McAfee-Secured Website

Exam Bundle

Exam Code: SK0-005

Exam Name CompTIA Server+ Certification Exam

Certification Provider: CompTIA

Corresponding Certification: CompTIA Server+

CompTIA SK0-005 Bundle $44.99

100% CompTIA SK0-005 Guaranteed Success With Testking Training Materials

Get Real SK0-005 Exam Questions & Expert Verified Answers as Experienced on the Real Exam!

  • Questions & Answers

    SK0-005 Questions & Answers

    617 Questions & Answers

    The ultimate exam preparation tool, Questions & Answers mirrors the actual SK0-005 exam while allowing you to hone and measure every aspect of your test-taking ability.

  • SK0-005 Video Course

    SK0-005 Video Course

    139 Video Lectures

    SK0-005 Video Course is developed by CompTIA Professionals to help you pass the SK0-005 exam.

    Description

    This course will improve your knowledge and skills required to pass CompTIA Server+ Certification Exam exam.
  • Study Guide

    SK0-005 Study Guide

    533 PDF Pages

    Developed by industry experts, this 533-page guide spells out in painstaking detail all of the information you need to ace SK0-005 exam.

CompTIA Server+ Certification Exam (SK0-005) Practice Tests

Satisfaction Guaranteed

Money Back Guarantee

Testking provides hassle-free money back guarantee with our products. That is because we have 100% trust in the abilities of our professional and experience product team, and our record is a proof of that.

99.6% PASS RATE
Total Cost: $194.97
Bundle Price: $149.98

Purchase Individually

  • Questions & Answers

    Questions & Answers

    617 Questions

    $124.99
  • SK0-005 Video Course

    Video Course

    139 Video Lectures

    $39.99
  • Study Guide

    Study Guide

    533 PDF Pages

    $29.99

CompTIA SK0-005 Practice Test 18

Question 170

A server operations team encounters the following situation: A management network grants any guest laptop access to the server baseboard management controllers. After making the corrective change, which result best demonstrates that this particular problem is resolved?

  1. Controller firmware reports the approved version and retains restricted access.
  2. The drive is correctly seated and controller status remains healthy.
  3. The operator interacts with firmware screens before an operating system is available.
  4. Guest-subnet connection attempts fail while approved administrators retain access.

Explanation

Correct Answer

D:

This is incident-specific acceptance evidence: Guest-subnet connection attempts fail while approved administrators retain access. It verifies the action restrict out-of-band interfaces to a dedicated protected management path. The failure under test was: OOB controllers expose privileged functions independent of the server OS.

Incorrect Answers

A:

This observation tests an unrelated Given a scenario, perform server hardware maintenance case: An OOB controller firmware update is performed from a guest network without verifying package signatures or a recovery path. It may be true while the current failure persists; the decisive current cause is: OOB controllers expose privileged functions independent of the server OS.

B:

This observation tests an unrelated Given a scenario, perform server hardware maintenance case: A new server's hot-swap drive tray sticks because it is a different generation despite fitting the drive's physical dimensions. It may be true while the current failure persists; the decisive current cause is: OOB controllers expose privileged functions independent of the server OS.

C:

This observation tests an unrelated Given a scenario, perform server hardware maintenance case: A remote host's keyboard stops working during POST and the technician attempts an OS RDP session that cannot start before boot. It may be true while the current failure persists; the decisive current cause is: OOB controllers expose privileged functions independent of the server OS.

Question 171

A server operations team encounters the following situation: A management network grants any guest laptop access to the server baseboard management controllers. Which underlying cause most specifically explains the observed symptoms?

  1. OOB controllers expose privileged functions independent of the server OS.
  2. Hardware replacement requires both component compatibility and safe handling.
  3. Firmware maintenance crosses a highly privileged management security boundary.
  4. Not every expansion card supports removal under power.

Explanation

Correct Answer

A:

This root-cause explanation directly accounts for the reported condition: A management network grants any guest laptop access to the server baseboard management controllers. The corrective step is: Restrict out-of-band interfaces to a dedicated protected management path. The verifying outcome is: Guest-subnet connection attempts fail while approved administrators retain access.

Incorrect Answers

B:

This alternative cause would explain a different case: A maintenance worker attempts to hot-swap a fan while wearing no ESD protection and leaving cables across the service aisle. It does not explain the actual incident's evidence. The present cause is: OOB controllers expose privileged functions independent of the server OS.

C:

This alternative cause would explain a different case: An OOB controller firmware update is performed from a guest network without verifying package signatures or a recovery path. It does not explain the actual incident's evidence. The present cause is: OOB controllers expose privileged functions independent of the server OS.

D:

This alternative cause would explain a different case: An administrator replaces a running server's non-hot-pluggable PCIe card without powering down or checking service instructions. It does not explain the actual incident's evidence. The present cause is: OOB controllers expose privileged functions independent of the server OS.

