B:

This control targets the underlying recurrence risk: Poor heat transfer from the CPU to its cooling assembly causes instability. It builds validation into the affected workflow and supports the expected recovery result: A CPU stress test shows stable temperatures and no spontaneous shutdown.

Incorrect Answers

A:

This control addresses a different scenario: A four-CPU node continues displaying hardware faults after a processor replacement because its BIOS version does not recognize the new CPU stepping. That event's root mechanism was processor revision compatibility depends on firmware support. The described incident instead arises from: Poor heat transfer from the CPU to its cooling assembly causes instability.

C:

This control addresses a different scenario: An expansion NIC appears intermittently after transport, and chassis logs show PCIe link-training failures in the slot. That event's root mechanism was a marginal PCIe card connection disrupts device enumeration. The described incident instead arises from: Poor heat transfer from the CPU to its cooling assembly causes instability.

D:

This control addresses a different scenario: A compute server produces repeated uncorrectable ECC memory errors followed by kernel panics, while its processor temperatures remain normal. That event's root mechanism was uncorrectable RAM faults can cause host crashes independently of thermal conditions. The described incident instead arises from: Poor heat transfer from the CPU to its cooling assembly causes instability.