McAfee-Secured Website

Exam Bundle

Exam Code: SK0-005

Exam Name CompTIA Server+ Certification Exam

Certification Provider: CompTIA

Corresponding Certification: CompTIA Server+

CompTIA SK0-005 Bundle $44.99

100% CompTIA SK0-005 Guaranteed Success With Testking Training Materials

Get Real SK0-005 Exam Questions & Expert Verified Answers as Experienced on the Real Exam!

  • Questions & Answers

    SK0-005 Questions & Answers

    617 Questions & Answers

    The ultimate exam preparation tool, Questions & Answers mirrors the actual SK0-005 exam while allowing you to hone and measure every aspect of your test-taking ability.

  • SK0-005 Video Course

    SK0-005 Video Course

    139 Video Lectures

    SK0-005 Video Course is developed by CompTIA Professionals to help you pass the SK0-005 exam.

    Description

    This course will improve your knowledge and skills required to pass CompTIA Server+ Certification Exam exam.
  • Study Guide

    SK0-005 Study Guide

    533 PDF Pages

    Developed by industry experts, this 533-page guide spells out in painstaking detail all of the information you need to ace SK0-005 exam.

CompTIA Server+ Certification Exam (SK0-005) Practice Tests

Satisfaction Guaranteed

Money Back Guarantee

Testking provides hassle-free money back guarantee with our products. That is because we have 100% trust in the abilities of our professional and experience product team, and our record is a proof of that.

99.6% PASS RATE
Total Cost: $194.97
Bundle Price: $149.98

Purchase Individually

  • Questions & Answers

    Questions & Answers

    617 Questions

    $124.99
  • SK0-005 Video Course

    Video Course

    139 Video Lectures

    $39.99
  • Study Guide

    Study Guide

    533 PDF Pages

    $29.99

CompTIA SK0-005 Practice Test 93

Question 920

A server operations team encounters the following situation: A server sounds a fan alarm and CPU temperature rises to its throttling threshold after a replacement fan was connected to the wrong header. Which sustained operational control best reduces the likelihood of this same issue recurring?

  1. Inspect fan maps and sensor health after hardware maintenance.
  2. Check seating and retainer locks on shipped servers.
  3. Investigate recurring cold-boot setting resets promptly.
  4. Correlate active hardware indicators with maintenance timestamps.

Explanation

Correct Answer

A:

This control targets the underlying recurrence risk: Improper cooling fan placement reduces effective processor airflow. It builds validation into the affected workflow and supports the expected recovery result: Fan RPM and temperature remain within spec under representative load.

Incorrect Answers

B:

This control addresses a different scenario: An expansion NIC appears intermittently after transport, and chassis logs show PCIe link-training failures in the slot. That event's root mechanism was a marginal PCIe card connection disrupts device enumeration. The described incident instead arises from: Improper cooling fan placement reduces effective processor airflow.

C:

This control addresses a different scenario: A server loses time and boot order whenever rack power is fully isolated, though it behaves normally across OS-only reboots. That event's root mechanism was a weak battery fails to preserve persistent real-time clock and firmware values. The described incident instead arises from: Improper cooling fan placement reduces effective processor airflow.

D:

This control addresses a different scenario: A server's chassis LED flags a failed redundant fan, but engineers replace its disk controller based only on unrelated historical alerts. That event's root mechanism was historical unrelated alerts are being mistaken for current fault evidence. The described incident instead arises from: Improper cooling fan placement reduces effective processor airflow.

Question 921

A server operations team encounters the following situation: A virtualization host suddenly powers off during peak usage, while PSU telemetry shows overload and a degraded redundant supply. Given the stated symptoms and constraints, which corrective action is the best next step?

  1. Apply the minimum vendor-supported firmware for that processor before enabling production use.
  2. Check shared backplane power and connectors before replacing individual drives.
  3. Restore compatible PSU redundancy and verify load within safe rated power.
  4. Restore the approved airflow path and retest the GPU cooling system.

Explanation

Correct Answer

C:

The preferred corrective action directly addresses the incident: A virtualization host suddenly powers off during peak usage, while PSU telemetry shows overload and a degraded redundant supply. The fault mechanism is insufficient remaining power supply capacity leads to shutdown. Expected confirmation is: The host withstands measured peak load and a controlled single-feed failure.