Question 172

A server operations team encounters the following situation: A management network grants any guest laptop access to the server baseboard management controllers. Which sustained operational control best reduces the likelihood of this same issue recurring?

  1. Include firmware settings in virtualization preflight checks.
  2. Audit network segmentation and controller firmware before remote administration.
  3. Maintain slot maps and supported live-replacement procedures.
  4. Include preboot access in remote recovery design.

Explanation

Correct Answer

B:

This control targets the underlying recurrence risk: OOB controllers expose privileged functions independent of the server OS. It builds validation into the affected workflow and supports the expected recovery result: Guest-subnet connection attempts fail while approved administrators retain access.

Incorrect Answers

A:

This control addresses a different scenario: A production system requires BIOS virtualization extensions, but a hypervisor installer reports hardware virtualization disabled. That event's root mechanism was firmware configuration can disable CPU features that hardware physically supports. The described incident instead arises from: OOB controllers expose privileged functions independent of the server OS.

C:

This control addresses a different scenario: A failed redundant fan module is detected while the server is operating but the maintenance team cannot identify which bay may be swapped live. That event's root mechanism was incorrect fan removal can eliminate remaining cooling headroom. The described incident instead arises from: OOB controllers expose privileged functions independent of the server OS.

D:

This control addresses a different scenario: A remote host's keyboard stops working during POST and the technician attempts an OS RDP session that cannot start before boot. That event's root mechanism was oS remote control cannot replace preboot console access. The described incident instead arises from: OOB controllers expose privileged functions independent of the server OS.

Question 173

A server operations team encounters the following situation: A failed redundant PSU is replaced with a different wattage part that is not supported by the server's chassis model. Given the stated symptoms and constraints, which corrective action is the best next step?

  1. Follow vendor update prerequisites and preserve recoverable configuration before flashing.
  2. Use chassis LEDs and service manual to replace only the designated hot-swap fan.
  3. Enable the approved CPU virtualization feature in UEFI after confirming hardware capability.
  4. Select the manufacturer-compatible replacement and preserve the second healthy feed.

Explanation

Correct Answer

D:

The preferred corrective action directly addresses the incident: A failed redundant PSU is replaced with a different wattage part that is not supported by the server's chassis model. The fault mechanism is matching connector shape does not establish PSU electrical or firmware support. Expected confirmation is: Both PSU bays report supported redundancy after the change.

Incorrect Answers

A:

This action is better suited to a separate Given a scenario, perform server hardware maintenance incident: A technician schedules a BIOS update without checking the vendor's supported firmware sequence and loses a device configuration after reboot. That case involves: Firmware changes can modify hardware initialization and settings. Here the observed mechanism is instead: Matching connector shape does not establish PSU electrical or firmware support. Applying the other repair would not directly resolve this fault.

B:

This action is better suited to a separate Given a scenario, perform server hardware maintenance incident: A failed redundant fan module is detected while the server is operating but the maintenance team cannot identify which bay may be swapped live. That case involves: Incorrect fan removal can eliminate remaining cooling headroom. Here the observed mechanism is instead: Matching connector shape does not establish PSU electrical or firmware support. Applying the other repair would not directly resolve this fault.

C:

This action is better suited to a separate Given a scenario, perform server hardware maintenance incident: A production system requires BIOS virtualization extensions, but a hypervisor installer reports hardware virtualization disabled. That case involves: Firmware configuration can disable CPU features that hardware physically supports. Here the observed mechanism is instead: Matching connector shape does not establish PSU electrical or firmware support. Applying the other repair would not directly resolve this fault.

Question 174

A server operations team encounters the following situation: A failed redundant PSU is replaced with a different wattage part that is not supported by the server's chassis model. After making the corrective change, which result best demonstrates that this particular problem is resolved?

  1. Both PSU bays report supported redundancy after the change.
  2. Guest-subnet connection attempts fail while approved administrators retain access.
  3. Hypervisor validation detects virtualization extensions and the host passes compatibility checks.
  4. A controlled restart preserves or safely migrates the affected service.

Explanation

Correct Answer

A:

This is incident-specific acceptance evidence: Both PSU bays report supported redundancy after the change. It verifies the action select the manufacturer-compatible replacement and preserve the second healthy feed. The failure under test was: Matching connector shape does not establish PSU electrical or firmware support.

Incorrect Answers

B:

This observation tests an unrelated Given a scenario, perform server hardware maintenance case: A management network grants any guest laptop access to the server baseboard management controllers. It may be true while the current failure persists; the decisive current cause is: Matching connector shape does not establish PSU electrical or firmware support.

