McAfee-Secured Website

Exam Bundle

Exam Code: SK0-005

Exam Name CompTIA Server+ Certification Exam

Certification Provider: CompTIA

Corresponding Certification: CompTIA Server+

CompTIA SK0-005 Bundle $44.99

100% CompTIA SK0-005 Guaranteed Success With Testking Training Materials

Get Real SK0-005 Exam Questions & Expert Verified Answers as Experienced on the Real Exam!

  • Questions & Answers

    SK0-005 Questions & Answers

    617 Questions & Answers

    The ultimate exam preparation tool, Questions & Answers mirrors the actual SK0-005 exam while allowing you to hone and measure every aspect of your test-taking ability.

  • SK0-005 Video Course

    SK0-005 Video Course

    139 Video Lectures

    SK0-005 Video Course is developed by CompTIA Professionals to help you pass the SK0-005 exam.

    Description

    This course will improve your knowledge and skills required to pass CompTIA Server+ Certification Exam exam.
  • Study Guide

    SK0-005 Study Guide

    533 PDF Pages

    Developed by industry experts, this 533-page guide spells out in painstaking detail all of the information you need to ace SK0-005 exam.

CompTIA Server+ Certification Exam (SK0-005) Practice Tests

Satisfaction Guaranteed

Money Back Guarantee

Testking provides hassle-free money back guarantee with our products. That is because we have 100% trust in the abilities of our professional and experience product team, and our record is a proof of that.

99.6% PASS RATE
Total Cost: $194.97
Bundle Price: $149.98

Purchase Individually

  • Questions & Answers

    Questions & Answers

    617 Questions

    $124.99
  • SK0-005 Video Course

    Video Course

    139 Video Lectures

    $39.99
  • Study Guide

    Study Guide

    533 PDF Pages

    $29.99

CompTIA SK0-005 Practice Test 8

Question 70

A server operations team encounters the following situation: An expansion server needs four network ports, but the small-form chassis lacks enough PCIe slots for the specified add-in NICs. After making the corrective change, which result best demonstrates that this particular problem is resolved?

  1. POST and hardware inventory recognize the approved GPU after installation.
  2. A load test demonstrates the declared time to orderly shutdown.
  3. All four network paths enumerate and carry approved traffic after installation.
  4. Cable certification and port error counters meet the link acceptance criteria.

Explanation

Correct Answer

C:

This is incident-specific acceptance evidence: All four network paths enumerate and carry approved traffic after installation. It verifies the action choose a supported onboard or compatible multiport NIC configuration before ordering. The failure under test was: The proposed physical expansion count exceeds chassis slot capacity.

Incorrect Answers

A:

This observation tests an unrelated Given a scenario, install physical hardware case: A rack-mount GPU server requires a PCIe slot layout unsupported by the selected motherboard revision, although its CPU count is adequate. It may be true while the current failure persists; the decisive current cause is: The proposed physical expansion count exceeds chassis slot capacity.

B:

This observation tests an unrelated Given a scenario, install physical hardware case: One site's new rack consumes more power than two UPS battery strings can support for the required graceful shutdown window. It may be true while the current failure persists; the decisive current cause is: The proposed physical expansion count exceeds chassis slot capacity.

D:

This observation tests an unrelated Given a scenario, install physical hardware case: Technicians use a consumer patch cable for a 10GbE run longer than its specified distance and see frequent cyclic redundancy errors. It may be true while the current failure persists; the decisive current cause is: The proposed physical expansion count exceeds chassis slot capacity.

Question 71

A server operations team encounters the following situation: An expansion server needs four network ports, but the small-form chassis lacks enough PCIe slots for the specified add-in NICs. Which underlying cause most specifically explains the observed symptoms?

  1. Physical connector compatibility is required in addition to optical signal compatibility.
  2. Processor capacity does not establish PCIe mechanical and electrical compatibility.
  3. The chosen console access workflow is not operationally maintainable.
  4. The proposed physical expansion count exceeds chassis slot capacity.

Explanation

Correct Answer

D:

This root-cause explanation directly accounts for the reported condition: An expansion server needs four network ports, but the small-form chassis lacks enough PCIe slots for the specified add-in NICs. The corrective step is: Choose a supported onboard or compatible multiport NIC configuration before ordering. The verifying outcome is: All four network paths enumerate and carry approved traffic after installation.