Incorrect Answers

A:

This action is better suited to a separate Given a scenario, troubleshoot common hardware failures incident: A four-CPU node continues displaying hardware faults after a processor replacement because its BIOS version does not recognize the new CPU stepping. That case involves: Processor revision compatibility depends on firmware support. Here the observed mechanism is instead: Insufficient remaining power supply capacity leads to shutdown. Applying the other repair would not directly resolve this fault.

B:

This action is better suited to a separate Given a scenario, troubleshoot common hardware failures incident: A storage chassis reports all eight disks unavailable at once after a backplane power cable was disturbed during maintenance. That case involves: Simultaneous failures across multiple drives point to a shared backplane or power path. Here the observed mechanism is instead: Insufficient remaining power supply capacity leads to shutdown. Applying the other repair would not directly resolve this fault.

D:

This action is better suited to a separate Given a scenario, troubleshoot common hardware failures incident: A blade's host crashes when its GPU workload starts, but temperature logs reveal rapid GPU overheating and an obstructed air duct. That case involves: The workload exposes insufficient GPU cooling rather than an application-only defect. Here the observed mechanism is instead: Insufficient remaining power supply capacity leads to shutdown. Applying the other repair would not directly resolve this fault.

Question 922

A server operations team encounters the following situation: A virtualization host suddenly powers off during peak usage, while PSU telemetry shows overload and a degraded redundant supply. After making the corrective change, which result best demonstrates that this particular problem is resolved?

  1. Memory error counters stop increasing and stress testing completes without crashes.
  2. The system completes POST and reports the intended memory capacity.
  3. The node temperature normalizes under the same room conditions.
  4. The host withstands measured peak load and a controlled single-feed failure.

Explanation

Correct Answer

D:

This is incident-specific acceptance evidence: The host withstands measured peak load and a controlled single-feed failure. It verifies the action restore compatible PSU redundancy and verify load within safe rated power. The failure under test was: Insufficient remaining power supply capacity leads to shutdown.

Incorrect Answers

A:

This observation tests an unrelated Given a scenario, troubleshoot common hardware failures case: A compute server produces repeated uncorrectable ECC memory errors followed by kernel panics, while its processor temperatures remain normal. It may be true while the current failure persists; the decisive current cause is: Insufficient remaining power supply capacity leads to shutdown.

B:

This observation tests an unrelated Given a scenario, troubleshoot common hardware failures case: A rack server emits repeated POST beep codes and never initializes video after a technician installs unsupported memory DIMMs. It may be true while the current failure persists; the decisive current cause is: Insufficient remaining power supply capacity leads to shutdown.

C:

This observation tests an unrelated Given a scenario, troubleshoot common hardware failures case: A rack has proper ambient temperature but a specific node overheats after someone places a blanking cover across its rear exhaust. It may be true while the current failure persists; the decisive current cause is: Insufficient remaining power supply capacity leads to shutdown.

Question 923

A server operations team encounters the following situation: A virtualization host suddenly powers off during peak usage, while PSU telemetry shows overload and a degraded redundant supply. Which underlying cause most specifically explains the observed symptoms?

  1. Insufficient remaining power supply capacity leads to shutdown.
  2. Unsupported or misconfigured memory prevents hardware initialization.
  3. PCIe signal or firmware instability appears under traffic load.
  4. Poor heat transfer from the CPU to its cooling assembly causes instability.

Explanation

Correct Answer

A:

This root-cause explanation directly accounts for the reported condition: A virtualization host suddenly powers off during peak usage, while PSU telemetry shows overload and a degraded redundant supply. The corrective step is: Restore compatible PSU redundancy and verify load within safe rated power. The verifying outcome is: The host withstands measured peak load and a controlled single-feed failure.

Incorrect Answers

B:

This alternative cause would explain a different case: A rack server emits repeated POST beep codes and never initializes video after a technician installs unsupported memory DIMMs. It does not explain the actual incident's evidence. The present cause is: Insufficient remaining power supply capacity leads to shutdown.

C:

This alternative cause would explain a different case: A compute node freezes only when a high-speed NIC transfers data; vendor logs show repeated corrected PCIe bus errors. It does not explain the actual incident's evidence. The present cause is: Insufficient remaining power supply capacity leads to shutdown.

