McAfee-Secured Website

Exam Bundle

Exam Code: SK0-005

Exam Name CompTIA Server+ Certification Exam

Certification Provider: CompTIA

Corresponding Certification: CompTIA Server+

CompTIA SK0-005 Bundle $44.99

100% CompTIA SK0-005 Guaranteed Success With Testking Training Materials

Get Real SK0-005 Exam Questions & Expert Verified Answers as Experienced on the Real Exam!

  • Questions & Answers

    SK0-005 Questions & Answers

    617 Questions & Answers

    The ultimate exam preparation tool, Questions & Answers mirrors the actual SK0-005 exam while allowing you to hone and measure every aspect of your test-taking ability.

  • SK0-005 Video Course

    SK0-005 Video Course

    139 Video Lectures

    SK0-005 Video Course is developed by CompTIA Professionals to help you pass the SK0-005 exam.

    Description

    This course will improve your knowledge and skills required to pass CompTIA Server+ Certification Exam exam.
  • Study Guide

    SK0-005 Study Guide

    533 PDF Pages

    Developed by industry experts, this 533-page guide spells out in painstaking detail all of the information you need to ace SK0-005 exam.

CompTIA Server+ Certification Exam (SK0-005) Practice Tests

Satisfaction Guaranteed

Money Back Guarantee

Testking provides hassle-free money back guarantee with our products. That is because we have 100% trust in the abilities of our professional and experience product team, and our record is a proof of that.

99.6% PASS RATE
Total Cost: $194.97
Bundle Price: $149.98

Purchase Individually

  • Questions & Answers

    Questions & Answers

    617 Questions

    $124.99
  • SK0-005 Video Course

    Video Course

    139 Video Lectures

    $39.99
  • Study Guide

    Study Guide

    533 PDF Pages

    $29.99

CompTIA SK0-005 Practice Test 4

Question 30

A server operations team encounters the following situation: Two database hosts share a single switch uplink despite a design requiring link resilience across switch failures. After making the corrective change, which result best demonstrates that this particular problem is resolved?

  1. Disconnecting one switch leaves tested database access functional.
  2. The revised rack passes load and tip-risk inspection before energizing.
  3. A load test demonstrates the declared time to orderly shutdown.
  4. The link negotiates reliably and shows acceptable optical diagnostics and error counters.

Explanation

Correct Answer

A:

This is incident-specific acceptance evidence: Disconnecting one switch leaves tested database access functional. It verifies the action provide redundant NIC paths to independent switches with a compatible teaming design. The failure under test was: An additional cable to the same switch would preserve a common point of failure.

Incorrect Answers

B:

This observation tests an unrelated Given a scenario, install physical hardware case: A heavy UPS is planned above lightly loaded servers in a rack that maintenance technicians frequently roll across a raised floor. It may be true while the current failure persists; the decisive current cause is: An additional cable to the same switch would preserve a common point of failure.

C:

This observation tests an unrelated Given a scenario, install physical hardware case: One site's new rack consumes more power than two UPS battery strings can support for the required graceful shutdown window. It may be true while the current failure persists; the decisive current cause is: An additional cable to the same switch would preserve a common point of failure.

D:

This observation tests an unrelated Given a scenario, install physical hardware case: Technicians install an active 10GbE optical link using a multimode transceiver at one end and a single-mode optic at the other. It may be true while the current failure persists; the decisive current cause is: An additional cable to the same switch would preserve a common point of failure.

Question 31

A server operations team encounters the following situation: Two database hosts share a single switch uplink despite a design requiring link resilience across switch failures. Which underlying cause most specifically explains the observed symptoms?

  1. The cabling channel does not meet electrical performance requirements at the selected rate.
  2. An additional cable to the same switch would preserve a common point of failure.
  3. The chosen console access workflow is not operationally maintainable.
  4. An incompatible mounting rail cannot provide a verified secure server installation.

Explanation

Correct Answer

B:

This root-cause explanation directly accounts for the reported condition: Two database hosts share a single switch uplink despite a design requiring link resilience across switch failures. The corrective step is: Provide redundant NIC paths to independent switches with a compatible teaming design. The verifying outcome is: Disconnecting one switch leaves tested database access functional.

