Get Real SK0-005 Exam Questions & Expert Verified Answers as Experienced on the Real Exam!

  • Questions & Answers

    SK0-005 Questions & Answers

    617 Questions & Answers

    The ultimate exam preparation tool, Questions & Answers mirrors the actual SK0-005 exam while allowing you to hone and measure every aspect of your test-taking ability.

  • SK0-005 Video Course

    SK0-005 Video Course

    139 Video Lectures

    SK0-005 Video Course is developed by CompTIA Professionals to help you pass the SK0-005 exam.

    Description

    This course will improve your knowledge and skills required to pass CompTIA Server+ Certification Exam exam.
  • Study Guide

    SK0-005 Study Guide

    533 PDF Pages

    Developed by industry experts, this 533-page guide spells out in painstaking detail all of the information you need to ace SK0-005 exam.

CompTIA Server+ Certification Exam (SK0-005) Practice Tests

Satisfaction Guaranteed

Money Back Guarantee

Testking provides hassle-free money back guarantee with our products. That is because we have 100% trust in the abilities of our professional and experience product team, and our record is a proof of that.

99.6% PASS RATE
Total Cost: $194.97
Bundle Price: $149.98

Purchase Individually

  • Questions & Answers

    Questions & Answers

    617 Questions

    $124.99
  • SK0-005 Video Course

    Video Course

    139 Video Lectures

    $39.99
  • Study Guide

    Study Guide

    533 PDF Pages

    $29.99

CompTIA SK0-005 Practice Test 5

Question 40

A server operations team encounters the following situation: A 42U rack is filled with servers without any blanking panels, and inlet temperatures rise despite adequate room cooling. Which sustained operational control best reduces the likelihood of this same issue recurring?

  1. Include airflow blanking and cable openings in rack inspections.
  2. Verify wavelength, media type and connector specifications for each fiber run.
  3. Include PDU-to-circuit tracing in redundant power acceptance.
  4. Inventory panel termination and pluggable interfaces before purchasing.

Explanation

Correct Answer

A:

This control targets the underlying recurrence risk: Recirculation through unfilled gaps undermines the hot-aisle and cold-aisle arrangement. It builds validation into the affected workflow and supports the expected recovery result: Inlet temperature falls under the same room supply-air conditions.

Incorrect Answers

B:

This control addresses a different scenario: Technicians install an active 10GbE optical link using a multimode transceiver at one end and a single-mode optic at the other. That event's root mechanism was mismatched transceiver and fiber specifications prevent a valid optical link. The described incident instead arises from: Recirculation through unfilled gaps undermines the hot-aisle and cold-aisle arrangement.

C:

This control addresses a different scenario: A branch installs both redundant PSU cords into the same power strip even though two independent protected circuits are available. That event's root mechanism was two supplies share one upstream electrical failure domain. The described incident instead arises from: Recirculation through unfilled gaps undermines the hot-aisle and cold-aisle arrangement.

D:

This control addresses a different scenario: A mixed-fiber patch panel uses LC duplex ports but the ordered switch transceivers expect an unrelated connector type. That event's root mechanism was physical connector compatibility is required in addition to optical signal compatibility. The described incident instead arises from: Recirculation through unfilled gaps undermines the hot-aisle and cold-aisle arrangement.

Question 41

A server operations team encounters the following situation: A compact server cabinet is placed against a wall that blocks its rear exhaust, and upper nodes throttle during batch workloads. Given the stated symptoms and constraints, which corrective action is the best next step?

  1. Provide redundant NIC paths to independent switches with a compatible teaming design.
  2. Reinstall cabling certified for the negotiated speed and measured channel length.
  3. Provide specified exhaust clearance or relocate the cabinet for correct airflow.
  4. Use suitable lifting equipment and approved two-person handling before mounting.

Explanation

Correct Answer

C:

The preferred corrective action directly addresses the incident: A compact server cabinet is placed against a wall that blocks its rear exhaust, and upper nodes throttle during batch workloads. The fault mechanism is the installation prevents warm exhaust from leaving the cabinet. Expected confirmation is: Thermal sensors remain inside limits under representative sustained processing.