C:

This observation tests an unrelated Given a scenario, perform server hardware maintenance case: A production system requires BIOS virtualization extensions, but a hypervisor installer reports hardware virtualization disabled. It may be true while the current failure persists; the decisive current cause is: Matching connector shape does not establish PSU electrical or firmware support.

D:

This observation tests an unrelated Given a scenario, perform server hardware maintenance case: A technician notices that a server is not reachable in-band and powers it off remotely without checking active cluster roles. It may be true while the current failure persists; the decisive current cause is: Matching connector shape does not establish PSU electrical or firmware support.

Question 175

A server operations team encounters the following situation: A failed redundant PSU is replaced with a different wattage part that is not supported by the server's chassis model. Which underlying cause most specifically explains the observed symptoms?

  1. Firmware changes can modify hardware initialization and settings.
  2. Matching connector shape does not establish PSU electrical or firmware support.
  3. Firmware boot device priority differs from the intended operating system configuration.
  4. Incorrect fan removal can eliminate remaining cooling headroom.

Explanation

Correct Answer

B:

This root-cause explanation directly accounts for the reported condition: A failed redundant PSU is replaced with a different wattage part that is not supported by the server's chassis model. The corrective step is: Select the manufacturer-compatible replacement and preserve the second healthy feed. The verifying outcome is: Both PSU bays report supported redundancy after the change.

Incorrect Answers

A:

This alternative cause would explain a different case: A technician schedules a BIOS update without checking the vendor's supported firmware sequence and loses a device configuration after reboot. It does not explain the actual incident's evidence. The present cause is: Matching connector shape does not establish PSU electrical or firmware support.

C:

This alternative cause would explain a different case: A rack server unexpectedly boots from removable media after its UEFI boot order was changed during a repair. It does not explain the actual incident's evidence. The present cause is: Matching connector shape does not establish PSU electrical or firmware support.

D:

This alternative cause would explain a different case: A failed redundant fan module is detected while the server is operating but the maintenance team cannot identify which bay may be swapped live. It does not explain the actual incident's evidence. The present cause is: Matching connector shape does not establish PSU electrical or firmware support.

Question 176

A server operations team encounters the following situation: A failed redundant PSU is replaced with a different wattage part that is not supported by the server's chassis model. Which sustained operational control best reduces the likelihood of this same issue recurring?

  1. Require signed update and management-network checks before controller flashing.
  2. Label hardware as hot-swappable only when its platform actually supports it.
  3. Keep model-specific hot-spare compatibility records.
  4. Tie replacement carriers to chassis generation and part number.

Explanation

Correct Answer

C:

This control targets the underlying recurrence risk: Matching connector shape does not establish PSU electrical or firmware support. It builds validation into the affected workflow and supports the expected recovery result: Both PSU bays report supported redundancy after the change.

Incorrect Answers

A:

This control addresses a different scenario: An OOB controller firmware update is performed from a guest network without verifying package signatures or a recovery path. That event's root mechanism was firmware maintenance crosses a highly privileged management security boundary. The described incident instead arises from: Matching connector shape does not establish PSU electrical or firmware support.

B:

This control addresses a different scenario: An administrator replaces a running server's non-hot-pluggable PCIe card without powering down or checking service instructions. That event's root mechanism was not every expansion card supports removal under power. The described incident instead arises from: Matching connector shape does not establish PSU electrical or firmware support.

D:

This control addresses a different scenario: A new server's hot-swap drive tray sticks because it is a different generation despite fitting the drive's physical dimensions. That event's root mechanism was physical media size does not guarantee tray and backplane alignment. The described incident instead arises from: Matching connector shape does not establish PSU electrical or firmware support.

Question 177

A server operations team encounters the following situation: A server resets its clock and firmware settings on every complete power loss, while OS time synchronization works temporarily. Given the stated symptoms and constraints, which corrective action is the best next step?

  1. Replace the approved CMOS battery and verify BIOS/UEFI settings after a cold start.
  2. Use approved out-of-band remote console to inspect boot state and logs.
  3. Obtain the correct supported carrier and use the vendor's insertion procedure.
  4. Restore the approved UEFI boot priority and restrict external boot methods.

Explanation

Correct Answer

A:

The preferred corrective action directly addresses the incident: A server resets its clock and firmware settings on every complete power loss, while OS time synchronization works temporarily. The fault mechanism is a failing RTC battery loses persistent platform settings between power cycles. Expected confirmation is: Boot-time firmware clock and settings remain stable after unplugging power.

Incorrect Answers

B:

This action is better suited to a separate Given a scenario, perform server hardware maintenance incident: An off-site branch loses its primary OS interface, but the server has a dedicated management controller connected to a separate reachable network. That case involves: In-band remote desktop depends on the failed operating system interface. Here the observed mechanism is instead: A failing RTC battery loses persistent platform settings between power cycles. Applying the other repair would not directly resolve this fault.

