McAfee-Secured Website

Exam Bundle

Exam Code: SK0-005

Exam Name CompTIA Server+ Certification Exam

Certification Provider: CompTIA

Corresponding Certification: CompTIA Server+

CompTIA SK0-005 Bundle $44.99

100% CompTIA SK0-005 Guaranteed Success With Testking Training Materials

Get Real SK0-005 Exam Questions & Expert Verified Answers as Experienced on the Real Exam!

  • Questions & Answers

    SK0-005 Questions & Answers

    617 Questions & Answers

    The ultimate exam preparation tool, Questions & Answers mirrors the actual SK0-005 exam while allowing you to hone and measure every aspect of your test-taking ability.

  • SK0-005 Video Course

    SK0-005 Video Course

    139 Video Lectures

    SK0-005 Video Course is developed by CompTIA Professionals to help you pass the SK0-005 exam.

    Description

    This course will improve your knowledge and skills required to pass CompTIA Server+ Certification Exam exam.
  • Study Guide

    SK0-005 Study Guide

    533 PDF Pages

    Developed by industry experts, this 533-page guide spells out in painstaking detail all of the information you need to ace SK0-005 exam.

CompTIA Server+ Certification Exam (SK0-005) Practice Tests

Satisfaction Guaranteed

Money Back Guarantee

Testking provides hassle-free money back guarantee with our products. That is because we have 100% trust in the abilities of our professional and experience product team, and our record is a proof of that.

99.6% PASS RATE
Total Cost: $194.97
Bundle Price: $149.98

Purchase Individually

  • Questions & Answers

    Questions & Answers

    617 Questions

    $124.99
  • SK0-005 Video Course

    Video Course

    139 Video Lectures

    $39.99
  • Study Guide

    Study Guide

    533 PDF Pages

    $29.99

CompTIA SK0-005 Practice Test 2

Question 10

A server operations team encounters the following situation: A new 2U compute node ships with universal sliding rails that do not match the data center's square-hole posts. After making the corrective change, which result best demonstrates that this particular problem is resolved?

  1. The revised rack passes load and tip-risk inspection before energizing.
  2. Cable certification and port error counters meet the link acceptance criteria.
  3. POST and hardware inventory recognize the approved GPU after installation.
  4. The fully supported chassis slides safely without improvised fasteners.

Explanation

Correct Answer

D:

This is incident-specific acceptance evidence: The fully supported chassis slides safely without improvised fasteners. It verifies the action obtain approved rack rail kits and test attachment before installing the chassis. The failure under test was: An incompatible mounting rail cannot provide a verified secure server installation.

Incorrect Answers

A:

This observation tests an unrelated Given a scenario, install physical hardware case: A heavy UPS is planned above lightly loaded servers in a rack that maintenance technicians frequently roll across a raised floor. It may be true while the current failure persists; the decisive current cause is: An incompatible mounting rail cannot provide a verified secure server installation.

B:

This observation tests an unrelated Given a scenario, install physical hardware case: Technicians use a consumer patch cable for a 10GbE run longer than its specified distance and see frequent cyclic redundancy errors. It may be true while the current failure persists; the decisive current cause is: An incompatible mounting rail cannot provide a verified secure server installation.

C:

This observation tests an unrelated Given a scenario, install physical hardware case: A rack-mount GPU server requires a PCIe slot layout unsupported by the selected motherboard revision, although its CPU count is adequate. It may be true while the current failure persists; the decisive current cause is: An incompatible mounting rail cannot provide a verified secure server installation.

Question 11

A server operations team encounters the following situation: A new 2U compute node ships with universal sliding rails that do not match the data center's square-hole posts. Which underlying cause most specifically explains the observed symptoms?

  1. An incompatible mounting rail cannot provide a verified secure server installation.
  2. Processor capacity does not establish PCIe mechanical and electrical compatibility.
  3. Two supplies share one upstream electrical failure domain.
  4. Physical connector compatibility is required in addition to optical signal compatibility.

