McAfee-Secured Website

Exam Bundle

Exam Code: SK0-005

Exam Name CompTIA Server+ Certification Exam

Certification Provider: CompTIA

Corresponding Certification: CompTIA Server+

CompTIA SK0-005 Bundle $44.99

100% CompTIA SK0-005 Guaranteed Success With Testking Training Materials

Get Real SK0-005 Exam Questions & Expert Verified Answers as Experienced on the Real Exam!

  • Questions & Answers

    SK0-005 Questions & Answers

    617 Questions & Answers

    The ultimate exam preparation tool, Questions & Answers mirrors the actual SK0-005 exam while allowing you to hone and measure every aspect of your test-taking ability.

  • SK0-005 Video Course

    SK0-005 Video Course

    139 Video Lectures

    SK0-005 Video Course is developed by CompTIA Professionals to help you pass the SK0-005 exam.

    Description

    This course will improve your knowledge and skills required to pass CompTIA Server+ Certification Exam exam.
  • Study Guide

    SK0-005 Study Guide

    533 PDF Pages

    Developed by industry experts, this 533-page guide spells out in painstaking detail all of the information you need to ace SK0-005 exam.

CompTIA Server+ Certification Exam (SK0-005) Practice Tests

Satisfaction Guaranteed

Money Back Guarantee

Testking provides hassle-free money back guarantee with our products. That is because we have 100% trust in the abilities of our professional and experience product team, and our record is a proof of that.

99.6% PASS RATE
Total Cost: $194.97
Bundle Price: $149.98

Purchase Individually

  • Questions & Answers

    Questions & Answers

    617 Questions

    $124.99
  • SK0-005 Video Course

    Video Course

    139 Video Lectures

    $39.99
  • Study Guide

    Study Guide

    533 PDF Pages

    $29.99

CompTIA SK0-005 Practice Test 3

Question 20

A server operations team encounters the following situation: An analytics rack's connected servers draw 6.8 kW, while the only installed PDU is rated for 5 kW continuous load. Which sustained operational control best reduces the likelihood of this same issue recurring?

  1. Cross-check HCL expansion-slot and port counts before purchase.
  2. Trace each redundant network path end-to-end during commissioning.
  3. Include PDU-to-circuit tracing in redundant power acceptance.
  4. Approve measured electrical headroom before each capacity expansion.

Explanation

Correct Answer

D:

This control targets the underlying recurrence risk: The rack demand exceeds its available safe power capacity. It builds validation into the affected workflow and supports the expected recovery result: Meter readings remain within rated continuous circuit and PDU limits under peak load.

Incorrect Answers

A:

This control addresses a different scenario: An expansion server needs four network ports, but the small-form chassis lacks enough PCIe slots for the specified add-in NICs. That event's root mechanism was the proposed physical expansion count exceeds chassis slot capacity. The described incident instead arises from: The rack demand exceeds its available safe power capacity.

B:

This control addresses a different scenario: Two database hosts share a single switch uplink despite a design requiring link resilience across switch failures. That event's root mechanism was an additional cable to the same switch would preserve a common point of failure. The described incident instead arises from: The rack demand exceeds its available safe power capacity.

C:

This control addresses a different scenario: A branch installs both redundant PSU cords into the same power strip even though two independent protected circuits are available. That event's root mechanism was two supplies share one upstream electrical failure domain. The described incident instead arises from: The rack demand exceeds its available safe power capacity.

Question 21

A server operations team encounters the following situation: Technicians install an active 10GbE optical link using a multimode transceiver at one end and a single-mode optic at the other. Given the stated symptoms and constraints, which corrective action is the best next step?

  1. Obtain approved rack rail kits and test attachment before installing the chassis.
  2. Replace the incompatible optical module or cable with a matched supported pair.
  3. Recalculate power budget and provision sufficient rated redundant distribution before activation.
  4. Validate redundant enclosure power, fans and interconnect paths prior to blade deployment.

Explanation

Correct Answer

B:

The preferred corrective action directly addresses the incident: Technicians install an active 10GbE optical link using a multimode transceiver at one end and a single-mode optic at the other. The fault mechanism is mismatched transceiver and fiber specifications prevent a valid optical link. Expected confirmation is: The link negotiates reliably and shows acceptable optical diagnostics and error counters.