Incorrect Answers

A:

This action is better suited to a separate Given a scenario, install physical hardware incident: Two database hosts share a single switch uplink despite a design requiring link resilience across switch failures. That case involves: An additional cable to the same switch would preserve a common point of failure. Here the observed mechanism is instead: The installation prevents warm exhaust from leaving the cabinet. Applying the other repair would not directly resolve this fault.

B:

This action is better suited to a separate Given a scenario, install physical hardware incident: Technicians use a consumer patch cable for a 10GbE run longer than its specified distance and see frequent cyclic redundancy errors. That case involves: The cabling channel does not meet electrical performance requirements at the selected rate. Here the observed mechanism is instead: The installation prevents warm exhaust from leaving the cabinet. Applying the other repair would not directly resolve this fault.

D:

This action is better suited to a separate Given a scenario, install physical hardware incident: An installation team plans to lift a populated 3U server alone into the top rails in violation of site safe-lift guidance. That case involves: Unsupported manual handling presents a preventable installation safety risk. Here the observed mechanism is instead: The installation prevents warm exhaust from leaving the cabinet. Applying the other repair would not directly resolve this fault.

Question 42

A server operations team encounters the following situation: A compact server cabinet is placed against a wall that blocks its rear exhaust, and upper nodes throttle during batch workloads. After making the corrective change, which result best demonstrates that this particular problem is resolved?

  1. Inlet temperature falls under the same room supply-air conditions.
  2. POST and hardware inventory recognize the approved GPU after installation.
  3. Disconnecting one switch leaves tested database access functional.
  4. Thermal sensors remain inside limits under representative sustained processing.

Explanation

Correct Answer

D:

This is incident-specific acceptance evidence: Thermal sensors remain inside limits under representative sustained processing. It verifies the action provide specified exhaust clearance or relocate the cabinet for correct airflow. The failure under test was: The installation prevents warm exhaust from leaving the cabinet.

Incorrect Answers

A:

This observation tests an unrelated Given a scenario, install physical hardware case: A 42U rack is filled with servers without any blanking panels, and inlet temperatures rise despite adequate room cooling. It may be true while the current failure persists; the decisive current cause is: The installation prevents warm exhaust from leaving the cabinet.

B:

This observation tests an unrelated Given a scenario, install physical hardware case: A rack-mount GPU server requires a PCIe slot layout unsupported by the selected motherboard revision, although its CPU count is adequate. It may be true while the current failure persists; the decisive current cause is: The installation prevents warm exhaust from leaving the cabinet.

C:

This observation tests an unrelated Given a scenario, install physical hardware case: Two database hosts share a single switch uplink despite a design requiring link resilience across switch failures. It may be true while the current failure persists; the decisive current cause is: The installation prevents warm exhaust from leaving the cabinet.

Question 43

A server operations team encounters the following situation: A compact server cabinet is placed against a wall that blocks its rear exhaust, and upper nodes throttle during batch workloads. Which underlying cause most specifically explains the observed symptoms?

  1. The installation prevents warm exhaust from leaving the cabinet.
  2. Processor capacity does not establish PCIe mechanical and electrical compatibility.
  3. The rack demand exceeds its available safe power capacity.
  4. The cabling channel does not meet electrical performance requirements at the selected rate.

Explanation

Correct Answer

A:

This root-cause explanation directly accounts for the reported condition: A compact server cabinet is placed against a wall that blocks its rear exhaust, and upper nodes throttle during batch workloads. The corrective step is: Provide specified exhaust clearance or relocate the cabinet for correct airflow. The verifying outcome is: Thermal sensors remain inside limits under representative sustained processing.

Incorrect Answers

B:

This alternative cause would explain a different case: A rack-mount GPU server requires a PCIe slot layout unsupported by the selected motherboard revision, although its CPU count is adequate. It does not explain the actual incident's evidence. The present cause is: The installation prevents warm exhaust from leaving the cabinet.

C:

This alternative cause would explain a different case: An analytics rack's connected servers draw 6.8 kW, while the only installed PDU is rated for 5 kW continuous load. It does not explain the actual incident's evidence. The present cause is: The installation prevents warm exhaust from leaving the cabinet.