Explanation

Correct Answer

A:

This root-cause explanation directly accounts for the reported condition: A new 2U compute node ships with universal sliding rails that do not match the data center's square-hole posts. The corrective step is: Obtain approved rack rail kits and test attachment before installing the chassis. The verifying outcome is: The fully supported chassis slides safely without improvised fasteners.

Incorrect Answers

B:

This alternative cause would explain a different case: A rack-mount GPU server requires a PCIe slot layout unsupported by the selected motherboard revision, although its CPU count is adequate. It does not explain the actual incident's evidence. The present cause is: An incompatible mounting rail cannot provide a verified secure server installation.

C:

This alternative cause would explain a different case: A branch installs both redundant PSU cords into the same power strip even though two independent protected circuits are available. It does not explain the actual incident's evidence. The present cause is: An incompatible mounting rail cannot provide a verified secure server installation.

D:

This alternative cause would explain a different case: A mixed-fiber patch panel uses LC duplex ports but the ordered switch transceivers expect an unrelated connector type. It does not explain the actual incident's evidence. The present cause is: An incompatible mounting rail cannot provide a verified secure server installation.

Question 12

A server operations team encounters the following situation: A new 2U compute node ships with universal sliding rails that do not match the data center's square-hole posts. Which sustained operational control best reduces the likelihood of this same issue recurring?

  1. Check front and rear clearance against manufacturer installation guidance.
  2. Record rack-post type and chassis rail compatibility in procurement checks.
  3. Validate physical rack elevations against each incoming chassis dimension.
  4. Document enclosure-level fault tests as part of blade installation.

Explanation

Correct Answer

B:

This control targets the underlying recurrence risk: An incompatible mounting rail cannot provide a verified secure server installation. It builds validation into the affected workflow and supports the expected recovery result: The fully supported chassis slides safely without improvised fasteners.

Incorrect Answers

A:

This control addresses a different scenario: A compact server cabinet is placed against a wall that blocks its rear exhaust, and upper nodes throttle during batch workloads. That event's root mechanism was the installation prevents warm exhaust from leaving the cabinet. The described incident instead arises from: An incompatible mounting rail cannot provide a verified secure server installation.

C:

This control addresses a different scenario: A hospital orders 4U blade enclosures but the existing 24U rack has only 2U contiguous free space near its reserved airflow corridor. That event's root mechanism was available total units do not imply an enclosure can occupy fragmented rack space. The described incident instead arises from: An incompatible mounting rail cannot provide a verified secure server installation.

D:

This control addresses a different scenario: A new blade chassis is connected to the network before its enclosure-level shared power and cooling redundancy has been configured. That event's root mechanism was shared chassis infrastructure creates failure domains beyond individual blades. The described incident instead arises from: An incompatible mounting rail cannot provide a verified secure server installation.

Question 13

A server operations team encounters the following situation: A branch installs both redundant PSU cords into the same power strip even though two independent protected circuits are available. Given the stated symptoms and constraints, which corrective action is the best next step?

  1. Reinstall cabling certified for the negotiated speed and measured channel length.
  2. Provide specified exhaust clearance or relocate the cabinet for correct airflow.
  3. Relocate dense equipment low and verify rack anchoring and floor-load ratings.
  4. Feed the PSUs from separate approved PDUs and electrical circuits.

Explanation

Correct Answer

D:

The preferred corrective action directly addresses the incident: A branch installs both redundant PSU cords into the same power strip even though two independent protected circuits are available. The fault mechanism is two supplies share one upstream electrical failure domain. Expected confirmation is: Unplugging either PDU leaves the server powered through the other feed.

Incorrect Answers

A:

This action is better suited to a separate Given a scenario, install physical hardware incident: Technicians use a consumer patch cable for a 10GbE run longer than its specified distance and see frequent cyclic redundancy errors. That case involves: The cabling channel does not meet electrical performance requirements at the selected rate. Here the observed mechanism is instead: Two supplies share one upstream electrical failure domain. Applying the other repair would not directly resolve this fault.