Incorrect Answers

A:

This alternative cause would explain a different case: A mixed-fiber patch panel uses LC duplex ports but the ordered switch transceivers expect an unrelated connector type. It does not explain the actual incident's evidence. The present cause is: The proposed physical expansion count exceeds chassis slot capacity.

B:

This alternative cause would explain a different case: A rack-mount GPU server requires a PCIe slot layout unsupported by the selected motherboard revision, although its CPU count is adequate. It does not explain the actual incident's evidence. The present cause is: The proposed physical expansion count exceeds chassis slot capacity.

C:

This alternative cause would explain a different case: A new remote rack has a KVM console accessible only by disconnecting active production monitor cables. It does not explain the actual incident's evidence. The present cause is: The proposed physical expansion count exceeds chassis slot capacity.

Question 72

A server operations team encounters the following situation: An expansion server needs four network ports, but the small-form chassis lacks enough PCIe slots for the specified add-in NICs. Which sustained operational control best reduces the likelihood of this same issue recurring?

  1. Cross-check HCL expansion-slot and port counts before purchase.
  2. Validate physical rack elevations against each incoming chassis dimension.
  3. Keep optical part numbers tied to port speed requirements.
  4. Record rack-post type and chassis rail compatibility in procurement checks.

Explanation

Correct Answer

A:

This control targets the underlying recurrence risk: The proposed physical expansion count exceeds chassis slot capacity. It builds validation into the affected workflow and supports the expected recovery result: All four network paths enumerate and carry approved traffic after installation.

Incorrect Answers

B:

This control addresses a different scenario: A hospital orders 4U blade enclosures but the existing 24U rack has only 2U contiguous free space near its reserved airflow corridor. That event's root mechanism was available total units do not imply an enclosure can occupy fragmented rack space. The described incident instead arises from: The proposed physical expansion count exceeds chassis slot capacity.

C:

This control addresses a different scenario: A new 10GbE NIC is fitted with a 1GbE-only SFP module, and a storage transfer cannot reach its specified link rate. That event's root mechanism was the installed pluggable is not capable of the intended link speed. The described incident instead arises from: The proposed physical expansion count exceeds chassis slot capacity.

D:

This control addresses a different scenario: A new 2U compute node ships with universal sliding rails that do not match the data center's square-hole posts. That event's root mechanism was an incompatible mounting rail cannot provide a verified secure server installation. The described incident instead arises from: The proposed physical expansion count exceeds chassis slot capacity.

Question 73

A server operations team encounters the following situation: A six-disk RAID 5 array is selected for a workload that must survive two simultaneous disk failures during a rebuild. Given the stated symptoms and constraints, which corrective action is the best next step?

  1. Design a supported redundant data-protection scheme instead of treating JBOD as RAID.
  2. Provide a supported SMB/CIFS share with appropriate permissions for the Windows workload.
  3. Use a suitably sized RAID 6 or another validated two-failure-tolerant design.
  4. Configure initiator discovery, target authentication and the required storage network path.

Explanation

Correct Answer

C:

The preferred corrective action directly addresses the incident: A six-disk RAID 5 array is selected for a workload that must survive two simultaneous disk failures during a rebuild. The fault mechanism is single-parity RAID 5 does not protect against two concurrent disk failures. Expected confirmation is: Two controlled drive faults leave the test logical volume available and recoverable.

Incorrect Answers

A:

This action is better suited to a separate Given a scenario, deploy and manage storage incident: A 12-disk JBOD enclosure is described as fault tolerant because it provides a single combined capacity pool. That case involves: JBOD by itself does not supply striping parity or mirroring. Here the observed mechanism is instead: Single-parity RAID 5 does not protect against two concurrent disk failures. Applying the other repair would not directly resolve this fault.

B:

This action is better suited to a separate Given a scenario, deploy and manage storage incident: An NFS export works for Linux clients but a Windows service requiring SMB file locking cannot use the same mount protocol. That case involves: NAS protocols are not equivalent simply because both provide network file access. Here the observed mechanism is instead: Single-parity RAID 5 does not protect against two concurrent disk failures. Applying the other repair would not directly resolve this fault.