D:

This alternative cause would explain a different case: Technicians use a consumer patch cable for a 10GbE run longer than its specified distance and see frequent cyclic redundancy errors. It does not explain the actual incident's evidence. The present cause is: The installation prevents warm exhaust from leaving the cabinet.

Question 44

A server operations team encounters the following situation: A compact server cabinet is placed against a wall that blocks its rear exhaust, and upper nodes throttle during batch workloads. Which sustained operational control best reduces the likelihood of this same issue recurring?

  1. Include airflow blanking and cable openings in rack inspections.
  2. Check front and rear clearance against manufacturer installation guidance.
  3. Include PDU-to-circuit tracing in redundant power acceptance.
  4. Validate expansion-card requirements against model-specific vendor HCLs.

Explanation

Correct Answer

B:

This control targets the underlying recurrence risk: The installation prevents warm exhaust from leaving the cabinet. It builds validation into the affected workflow and supports the expected recovery result: Thermal sensors remain inside limits under representative sustained processing.

Incorrect Answers

A:

This control addresses a different scenario: A 42U rack is filled with servers without any blanking panels, and inlet temperatures rise despite adequate room cooling. That event's root mechanism was recirculation through unfilled gaps undermines the hot-aisle and cold-aisle arrangement. The described incident instead arises from: The installation prevents warm exhaust from leaving the cabinet.

C:

This control addresses a different scenario: A branch installs both redundant PSU cords into the same power strip even though two independent protected circuits are available. That event's root mechanism was two supplies share one upstream electrical failure domain. The described incident instead arises from: The installation prevents warm exhaust from leaving the cabinet.

D:

This control addresses a different scenario: A rack-mount GPU server requires a PCIe slot layout unsupported by the selected motherboard revision, although its CPU count is adequate. That event's root mechanism was processor capacity does not establish PCIe mechanical and electrical compatibility. The described incident instead arises from: The installation prevents warm exhaust from leaving the cabinet.

Question 45

A server operations team encounters the following situation: A new blade chassis is connected to the network before its enclosure-level shared power and cooling redundancy has been configured. Given the stated symptoms and constraints, which corrective action is the best next step?

  1. Check the hardware compatibility list and select a supported board or GPU layout.
  2. Obtain approved rack rail kits and test attachment before installing the chassis.
  3. Fit a compatible rack KVM or approved out-of-band console design for all managed servers.
  4. Validate redundant enclosure power, fans and interconnect paths prior to blade deployment.

Explanation

Correct Answer

D:

The preferred corrective action directly addresses the incident: A new blade chassis is connected to the network before its enclosure-level shared power and cooling redundancy has been configured. The fault mechanism is shared chassis infrastructure creates failure domains beyond individual blades. Expected confirmation is: A controlled fan or power-module failure preserves supported blade operation.

Incorrect Answers

A:

This action is better suited to a separate Given a scenario, install physical hardware incident: A rack-mount GPU server requires a PCIe slot layout unsupported by the selected motherboard revision, although its CPU count is adequate. That case involves: Processor capacity does not establish PCIe mechanical and electrical compatibility. Here the observed mechanism is instead: Shared chassis infrastructure creates failure domains beyond individual blades. Applying the other repair would not directly resolve this fault.

B:

This action is better suited to a separate Given a scenario, install physical hardware incident: A new 2U compute node ships with universal sliding rails that do not match the data center's square-hole posts. That case involves: An incompatible mounting rail cannot provide a verified secure server installation. Here the observed mechanism is instead: Shared chassis infrastructure creates failure domains beyond individual blades. Applying the other repair would not directly resolve this fault.

C:

This action is better suited to a separate Given a scenario, install physical hardware incident: A new remote rack has a KVM console accessible only by disconnecting active production monitor cables. That case involves: The chosen console access workflow is not operationally maintainable. Here the observed mechanism is instead: Shared chassis infrastructure creates failure domains beyond individual blades. Applying the other repair would not directly resolve this fault.

Question 46

A server operations team encounters the following situation: A new blade chassis is connected to the network before its enclosure-level shared power and cooling redundancy has been configured. After making the corrective change, which result best demonstrates that this particular problem is resolved?