B:

This action is better suited to a separate Given a scenario, install physical hardware incident: A compact server cabinet is placed against a wall that blocks its rear exhaust, and upper nodes throttle during batch workloads. That case involves: The installation prevents warm exhaust from leaving the cabinet. Here the observed mechanism is instead: Two supplies share one upstream electrical failure domain. Applying the other repair would not directly resolve this fault.

C:

This action is better suited to a separate Given a scenario, install physical hardware incident: A heavy UPS is planned above lightly loaded servers in a rack that maintenance technicians frequently roll across a raised floor. That case involves: High center of gravity and unverified floor loading create a personnel and stability hazard. Here the observed mechanism is instead: Two supplies share one upstream electrical failure domain. Applying the other repair would not directly resolve this fault.

Question 14

A server operations team encounters the following situation: A branch installs both redundant PSU cords into the same power strip even though two independent protected circuits are available. After making the corrective change, which result best demonstrates that this particular problem is resolved?

  1. Unplugging either PDU leaves the server powered through the other feed.
  2. Optical link testing passes without improvised adapters.
  3. POST and hardware inventory recognize the approved GPU after installation.
  4. Inlet temperature falls under the same room supply-air conditions.

Explanation

Correct Answer

A:

This is incident-specific acceptance evidence: Unplugging either PDU leaves the server powered through the other feed. It verifies the action feed the PSUs from separate approved PDUs and electrical circuits. The failure under test was: Two supplies share one upstream electrical failure domain.

Incorrect Answers

B:

This observation tests an unrelated Given a scenario, install physical hardware case: A mixed-fiber patch panel uses LC duplex ports but the ordered switch transceivers expect an unrelated connector type. It may be true while the current failure persists; the decisive current cause is: Two supplies share one upstream electrical failure domain.

C:

This observation tests an unrelated Given a scenario, install physical hardware case: A rack-mount GPU server requires a PCIe slot layout unsupported by the selected motherboard revision, although its CPU count is adequate. It may be true while the current failure persists; the decisive current cause is: Two supplies share one upstream electrical failure domain.

D:

This observation tests an unrelated Given a scenario, install physical hardware case: A 42U rack is filled with servers without any blanking panels, and inlet temperatures rise despite adequate room cooling. It may be true while the current failure persists; the decisive current cause is: Two supplies share one upstream electrical failure domain.

Question 15

A server operations team encounters the following situation: A branch installs both redundant PSU cords into the same power strip even though two independent protected circuits are available. Which underlying cause most specifically explains the observed symptoms?

  1. Available total units do not imply an enclosure can occupy fragmented rack space.
  2. Two supplies share one upstream electrical failure domain.
  3. The chosen console access workflow is not operationally maintainable.
  4. Processor capacity does not establish PCIe mechanical and electrical compatibility.

Explanation

Correct Answer

B:

This root-cause explanation directly accounts for the reported condition: A branch installs both redundant PSU cords into the same power strip even though two independent protected circuits are available. The corrective step is: Feed the PSUs from separate approved PDUs and electrical circuits. The verifying outcome is: Unplugging either PDU leaves the server powered through the other feed.

Incorrect Answers

A:

This alternative cause would explain a different case: A hospital orders 4U blade enclosures but the existing 24U rack has only 2U contiguous free space near its reserved airflow corridor. It does not explain the actual incident's evidence. The present cause is: Two supplies share one upstream electrical failure domain.

C:

This alternative cause would explain a different case: A new remote rack has a KVM console accessible only by disconnecting active production monitor cables. It does not explain the actual incident's evidence. The present cause is: Two supplies share one upstream electrical failure domain.

D:

This alternative cause would explain a different case: A rack-mount GPU server requires a PCIe slot layout unsupported by the selected motherboard revision, although its CPU count is adequate. It does not explain the actual incident's evidence. The present cause is: Two supplies share one upstream electrical failure domain.

Question 16

A server operations team encounters the following situation: A branch installs both redundant PSU cords into the same power strip even though two independent protected circuits are available. Which sustained operational control best reduces the likelihood of this same issue recurring?