D:

This alternative cause would explain a different case: A new CPU cooler has a loose mounting bracket, and server logs show intermittent overheating and unexplained kernel crashes. It does not explain the actual incident's evidence. The present cause is: Insufficient remaining power supply capacity leads to shutdown.

Question 924

A server operations team encounters the following situation: A virtualization host suddenly powers off during peak usage, while PSU telemetry shows overload and a degraded redundant supply. Which sustained operational control best reduces the likelihood of this same issue recurring?

  1. Trend ECC events and retire failing modules before service loss.
  2. Monitor per-supply health and rack electrical headroom.
  3. Inspect fan maps and sensor health after hardware maintenance.
  4. Correlate active hardware indicators with maintenance timestamps.

Explanation

Correct Answer

B:

This control targets the underlying recurrence risk: Insufficient remaining power supply capacity leads to shutdown. It builds validation into the affected workflow and supports the expected recovery result: The host withstands measured peak load and a controlled single-feed failure.

Incorrect Answers

A:

This control addresses a different scenario: A compute server produces repeated uncorrectable ECC memory errors followed by kernel panics, while its processor temperatures remain normal. That event's root mechanism was uncorrectable RAM faults can cause host crashes independently of thermal conditions. The described incident instead arises from: Insufficient remaining power supply capacity leads to shutdown.

C:

This control addresses a different scenario: A server sounds a fan alarm and CPU temperature rises to its throttling threshold after a replacement fan was connected to the wrong header. That event's root mechanism was improper cooling fan placement reduces effective processor airflow. The described incident instead arises from: Insufficient remaining power supply capacity leads to shutdown.

D:

This control addresses a different scenario: A server's chassis LED flags a failed redundant fan, but engineers replace its disk controller based only on unrelated historical alerts. That event's root mechanism was historical unrelated alerts are being mistaken for current fault evidence. The described incident instead arises from: Insufficient remaining power supply capacity leads to shutdown.

Question 925

A server operations team encounters the following situation: A rack server emits repeated POST beep codes and never initializes video after a technician installs unsupported memory DIMMs. Given the stated symptoms and constraints, which corrective action is the best next step?

  1. Apply the minimum vendor-supported firmware for that processor before enabling production use.
  2. Use vendor-approved ESD-safe cleaning and replace damaged cooling components.
  3. Check shared backplane power and connectors before replacing individual drives.
  4. Consult model POST diagnostics and replace DIMMs with supported parts.

Explanation

Correct Answer

D:

The preferred corrective action directly addresses the incident: A rack server emits repeated POST beep codes and never initializes video after a technician installs unsupported memory DIMMs. The fault mechanism is unsupported or misconfigured memory prevents hardware initialization. Expected confirmation is: The system completes POST and reports the intended memory capacity.

Incorrect Answers

A:

This action is better suited to a separate Given a scenario, troubleshoot common hardware failures incident: A four-CPU node continues displaying hardware faults after a processor replacement because its BIOS version does not recognize the new CPU stepping. That case involves: Processor revision compatibility depends on firmware support. Here the observed mechanism is instead: Unsupported or misconfigured memory prevents hardware initialization. Applying the other repair would not directly resolve this fault.

B:

This action is better suited to a separate Given a scenario, troubleshoot common hardware failures incident: A maintenance technician blows dust deeper into server fan bearings with uncontrolled shop compressed air, after which fans vibrate and overheat. That case involves: Improper cleaning can damage fans instead of restoring airflow. Here the observed mechanism is instead: Unsupported or misconfigured memory prevents hardware initialization. Applying the other repair would not directly resolve this fault.

C:

This action is better suited to a separate Given a scenario, troubleshoot common hardware failures incident: A storage chassis reports all eight disks unavailable at once after a backplane power cable was disturbed during maintenance. That case involves: Simultaneous failures across multiple drives point to a shared backplane or power path. Here the observed mechanism is instead: Unsupported or misconfigured memory prevents hardware initialization. Applying the other repair would not directly resolve this fault.

Question 926

A server operations team encounters the following situation: A rack server emits repeated POST beep codes and never initializes video after a technician installs unsupported memory DIMMs. After making the corrective change, which result best demonstrates that this particular problem is resolved?