Incorrect Answers

A:

This action is better suited to a separate Given a scenario, install physical hardware incident: A new 2U compute node ships with universal sliding rails that do not match the data center's square-hole posts. That case involves: An incompatible mounting rail cannot provide a verified secure server installation. Here the observed mechanism is instead: Mismatched transceiver and fiber specifications prevent a valid optical link. Applying the other repair would not directly resolve this fault.

C:

This action is better suited to a separate Given a scenario, install physical hardware incident: An analytics rack's connected servers draw 6.8 kW, while the only installed PDU is rated for 5 kW continuous load. That case involves: The rack demand exceeds its available safe power capacity. Here the observed mechanism is instead: Mismatched transceiver and fiber specifications prevent a valid optical link. Applying the other repair would not directly resolve this fault.

D:

This action is better suited to a separate Given a scenario, install physical hardware incident: A new blade chassis is connected to the network before its enclosure-level shared power and cooling redundancy has been configured. That case involves: Shared chassis infrastructure creates failure domains beyond individual blades. Here the observed mechanism is instead: Mismatched transceiver and fiber specifications prevent a valid optical link. Applying the other repair would not directly resolve this fault.

Question 22

A server operations team encounters the following situation: Technicians install an active 10GbE optical link using a multimode transceiver at one end and a single-mode optic at the other. After making the corrective change, which result best demonstrates that this particular problem is resolved?

  1. Optical link testing passes without improvised adapters.
  2. A technician accesses each console without unplugging production connections.
  3. The link negotiates reliably and shows acceptable optical diagnostics and error counters.
  4. POST and hardware inventory recognize the approved GPU after installation.

Explanation

Correct Answer

C:

This is incident-specific acceptance evidence: The link negotiates reliably and shows acceptable optical diagnostics and error counters. It verifies the action replace the incompatible optical module or cable with a matched supported pair. The failure under test was: Mismatched transceiver and fiber specifications prevent a valid optical link.

Incorrect Answers

A:

This observation tests an unrelated Given a scenario, install physical hardware case: A mixed-fiber patch panel uses LC duplex ports but the ordered switch transceivers expect an unrelated connector type. It may be true while the current failure persists; the decisive current cause is: Mismatched transceiver and fiber specifications prevent a valid optical link.

B:

This observation tests an unrelated Given a scenario, install physical hardware case: A new remote rack has a KVM console accessible only by disconnecting active production monitor cables. It may be true while the current failure persists; the decisive current cause is: Mismatched transceiver and fiber specifications prevent a valid optical link.

D:

This observation tests an unrelated Given a scenario, install physical hardware case: A rack-mount GPU server requires a PCIe slot layout unsupported by the selected motherboard revision, although its CPU count is adequate. It may be true while the current failure persists; the decisive current cause is: Mismatched transceiver and fiber specifications prevent a valid optical link.

Question 23

A server operations team encounters the following situation: Technicians install an active 10GbE optical link using a multimode transceiver at one end and a single-mode optic at the other. Which underlying cause most specifically explains the observed symptoms?

  1. Recirculation through unfilled gaps undermines the hot-aisle and cold-aisle arrangement.
  2. Shared chassis infrastructure creates failure domains beyond individual blades.
  3. The proposed physical expansion count exceeds chassis slot capacity.
  4. Mismatched transceiver and fiber specifications prevent a valid optical link.

Explanation

Correct Answer

D:

This root-cause explanation directly accounts for the reported condition: Technicians install an active 10GbE optical link using a multimode transceiver at one end and a single-mode optic at the other. The corrective step is: Replace the incompatible optical module or cable with a matched supported pair. The verifying outcome is: The link negotiates reliably and shows acceptable optical diagnostics and error counters.

Incorrect Answers

A:

This alternative cause would explain a different case: A 42U rack is filled with servers without any blanking panels, and inlet temperatures rise despite adequate room cooling. It does not explain the actual incident's evidence. The present cause is: Mismatched transceiver and fiber specifications prevent a valid optical link.

