McAfee-Secured Website

Exam Bundle

Exam Code: SK0-005

Exam Name CompTIA Server+ Certification Exam

Certification Provider: CompTIA

Corresponding Certification: CompTIA Server+

CompTIA SK0-005 Bundle $44.99

100% CompTIA SK0-005 Guaranteed Success With Testking Training Materials

Get Real SK0-005 Exam Questions & Expert Verified Answers as Experienced on the Real Exam!

  • Questions & Answers

    SK0-005 Questions & Answers

    617 Questions & Answers

    The ultimate exam preparation tool, Questions & Answers mirrors the actual SK0-005 exam while allowing you to hone and measure every aspect of your test-taking ability.

  • SK0-005 Video Course

    SK0-005 Video Course

    139 Video Lectures

    SK0-005 Video Course is developed by CompTIA Professionals to help you pass the SK0-005 exam.

    Description

    This course will improve your knowledge and skills required to pass CompTIA Server+ Certification Exam exam.
  • Study Guide

    SK0-005 Study Guide

    533 PDF Pages

    Developed by industry experts, this 533-page guide spells out in painstaking detail all of the information you need to ace SK0-005 exam.

CompTIA Server+ Certification Exam (SK0-005) Practice Tests

Satisfaction Guaranteed

Money Back Guarantee

Testking provides hassle-free money back guarantee with our products. That is because we have 100% trust in the abilities of our professional and experience product team, and our record is a proof of that.

99.6% PASS RATE
Total Cost: $194.97
Bundle Price: $149.98

Purchase Individually

  • Questions & Answers

    Questions & Answers

    617 Questions

    $124.99
  • SK0-005 Video Course

    Video Course

    139 Video Lectures

    $39.99
  • Study Guide

    Study Guide

    533 PDF Pages

    $29.99

CompTIA SK0-005 Practice Test 9

Question 80

A server operations team encounters the following situation: A critical database stores its write-ahead log and transaction data in RAID 0 for speed despite requiring continued service after one drive failure. Which sustained operational control best reduces the likelihood of this same issue recurring?

  1. Test file-level restore from backups even on fully redundant arrays.
  2. Verify external-storage interfaces against replacement server ports.
  3. Reject nonredundant disk pools for workloads with hardware-failure availability requirements.
  4. Label storage-fabric ports and verify HBA interface type.

Explanation

Correct Answer

C:

This control targets the underlying recurrence risk: Striping without redundancy provides no fault tolerance. It builds validation into the affected workflow and supports the expected recovery result: The service remains available after a simulated single-disk failure.

Incorrect Answers

A:

This control addresses a different scenario: A RAID 1 pair is mistaken for a backup after an administrator deletes an important directory on the active volume. That event's root mechanism was mirroring propagates logical deletions; it is not historical recovery. The described incident instead arises from: Striping without redundancy provides no fault tolerance.

B:

This control addresses a different scenario: A legacy eSATA disk enclosure loses connectivity because the new server exposes only USB and SAS connectors. That event's root mechanism was connectors and protocols for external storage are not universally interchangeable. The described incident instead arises from: Striping without redundancy provides no fault tolerance.

D:

This control addresses a different scenario: A Fibre Channel host bus adapter is inserted into an Ethernet switch because both ports appear to use small optical connectors. That event's root mechanism was fibre Channel framing and Ethernet switching are not interchangeable physical services. The described incident instead arises from: Striping without redundancy provides no fault tolerance.

Question 81

A server operations team encounters the following situation: A media server needs mirrored data with high random-write performance, but its chosen RAID 5 group experiences large write penalties. Given the stated symptoms and constraints, which corrective action is the best next step?

  1. Evaluate RAID 10 with adequate disk count and measured application IOPS.
  2. Check array expansion rules and account for smallest-member or virtual-disk constraints.
  3. Select compliant backup media and off-site retention with integrity validation.
  4. Use an approved supported interface or adapter path rather than forcing the cable.

Explanation

Correct Answer

A:

The preferred corrective action directly addresses the incident: A media server needs mirrored data with high random-write performance, but its chosen RAID 5 group experiences large write penalties. The fault mechanism is parity write operations impose overhead for the transaction pattern. Expected confirmation is: A representative write workload meets latency targets and survives supported drive failures.