  1. Inventory panel termination and pluggable interfaces before purchasing.
  2. Document enclosure-level fault tests as part of blade installation.
  3. Include PDU-to-circuit tracing in redundant power acceptance.
  4. Validate physical rack elevations against each incoming chassis dimension.

Explanation

Correct Answer

C:

This control targets the underlying recurrence risk: Two supplies share one upstream electrical failure domain. It builds validation into the affected workflow and supports the expected recovery result: Unplugging either PDU leaves the server powered through the other feed.

Incorrect Answers

A:

This control addresses a different scenario: A mixed-fiber patch panel uses LC duplex ports but the ordered switch transceivers expect an unrelated connector type. That event's root mechanism was physical connector compatibility is required in addition to optical signal compatibility. The described incident instead arises from: Two supplies share one upstream electrical failure domain.

B:

This control addresses a different scenario: A new blade chassis is connected to the network before its enclosure-level shared power and cooling redundancy has been configured. That event's root mechanism was shared chassis infrastructure creates failure domains beyond individual blades. The described incident instead arises from: Two supplies share one upstream electrical failure domain.

D:

This control addresses a different scenario: A hospital orders 4U blade enclosures but the existing 24U rack has only 2U contiguous free space near its reserved airflow corridor. That event's root mechanism was available total units do not imply an enclosure can occupy fragmented rack space. The described incident instead arises from: Two supplies share one upstream electrical failure domain.

Question 17

A server operations team encounters the following situation: An analytics rack's connected servers draw 6.8 kW, while the only installed PDU is rated for 5 kW continuous load. Given the stated symptoms and constraints, which corrective action is the best next step?

  1. Recalculate power budget and provision sufficient rated redundant distribution before activation.
  2. Provide specified exhaust clearance or relocate the cabinet for correct airflow.
  3. Reinstall cabling certified for the negotiated speed and measured channel length.
  4. Provide redundant NIC paths to independent switches with a compatible teaming design.

Explanation

Correct Answer

A:

The preferred corrective action directly addresses the incident: An analytics rack's connected servers draw 6.8 kW, while the only installed PDU is rated for 5 kW continuous load. The fault mechanism is the rack demand exceeds its available safe power capacity. Expected confirmation is: Meter readings remain within rated continuous circuit and PDU limits under peak load.

Incorrect Answers

B:

This action is better suited to a separate Given a scenario, install physical hardware incident: A compact server cabinet is placed against a wall that blocks its rear exhaust, and upper nodes throttle during batch workloads. That case involves: The installation prevents warm exhaust from leaving the cabinet. Here the observed mechanism is instead: The rack demand exceeds its available safe power capacity. Applying the other repair would not directly resolve this fault.

C:

This action is better suited to a separate Given a scenario, install physical hardware incident: Technicians use a consumer patch cable for a 10GbE run longer than its specified distance and see frequent cyclic redundancy errors. That case involves: The cabling channel does not meet electrical performance requirements at the selected rate. Here the observed mechanism is instead: The rack demand exceeds its available safe power capacity. Applying the other repair would not directly resolve this fault.

D:

This action is better suited to a separate Given a scenario, install physical hardware incident: Two database hosts share a single switch uplink despite a design requiring link resilience across switch failures. That case involves: An additional cable to the same switch would preserve a common point of failure. Here the observed mechanism is instead: The rack demand exceeds its available safe power capacity. Applying the other repair would not directly resolve this fault.

Question 18

A server operations team encounters the following situation: An analytics rack's connected servers draw 6.8 kW, while the only installed PDU is rated for 5 kW continuous load. After making the corrective change, which result best demonstrates that this particular problem is resolved?

  1. The fully supported chassis slides safely without improvised fasteners.
  2. Meter readings remain within rated continuous circuit and PDU limits under peak load.
  3. The link negotiates reliably and shows acceptable optical diagnostics and error counters.
  4. Inlet temperature falls under the same room supply-air conditions.

Explanation

Correct Answer

B:

This is incident-specific acceptance evidence: Meter readings remain within rated continuous circuit and PDU limits under peak load. It verifies the action recalculate power budget and provision sufficient rated redundant distribution before activation. The failure under test was: The rack demand exceeds its available safe power capacity.