B:

This alternative cause would explain a different case: A new blade chassis is connected to the network before its enclosure-level shared power and cooling redundancy has been configured. It does not explain the actual incident's evidence. The present cause is: Mismatched transceiver and fiber specifications prevent a valid optical link.

C:

This alternative cause would explain a different case: An expansion server needs four network ports, but the small-form chassis lacks enough PCIe slots for the specified add-in NICs. It does not explain the actual incident's evidence. The present cause is: Mismatched transceiver and fiber specifications prevent a valid optical link.

Question 24

A server operations team encounters the following situation: Technicians install an active 10GbE optical link using a multimode transceiver at one end and a single-mode optic at the other. Which sustained operational control best reduces the likelihood of this same issue recurring?

  1. Verify wavelength, media type and connector specifications for each fiber run.
  2. Require tested cable category and length documentation for high-speed ports.
  3. Inventory panel termination and pluggable interfaces before purchasing.
  4. Map local console serviceability in rack layout planning.

Explanation

Correct Answer

A:

This control targets the underlying recurrence risk: Mismatched transceiver and fiber specifications prevent a valid optical link. It builds validation into the affected workflow and supports the expected recovery result: The link negotiates reliably and shows acceptable optical diagnostics and error counters.

Incorrect Answers

B:

This control addresses a different scenario: Technicians use a consumer patch cable for a 10GbE run longer than its specified distance and see frequent cyclic redundancy errors. That event's root mechanism was the cabling channel does not meet electrical performance requirements at the selected rate. The described incident instead arises from: Mismatched transceiver and fiber specifications prevent a valid optical link.

C:

This control addresses a different scenario: A mixed-fiber patch panel uses LC duplex ports but the ordered switch transceivers expect an unrelated connector type. That event's root mechanism was physical connector compatibility is required in addition to optical signal compatibility. The described incident instead arises from: Mismatched transceiver and fiber specifications prevent a valid optical link.

D:

This control addresses a different scenario: A new remote rack has a KVM console accessible only by disconnecting active production monitor cables. That event's root mechanism was the chosen console access workflow is not operationally maintainable. The described incident instead arises from: Mismatched transceiver and fiber specifications prevent a valid optical link.

Question 25

A server operations team encounters the following situation: A new 10GbE NIC is fitted with a 1GbE-only SFP module, and a storage transfer cannot reach its specified link rate. Given the stated symptoms and constraints, which corrective action is the best next step?

  1. Reinstall cabling certified for the negotiated speed and measured channel length.
  2. Replan rack space and obtain a compatible enclosure location before delivery.
  3. Select a supported SFP+ optic or DAC and verify the NIC and switch capability.
  4. Select approved LC-compatible patch leads or the correct transceiver for the installed panel.

Explanation

Correct Answer

C:

The preferred corrective action directly addresses the incident: A new 10GbE NIC is fitted with a 1GbE-only SFP module, and a storage transfer cannot reach its specified link rate. The fault mechanism is the installed pluggable is not capable of the intended link speed. Expected confirmation is: The negotiated rate reaches 10GbE with no persistent physical errors.

Incorrect Answers

A:

This action is better suited to a separate Given a scenario, install physical hardware incident: Technicians use a consumer patch cable for a 10GbE run longer than its specified distance and see frequent cyclic redundancy errors. That case involves: The cabling channel does not meet electrical performance requirements at the selected rate. Here the observed mechanism is instead: The installed pluggable is not capable of the intended link speed. Applying the other repair would not directly resolve this fault.

B:

This action is better suited to a separate Given a scenario, install physical hardware incident: A hospital orders 4U blade enclosures but the existing 24U rack has only 2U contiguous free space near its reserved airflow corridor. That case involves: Available total units do not imply an enclosure can occupy fragmented rack space. Here the observed mechanism is instead: The installed pluggable is not capable of the intended link speed. Applying the other repair would not directly resolve this fault.

D:

This action is better suited to a separate Given a scenario, install physical hardware incident: A mixed-fiber patch panel uses LC duplex ports but the ordered switch transceivers expect an unrelated connector type. That case involves: Physical connector compatibility is required in addition to optical signal compatibility. Here the observed mechanism is instead: The installed pluggable is not capable of the intended link speed. Applying the other repair would not directly resolve this fault.

