McAfee-Secured Website

Exam Bundle

Exam Code: SK0-005

Exam Name CompTIA Server+ Certification Exam

Certification Provider: CompTIA

Corresponding Certification: CompTIA Server+

CompTIA SK0-005 Bundle $44.99

100% CompTIA SK0-005 Guaranteed Success With Testking Training Materials

Get Real SK0-005 Exam Questions & Expert Verified Answers as Experienced on the Real Exam!

  • Questions & Answers

    SK0-005 Questions & Answers

    617 Questions & Answers

    The ultimate exam preparation tool, Questions & Answers mirrors the actual SK0-005 exam while allowing you to hone and measure every aspect of your test-taking ability.

  • SK0-005 Video Course

    SK0-005 Video Course

    139 Video Lectures

    SK0-005 Video Course is developed by CompTIA Professionals to help you pass the SK0-005 exam.

    Description

    This course will improve your knowledge and skills required to pass CompTIA Server+ Certification Exam exam.
  • Study Guide

    SK0-005 Study Guide

    533 PDF Pages

    Developed by industry experts, this 533-page guide spells out in painstaking detail all of the information you need to ace SK0-005 exam.

CompTIA Server+ Certification Exam (SK0-005) Practice Tests

Satisfaction Guaranteed

Money Back Guarantee

Testking provides hassle-free money back guarantee with our products. That is because we have 100% trust in the abilities of our professional and experience product team, and our record is a proof of that.

99.6% PASS RATE
Total Cost: $194.97
Bundle Price: $149.98

Purchase Individually

  • Questions & Answers

    Questions & Answers

    617 Questions

    $124.99
  • SK0-005 Video Course

    Video Course

    139 Video Lectures

    $39.99
  • Study Guide

    Study Guide

    533 PDF Pages

    $29.99

CompTIA SK0-005 Practice Test 10

Question 90

A server operations team encounters the following situation: A replacement SSD with lower endurance rating is installed in a high-write logging host, and wear indicators rapidly approach limits. After making the corrective change, which result best demonstrates that this particular problem is resolved?

  1. The service remains available after a simulated single-disk failure.
  2. Benchmarks satisfy read latency and wear limits at the planned cost.
  3. The controller accepts the drive and the array rebuilds without interface errors.
  4. Wear telemetry stays within the expected service-life projection.

Explanation

Correct Answer

D:

This is incident-specific acceptance evidence: Wear telemetry stays within the expected service-life projection. It verifies the action select a write-intensive SSD with supported endurance and capacity for measured daily writes. The failure under test was: Read-oriented flash endurance is unsuitable for the sustained write workload.

Incorrect Answers

A:

This observation tests an unrelated Given a scenario, deploy and manage storage case: A critical database stores its write-ahead log and transaction data in RAID 0 for speed despite requiring continued service after one drive failure. It may be true while the current failure persists; the decisive current cause is: Read-oriented flash endurance is unsuitable for the sustained write workload.

B:

This observation tests an unrelated Given a scenario, deploy and manage storage case: A high-density read cache uses write-intensive SSDs with excessive cost while backend workloads are predominantly sequential reads. It may be true while the current failure persists; the decisive current cause is: Read-oriented flash endurance is unsuitable for the sustained write workload.

C:

This observation tests an unrelated Given a scenario, deploy and manage storage case: A storage team replaces a 10K RPM SAS drive with a consumer SATA model in a tightly specified redundant server array. It may be true while the current failure persists; the decisive current cause is: Read-oriented flash endurance is unsuitable for the sustained write workload.

Question 91

A server operations team encounters the following situation: A replacement SSD with lower endurance rating is installed in a high-write logging host, and wear indicators rapidly approach limits. Which underlying cause most specifically explains the observed symptoms?

  1. Read-oriented flash endurance is unsuitable for the sustained write workload.
  2. Single-parity RAID 5 does not protect against two concurrent disk failures.
  3. One portable disk is a fragile single-copy retention strategy.
  4. JBOD by itself does not supply striping parity or mirroring.

Explanation

Correct Answer

A:

This root-cause explanation directly accounts for the reported condition: A replacement SSD with lower endurance rating is installed in a high-write logging host, and wear indicators rapidly approach limits. The corrective step is: Select a write-intensive SSD with supported endurance and capacity for measured daily writes. The verifying outcome is: Wear telemetry stays within the expected service-life projection.