D:

This action is better suited to a separate Given a scenario, deploy and manage storage incident: A server is given an iSCSI target IP but never logs in to the target, so the new logical unit is absent in Disk Management. That case involves: Target address entry alone does not establish an iSCSI session or LUN assignment. Here the observed mechanism is instead: Single-parity RAID 5 does not protect against two concurrent disk failures. Applying the other repair would not directly resolve this fault.

Question 74

A server operations team encounters the following situation: A six-disk RAID 5 array is selected for a workload that must survive two simultaneous disk failures during a rebuild. After making the corrective change, which result best demonstrates that this particular problem is resolved?

  1. Controller diagnostics report healthy cache protection and normal write performance.
  2. A representative write workload meets latency targets and survives supported drive failures.
  3. The WWPN logs into the fabric and sees only assigned LUNs.
  4. Two controlled drive faults leave the test logical volume available and recoverable.

Explanation

Correct Answer

D:

This is incident-specific acceptance evidence: Two controlled drive faults leave the test logical volume available and recoverable. It verifies the action use a suitably sized RAID 6 or another validated two-failure-tolerant design. The failure under test was: Single-parity RAID 5 does not protect against two concurrent disk failures.

Incorrect Answers

A:

This observation tests an unrelated Given a scenario, deploy and manage storage case: A RAID array reports write-back cache disabled after its battery protection module failed, and transaction throughput drops sharply. It may be true while the current failure persists; the decisive current cause is: Single-parity RAID 5 does not protect against two concurrent disk failures.

B:

This observation tests an unrelated Given a scenario, deploy and manage storage case: A media server needs mirrored data with high random-write performance, but its chosen RAID 5 group experiences large write penalties. It may be true while the current failure persists; the decisive current cause is: Single-parity RAID 5 does not protect against two concurrent disk failures.

C:

This observation tests an unrelated Given a scenario, deploy and manage storage case: A Fibre Channel host bus adapter is inserted into an Ethernet switch because both ports appear to use small optical connectors. It may be true while the current failure persists; the decisive current cause is: Single-parity RAID 5 does not protect against two concurrent disk failures.

Question 75

A server operations team encounters the following situation: A six-disk RAID 5 array is selected for a workload that must survive two simultaneous disk failures during a rebuild. Which underlying cause most specifically explains the observed symptoms?

  1. Single-parity RAID 5 does not protect against two concurrent disk failures.
  2. Read-oriented flash endurance is unsuitable for the sustained write workload.
  3. Ordinary filesystem drivers cannot safely coordinate unsupervised simultaneous raw block writers.
  4. One portable disk is a fragile single-copy retention strategy.

Explanation

Correct Answer

A:

This root-cause explanation directly accounts for the reported condition: A six-disk RAID 5 array is selected for a workload that must survive two simultaneous disk failures during a rebuild. The corrective step is: Use a suitably sized RAID 6 or another validated two-failure-tolerant design. The verifying outcome is: Two controlled drive faults leave the test logical volume available and recoverable.

Incorrect Answers

B:

This alternative cause would explain a different case: A replacement SSD with lower endurance rating is installed in a high-write logging host, and wear indicators rapidly approach limits. It does not explain the actual incident's evidence. The present cause is: Single-parity RAID 5 does not protect against two concurrent disk failures.

C:

This alternative cause would explain a different case: A SAN volume is assigned to two standalone Windows servers without cluster-aware filesystem controls, and its filesystem becomes corrupt. It does not explain the actual incident's evidence. The present cause is: Single-parity RAID 5 does not protect against two concurrent disk failures.

D:

This alternative cause would explain a different case: A backup server uses a single consumer USB SSD as its only long-term archive, although policy requires durable off-site retention. It does not explain the actual incident's evidence. The present cause is: Single-parity RAID 5 does not protect against two concurrent disk failures.

Question 76

A server operations team encounters the following situation: A six-disk RAID 5 array is selected for a workload that must survive two simultaneous disk failures during a rebuild. Which sustained operational control best reduces the likelihood of this same issue recurring?