Incorrect Answers

B:

This action is better suited to a separate Given a scenario, deploy and manage storage incident: A team expands an existing RAID 6 pool with dissimilar disks and assumes the full largest disk size contributes from each member. That case involves: Mixed sizes can waste capacity or violate controller layout assumptions. Here the observed mechanism is instead: Parity write operations impose overhead for the transaction pattern. Applying the other repair would not directly resolve this fault.

C:

This action is better suited to a separate Given a scenario, deploy and manage storage incident: A backup server uses a single consumer USB SSD as its only long-term archive, although policy requires durable off-site retention. That case involves: One portable disk is a fragile single-copy retention strategy. Here the observed mechanism is instead: Parity write operations impose overhead for the transaction pattern. Applying the other repair would not directly resolve this fault.

D:

This action is better suited to a separate Given a scenario, deploy and manage storage incident: A legacy eSATA disk enclosure loses connectivity because the new server exposes only USB and SAS connectors. That case involves: Connectors and protocols for external storage are not universally interchangeable. Here the observed mechanism is instead: Parity write operations impose overhead for the transaction pattern. Applying the other repair would not directly resolve this fault.

Question 82

A server operations team encounters the following situation: A media server needs mirrored data with high random-write performance, but its chosen RAID 5 group experiences large write penalties. After making the corrective change, which result best demonstrates that this particular problem is resolved?

  1. The capacity calculation matches controller-reported usable space.
  2. A representative write workload meets latency targets and survives supported drive failures.
  3. Post-expansion usable capacity matches the controller model and remains protected.
  4. A VM migrates between hosts while retaining access to its disks.

Explanation

Correct Answer

B:

This is incident-specific acceptance evidence: A representative write workload meets latency targets and survives supported drive failures. It verifies the action evaluate RAID 10 with adequate disk count and measured application IOPS. The failure under test was: Parity write operations impose overhead for the transaction pattern.

Incorrect Answers

A:

This observation tests an unrelated Given a scenario, deploy and manage storage case: An administrator assumes four 8 TB disks configured as RAID 6 will provide 32 TB of usable storage. It may be true while the current failure persists; the decisive current cause is: Parity write operations impose overhead for the transaction pattern.

C:

This observation tests an unrelated Given a scenario, deploy and manage storage case: A team expands an existing RAID 6 pool with dissimilar disks and assumes the full largest disk size contributes from each member. It may be true while the current failure persists; the decisive current cause is: Parity write operations impose overhead for the transaction pattern.

D:

This observation tests an unrelated Given a scenario, deploy and manage storage case: A virtualization cluster expects live migration through shared storage, yet its design uses only server-local SATA disks. It may be true while the current failure persists; the decisive current cause is: Parity write operations impose overhead for the transaction pattern.

Question 83

A server operations team encounters the following situation: A media server needs mirrored data with high random-write performance, but its chosen RAID 5 group experiences large write penalties. Which underlying cause most specifically explains the observed symptoms?

  1. Mirroring propagates logical deletions; it is not historical recovery.
  2. Ordinary filesystem drivers cannot safely coordinate unsupervised simultaneous raw block writers.
  3. Parity write operations impose overhead for the transaction pattern.
  4. One portable disk is a fragile single-copy retention strategy.

Explanation

Correct Answer

C:

This root-cause explanation directly accounts for the reported condition: A media server needs mirrored data with high random-write performance, but its chosen RAID 5 group experiences large write penalties. The corrective step is: Evaluate RAID 10 with adequate disk count and measured application IOPS. The verifying outcome is: A representative write workload meets latency targets and survives supported drive failures.

Incorrect Answers

A:

This alternative cause would explain a different case: A RAID 1 pair is mistaken for a backup after an administrator deletes an important directory on the active volume. It does not explain the actual incident's evidence. The present cause is: Parity write operations impose overhead for the transaction pattern.

B:

This alternative cause would explain a different case: A SAN volume is assigned to two standalone Windows servers without cluster-aware filesystem controls, and its filesystem becomes corrupt. It does not explain the actual incident's evidence. The present cause is: Parity write operations impose overhead for the transaction pattern.