Incorrect Answers

A:

This alternative cause would explain a different case: Technicians use a consumer patch cable for a 10GbE run longer than its specified distance and see frequent cyclic redundancy errors. It does not explain the actual incident's evidence. The present cause is: An additional cable to the same switch would preserve a common point of failure.

C:

This alternative cause would explain a different case: A new remote rack has a KVM console accessible only by disconnecting active production monitor cables. It does not explain the actual incident's evidence. The present cause is: An additional cable to the same switch would preserve a common point of failure.

D:

This alternative cause would explain a different case: A new 2U compute node ships with universal sliding rails that do not match the data center's square-hole posts. It does not explain the actual incident's evidence. The present cause is: An additional cable to the same switch would preserve a common point of failure.

Question 32

A server operations team encounters the following situation: Two database hosts share a single switch uplink despite a design requiring link resilience across switch failures. Which sustained operational control best reduces the likelihood of this same issue recurring?

  1. Cross-check HCL expansion-slot and port counts before purchase.
  2. Require tested cable category and length documentation for high-speed ports.
  3. Trace each redundant network path end-to-end during commissioning.
  4. Check front and rear clearance against manufacturer installation guidance.

Explanation

Correct Answer

C:

This control targets the underlying recurrence risk: An additional cable to the same switch would preserve a common point of failure. It builds validation into the affected workflow and supports the expected recovery result: Disconnecting one switch leaves tested database access functional.

Incorrect Answers

A:

This control addresses a different scenario: An expansion server needs four network ports, but the small-form chassis lacks enough PCIe slots for the specified add-in NICs. That event's root mechanism was the proposed physical expansion count exceeds chassis slot capacity. The described incident instead arises from: An additional cable to the same switch would preserve a common point of failure.

B:

This control addresses a different scenario: Technicians use a consumer patch cable for a 10GbE run longer than its specified distance and see frequent cyclic redundancy errors. That event's root mechanism was the cabling channel does not meet electrical performance requirements at the selected rate. The described incident instead arises from: An additional cable to the same switch would preserve a common point of failure.

D:

This control addresses a different scenario: A compact server cabinet is placed against a wall that blocks its rear exhaust, and upper nodes throttle during batch workloads. That event's root mechanism was the installation prevents warm exhaust from leaving the cabinet. The described incident instead arises from: An additional cable to the same switch would preserve a common point of failure.

Question 33

A server operations team encounters the following situation: A rack-mount GPU server requires a PCIe slot layout unsupported by the selected motherboard revision, although its CPU count is adequate. Given the stated symptoms and constraints, which corrective action is the best next step?

  1. Check the hardware compatibility list and select a supported board or GPU layout.
  2. Replan rack space and obtain a compatible enclosure location before delivery.
  3. Provide specified exhaust clearance or relocate the cabinet for correct airflow.
  4. Validate redundant enclosure power, fans and interconnect paths prior to blade deployment.

Explanation

Correct Answer

A:

The preferred corrective action directly addresses the incident: A rack-mount GPU server requires a PCIe slot layout unsupported by the selected motherboard revision, although its CPU count is adequate. The fault mechanism is processor capacity does not establish PCIe mechanical and electrical compatibility. Expected confirmation is: POST and hardware inventory recognize the approved GPU after installation.

Incorrect Answers

B:

This action is better suited to a separate Given a scenario, install physical hardware incident: A hospital orders 4U blade enclosures but the existing 24U rack has only 2U contiguous free space near its reserved airflow corridor. That case involves: Available total units do not imply an enclosure can occupy fragmented rack space. Here the observed mechanism is instead: Processor capacity does not establish PCIe mechanical and electrical compatibility. Applying the other repair would not directly resolve this fault.

C:

This action is better suited to a separate Given a scenario, install physical hardware incident: A compact server cabinet is placed against a wall that blocks its rear exhaust, and upper nodes throttle during batch workloads. That case involves: The installation prevents warm exhaust from leaving the cabinet. Here the observed mechanism is instead: Processor capacity does not establish PCIe mechanical and electrical compatibility. Applying the other repair would not directly resolve this fault.