  1. The system completes POST and reports the intended memory capacity.
  2. A tested supported DIMM configuration runs without memory controller errors.
  3. Sustained link testing completes without the relevant corrected-error storm.
  4. The host withstands measured peak load and a controlled single-feed failure.

Explanation

Correct Answer

A:

This is incident-specific acceptance evidence: The system completes POST and reports the intended memory capacity. It verifies the action consult model POST diagnostics and replace DIMMs with supported parts. The failure under test was: Unsupported or misconfigured memory prevents hardware initialization.

Incorrect Answers

B:

This observation tests an unrelated Given a scenario, troubleshoot common hardware failures case: A server reports intermittent DRAM faults only when a new memory channel is populated, though each DIMM passes a standalone test. It may be true while the current failure persists; the decisive current cause is: Unsupported or misconfigured memory prevents hardware initialization.

C:

This observation tests an unrelated Given a scenario, troubleshoot common hardware failures case: A compute node freezes only when a high-speed NIC transfers data; vendor logs show repeated corrected PCIe bus errors. It may be true while the current failure persists; the decisive current cause is: Unsupported or misconfigured memory prevents hardware initialization.

D:

This observation tests an unrelated Given a scenario, troubleshoot common hardware failures case: A virtualization host suddenly powers off during peak usage, while PSU telemetry shows overload and a degraded redundant supply. It may be true while the current failure persists; the decisive current cause is: Unsupported or misconfigured memory prevents hardware initialization.

Question 927

A server operations team encounters the following situation: A rack server emits repeated POST beep codes and never initializes video after a technician installs unsupported memory DIMMs. Which underlying cause most specifically explains the observed symptoms?

  1. Local blocked exhaust can overheat a server even with adequate facility cooling.
  2. Unsupported or misconfigured memory prevents hardware initialization.
  3. Uncorrectable RAM faults can cause host crashes independently of thermal conditions.
  4. PCIe signal or firmware instability appears under traffic load.

Explanation

Correct Answer

B:

This root-cause explanation directly accounts for the reported condition: A rack server emits repeated POST beep codes and never initializes video after a technician installs unsupported memory DIMMs. The corrective step is: Consult model POST diagnostics and replace DIMMs with supported parts. The verifying outcome is: The system completes POST and reports the intended memory capacity.

Incorrect Answers

A:

This alternative cause would explain a different case: A rack has proper ambient temperature but a specific node overheats after someone places a blanking cover across its rear exhaust. It does not explain the actual incident's evidence. The present cause is: Unsupported or misconfigured memory prevents hardware initialization.

C:

This alternative cause would explain a different case: A compute server produces repeated uncorrectable ECC memory errors followed by kernel panics, while its processor temperatures remain normal. It does not explain the actual incident's evidence. The present cause is: Unsupported or misconfigured memory prevents hardware initialization.

D:

This alternative cause would explain a different case: A compute node freezes only when a high-speed NIC transfers data; vendor logs show repeated corrected PCIe bus errors. It does not explain the actual incident's evidence. The present cause is: Unsupported or misconfigured memory prevents hardware initialization.

Question 928

A server operations team encounters the following situation: A rack server emits repeated POST beep codes and never initializes video after a technician installs unsupported memory DIMMs. Which sustained operational control best reduces the likelihood of this same issue recurring?

  1. Check chassis clearances during rack cable and panel maintenance.
  2. Trend ECC events and retire failing modules before service loss.
  3. Cross-check DIMM speed, rank and placement against vendor HCLs.
  4. Check seating and retainer locks on shipped servers.

Explanation

Correct Answer

C:

This control targets the underlying recurrence risk: Unsupported or misconfigured memory prevents hardware initialization. It builds validation into the affected workflow and supports the expected recovery result: The system completes POST and reports the intended memory capacity.

Incorrect Answers

A:

This control addresses a different scenario: A rack has proper ambient temperature but a specific node overheats after someone places a blanking cover across its rear exhaust. That event's root mechanism was local blocked exhaust can overheat a server even with adequate facility cooling. The described incident instead arises from: Unsupported or misconfigured memory prevents hardware initialization.

B:

This control addresses a different scenario: A compute server produces repeated uncorrectable ECC memory errors followed by kernel panics, while its processor temperatures remain normal. That event's root mechanism was uncorrectable RAM faults can cause host crashes independently of thermal conditions. The described incident instead arises from: Unsupported or misconfigured memory prevents hardware initialization.