Question 26

A server operations team encounters the following situation: A new 10GbE NIC is fitted with a 1GbE-only SFP module, and a storage transfer cannot reach its specified link rate. After making the corrective change, which result best demonstrates that this particular problem is resolved?

  1. Thermal sensors remain inside limits under representative sustained processing.
  2. Disconnecting one switch leaves tested database access functional.
  3. A technician accesses each console without unplugging production connections.
  4. The negotiated rate reaches 10GbE with no persistent physical errors.

Explanation

Correct Answer

D:

This is incident-specific acceptance evidence: The negotiated rate reaches 10GbE with no persistent physical errors. It verifies the action select a supported SFP+ optic or DAC and verify the NIC and switch capability. The failure under test was: The installed pluggable is not capable of the intended link speed.

Incorrect Answers

A:

This observation tests an unrelated Given a scenario, install physical hardware case: A compact server cabinet is placed against a wall that blocks its rear exhaust, and upper nodes throttle during batch workloads. It may be true while the current failure persists; the decisive current cause is: The installed pluggable is not capable of the intended link speed.

B:

This observation tests an unrelated Given a scenario, install physical hardware case: Two database hosts share a single switch uplink despite a design requiring link resilience across switch failures. It may be true while the current failure persists; the decisive current cause is: The installed pluggable is not capable of the intended link speed.

C:

This observation tests an unrelated Given a scenario, install physical hardware case: A new remote rack has a KVM console accessible only by disconnecting active production monitor cables. It may be true while the current failure persists; the decisive current cause is: The installed pluggable is not capable of the intended link speed.

Question 27

A server operations team encounters the following situation: A new 10GbE NIC is fitted with a 1GbE-only SFP module, and a storage transfer cannot reach its specified link rate. Which underlying cause most specifically explains the observed symptoms?

  1. The installed pluggable is not capable of the intended link speed.
  2. The installation prevents warm exhaust from leaving the cabinet.
  3. Battery runtime depends on actual load, not just the UPS nameplate apparent power.
  4. Two supplies share one upstream electrical failure domain.

Explanation

Correct Answer

A:

This root-cause explanation directly accounts for the reported condition: A new 10GbE NIC is fitted with a 1GbE-only SFP module, and a storage transfer cannot reach its specified link rate. The corrective step is: Select a supported SFP+ optic or DAC and verify the NIC and switch capability. The verifying outcome is: The negotiated rate reaches 10GbE with no persistent physical errors.

Incorrect Answers

B:

This alternative cause would explain a different case: A compact server cabinet is placed against a wall that blocks its rear exhaust, and upper nodes throttle during batch workloads. It does not explain the actual incident's evidence. The present cause is: The installed pluggable is not capable of the intended link speed.

C:

This alternative cause would explain a different case: One site's new rack consumes more power than two UPS battery strings can support for the required graceful shutdown window. It does not explain the actual incident's evidence. The present cause is: The installed pluggable is not capable of the intended link speed.

D:

This alternative cause would explain a different case: A branch installs both redundant PSU cords into the same power strip even though two independent protected circuits are available. It does not explain the actual incident's evidence. The present cause is: The installed pluggable is not capable of the intended link speed.

Question 28

A server operations team encounters the following situation: A new 10GbE NIC is fitted with a 1GbE-only SFP module, and a storage transfer cannot reach its specified link rate. Which sustained operational control best reduces the likelihood of this same issue recurring?

  1. Validate physical rack elevations against each incoming chassis dimension.
  2. Keep optical part numbers tied to port speed requirements.
  3. Record rack-post type and chassis rail compatibility in procurement checks.
  4. Verify wavelength, media type and connector specifications for each fiber run.

Explanation

Correct Answer

B:

This control targets the underlying recurrence risk: The installed pluggable is not capable of the intended link speed. It builds validation into the affected workflow and supports the expected recovery result: The negotiated rate reaches 10GbE with no persistent physical errors.

Incorrect Answers

A:

This control addresses a different scenario: A hospital orders 4U blade enclosures but the existing 24U rack has only 2U contiguous free space near its reserved airflow corridor. That event's root mechanism was available total units do not imply an enclosure can occupy fragmented rack space. The described incident instead arises from: The installed pluggable is not capable of the intended link speed.