D:

This alternative cause would explain a different case: A backup server uses a single consumer USB SSD as its only long-term archive, although policy requires durable off-site retention. It does not explain the actual incident's evidence. The present cause is: Parity write operations impose overhead for the transaction pattern.

Question 84

A server operations team encounters the following situation: A media server needs mirrored data with high random-write performance, but its chosen RAID 5 group experiences large write penalties. Which sustained operational control best reduces the likelihood of this same issue recurring?

  1. Check target ACLs and initiator login during storage provisioning.
  2. Document tolerated failures and rebuild exposure in storage design decisions.
  3. Record write amplification and workload profiles for flash tier refreshes.
  4. Benchmark application write mix before selecting RAID level.

Explanation

Correct Answer

D:

This control targets the underlying recurrence risk: Parity write operations impose overhead for the transaction pattern. It builds validation into the affected workflow and supports the expected recovery result: A representative write workload meets latency targets and survives supported drive failures.

Incorrect Answers

A:

This control addresses a different scenario: A server is given an iSCSI target IP but never logs in to the target, so the new logical unit is absent in Disk Management. That event's root mechanism was target address entry alone does not establish an iSCSI session or LUN assignment. The described incident instead arises from: Parity write operations impose overhead for the transaction pattern.

B:

This control addresses a different scenario: A six-disk RAID 5 array is selected for a workload that must survive two simultaneous disk failures during a rebuild. That event's root mechanism was single-parity RAID 5 does not protect against two concurrent disk failures. The described incident instead arises from: Parity write operations impose overhead for the transaction pattern.

C:

This control addresses a different scenario: A high-density read cache uses write-intensive SSDs with excessive cost while backend workloads are predominantly sequential reads. That event's root mechanism was drive endurance classes should match actual read-write patterns rather than blanket maximum ratings. The described incident instead arises from: Parity write operations impose overhead for the transaction pattern.

Question 85

A server operations team encounters the following situation: An administrator assumes four 8 TB disks configured as RAID 6 will provide 32 TB of usable storage. Given the stated symptoms and constraints, which corrective action is the best next step?

  1. Use an approved supported interface or adapter path rather than forcing the cable.
  2. Plan usable capacity after two drives' worth of parity and applicable filesystem overhead.
  3. Check controller and array drive compatibility before selecting a supported replacement.
  4. Deploy compatible shared block or file storage according to the hypervisor's live-migration requirements.

Explanation

Correct Answer

B:

The preferred corrective action directly addresses the incident: An administrator assumes four 8 TB disks configured as RAID 6 will provide 32 TB of usable storage. The fault mechanism is dual-parity RAID consumes space equal to two member drive capacities. Expected confirmation is: The capacity calculation matches controller-reported usable space.

Incorrect Answers

A:

This action is better suited to a separate Given a scenario, deploy and manage storage incident: A legacy eSATA disk enclosure loses connectivity because the new server exposes only USB and SAS connectors. That case involves: Connectors and protocols for external storage are not universally interchangeable. Here the observed mechanism is instead: Dual-parity RAID consumes space equal to two member drive capacities. Applying the other repair would not directly resolve this fault.

C:

This action is better suited to a separate Given a scenario, deploy and manage storage incident: A storage team replaces a 10K RPM SAS drive with a consumer SATA model in a tightly specified redundant server array. That case involves: Drive capacity alone does not guarantee controller, interface or firmware compatibility. Here the observed mechanism is instead: Dual-parity RAID consumes space equal to two member drive capacities. Applying the other repair would not directly resolve this fault.

D:

This action is better suited to a separate Given a scenario, deploy and manage storage incident: A virtualization cluster expects live migration through shared storage, yet its design uses only server-local SATA disks. That case involves: Local disks are not automatically visible to other cluster nodes. Here the observed mechanism is instead: Dual-parity RAID consumes space equal to two member drive capacities. Applying the other repair would not directly resolve this fault.

Question 86

A server operations team encounters the following situation: An administrator assumes four 8 TB disks configured as RAID 6 will provide 32 TB of usable storage. After making the corrective change, which result best demonstrates that this particular problem is resolved?