Incorrect Answers

B:

This alternative cause would explain a different case: A six-disk RAID 5 array is selected for a workload that must survive two simultaneous disk failures during a rebuild. It does not explain the actual incident's evidence. The present cause is: Read-oriented flash endurance is unsuitable for the sustained write workload.

C:

This alternative cause would explain a different case: A backup server uses a single consumer USB SSD as its only long-term archive, although policy requires durable off-site retention. It does not explain the actual incident's evidence. The present cause is: Read-oriented flash endurance is unsuitable for the sustained write workload.

D:

This alternative cause would explain a different case: A 12-disk JBOD enclosure is described as fault tolerant because it provides a single combined capacity pool. It does not explain the actual incident's evidence. The present cause is: Read-oriented flash endurance is unsuitable for the sustained write workload.

Question 92

A server operations team encounters the following situation: A replacement SSD with lower endurance rating is installed in a high-write logging host, and wear indicators rapidly approach limits. Which sustained operational control best reduces the likelihood of this same issue recurring?

  1. Maintain qualified spare part numbers for each array model.
  2. Include total bytes written and endurance class in drive procurement.
  3. Reject nonredundant disk pools for workloads with hardware-failure availability requirements.
  4. Verify external-storage interfaces against replacement server ports.

Explanation

Correct Answer

B:

This control targets the underlying recurrence risk: Read-oriented flash endurance is unsuitable for the sustained write workload. It builds validation into the affected workflow and supports the expected recovery result: Wear telemetry stays within the expected service-life projection.

Incorrect Answers

A:

This control addresses a different scenario: A storage team replaces a 10K RPM SAS drive with a consumer SATA model in a tightly specified redundant server array. That event's root mechanism was drive capacity alone does not guarantee controller, interface or firmware compatibility. The described incident instead arises from: Read-oriented flash endurance is unsuitable for the sustained write workload.

C:

This control addresses a different scenario: A critical database stores its write-ahead log and transaction data in RAID 0 for speed despite requiring continued service after one drive failure. That event's root mechanism was striping without redundancy provides no fault tolerance. The described incident instead arises from: Read-oriented flash endurance is unsuitable for the sustained write workload.

D:

This control addresses a different scenario: A legacy eSATA disk enclosure loses connectivity because the new server exposes only USB and SAS connectors. That event's root mechanism was connectors and protocols for external storage are not universally interchangeable. The described incident instead arises from: Read-oriented flash endurance is unsuitable for the sustained write workload.

Question 93

A server operations team encounters the following situation: A virtualization cluster expects live migration through shared storage, yet its design uses only server-local SATA disks. Given the stated symptoms and constraints, which corrective action is the best next step?

  1. Calculate usable capacity with redundancy, snapshots and projected growth headroom.
  2. Right-size read-intensive flash to observed workload and endurance needs.
  3. Check array expansion rules and account for smallest-member or virtual-disk constraints.
  4. Deploy compatible shared block or file storage according to the hypervisor's live-migration requirements.

Explanation

Correct Answer

D:

The preferred corrective action directly addresses the incident: A virtualization cluster expects live migration through shared storage, yet its design uses only server-local SATA disks. The fault mechanism is local disks are not automatically visible to other cluster nodes. Expected confirmation is: A VM migrates between hosts while retaining access to its disks.

Incorrect Answers

A:

This action is better suited to a separate Given a scenario, deploy and manage storage incident: A capacity planner chooses a raw 24 TB storage shelf for a 22 TB dataset without space for RAID overhead, snapshots or growth. That case involves: Raw nameplate bytes overstate application-usable storage. Here the observed mechanism is instead: Local disks are not automatically visible to other cluster nodes. Applying the other repair would not directly resolve this fault.

B:

This action is better suited to a separate Given a scenario, deploy and manage storage incident: A high-density read cache uses write-intensive SSDs with excessive cost while backend workloads are predominantly sequential reads. That case involves: Drive endurance classes should match actual read-write patterns rather than blanket maximum ratings. Here the observed mechanism is instead: Local disks are not automatically visible to other cluster nodes. Applying the other repair would not directly resolve this fault.