C:

This control addresses a different scenario: A new 2U compute node ships with universal sliding rails that do not match the data center's square-hole posts. That event's root mechanism was an incompatible mounting rail cannot provide a verified secure server installation. The described incident instead arises from: The installed pluggable is not capable of the intended link speed.

D:

This control addresses a different scenario: Technicians install an active 10GbE optical link using a multimode transceiver at one end and a single-mode optic at the other. That event's root mechanism was mismatched transceiver and fiber specifications prevent a valid optical link. The described incident instead arises from: The installed pluggable is not capable of the intended link speed.

Question 29

A server operations team encounters the following situation: Two database hosts share a single switch uplink despite a design requiring link resilience across switch failures. Given the stated symptoms and constraints, which corrective action is the best next step?

  1. Relocate dense equipment low and verify rack anchoring and floor-load ratings.
  2. Choose a supported onboard or compatible multiport NIC configuration before ordering.
  3. Fit a compatible rack KVM or approved out-of-band console design for all managed servers.
  4. Provide redundant NIC paths to independent switches with a compatible teaming design.

Explanation

Correct Answer

D:

The preferred corrective action directly addresses the incident: Two database hosts share a single switch uplink despite a design requiring link resilience across switch failures. The fault mechanism is an additional cable to the same switch would preserve a common point of failure. Expected confirmation is: Disconnecting one switch leaves tested database access functional.

Incorrect Answers

A:

This action is better suited to a separate Given a scenario, install physical hardware incident: A heavy UPS is planned above lightly loaded servers in a rack that maintenance technicians frequently roll across a raised floor. That case involves: High center of gravity and unverified floor loading create a personnel and stability hazard. Here the observed mechanism is instead: An additional cable to the same switch would preserve a common point of failure. Applying the other repair would not directly resolve this fault.

B:

This action is better suited to a separate Given a scenario, install physical hardware incident: An expansion server needs four network ports, but the small-form chassis lacks enough PCIe slots for the specified add-in NICs. That case involves: The proposed physical expansion count exceeds chassis slot capacity. Here the observed mechanism is instead: An additional cable to the same switch would preserve a common point of failure. Applying the other repair would not directly resolve this fault.

C:

This action is better suited to a separate Given a scenario, install physical hardware incident: A new remote rack has a KVM console accessible only by disconnecting active production monitor cables. That case involves: The chosen console access workflow is not operationally maintainable. Here the observed mechanism is instead: An additional cable to the same switch would preserve a common point of failure. Applying the other repair would not directly resolve this fault.

Question 30

A server operations team encounters the following situation: Two database hosts share a single switch uplink despite a design requiring link resilience across switch failures. After making the corrective change, which result best demonstrates that this particular problem is resolved?

  1. Disconnecting one switch leaves tested database access functional.
  2. The revised rack passes load and tip-risk inspection before energizing.
  3. A load test demonstrates the declared time to orderly shutdown.
  4. The link negotiates reliably and shows acceptable optical diagnostics and error counters.

Explanation

Correct Answer

A:

This is incident-specific acceptance evidence: Disconnecting one switch leaves tested database access functional. It verifies the action provide redundant NIC paths to independent switches with a compatible teaming design. The failure under test was: An additional cable to the same switch would preserve a common point of failure.

Incorrect Answers

B:

This observation tests an unrelated Given a scenario, install physical hardware case: A heavy UPS is planned above lightly loaded servers in a rack that maintenance technicians frequently roll across a raised floor. It may be true while the current failure persists; the decisive current cause is: An additional cable to the same switch would preserve a common point of failure.

C:

This observation tests an unrelated Given a scenario, install physical hardware case: One site's new rack consumes more power than two UPS battery strings can support for the required graceful shutdown window. It may be true while the current failure persists; the decisive current cause is: An additional cable to the same switch would preserve a common point of failure.

D:

This observation tests an unrelated Given a scenario, install physical hardware case: Technicians install an active 10GbE optical link using a multimode transceiver at one end and a single-mode optic at the other. It may be true while the current failure persists; the decisive current cause is: An additional cable to the same switch would preserve a common point of failure.