D:

This action is better suited to a separate Given a scenario, install physical hardware incident: A new blade chassis is connected to the network before its enclosure-level shared power and cooling redundancy has been configured. That case involves: Shared chassis infrastructure creates failure domains beyond individual blades. Here the observed mechanism is instead: Processor capacity does not establish PCIe mechanical and electrical compatibility. Applying the other repair would not directly resolve this fault.

Question 34

A server operations team encounters the following situation: A rack-mount GPU server requires a PCIe slot layout unsupported by the selected motherboard revision, although its CPU count is adequate. After making the corrective change, which result best demonstrates that this particular problem is resolved?

  1. The revised rack passes load and tip-risk inspection before energizing.
  2. POST and hardware inventory recognize the approved GPU after installation.
  3. Inlet temperature falls under the same room supply-air conditions.
  4. Cable certification and port error counters meet the link acceptance criteria.

Explanation

Correct Answer

B:

This is incident-specific acceptance evidence: POST and hardware inventory recognize the approved GPU after installation. It verifies the action check the hardware compatibility list and select a supported board or GPU layout. The failure under test was: Processor capacity does not establish PCIe mechanical and electrical compatibility.

Incorrect Answers

A:

This observation tests an unrelated Given a scenario, install physical hardware case: A heavy UPS is planned above lightly loaded servers in a rack that maintenance technicians frequently roll across a raised floor. It may be true while the current failure persists; the decisive current cause is: Processor capacity does not establish PCIe mechanical and electrical compatibility.

C:

This observation tests an unrelated Given a scenario, install physical hardware case: A 42U rack is filled with servers without any blanking panels, and inlet temperatures rise despite adequate room cooling. It may be true while the current failure persists; the decisive current cause is: Processor capacity does not establish PCIe mechanical and electrical compatibility.

D:

This observation tests an unrelated Given a scenario, install physical hardware case: Technicians use a consumer patch cable for a 10GbE run longer than its specified distance and see frequent cyclic redundancy errors. It may be true while the current failure persists; the decisive current cause is: Processor capacity does not establish PCIe mechanical and electrical compatibility.

Question 35

A server operations team encounters the following situation: A rack-mount GPU server requires a PCIe slot layout unsupported by the selected motherboard revision, although its CPU count is adequate. Which underlying cause most specifically explains the observed symptoms?

  1. An incompatible mounting rail cannot provide a verified secure server installation.
  2. The proposed physical expansion count exceeds chassis slot capacity.
  3. Processor capacity does not establish PCIe mechanical and electrical compatibility.
  4. Unsupported manual handling presents a preventable installation safety risk.

Explanation

Correct Answer

C:

This root-cause explanation directly accounts for the reported condition: A rack-mount GPU server requires a PCIe slot layout unsupported by the selected motherboard revision, although its CPU count is adequate. The corrective step is: Check the hardware compatibility list and select a supported board or GPU layout. The verifying outcome is: POST and hardware inventory recognize the approved GPU after installation.

Incorrect Answers

A:

This alternative cause would explain a different case: A new 2U compute node ships with universal sliding rails that do not match the data center's square-hole posts. It does not explain the actual incident's evidence. The present cause is: Processor capacity does not establish PCIe mechanical and electrical compatibility.

B:

This alternative cause would explain a different case: An expansion server needs four network ports, but the small-form chassis lacks enough PCIe slots for the specified add-in NICs. It does not explain the actual incident's evidence. The present cause is: Processor capacity does not establish PCIe mechanical and electrical compatibility.

D:

This alternative cause would explain a different case: An installation team plans to lift a populated 3U server alone into the top rails in violation of site safe-lift guidance. It does not explain the actual incident's evidence. The present cause is: Processor capacity does not establish PCIe mechanical and electrical compatibility.

Question 36

A server operations team encounters the following situation: A rack-mount GPU server requires a PCIe slot layout unsupported by the selected motherboard revision, although its CPU count is adequate. Which sustained operational control best reduces the likelihood of this same issue recurring?

  1. Map local console serviceability in rack layout planning.
  2. Require rack weight distribution and site structural review for each major installation.
  3. Record rack-post type and chassis rail compatibility in procurement checks.
  4. Validate expansion-card requirements against model-specific vendor HCLs.

