McAfee-Secured Website

Exam Bundle

Exam Code: SK0-005

Exam Name CompTIA Server+ Certification Exam

Certification Provider: CompTIA

Corresponding Certification: CompTIA Server+

CompTIA SK0-005 Bundle $44.99

100% CompTIA SK0-005 Guaranteed Success With Testking Training Materials

Get Real SK0-005 Exam Questions & Expert Verified Answers as Experienced on the Real Exam!

  • Questions & Answers

    SK0-005 Questions & Answers

    617 Questions & Answers

    The ultimate exam preparation tool, Questions & Answers mirrors the actual SK0-005 exam while allowing you to hone and measure every aspect of your test-taking ability.

  • SK0-005 Video Course

    SK0-005 Video Course

    139 Video Lectures

    SK0-005 Video Course is developed by CompTIA Professionals to help you pass the SK0-005 exam.

    Description

    This course will improve your knowledge and skills required to pass CompTIA Server+ Certification Exam exam.
  • Study Guide

    SK0-005 Study Guide

    533 PDF Pages

    Developed by industry experts, this 533-page guide spells out in painstaking detail all of the information you need to ace SK0-005 exam.

CompTIA Server+ Certification Exam (SK0-005) Practice Tests

Satisfaction Guaranteed

Money Back Guarantee

Testking provides hassle-free money back guarantee with our products. That is because we have 100% trust in the abilities of our professional and experience product team, and our record is a proof of that.

99.6% PASS RATE
Total Cost: $194.97
Bundle Price: $149.98

Purchase Individually

  • Questions & Answers

    Questions & Answers

    617 Questions

    $124.99
  • SK0-005 Video Course

    Video Course

    139 Video Lectures

    $39.99
  • Study Guide

    Study Guide

    533 PDF Pages

    $29.99

CompTIA SK0-005 Practice Test 6

Question 50

A server operations team encounters the following situation: Technicians use a consumer patch cable for a 10GbE run longer than its specified distance and see frequent cyclic redundancy errors. After making the corrective change, which result best demonstrates that this particular problem is resolved?

  1. POST and hardware inventory recognize the approved GPU after installation.
  2. Cable certification and port error counters meet the link acceptance criteria.
  3. All four network paths enumerate and carry approved traffic after installation.
  4. Equipment is secured without injury or damage during a supervised lift.

Explanation

Correct Answer

B:

This is incident-specific acceptance evidence: Cable certification and port error counters meet the link acceptance criteria. It verifies the action reinstall cabling certified for the negotiated speed and measured channel length. The failure under test was: The cabling channel does not meet electrical performance requirements at the selected rate.

Incorrect Answers

A:

This observation tests an unrelated Given a scenario, install physical hardware case: A rack-mount GPU server requires a PCIe slot layout unsupported by the selected motherboard revision, although its CPU count is adequate. It may be true while the current failure persists; the decisive current cause is: The cabling channel does not meet electrical performance requirements at the selected rate.

C:

This observation tests an unrelated Given a scenario, install physical hardware case: An expansion server needs four network ports, but the small-form chassis lacks enough PCIe slots for the specified add-in NICs. It may be true while the current failure persists; the decisive current cause is: The cabling channel does not meet electrical performance requirements at the selected rate.

D:

This observation tests an unrelated Given a scenario, install physical hardware case: An installation team plans to lift a populated 3U server alone into the top rails in violation of site safe-lift guidance. It may be true while the current failure persists; the decisive current cause is: The cabling channel does not meet electrical performance requirements at the selected rate.

Question 51

A server operations team encounters the following situation: Technicians use a consumer patch cable for a 10GbE run longer than its specified distance and see frequent cyclic redundancy errors. Which underlying cause most specifically explains the observed symptoms?

  1. Shared chassis infrastructure creates failure domains beyond individual blades.
  2. An incompatible mounting rail cannot provide a verified secure server installation.
  3. The cabling channel does not meet electrical performance requirements at the selected rate.
  4. Mismatched transceiver and fiber specifications prevent a valid optical link.