C:

This action is better suited to a separate Given a scenario, deploy and manage storage incident: A team expands an existing RAID 6 pool with dissimilar disks and assumes the full largest disk size contributes from each member. That case involves: Mixed sizes can waste capacity or violate controller layout assumptions. Here the observed mechanism is instead: Local disks are not automatically visible to other cluster nodes. Applying the other repair would not directly resolve this fault.

Question 94

A server operations team encounters the following situation: A virtualization cluster expects live migration through shared storage, yet its design uses only server-local SATA disks. After making the corrective change, which result best demonstrates that this particular problem is resolved?

  1. A VM migrates between hosts while retaining access to its disks.
  2. Benchmarks satisfy read latency and wear limits at the planned cost.
  3. Clients access files through SMB while the server owns and manages the block filesystem.
  4. The controller accepts the drive and the array rebuilds without interface errors.

Explanation

Correct Answer

A:

This is incident-specific acceptance evidence: A VM migrates between hosts while retaining access to its disks. It verifies the action deploy compatible shared block or file storage according to the hypervisor's live-migration requirements. The failure under test was: Local disks are not automatically visible to other cluster nodes.

Incorrect Answers

B:

This observation tests an unrelated Given a scenario, deploy and manage storage case: A high-density read cache uses write-intensive SSDs with excessive cost while backend workloads are predominantly sequential reads. It may be true while the current failure persists; the decisive current cause is: Local disks are not automatically visible to other cluster nodes.

C:

This observation tests an unrelated Given a scenario, deploy and manage storage case: An administrator migrates file shares to a SAN LUN and assumes individual client laptops can mount iSCSI block storage as if it were an SMB share. It may be true while the current failure persists; the decisive current cause is: Local disks are not automatically visible to other cluster nodes.

D:

This observation tests an unrelated Given a scenario, deploy and manage storage case: A storage team replaces a 10K RPM SAS drive with a consumer SATA model in a tightly specified redundant server array. It may be true while the current failure persists; the decisive current cause is: Local disks are not automatically visible to other cluster nodes.

Question 95

A server operations team encounters the following situation: A virtualization cluster expects live migration through shared storage, yet its design uses only server-local SATA disks. Which underlying cause most specifically explains the observed symptoms?

  1. Dual-parity RAID consumes space equal to two member drive capacities.
  2. Local disks are not automatically visible to other cluster nodes.
  3. One portable disk is a fragile single-copy retention strategy.
  4. Striping without redundancy provides no fault tolerance.

Explanation

Correct Answer

B:

This root-cause explanation directly accounts for the reported condition: A virtualization cluster expects live migration through shared storage, yet its design uses only server-local SATA disks. The corrective step is: Deploy compatible shared block or file storage according to the hypervisor's live-migration requirements. The verifying outcome is: A VM migrates between hosts while retaining access to its disks.

Incorrect Answers

A:

This alternative cause would explain a different case: An administrator assumes four 8 TB disks configured as RAID 6 will provide 32 TB of usable storage. It does not explain the actual incident's evidence. The present cause is: Local disks are not automatically visible to other cluster nodes.

C:

This alternative cause would explain a different case: A backup server uses a single consumer USB SSD as its only long-term archive, although policy requires durable off-site retention. It does not explain the actual incident's evidence. The present cause is: Local disks are not automatically visible to other cluster nodes.

D:

This alternative cause would explain a different case: A critical database stores its write-ahead log and transaction data in RAID 0 for speed despite requiring continued service after one drive failure. It does not explain the actual incident's evidence. The present cause is: Local disks are not automatically visible to other cluster nodes.

Question 96

A server operations team encounters the following situation: A virtualization cluster expects live migration through shared storage, yet its design uses only server-local SATA disks. Which sustained operational control best reduces the likelihood of this same issue recurring?

  1. Check target ACLs and initiator login during storage provisioning.
  2. Require tested capacity calculations for heterogeneous RAID expansions.
  3. Verify shared datastore accessibility from every host before enabling mobility.
  4. Document tolerated failures and rebuild exposure in storage design decisions.