Explanation

Correct Answer

D:

This control targets the underlying recurrence risk: Processor capacity does not establish PCIe mechanical and electrical compatibility. It builds validation into the affected workflow and supports the expected recovery result: POST and hardware inventory recognize the approved GPU after installation.

Incorrect Answers

A:

This control addresses a different scenario: A new remote rack has a KVM console accessible only by disconnecting active production monitor cables. That event's root mechanism was the chosen console access workflow is not operationally maintainable. The described incident instead arises from: Processor capacity does not establish PCIe mechanical and electrical compatibility.

B:

This control addresses a different scenario: A heavy UPS is planned above lightly loaded servers in a rack that maintenance technicians frequently roll across a raised floor. That event's root mechanism was high center of gravity and unverified floor loading create a personnel and stability hazard. The described incident instead arises from: Processor capacity does not establish PCIe mechanical and electrical compatibility.

C:

This control addresses a different scenario: A new 2U compute node ships with universal sliding rails that do not match the data center's square-hole posts. That event's root mechanism was an incompatible mounting rail cannot provide a verified secure server installation. The described incident instead arises from: Processor capacity does not establish PCIe mechanical and electrical compatibility.

Question 37

A server operations team encounters the following situation: A 42U rack is filled with servers without any blanking panels, and inlet temperatures rise despite adequate room cooling. Given the stated symptoms and constraints, which corrective action is the best next step?

  1. Relocate dense equipment low and verify rack anchoring and floor-load ratings.
  2. Restore front-to-back air separation with blanking panels and appropriate rack airflow.
  3. Replace the incompatible optical module or cable with a matched supported pair.
  4. Replan rack space and obtain a compatible enclosure location before delivery.

Explanation

Correct Answer

B:

The preferred corrective action directly addresses the incident: A 42U rack is filled with servers without any blanking panels, and inlet temperatures rise despite adequate room cooling. The fault mechanism is recirculation through unfilled gaps undermines the hot-aisle and cold-aisle arrangement. Expected confirmation is: Inlet temperature falls under the same room supply-air conditions.

Incorrect Answers

A:

This action is better suited to a separate Given a scenario, install physical hardware incident: A heavy UPS is planned above lightly loaded servers in a rack that maintenance technicians frequently roll across a raised floor. That case involves: High center of gravity and unverified floor loading create a personnel and stability hazard. Here the observed mechanism is instead: Recirculation through unfilled gaps undermines the hot-aisle and cold-aisle arrangement. Applying the other repair would not directly resolve this fault.

C:

This action is better suited to a separate Given a scenario, install physical hardware incident: Technicians install an active 10GbE optical link using a multimode transceiver at one end and a single-mode optic at the other. That case involves: Mismatched transceiver and fiber specifications prevent a valid optical link. Here the observed mechanism is instead: Recirculation through unfilled gaps undermines the hot-aisle and cold-aisle arrangement. Applying the other repair would not directly resolve this fault.

D:

This action is better suited to a separate Given a scenario, install physical hardware incident: A hospital orders 4U blade enclosures but the existing 24U rack has only 2U contiguous free space near its reserved airflow corridor. That case involves: Available total units do not imply an enclosure can occupy fragmented rack space. Here the observed mechanism is instead: Recirculation through unfilled gaps undermines the hot-aisle and cold-aisle arrangement. Applying the other repair would not directly resolve this fault.

Question 38

A server operations team encounters the following situation: A 42U rack is filled with servers without any blanking panels, and inlet temperatures rise despite adequate room cooling. After making the corrective change, which result best demonstrates that this particular problem is resolved?

  1. Disconnecting one switch leaves tested database access functional.
  2. The link negotiates reliably and shows acceptable optical diagnostics and error counters.
  3. Inlet temperature falls under the same room supply-air conditions.
  4. Unplugging either PDU leaves the server powered through the other feed.

Explanation

Correct Answer

C:

This is incident-specific acceptance evidence: Inlet temperature falls under the same room supply-air conditions. It verifies the action restore front-to-back air separation with blanking panels and appropriate rack airflow. The failure under test was: Recirculation through unfilled gaps undermines the hot-aisle and cold-aisle arrangement.

Incorrect Answers

A:

This observation tests an unrelated Given a scenario, install physical hardware case: Two database hosts share a single switch uplink despite a design requiring link resilience across switch failures. It may be true while the current failure persists; the decisive current cause is: Recirculation through unfilled gaps undermines the hot-aisle and cold-aisle arrangement.