Explanation

Correct Answer

C:

This root-cause explanation directly accounts for the reported condition: Technicians use a consumer patch cable for a 10GbE run longer than its specified distance and see frequent cyclic redundancy errors. The corrective step is: Reinstall cabling certified for the negotiated speed and measured channel length. The verifying outcome is: Cable certification and port error counters meet the link acceptance criteria.

Incorrect Answers

A:

This alternative cause would explain a different case: A new blade chassis is connected to the network before its enclosure-level shared power and cooling redundancy has been configured. It does not explain the actual incident's evidence. The present cause is: The cabling channel does not meet electrical performance requirements at the selected rate.

B:

This alternative cause would explain a different case: A new 2U compute node ships with universal sliding rails that do not match the data center's square-hole posts. It does not explain the actual incident's evidence. The present cause is: The cabling channel does not meet electrical performance requirements at the selected rate.

D:

This alternative cause would explain a different case: Technicians install an active 10GbE optical link using a multimode transceiver at one end and a single-mode optic at the other. It does not explain the actual incident's evidence. The present cause is: The cabling channel does not meet electrical performance requirements at the selected rate.

Question 52

A server operations team encounters the following situation: Technicians use a consumer patch cable for a 10GbE run longer than its specified distance and see frequent cyclic redundancy errors. Which sustained operational control best reduces the likelihood of this same issue recurring?

  1. Recalculate runtime whenever rack equipment and load change.
  2. Verify wavelength, media type and connector specifications for each fiber run.
  3. Document enclosure-level fault tests as part of blade installation.
  4. Require tested cable category and length documentation for high-speed ports.

Explanation

Correct Answer

D:

This control targets the underlying recurrence risk: The cabling channel does not meet electrical performance requirements at the selected rate. It builds validation into the affected workflow and supports the expected recovery result: Cable certification and port error counters meet the link acceptance criteria.

Incorrect Answers

A:

This control addresses a different scenario: One site's new rack consumes more power than two UPS battery strings can support for the required graceful shutdown window. That event's root mechanism was battery runtime depends on actual load, not just the UPS nameplate apparent power. The described incident instead arises from: The cabling channel does not meet electrical performance requirements at the selected rate.

B:

This control addresses a different scenario: Technicians install an active 10GbE optical link using a multimode transceiver at one end and a single-mode optic at the other. That event's root mechanism was mismatched transceiver and fiber specifications prevent a valid optical link. The described incident instead arises from: The cabling channel does not meet electrical performance requirements at the selected rate.

C:

This control addresses a different scenario: A new blade chassis is connected to the network before its enclosure-level shared power and cooling redundancy has been configured. That event's root mechanism was shared chassis infrastructure creates failure domains beyond individual blades. The described incident instead arises from: The cabling channel does not meet electrical performance requirements at the selected rate.

Question 53

A server operations team encounters the following situation: One site's new rack consumes more power than two UPS battery strings can support for the required graceful shutdown window. Given the stated symptoms and constraints, which corrective action is the best next step?

  1. Recalculate power budget and provision sufficient rated redundant distribution before activation.
  2. Recalculate runtime at the proposed load and expand supported UPS capacity or reduce demand.
  3. Restore front-to-back air separation with blanking panels and appropriate rack airflow.
  4. Reinstall cabling certified for the negotiated speed and measured channel length.

Explanation

Correct Answer

B:

The preferred corrective action directly addresses the incident: One site's new rack consumes more power than two UPS battery strings can support for the required graceful shutdown window. The fault mechanism is battery runtime depends on actual load, not just the UPS nameplate apparent power. Expected confirmation is: A load test demonstrates the declared time to orderly shutdown.

Incorrect Answers

A:

This action is better suited to a separate Given a scenario, install physical hardware incident: An analytics rack's connected servers draw 6.8 kW, while the only installed PDU is rated for 5 kW continuous load. That case involves: The rack demand exceeds its available safe power capacity. Here the observed mechanism is instead: Battery runtime depends on actual load, not just the UPS nameplate apparent power. Applying the other repair would not directly resolve this fault.

C:

This action is better suited to a separate Given a scenario, install physical hardware incident: A 42U rack is filled with servers without any blanking panels, and inlet temperatures rise despite adequate room cooling. That case involves: Recirculation through unfilled gaps undermines the hot-aisle and cold-aisle arrangement. Here the observed mechanism is instead: Battery runtime depends on actual load, not just the UPS nameplate apparent power. Applying the other repair would not directly resolve this fault.