D:

This control addresses a different scenario: An expansion NIC appears intermittently after transport, and chassis logs show PCIe link-training failures in the slot. That event's root mechanism was a marginal PCIe card connection disrupts device enumeration. The described incident instead arises from: Unsupported or misconfigured memory prevents hardware initialization.

Question 929

A server operations team encounters the following situation: A blade's host crashes when its GPU workload starts, but temperature logs reveal rapid GPU overheating and an obstructed air duct. Given the stated symptoms and constraints, which corrective action is the best next step?

  1. Restore the approved airflow path and retest the GPU cooling system.
  2. Test and replace the supported CMOS battery while preserving UEFI settings.
  3. Reseat the compatible heat sink using manufacturer mounting procedure and thermal material.
  4. Use vendor diagnostics to isolate and replace the failed memory module or channel.

Explanation

Correct Answer

A:

The preferred corrective action directly addresses the incident: A blade's host crashes when its GPU workload starts, but temperature logs reveal rapid GPU overheating and an obstructed air duct. The fault mechanism is the workload exposes insufficient GPU cooling rather than an application-only defect. Expected confirmation is: Thermal telemetry remains within limits while the application executes.

Incorrect Answers

B:

This action is better suited to a separate Given a scenario, troubleshoot common hardware failures incident: A server loses time and boot order whenever rack power is fully isolated, though it behaves normally across OS-only reboots. That case involves: A weak battery fails to preserve persistent real-time clock and firmware values. Here the observed mechanism is instead: The workload exposes insufficient GPU cooling rather than an application-only defect. Applying the other repair would not directly resolve this fault.

C:

This action is better suited to a separate Given a scenario, troubleshoot common hardware failures incident: A new CPU cooler has a loose mounting bracket, and server logs show intermittent overheating and unexplained kernel crashes. That case involves: Poor heat transfer from the CPU to its cooling assembly causes instability. Here the observed mechanism is instead: The workload exposes insufficient GPU cooling rather than an application-only defect. Applying the other repair would not directly resolve this fault.

D:

This action is better suited to a separate Given a scenario, troubleshoot common hardware failures incident: A compute server produces repeated uncorrectable ECC memory errors followed by kernel panics, while its processor temperatures remain normal. That case involves: Uncorrectable RAM faults can cause host crashes independently of thermal conditions. Here the observed mechanism is instead: The workload exposes insufficient GPU cooling rather than an application-only defect. Applying the other repair would not directly resolve this fault.

Question 930

A server operations team encounters the following situation: A blade's host crashes when its GPU workload starts, but temperature logs reveal rapid GPU overheating and an obstructed air duct. After making the corrective change, which result best demonstrates that this particular problem is resolved?

  1. A CPU stress test shows stable temperatures and no spontaneous shutdown.
  2. Thermal telemetry remains within limits while the application executes.
  3. Memory error counters stop increasing and stress testing completes without crashes.
  4. Fans run within vibration and temperature tolerances after service.

Explanation

Correct Answer

B:

This is incident-specific acceptance evidence: Thermal telemetry remains within limits while the application executes. It verifies the action restore the approved airflow path and retest the GPU cooling system. The failure under test was: The workload exposes insufficient GPU cooling rather than an application-only defect.

Incorrect Answers

A:

This observation tests an unrelated Given a scenario, troubleshoot common hardware failures case: A new CPU cooler has a loose mounting bracket, and server logs show intermittent overheating and unexplained kernel crashes. It may be true while the current failure persists; the decisive current cause is: The workload exposes insufficient GPU cooling rather than an application-only defect.

C:

This observation tests an unrelated Given a scenario, troubleshoot common hardware failures case: A compute server produces repeated uncorrectable ECC memory errors followed by kernel panics, while its processor temperatures remain normal. It may be true while the current failure persists; the decisive current cause is: The workload exposes insufficient GPU cooling rather than an application-only defect.

D:

This observation tests an unrelated Given a scenario, troubleshoot common hardware failures case: A maintenance technician blows dust deeper into server fan bearings with uncontrolled shop compressed air, after which fans vibrate and overheat. It may be true while the current failure persists; the decisive current cause is: The workload exposes insufficient GPU cooling rather than an application-only defect.