Explanation

Correct Answer

C:

This control targets the underlying recurrence risk: Local disks are not automatically visible to other cluster nodes. It builds validation into the affected workflow and supports the expected recovery result: A VM migrates between hosts while retaining access to its disks.

Incorrect Answers

A:

This control addresses a different scenario: A server is given an iSCSI target IP but never logs in to the target, so the new logical unit is absent in Disk Management. That event's root mechanism was target address entry alone does not establish an iSCSI session or LUN assignment. The described incident instead arises from: Local disks are not automatically visible to other cluster nodes.

B:

This control addresses a different scenario: A team expands an existing RAID 6 pool with dissimilar disks and assumes the full largest disk size contributes from each member. That event's root mechanism was mixed sizes can waste capacity or violate controller layout assumptions. The described incident instead arises from: Local disks are not automatically visible to other cluster nodes.

D:

This control addresses a different scenario: A six-disk RAID 5 array is selected for a workload that must survive two simultaneous disk failures during a rebuild. That event's root mechanism was single-parity RAID 5 does not protect against two concurrent disk failures. The described incident instead arises from: Local disks are not automatically visible to other cluster nodes.

Question 97

A server operations team encounters the following situation: A server is given an iSCSI target IP but never logs in to the target, so the new logical unit is absent in Disk Management. Given the stated symptoms and constraints, which corrective action is the best next step?

  1. Configure initiator discovery, target authentication and the required storage network path.
  2. Deploy compatible shared block or file storage according to the hypervisor's live-migration requirements.
  3. Calculate usable capacity with redundancy, snapshots and projected growth headroom.
  4. Use a suitably sized RAID 6 or another validated two-failure-tolerant design.

Explanation

Correct Answer

A:

The preferred corrective action directly addresses the incident: A server is given an iSCSI target IP but never logs in to the target, so the new logical unit is absent in Disk Management. The fault mechanism is target address entry alone does not establish an iSCSI session or LUN assignment. Expected confirmation is: The authorized LUN appears to the intended initiator without exposing it to other hosts.

Incorrect Answers

B:

This action is better suited to a separate Given a scenario, deploy and manage storage incident: A virtualization cluster expects live migration through shared storage, yet its design uses only server-local SATA disks. That case involves: Local disks are not automatically visible to other cluster nodes. Here the observed mechanism is instead: Target address entry alone does not establish an iSCSI session or LUN assignment. Applying the other repair would not directly resolve this fault.

C:

This action is better suited to a separate Given a scenario, deploy and manage storage incident: A capacity planner chooses a raw 24 TB storage shelf for a 22 TB dataset without space for RAID overhead, snapshots or growth. That case involves: Raw nameplate bytes overstate application-usable storage. Here the observed mechanism is instead: Target address entry alone does not establish an iSCSI session or LUN assignment. Applying the other repair would not directly resolve this fault.

D:

This action is better suited to a separate Given a scenario, deploy and manage storage incident: A six-disk RAID 5 array is selected for a workload that must survive two simultaneous disk failures during a rebuild. That case involves: Single-parity RAID 5 does not protect against two concurrent disk failures. Here the observed mechanism is instead: Target address entry alone does not establish an iSCSI session or LUN assignment. Applying the other repair would not directly resolve this fault.

Question 98

A server operations team encounters the following situation: A server is given an iSCSI target IP but never logs in to the target, so the new logical unit is absent in Disk Management. After making the corrective change, which result best demonstrates that this particular problem is resolved?

  1. Clients access files through SMB while the server owns and manages the block filesystem.
  2. The authorized LUN appears to the intended initiator without exposing it to other hosts.
  3. A dated archive remains restorable after the local USB device is unavailable.
  4. A VM migrates between hosts while retaining access to its disks.

Explanation

Correct Answer

B:

This is incident-specific acceptance evidence: The authorized LUN appears to the intended initiator without exposing it to other hosts. It verifies the action configure initiator discovery, target authentication and the required storage network path. The failure under test was: Target address entry alone does not establish an iSCSI session or LUN assignment.

Incorrect Answers

A:

This observation tests an unrelated Given a scenario, deploy and manage storage case: An administrator migrates file shares to a SAN LUN and assumes individual client laptops can mount iSCSI block storage as if it were an SMB share. It may be true while the current failure persists; the decisive current cause is: Target address entry alone does not establish an iSCSI session or LUN assignment.