  1. A controlled fan or power-module failure preserves supported blade operation.
  2. Disconnecting one switch leaves tested database access functional.
  3. The negotiated rate reaches 10GbE with no persistent physical errors.
  4. Cable certification and port error counters meet the link acceptance criteria.

Explanation

Correct Answer

A:

This is incident-specific acceptance evidence: A controlled fan or power-module failure preserves supported blade operation. It verifies the action validate redundant enclosure power, fans and interconnect paths prior to blade deployment. The failure under test was: Shared chassis infrastructure creates failure domains beyond individual blades.

Incorrect Answers

B:

This observation tests an unrelated Given a scenario, install physical hardware case: Two database hosts share a single switch uplink despite a design requiring link resilience across switch failures. It may be true while the current failure persists; the decisive current cause is: Shared chassis infrastructure creates failure domains beyond individual blades.

C:

This observation tests an unrelated Given a scenario, install physical hardware case: A new 10GbE NIC is fitted with a 1GbE-only SFP module, and a storage transfer cannot reach its specified link rate. It may be true while the current failure persists; the decisive current cause is: Shared chassis infrastructure creates failure domains beyond individual blades.

D:

This observation tests an unrelated Given a scenario, install physical hardware case: Technicians use a consumer patch cable for a 10GbE run longer than its specified distance and see frequent cyclic redundancy errors. It may be true while the current failure persists; the decisive current cause is: Shared chassis infrastructure creates failure domains beyond individual blades.

Question 47

A server operations team encounters the following situation: A new blade chassis is connected to the network before its enclosure-level shared power and cooling redundancy has been configured. Which underlying cause most specifically explains the observed symptoms?

  1. Two supplies share one upstream electrical failure domain.
  2. Shared chassis infrastructure creates failure domains beyond individual blades.
  3. Recirculation through unfilled gaps undermines the hot-aisle and cold-aisle arrangement.
  4. High center of gravity and unverified floor loading create a personnel and stability hazard.

Explanation

Correct Answer

B:

This root-cause explanation directly accounts for the reported condition: A new blade chassis is connected to the network before its enclosure-level shared power and cooling redundancy has been configured. The corrective step is: Validate redundant enclosure power, fans and interconnect paths prior to blade deployment. The verifying outcome is: A controlled fan or power-module failure preserves supported blade operation.

Incorrect Answers

A:

This alternative cause would explain a different case: A branch installs both redundant PSU cords into the same power strip even though two independent protected circuits are available. It does not explain the actual incident's evidence. The present cause is: Shared chassis infrastructure creates failure domains beyond individual blades.

C:

This alternative cause would explain a different case: A 42U rack is filled with servers without any blanking panels, and inlet temperatures rise despite adequate room cooling. It does not explain the actual incident's evidence. The present cause is: Shared chassis infrastructure creates failure domains beyond individual blades.

D:

This alternative cause would explain a different case: A heavy UPS is planned above lightly loaded servers in a rack that maintenance technicians frequently roll across a raised floor. It does not explain the actual incident's evidence. The present cause is: Shared chassis infrastructure creates failure domains beyond individual blades.

Question 48

A server operations team encounters the following situation: A new blade chassis is connected to the network before its enclosure-level shared power and cooling redundancy has been configured. Which sustained operational control best reduces the likelihood of this same issue recurring?

  1. Keep optical part numbers tied to port speed requirements.
  2. Train teams and stage lifting resources for heavy chassis deliveries.
  3. Document enclosure-level fault tests as part of blade installation.
  4. Cross-check HCL expansion-slot and port counts before purchase.

Explanation

Correct Answer

C:

This control targets the underlying recurrence risk: Shared chassis infrastructure creates failure domains beyond individual blades. It builds validation into the affected workflow and supports the expected recovery result: A controlled fan or power-module failure preserves supported blade operation.

Incorrect Answers

A:

This control addresses a different scenario: A new 10GbE NIC is fitted with a 1GbE-only SFP module, and a storage transfer cannot reach its specified link rate. That event's root mechanism was the installed pluggable is not capable of the intended link speed. The described incident instead arises from: Shared chassis infrastructure creates failure domains beyond individual blades.

B:

This control addresses a different scenario: An installation team plans to lift a populated 3U server alone into the top rails in violation of site safe-lift guidance. That event's root mechanism was unsupported manual handling presents a preventable installation safety risk. The described incident instead arises from: Shared chassis infrastructure creates failure domains beyond individual blades.