  1. Match client operating system and application locking requirements to file-sharing protocol.
  2. Document tolerated failures and rebuild exposure in storage design decisions.
  3. Verify external-storage interfaces against replacement server ports.
  4. Maintain actual used-versus-usable capacity forecasts for storage expansions.

Explanation

Correct Answer

B:

This control targets the underlying recurrence risk: Single-parity RAID 5 does not protect against two concurrent disk failures. It builds validation into the affected workflow and supports the expected recovery result: Two controlled drive faults leave the test logical volume available and recoverable.

Incorrect Answers

A:

This control addresses a different scenario: An NFS export works for Linux clients but a Windows service requiring SMB file locking cannot use the same mount protocol. That event's root mechanism was nAS protocols are not equivalent simply because both provide network file access. The described incident instead arises from: Single-parity RAID 5 does not protect against two concurrent disk failures.

C:

This control addresses a different scenario: A legacy eSATA disk enclosure loses connectivity because the new server exposes only USB and SAS connectors. That event's root mechanism was connectors and protocols for external storage are not universally interchangeable. The described incident instead arises from: Single-parity RAID 5 does not protect against two concurrent disk failures.

D:

This control addresses a different scenario: A capacity planner chooses a raw 24 TB storage shelf for a 22 TB dataset without space for RAID overhead, snapshots or growth. That event's root mechanism was raw nameplate bytes overstate application-usable storage. The described incident instead arises from: Single-parity RAID 5 does not protect against two concurrent disk failures.

Question 77

A server operations team encounters the following situation: A critical database stores its write-ahead log and transaction data in RAID 0 for speed despite requiring continued service after one drive failure. Given the stated symptoms and constraints, which corrective action is the best next step?

  1. Select a write-intensive SSD with supported endurance and capacity for measured daily writes.
  2. Configure initiator discovery, target authentication and the required storage network path.
  3. Right-size read-intensive flash to observed workload and endurance needs.
  4. Migrate to a redundant RAID layout appropriate for database I/O and resilience.

Explanation

Correct Answer

D:

The preferred corrective action directly addresses the incident: A critical database stores its write-ahead log and transaction data in RAID 0 for speed despite requiring continued service after one drive failure. The fault mechanism is striping without redundancy provides no fault tolerance. Expected confirmation is: The service remains available after a simulated single-disk failure.

Incorrect Answers

A:

This action is better suited to a separate Given a scenario, deploy and manage storage incident: A replacement SSD with lower endurance rating is installed in a high-write logging host, and wear indicators rapidly approach limits. That case involves: Read-oriented flash endurance is unsuitable for the sustained write workload. Here the observed mechanism is instead: Striping without redundancy provides no fault tolerance. Applying the other repair would not directly resolve this fault.

B:

This action is better suited to a separate Given a scenario, deploy and manage storage incident: A server is given an iSCSI target IP but never logs in to the target, so the new logical unit is absent in Disk Management. That case involves: Target address entry alone does not establish an iSCSI session or LUN assignment. Here the observed mechanism is instead: Striping without redundancy provides no fault tolerance. Applying the other repair would not directly resolve this fault.

C:

This action is better suited to a separate Given a scenario, deploy and manage storage incident: A high-density read cache uses write-intensive SSDs with excessive cost while backend workloads are predominantly sequential reads. That case involves: Drive endurance classes should match actual read-write patterns rather than blanket maximum ratings. Here the observed mechanism is instead: Striping without redundancy provides no fault tolerance. Applying the other repair would not directly resolve this fault.

Question 78

A server operations team encounters the following situation: A critical database stores its write-ahead log and transaction data in RAID 0 for speed despite requiring continued service after one drive failure. After making the corrective change, which result best demonstrates that this particular problem is resolved?

  1. The service remains available after a simulated single-disk failure.
  2. A controlled member failure does not destroy protected data in the revised design.
  3. Provisioned datasets fit with an explicit reserve after full protection overhead.
  4. A dated archive remains restorable after the local USB device is unavailable.

Explanation

Correct Answer

A:

This is incident-specific acceptance evidence: The service remains available after a simulated single-disk failure. It verifies the action migrate to a redundant RAID layout appropriate for database I/O and resilience. The failure under test was: Striping without redundancy provides no fault tolerance.