D:

This action is better suited to a separate Given a scenario, install physical hardware incident: Technicians use a consumer patch cable for a 10GbE run longer than its specified distance and see frequent cyclic redundancy errors. That case involves: The cabling channel does not meet electrical performance requirements at the selected rate. Here the observed mechanism is instead: Battery runtime depends on actual load, not just the UPS nameplate apparent power. Applying the other repair would not directly resolve this fault.

Question 54

A server operations team encounters the following situation: One site's new rack consumes more power than two UPS battery strings can support for the required graceful shutdown window. After making the corrective change, which result best demonstrates that this particular problem is resolved?

  1. Cable certification and port error counters meet the link acceptance criteria.
  2. All four network paths enumerate and carry approved traffic after installation.
  3. A load test demonstrates the declared time to orderly shutdown.
  4. The revised rack passes load and tip-risk inspection before energizing.

Explanation

Correct Answer

C:

This is incident-specific acceptance evidence: A load test demonstrates the declared time to orderly shutdown. It verifies the action recalculate runtime at the proposed load and expand supported UPS capacity or reduce demand. The failure under test was: Battery runtime depends on actual load, not just the UPS nameplate apparent power.

Incorrect Answers

A:

This observation tests an unrelated Given a scenario, install physical hardware case: Technicians use a consumer patch cable for a 10GbE run longer than its specified distance and see frequent cyclic redundancy errors. It may be true while the current failure persists; the decisive current cause is: Battery runtime depends on actual load, not just the UPS nameplate apparent power.

B:

This observation tests an unrelated Given a scenario, install physical hardware case: An expansion server needs four network ports, but the small-form chassis lacks enough PCIe slots for the specified add-in NICs. It may be true while the current failure persists; the decisive current cause is: Battery runtime depends on actual load, not just the UPS nameplate apparent power.

D:

This observation tests an unrelated Given a scenario, install physical hardware case: A heavy UPS is planned above lightly loaded servers in a rack that maintenance technicians frequently roll across a raised floor. It may be true while the current failure persists; the decisive current cause is: Battery runtime depends on actual load, not just the UPS nameplate apparent power.

Question 55

A server operations team encounters the following situation: One site's new rack consumes more power than two UPS battery strings can support for the required graceful shutdown window. Which underlying cause most specifically explains the observed symptoms?

  1. The installation prevents warm exhaust from leaving the cabinet.
  2. Unsupported manual handling presents a preventable installation safety risk.
  3. Shared chassis infrastructure creates failure domains beyond individual blades.
  4. Battery runtime depends on actual load, not just the UPS nameplate apparent power.

Explanation

Correct Answer

D:

This root-cause explanation directly accounts for the reported condition: One site's new rack consumes more power than two UPS battery strings can support for the required graceful shutdown window. The corrective step is: Recalculate runtime at the proposed load and expand supported UPS capacity or reduce demand. The verifying outcome is: A load test demonstrates the declared time to orderly shutdown.

Incorrect Answers

A:

This alternative cause would explain a different case: A compact server cabinet is placed against a wall that blocks its rear exhaust, and upper nodes throttle during batch workloads. It does not explain the actual incident's evidence. The present cause is: Battery runtime depends on actual load, not just the UPS nameplate apparent power.

B:

This alternative cause would explain a different case: An installation team plans to lift a populated 3U server alone into the top rails in violation of site safe-lift guidance. It does not explain the actual incident's evidence. The present cause is: Battery runtime depends on actual load, not just the UPS nameplate apparent power.

C:

This alternative cause would explain a different case: A new blade chassis is connected to the network before its enclosure-level shared power and cooling redundancy has been configured. It does not explain the actual incident's evidence. The present cause is: Battery runtime depends on actual load, not just the UPS nameplate apparent power.

Question 56

A server operations team encounters the following situation: One site's new rack consumes more power than two UPS battery strings can support for the required graceful shutdown window. Which sustained operational control best reduces the likelihood of this same issue recurring?