D:

This control addresses a different scenario: An expansion server needs four network ports, but the small-form chassis lacks enough PCIe slots for the specified add-in NICs. That event's root mechanism was the proposed physical expansion count exceeds chassis slot capacity. The described incident instead arises from: Shared chassis infrastructure creates failure domains beyond individual blades.

Question 49

A server operations team encounters the following situation: Technicians use a consumer patch cable for a 10GbE run longer than its specified distance and see frequent cyclic redundancy errors. Given the stated symptoms and constraints, which corrective action is the best next step?

  1. Reinstall cabling certified for the negotiated speed and measured channel length.
  2. Recalculate runtime at the proposed load and expand supported UPS capacity or reduce demand.
  3. Validate redundant enclosure power, fans and interconnect paths prior to blade deployment.
  4. Fit a compatible rack KVM or approved out-of-band console design for all managed servers.

Explanation

Correct Answer

A:

The preferred corrective action directly addresses the incident: Technicians use a consumer patch cable for a 10GbE run longer than its specified distance and see frequent cyclic redundancy errors. The fault mechanism is the cabling channel does not meet electrical performance requirements at the selected rate. Expected confirmation is: Cable certification and port error counters meet the link acceptance criteria.

Incorrect Answers

B:

This action is better suited to a separate Given a scenario, install physical hardware incident: One site's new rack consumes more power than two UPS battery strings can support for the required graceful shutdown window. That case involves: Battery runtime depends on actual load, not just the UPS nameplate apparent power. Here the observed mechanism is instead: The cabling channel does not meet electrical performance requirements at the selected rate. Applying the other repair would not directly resolve this fault.

C:

This action is better suited to a separate Given a scenario, install physical hardware incident: A new blade chassis is connected to the network before its enclosure-level shared power and cooling redundancy has been configured. That case involves: Shared chassis infrastructure creates failure domains beyond individual blades. Here the observed mechanism is instead: The cabling channel does not meet electrical performance requirements at the selected rate. Applying the other repair would not directly resolve this fault.

D:

This action is better suited to a separate Given a scenario, install physical hardware incident: A new remote rack has a KVM console accessible only by disconnecting active production monitor cables. That case involves: The chosen console access workflow is not operationally maintainable. Here the observed mechanism is instead: The cabling channel does not meet electrical performance requirements at the selected rate. Applying the other repair would not directly resolve this fault.

Question 50

A server operations team encounters the following situation: Technicians use a consumer patch cable for a 10GbE run longer than its specified distance and see frequent cyclic redundancy errors. After making the corrective change, which result best demonstrates that this particular problem is resolved?

  1. POST and hardware inventory recognize the approved GPU after installation.
  2. Cable certification and port error counters meet the link acceptance criteria.
  3. All four network paths enumerate and carry approved traffic after installation.
  4. Equipment is secured without injury or damage during a supervised lift.

Explanation

Correct Answer

B:

This is incident-specific acceptance evidence: Cable certification and port error counters meet the link acceptance criteria. It verifies the action reinstall cabling certified for the negotiated speed and measured channel length. The failure under test was: The cabling channel does not meet electrical performance requirements at the selected rate.

Incorrect Answers

A:

This observation tests an unrelated Given a scenario, install physical hardware case: A rack-mount GPU server requires a PCIe slot layout unsupported by the selected motherboard revision, although its CPU count is adequate. It may be true while the current failure persists; the decisive current cause is: The cabling channel does not meet electrical performance requirements at the selected rate.

C:

This observation tests an unrelated Given a scenario, install physical hardware case: An expansion server needs four network ports, but the small-form chassis lacks enough PCIe slots for the specified add-in NICs. It may be true while the current failure persists; the decisive current cause is: The cabling channel does not meet electrical performance requirements at the selected rate.

D:

This observation tests an unrelated Given a scenario, install physical hardware case: An installation team plans to lift a populated 3U server alone into the top rails in violation of site safe-lift guidance. It may be true while the current failure persists; the decisive current cause is: The cabling channel does not meet electrical performance requirements at the selected rate.