  1. Provisioned datasets fit with an explicit reserve after full protection overhead.
  2. A controlled member failure does not destroy protected data in the revised design.
  3. The capacity calculation matches controller-reported usable space.
  4. Benchmarks satisfy read latency and wear limits at the planned cost.

Explanation

Correct Answer

C:

This is incident-specific acceptance evidence: The capacity calculation matches controller-reported usable space. It verifies the action plan usable capacity after two drives' worth of parity and applicable filesystem overhead. The failure under test was: Dual-parity RAID consumes space equal to two member drive capacities.

Incorrect Answers

A:

This observation tests an unrelated Given a scenario, deploy and manage storage case: A capacity planner chooses a raw 24 TB storage shelf for a 22 TB dataset without space for RAID overhead, snapshots or growth. It may be true while the current failure persists; the decisive current cause is: Dual-parity RAID consumes space equal to two member drive capacities.

B:

This observation tests an unrelated Given a scenario, deploy and manage storage case: A 12-disk JBOD enclosure is described as fault tolerant because it provides a single combined capacity pool. It may be true while the current failure persists; the decisive current cause is: Dual-parity RAID consumes space equal to two member drive capacities.

D:

This observation tests an unrelated Given a scenario, deploy and manage storage case: A high-density read cache uses write-intensive SSDs with excessive cost while backend workloads are predominantly sequential reads. It may be true while the current failure persists; the decisive current cause is: Dual-parity RAID consumes space equal to two member drive capacities.

Question 87

A server operations team encounters the following situation: An administrator assumes four 8 TB disks configured as RAID 6 will provide 32 TB of usable storage. Which underlying cause most specifically explains the observed symptoms?

  1. Parity write operations impose overhead for the transaction pattern.
  2. Connectors and protocols for external storage are not universally interchangeable.
  3. Mixed sizes can waste capacity or violate controller layout assumptions.
  4. Dual-parity RAID consumes space equal to two member drive capacities.

Explanation

Correct Answer

D:

This root-cause explanation directly accounts for the reported condition: An administrator assumes four 8 TB disks configured as RAID 6 will provide 32 TB of usable storage. The corrective step is: Plan usable capacity after two drives' worth of parity and applicable filesystem overhead. The verifying outcome is: The capacity calculation matches controller-reported usable space.

Incorrect Answers

A:

This alternative cause would explain a different case: A media server needs mirrored data with high random-write performance, but its chosen RAID 5 group experiences large write penalties. It does not explain the actual incident's evidence. The present cause is: Dual-parity RAID consumes space equal to two member drive capacities.

B:

This alternative cause would explain a different case: A legacy eSATA disk enclosure loses connectivity because the new server exposes only USB and SAS connectors. It does not explain the actual incident's evidence. The present cause is: Dual-parity RAID consumes space equal to two member drive capacities.

C:

This alternative cause would explain a different case: A team expands an existing RAID 6 pool with dissimilar disks and assumes the full largest disk size contributes from each member. It does not explain the actual incident's evidence. The present cause is: Dual-parity RAID consumes space equal to two member drive capacities.

Question 88

A server operations team encounters the following situation: An administrator assumes four 8 TB disks configured as RAID 6 will provide 32 TB of usable storage. Which sustained operational control best reduces the likelihood of this same issue recurring?

  1. Use conservative RAID capacity planning before procurement.
  2. Require tested capacity calculations for heterogeneous RAID expansions.
  3. Verify shared datastore accessibility from every host before enabling mobility.
  4. Review shared-disk ownership and fencing before multi-host presentation.

Explanation

Correct Answer

A:

This control targets the underlying recurrence risk: Dual-parity RAID consumes space equal to two member drive capacities. It builds validation into the affected workflow and supports the expected recovery result: The capacity calculation matches controller-reported usable space.

Incorrect Answers

B:

This control addresses a different scenario: A team expands an existing RAID 6 pool with dissimilar disks and assumes the full largest disk size contributes from each member. That event's root mechanism was mixed sizes can waste capacity or violate controller layout assumptions. The described incident instead arises from: Dual-parity RAID consumes space equal to two member drive capacities.

C:

This control addresses a different scenario: A virtualization cluster expects live migration through shared storage, yet its design uses only server-local SATA disks. That event's root mechanism was local disks are not automatically visible to other cluster nodes. The described incident instead arises from: Dual-parity RAID consumes space equal to two member drive capacities.