Incorrect Answers

B:

This observation tests an unrelated Given a scenario, deploy and manage storage case: A 12-disk JBOD enclosure is described as fault tolerant because it provides a single combined capacity pool. It may be true while the current failure persists; the decisive current cause is: Striping without redundancy provides no fault tolerance.

C:

This observation tests an unrelated Given a scenario, deploy and manage storage case: A capacity planner chooses a raw 24 TB storage shelf for a 22 TB dataset without space for RAID overhead, snapshots or growth. It may be true while the current failure persists; the decisive current cause is: Striping without redundancy provides no fault tolerance.

D:

This observation tests an unrelated Given a scenario, deploy and manage storage case: A backup server uses a single consumer USB SSD as its only long-term archive, although policy requires durable off-site retention. It may be true while the current failure persists; the decisive current cause is: Striping without redundancy provides no fault tolerance.

Question 79

A server operations team encounters the following situation: A critical database stores its write-ahead log and transaction data in RAID 0 for speed despite requiring continued service after one drive failure. Which underlying cause most specifically explains the observed symptoms?

  1. Target address entry alone does not establish an iSCSI session or LUN assignment.
  2. Striping without redundancy provides no fault tolerance.
  3. Drive capacity alone does not guarantee controller, interface or firmware compatibility.
  4. Single-parity RAID 5 does not protect against two concurrent disk failures.

Explanation

Correct Answer

B:

This root-cause explanation directly accounts for the reported condition: A critical database stores its write-ahead log and transaction data in RAID 0 for speed despite requiring continued service after one drive failure. The corrective step is: Migrate to a redundant RAID layout appropriate for database I/O and resilience. The verifying outcome is: The service remains available after a simulated single-disk failure.

Incorrect Answers

A:

This alternative cause would explain a different case: A server is given an iSCSI target IP but never logs in to the target, so the new logical unit is absent in Disk Management. It does not explain the actual incident's evidence. The present cause is: Striping without redundancy provides no fault tolerance.

C:

This alternative cause would explain a different case: A storage team replaces a 10K RPM SAS drive with a consumer SATA model in a tightly specified redundant server array. It does not explain the actual incident's evidence. The present cause is: Striping without redundancy provides no fault tolerance.

D:

This alternative cause would explain a different case: A six-disk RAID 5 array is selected for a workload that must survive two simultaneous disk failures during a rebuild. It does not explain the actual incident's evidence. The present cause is: Striping without redundancy provides no fault tolerance.

Question 80

A server operations team encounters the following situation: A critical database stores its write-ahead log and transaction data in RAID 0 for speed despite requiring continued service after one drive failure. Which sustained operational control best reduces the likelihood of this same issue recurring?

  1. Test file-level restore from backups even on fully redundant arrays.
  2. Verify external-storage interfaces against replacement server ports.
  3. Reject nonredundant disk pools for workloads with hardware-failure availability requirements.
  4. Label storage-fabric ports and verify HBA interface type.

Explanation

Correct Answer

C:

This control targets the underlying recurrence risk: Striping without redundancy provides no fault tolerance. It builds validation into the affected workflow and supports the expected recovery result: The service remains available after a simulated single-disk failure.

Incorrect Answers

A:

This control addresses a different scenario: A RAID 1 pair is mistaken for a backup after an administrator deletes an important directory on the active volume. That event's root mechanism was mirroring propagates logical deletions; it is not historical recovery. The described incident instead arises from: Striping without redundancy provides no fault tolerance.

B:

This control addresses a different scenario: A legacy eSATA disk enclosure loses connectivity because the new server exposes only USB and SAS connectors. That event's root mechanism was connectors and protocols for external storage are not universally interchangeable. The described incident instead arises from: Striping without redundancy provides no fault tolerance.

D:

This control addresses a different scenario: A Fibre Channel host bus adapter is inserted into an Ethernet switch because both ports appear to use small optical connectors. That event's root mechanism was fibre Channel framing and Ethernet switching are not interchangeable physical services. The described incident instead arises from: Striping without redundancy provides no fault tolerance.