Incorrect Answers

A:

This observation tests an unrelated Given a scenario, install physical hardware case: A new 2U compute node ships with universal sliding rails that do not match the data center's square-hole posts. It may be true while the current failure persists; the decisive current cause is: The rack demand exceeds its available safe power capacity.

C:

This observation tests an unrelated Given a scenario, install physical hardware case: Technicians install an active 10GbE optical link using a multimode transceiver at one end and a single-mode optic at the other. It may be true while the current failure persists; the decisive current cause is: The rack demand exceeds its available safe power capacity.

D:

This observation tests an unrelated Given a scenario, install physical hardware case: A 42U rack is filled with servers without any blanking panels, and inlet temperatures rise despite adequate room cooling. It may be true while the current failure persists; the decisive current cause is: The rack demand exceeds its available safe power capacity.

Question 19

A server operations team encounters the following situation: An analytics rack's connected servers draw 6.8 kW, while the only installed PDU is rated for 5 kW continuous load. Which underlying cause most specifically explains the observed symptoms?

  1. Unsupported manual handling presents a preventable installation safety risk.
  2. Physical connector compatibility is required in addition to optical signal compatibility.
  3. The rack demand exceeds its available safe power capacity.
  4. Shared chassis infrastructure creates failure domains beyond individual blades.

Explanation

Correct Answer

C:

This root-cause explanation directly accounts for the reported condition: An analytics rack's connected servers draw 6.8 kW, while the only installed PDU is rated for 5 kW continuous load. The corrective step is: Recalculate power budget and provision sufficient rated redundant distribution before activation. The verifying outcome is: Meter readings remain within rated continuous circuit and PDU limits under peak load.

Incorrect Answers

A:

This alternative cause would explain a different case: An installation team plans to lift a populated 3U server alone into the top rails in violation of site safe-lift guidance. It does not explain the actual incident's evidence. The present cause is: The rack demand exceeds its available safe power capacity.

B:

This alternative cause would explain a different case: A mixed-fiber patch panel uses LC duplex ports but the ordered switch transceivers expect an unrelated connector type. It does not explain the actual incident's evidence. The present cause is: The rack demand exceeds its available safe power capacity.

D:

This alternative cause would explain a different case: A new blade chassis is connected to the network before its enclosure-level shared power and cooling redundancy has been configured. It does not explain the actual incident's evidence. The present cause is: The rack demand exceeds its available safe power capacity.

Question 20

A server operations team encounters the following situation: An analytics rack's connected servers draw 6.8 kW, while the only installed PDU is rated for 5 kW continuous load. Which sustained operational control best reduces the likelihood of this same issue recurring?

  1. Cross-check HCL expansion-slot and port counts before purchase.
  2. Trace each redundant network path end-to-end during commissioning.
  3. Include PDU-to-circuit tracing in redundant power acceptance.
  4. Approve measured electrical headroom before each capacity expansion.

Explanation

Correct Answer

D:

This control targets the underlying recurrence risk: The rack demand exceeds its available safe power capacity. It builds validation into the affected workflow and supports the expected recovery result: Meter readings remain within rated continuous circuit and PDU limits under peak load.

Incorrect Answers

A:

This control addresses a different scenario: An expansion server needs four network ports, but the small-form chassis lacks enough PCIe slots for the specified add-in NICs. That event's root mechanism was the proposed physical expansion count exceeds chassis slot capacity. The described incident instead arises from: The rack demand exceeds its available safe power capacity.

B:

This control addresses a different scenario: Two database hosts share a single switch uplink despite a design requiring link resilience across switch failures. That event's root mechanism was an additional cable to the same switch would preserve a common point of failure. The described incident instead arises from: The rack demand exceeds its available safe power capacity.

C:

This control addresses a different scenario: A branch installs both redundant PSU cords into the same power strip even though two independent protected circuits are available. That event's root mechanism was two supplies share one upstream electrical failure domain. The described incident instead arises from: The rack demand exceeds its available safe power capacity.