D:

This control addresses a different scenario: A SAN volume is assigned to two standalone Windows servers without cluster-aware filesystem controls, and its filesystem becomes corrupt. That event's root mechanism was ordinary filesystem drivers cannot safely coordinate unsupervised simultaneous raw block writers. The described incident instead arises from: Dual-parity RAID consumes space equal to two member drive capacities.

Question 89

A server operations team encounters the following situation: A replacement SSD with lower endurance rating is installed in a high-write logging host, and wear indicators rapidly approach limits. Given the stated symptoms and constraints, which corrective action is the best next step?

  1. Use an approved supported interface or adapter path rather than forcing the cable.
  2. Repair or replace the supported cache protection component before enabling protected write-back caching.
  3. Select a write-intensive SSD with supported endurance and capacity for measured daily writes.
  4. Migrate to a redundant RAID layout appropriate for database I/O and resilience.

Explanation

Correct Answer

C:

The preferred corrective action directly addresses the incident: A replacement SSD with lower endurance rating is installed in a high-write logging host, and wear indicators rapidly approach limits. The fault mechanism is read-oriented flash endurance is unsuitable for the sustained write workload. Expected confirmation is: Wear telemetry stays within the expected service-life projection.

Incorrect Answers

A:

This action is better suited to a separate Given a scenario, deploy and manage storage incident: A legacy eSATA disk enclosure loses connectivity because the new server exposes only USB and SAS connectors. That case involves: Connectors and protocols for external storage are not universally interchangeable. Here the observed mechanism is instead: Read-oriented flash endurance is unsuitable for the sustained write workload. Applying the other repair would not directly resolve this fault.

B:

This action is better suited to a separate Given a scenario, deploy and manage storage incident: A RAID array reports write-back cache disabled after its battery protection module failed, and transaction throughput drops sharply. That case involves: Unprotected controller cache cannot safely preserve acknowledged writes across a power loss. Here the observed mechanism is instead: Read-oriented flash endurance is unsuitable for the sustained write workload. Applying the other repair would not directly resolve this fault.

D:

This action is better suited to a separate Given a scenario, deploy and manage storage incident: A critical database stores its write-ahead log and transaction data in RAID 0 for speed despite requiring continued service after one drive failure. That case involves: Striping without redundancy provides no fault tolerance. Here the observed mechanism is instead: Read-oriented flash endurance is unsuitable for the sustained write workload. Applying the other repair would not directly resolve this fault.

Question 90

A server operations team encounters the following situation: A replacement SSD with lower endurance rating is installed in a high-write logging host, and wear indicators rapidly approach limits. After making the corrective change, which result best demonstrates that this particular problem is resolved?

  1. The service remains available after a simulated single-disk failure.
  2. Benchmarks satisfy read latency and wear limits at the planned cost.
  3. The controller accepts the drive and the array rebuilds without interface errors.
  4. Wear telemetry stays within the expected service-life projection.

Explanation

Correct Answer

D:

This is incident-specific acceptance evidence: Wear telemetry stays within the expected service-life projection. It verifies the action select a write-intensive SSD with supported endurance and capacity for measured daily writes. The failure under test was: Read-oriented flash endurance is unsuitable for the sustained write workload.

Incorrect Answers

A:

This observation tests an unrelated Given a scenario, deploy and manage storage case: A critical database stores its write-ahead log and transaction data in RAID 0 for speed despite requiring continued service after one drive failure. It may be true while the current failure persists; the decisive current cause is: Read-oriented flash endurance is unsuitable for the sustained write workload.

B:

This observation tests an unrelated Given a scenario, deploy and manage storage case: A high-density read cache uses write-intensive SSDs with excessive cost while backend workloads are predominantly sequential reads. It may be true while the current failure persists; the decisive current cause is: Read-oriented flash endurance is unsuitable for the sustained write workload.

C:

This observation tests an unrelated Given a scenario, deploy and manage storage case: A storage team replaces a 10K RPM SAS drive with a consumer SATA model in a tightly specified redundant server array. It may be true while the current failure persists; the decisive current cause is: Read-oriented flash endurance is unsuitable for the sustained write workload.