  1. Recalculate runtime whenever rack equipment and load change.
  2. Document enclosure-level fault tests as part of blade installation.
  3. Cross-check HCL expansion-slot and port counts before purchase.
  4. Check front and rear clearance against manufacturer installation guidance.

Explanation

Correct Answer

A:

This control targets the underlying recurrence risk: Battery runtime depends on actual load, not just the UPS nameplate apparent power. It builds validation into the affected workflow and supports the expected recovery result: A load test demonstrates the declared time to orderly shutdown.

Incorrect Answers

B:

This control addresses a different scenario: A new blade chassis is connected to the network before its enclosure-level shared power and cooling redundancy has been configured. That event's root mechanism was shared chassis infrastructure creates failure domains beyond individual blades. The described incident instead arises from: Battery runtime depends on actual load, not just the UPS nameplate apparent power.

C:

This control addresses a different scenario: An expansion server needs four network ports, but the small-form chassis lacks enough PCIe slots for the specified add-in NICs. That event's root mechanism was the proposed physical expansion count exceeds chassis slot capacity. The described incident instead arises from: Battery runtime depends on actual load, not just the UPS nameplate apparent power.

D:

This control addresses a different scenario: A compact server cabinet is placed against a wall that blocks its rear exhaust, and upper nodes throttle during batch workloads. That event's root mechanism was the installation prevents warm exhaust from leaving the cabinet. The described incident instead arises from: Battery runtime depends on actual load, not just the UPS nameplate apparent power.

Question 57

A server operations team encounters the following situation: An installation team plans to lift a populated 3U server alone into the top rails in violation of site safe-lift guidance. Given the stated symptoms and constraints, which corrective action is the best next step?

  1. Replace the incompatible optical module or cable with a matched supported pair.
  2. Recalculate runtime at the proposed load and expand supported UPS capacity or reduce demand.
  3. Use suitable lifting equipment and approved two-person handling before mounting.
  4. Reinstall cabling certified for the negotiated speed and measured channel length.

Explanation

Correct Answer

C:

The preferred corrective action directly addresses the incident: An installation team plans to lift a populated 3U server alone into the top rails in violation of site safe-lift guidance. The fault mechanism is unsupported manual handling presents a preventable installation safety risk. Expected confirmation is: Equipment is secured without injury or damage during a supervised lift.

Incorrect Answers

A:

This action is better suited to a separate Given a scenario, install physical hardware incident: Technicians install an active 10GbE optical link using a multimode transceiver at one end and a single-mode optic at the other. That case involves: Mismatched transceiver and fiber specifications prevent a valid optical link. Here the observed mechanism is instead: Unsupported manual handling presents a preventable installation safety risk. Applying the other repair would not directly resolve this fault.

B:

This action is better suited to a separate Given a scenario, install physical hardware incident: One site's new rack consumes more power than two UPS battery strings can support for the required graceful shutdown window. That case involves: Battery runtime depends on actual load, not just the UPS nameplate apparent power. Here the observed mechanism is instead: Unsupported manual handling presents a preventable installation safety risk. Applying the other repair would not directly resolve this fault.

D:

This action is better suited to a separate Given a scenario, install physical hardware incident: Technicians use a consumer patch cable for a 10GbE run longer than its specified distance and see frequent cyclic redundancy errors. That case involves: The cabling channel does not meet electrical performance requirements at the selected rate. Here the observed mechanism is instead: Unsupported manual handling presents a preventable installation safety risk. Applying the other repair would not directly resolve this fault.

Question 58

A server operations team encounters the following situation: An installation team plans to lift a populated 3U server alone into the top rails in violation of site safe-lift guidance. After making the corrective change, which result best demonstrates that this particular problem is resolved?

  1. A controlled fan or power-module failure preserves supported blade operation.
  2. The link negotiates reliably and shows acceptable optical diagnostics and error counters.
  3. All four network paths enumerate and carry approved traffic after installation.
  4. Equipment is secured without injury or damage during a supervised lift.

Explanation

Correct Answer

D:

This is incident-specific acceptance evidence: Equipment is secured without injury or damage during a supervised lift. It verifies the action use suitable lifting equipment and approved two-person handling before mounting. The failure under test was: Unsupported manual handling presents a preventable installation safety risk.