C:

This observation tests an unrelated Given a scenario, deploy and manage storage case: A backup server uses a single consumer USB SSD as its only long-term archive, although policy requires durable off-site retention. It may be true while the current failure persists; the decisive current cause is: Target address entry alone does not establish an iSCSI session or LUN assignment.

D:

This observation tests an unrelated Given a scenario, deploy and manage storage case: A virtualization cluster expects live migration through shared storage, yet its design uses only server-local SATA disks. It may be true while the current failure persists; the decisive current cause is: Target address entry alone does not establish an iSCSI session or LUN assignment.

Question 99

A server operations team encounters the following situation: A server is given an iSCSI target IP but never logs in to the target, so the new logical unit is absent in Disk Management. Which underlying cause most specifically explains the observed symptoms?

  1. Drive endurance classes should match actual read-write patterns rather than blanket maximum ratings.
  2. Unprotected controller cache cannot safely preserve acknowledged writes across a power loss.
  3. Target address entry alone does not establish an iSCSI session or LUN assignment.
  4. Raw nameplate bytes overstate application-usable storage.

Explanation

Correct Answer

C:

This root-cause explanation directly accounts for the reported condition: A server is given an iSCSI target IP but never logs in to the target, so the new logical unit is absent in Disk Management. The corrective step is: Configure initiator discovery, target authentication and the required storage network path. The verifying outcome is: The authorized LUN appears to the intended initiator without exposing it to other hosts.

Incorrect Answers

A:

This alternative cause would explain a different case: A high-density read cache uses write-intensive SSDs with excessive cost while backend workloads are predominantly sequential reads. It does not explain the actual incident's evidence. The present cause is: Target address entry alone does not establish an iSCSI session or LUN assignment.

B:

This alternative cause would explain a different case: A RAID array reports write-back cache disabled after its battery protection module failed, and transaction throughput drops sharply. It does not explain the actual incident's evidence. The present cause is: Target address entry alone does not establish an iSCSI session or LUN assignment.

D:

This alternative cause would explain a different case: A capacity planner chooses a raw 24 TB storage shelf for a 22 TB dataset without space for RAID overhead, snapshots or growth. It does not explain the actual incident's evidence. The present cause is: Target address entry alone does not establish an iSCSI session or LUN assignment.

Question 100

A server operations team encounters the following situation: A server is given an iSCSI target IP but never logs in to the target, so the new logical unit is absent in Disk Management. Which sustained operational control best reduces the likelihood of this same issue recurring?

  1. Document initiator ownership and client file-sharing responsibilities.
  2. Review shared-disk ownership and fencing before multi-host presentation.
  3. Maintain actual used-versus-usable capacity forecasts for storage expansions.
  4. Check target ACLs and initiator login during storage provisioning.

Explanation

Correct Answer

D:

This control targets the underlying recurrence risk: Target address entry alone does not establish an iSCSI session or LUN assignment. It builds validation into the affected workflow and supports the expected recovery result: The authorized LUN appears to the intended initiator without exposing it to other hosts.

Incorrect Answers

A:

This control addresses a different scenario: An administrator migrates file shares to a SAN LUN and assumes individual client laptops can mount iSCSI block storage as if it were an SMB share. That event's root mechanism was sAN block presentation and NAS file access serve different layers. The described incident instead arises from: Target address entry alone does not establish an iSCSI session or LUN assignment.

B:

This control addresses a different scenario: A SAN volume is assigned to two standalone Windows servers without cluster-aware filesystem controls, and its filesystem becomes corrupt. That event's root mechanism was ordinary filesystem drivers cannot safely coordinate unsupervised simultaneous raw block writers. The described incident instead arises from: Target address entry alone does not establish an iSCSI session or LUN assignment.

C:

This control addresses a different scenario: A capacity planner chooses a raw 24 TB storage shelf for a 22 TB dataset without space for RAID overhead, snapshots or growth. That event's root mechanism was raw nameplate bytes overstate application-usable storage. The described incident instead arises from: Target address entry alone does not establish an iSCSI session or LUN assignment.