B:

This observation tests an unrelated Given a scenario, install physical hardware case: Technicians install an active 10GbE optical link using a multimode transceiver at one end and a single-mode optic at the other. It may be true while the current failure persists; the decisive current cause is: Recirculation through unfilled gaps undermines the hot-aisle and cold-aisle arrangement.

D:

This observation tests an unrelated Given a scenario, install physical hardware case: A branch installs both redundant PSU cords into the same power strip even though two independent protected circuits are available. It may be true while the current failure persists; the decisive current cause is: Recirculation through unfilled gaps undermines the hot-aisle and cold-aisle arrangement.

Question 39

A server operations team encounters the following situation: A 42U rack is filled with servers without any blanking panels, and inlet temperatures rise despite adequate room cooling. Which underlying cause most specifically explains the observed symptoms?

  1. The installation prevents warm exhaust from leaving the cabinet.
  2. Mismatched transceiver and fiber specifications prevent a valid optical link.
  3. An incompatible mounting rail cannot provide a verified secure server installation.
  4. Recirculation through unfilled gaps undermines the hot-aisle and cold-aisle arrangement.

Explanation

Correct Answer

D:

This root-cause explanation directly accounts for the reported condition: A 42U rack is filled with servers without any blanking panels, and inlet temperatures rise despite adequate room cooling. The corrective step is: Restore front-to-back air separation with blanking panels and appropriate rack airflow. The verifying outcome is: Inlet temperature falls under the same room supply-air conditions.

Incorrect Answers

A:

This alternative cause would explain a different case: A compact server cabinet is placed against a wall that blocks its rear exhaust, and upper nodes throttle during batch workloads. It does not explain the actual incident's evidence. The present cause is: Recirculation through unfilled gaps undermines the hot-aisle and cold-aisle arrangement.

B:

This alternative cause would explain a different case: Technicians install an active 10GbE optical link using a multimode transceiver at one end and a single-mode optic at the other. It does not explain the actual incident's evidence. The present cause is: Recirculation through unfilled gaps undermines the hot-aisle and cold-aisle arrangement.

C:

This alternative cause would explain a different case: A new 2U compute node ships with universal sliding rails that do not match the data center's square-hole posts. It does not explain the actual incident's evidence. The present cause is: Recirculation through unfilled gaps undermines the hot-aisle and cold-aisle arrangement.

Question 40

A server operations team encounters the following situation: A 42U rack is filled with servers without any blanking panels, and inlet temperatures rise despite adequate room cooling. Which sustained operational control best reduces the likelihood of this same issue recurring?

  1. Include airflow blanking and cable openings in rack inspections.
  2. Verify wavelength, media type and connector specifications for each fiber run.
  3. Include PDU-to-circuit tracing in redundant power acceptance.
  4. Inventory panel termination and pluggable interfaces before purchasing.

Explanation

Correct Answer

A:

This control targets the underlying recurrence risk: Recirculation through unfilled gaps undermines the hot-aisle and cold-aisle arrangement. It builds validation into the affected workflow and supports the expected recovery result: Inlet temperature falls under the same room supply-air conditions.

Incorrect Answers

B:

This control addresses a different scenario: Technicians install an active 10GbE optical link using a multimode transceiver at one end and a single-mode optic at the other. That event's root mechanism was mismatched transceiver and fiber specifications prevent a valid optical link. The described incident instead arises from: Recirculation through unfilled gaps undermines the hot-aisle and cold-aisle arrangement.

C:

This control addresses a different scenario: A branch installs both redundant PSU cords into the same power strip even though two independent protected circuits are available. That event's root mechanism was two supplies share one upstream electrical failure domain. The described incident instead arises from: Recirculation through unfilled gaps undermines the hot-aisle and cold-aisle arrangement.

D:

This control addresses a different scenario: A mixed-fiber patch panel uses LC duplex ports but the ordered switch transceivers expect an unrelated connector type. That event's root mechanism was physical connector compatibility is required in addition to optical signal compatibility. The described incident instead arises from: Recirculation through unfilled gaps undermines the hot-aisle and cold-aisle arrangement.