Incorrect Answers

A:

This observation tests an unrelated Given a scenario, install physical hardware case: A new blade chassis is connected to the network before its enclosure-level shared power and cooling redundancy has been configured. It may be true while the current failure persists; the decisive current cause is: Unsupported manual handling presents a preventable installation safety risk.

B:

This observation tests an unrelated Given a scenario, install physical hardware case: Technicians install an active 10GbE optical link using a multimode transceiver at one end and a single-mode optic at the other. It may be true while the current failure persists; the decisive current cause is: Unsupported manual handling presents a preventable installation safety risk.

C:

This observation tests an unrelated Given a scenario, install physical hardware case: An expansion server needs four network ports, but the small-form chassis lacks enough PCIe slots for the specified add-in NICs. It may be true while the current failure persists; the decisive current cause is: Unsupported manual handling presents a preventable installation safety risk.

Question 59

A server operations team encounters the following situation: An installation team plans to lift a populated 3U server alone into the top rails in violation of site safe-lift guidance. Which underlying cause most specifically explains the observed symptoms?

  1. Unsupported manual handling presents a preventable installation safety risk.
  2. Recirculation through unfilled gaps undermines the hot-aisle and cold-aisle arrangement.
  3. Available total units do not imply an enclosure can occupy fragmented rack space.
  4. Physical connector compatibility is required in addition to optical signal compatibility.

Explanation

Correct Answer

A:

This root-cause explanation directly accounts for the reported condition: An installation team plans to lift a populated 3U server alone into the top rails in violation of site safe-lift guidance. The corrective step is: Use suitable lifting equipment and approved two-person handling before mounting. The verifying outcome is: Equipment is secured without injury or damage during a supervised lift.

Incorrect Answers

B:

This alternative cause would explain a different case: A 42U rack is filled with servers without any blanking panels, and inlet temperatures rise despite adequate room cooling. It does not explain the actual incident's evidence. The present cause is: Unsupported manual handling presents a preventable installation safety risk.

C:

This alternative cause would explain a different case: A hospital orders 4U blade enclosures but the existing 24U rack has only 2U contiguous free space near its reserved airflow corridor. It does not explain the actual incident's evidence. The present cause is: Unsupported manual handling presents a preventable installation safety risk.

D:

This alternative cause would explain a different case: A mixed-fiber patch panel uses LC duplex ports but the ordered switch transceivers expect an unrelated connector type. It does not explain the actual incident's evidence. The present cause is: Unsupported manual handling presents a preventable installation safety risk.

Question 60

A server operations team encounters the following situation: An installation team plans to lift a populated 3U server alone into the top rails in violation of site safe-lift guidance. Which sustained operational control best reduces the likelihood of this same issue recurring?

  1. Keep optical part numbers tied to port speed requirements.
  2. Train teams and stage lifting resources for heavy chassis deliveries.
  3. Require rack weight distribution and site structural review for each major installation.
  4. Verify wavelength, media type and connector specifications for each fiber run.

Explanation

Correct Answer

B:

This control targets the underlying recurrence risk: Unsupported manual handling presents a preventable installation safety risk. It builds validation into the affected workflow and supports the expected recovery result: Equipment is secured without injury or damage during a supervised lift.

Incorrect Answers

A:

This control addresses a different scenario: A new 10GbE NIC is fitted with a 1GbE-only SFP module, and a storage transfer cannot reach its specified link rate. That event's root mechanism was the installed pluggable is not capable of the intended link speed. The described incident instead arises from: Unsupported manual handling presents a preventable installation safety risk.

C:

This control addresses a different scenario: A heavy UPS is planned above lightly loaded servers in a rack that maintenance technicians frequently roll across a raised floor. That event's root mechanism was high center of gravity and unverified floor loading create a personnel and stability hazard. The described incident instead arises from: Unsupported manual handling presents a preventable installation safety risk.

D:

This control addresses a different scenario: Technicians install an active 10GbE optical link using a multimode transceiver at one end and a single-mode optic at the other. That event's root mechanism was mismatched transceiver and fiber specifications prevent a valid optical link. The described incident instead arises from: Unsupported manual handling presents a preventable installation safety risk.