C:

This action is better suited to a separate Given a scenario, perform server hardware maintenance incident: A new server's hot-swap drive tray sticks because it is a different generation despite fitting the drive's physical dimensions. That case involves: Physical media size does not guarantee tray and backplane alignment. Here the observed mechanism is instead: A failing RTC battery loses persistent platform settings between power cycles. Applying the other repair would not directly resolve this fault.

D:

This action is better suited to a separate Given a scenario, perform server hardware maintenance incident: A rack server unexpectedly boots from removable media after its UEFI boot order was changed during a repair. That case involves: Firmware boot device priority differs from the intended operating system configuration. Here the observed mechanism is instead: A failing RTC battery loses persistent platform settings between power cycles. Applying the other repair would not directly resolve this fault.

Question 178

A server operations team encounters the following situation: A server resets its clock and firmware settings on every complete power loss, while OS time synchronization works temporarily. After making the corrective change, which result best demonstrates that this particular problem is resolved?

  1. Cold boot loads the expected protected system disk rather than USB media.
  2. Boot-time firmware clock and settings remain stable after unplugging power.
  3. The replaced member matches the reported serial and the array rebuilds correctly.
  4. Hypervisor validation detects virtualization extensions and the host passes compatibility checks.

Explanation

Correct Answer

B:

This is incident-specific acceptance evidence: Boot-time firmware clock and settings remain stable after unplugging power. It verifies the action replace the approved CMOS battery and verify BIOS/UEFI settings after a cold start. The failure under test was: A failing RTC battery loses persistent platform settings between power cycles.

Incorrect Answers

A:

This observation tests an unrelated Given a scenario, perform server hardware maintenance case: A rack server unexpectedly boots from removable media after its UEFI boot order was changed during a repair. It may be true while the current failure persists; the decisive current cause is: A failing RTC battery loses persistent platform settings between power cycles.

C:

This observation tests an unrelated Given a scenario, perform server hardware maintenance case: A datacenter has several failed drives queued for replacement, but their labels have detached and technicians cannot map logical slots to physical cages. It may be true while the current failure persists; the decisive current cause is: A failing RTC battery loses persistent platform settings between power cycles.

D:

This observation tests an unrelated Given a scenario, perform server hardware maintenance case: A production system requires BIOS virtualization extensions, but a hypervisor installer reports hardware virtualization disabled. It may be true while the current failure persists; the decisive current cause is: A failing RTC battery loses persistent platform settings between power cycles.

Question 179

A server operations team encounters the following situation: A server resets its clock and firmware settings on every complete power loss, while OS time synchronization works temporarily. Which underlying cause most specifically explains the observed symptoms?

  1. Firmware maintenance crosses a highly privileged management security boundary.
  2. Firmware changes can modify hardware initialization and settings.
  3. A failing RTC battery loses persistent platform settings between power cycles.
  4. Hardware replacement requires both component compatibility and safe handling.

Explanation

Correct Answer

C:

This root-cause explanation directly accounts for the reported condition: A server resets its clock and firmware settings on every complete power loss, while OS time synchronization works temporarily. The corrective step is: Replace the approved CMOS battery and verify BIOS/UEFI settings after a cold start. The verifying outcome is: Boot-time firmware clock and settings remain stable after unplugging power.

Incorrect Answers

A:

This alternative cause would explain a different case: An OOB controller firmware update is performed from a guest network without verifying package signatures or a recovery path. It does not explain the actual incident's evidence. The present cause is: A failing RTC battery loses persistent platform settings between power cycles.

B:

This alternative cause would explain a different case: A technician schedules a BIOS update without checking the vendor's supported firmware sequence and loses a device configuration after reboot. It does not explain the actual incident's evidence. The present cause is: A failing RTC battery loses persistent platform settings between power cycles.

D:

This alternative cause would explain a different case: A maintenance worker attempts to hot-swap a fan while wearing no ESD protection and leaving cables across the service aisle. It does not explain the actual incident's evidence. The present cause is: A failing RTC battery loses persistent platform settings between power cycles.

Question 180

A server operations team encounters the following situation: A server resets its clock and firmware settings on every complete power loss, while OS time synchronization works temporarily. Which sustained operational control best reduces the likelihood of this same issue recurring?

  1. Include preboot access in remote recovery design.
  2. Test OOB availability independently of production VLANs.
  3. Maintain platform-specific firmware change and rollback plans.
  4. Monitor recurring firmware-reset events during preventative maintenance.

Explanation

Correct Answer

D:

This control targets the underlying recurrence risk: A failing RTC battery loses persistent platform settings between power cycles. It builds validation into the affected workflow and supports the expected recovery result: Boot-time firmware clock and settings remain stable after unplugging power.

Incorrect Answers

A:

This control addresses a different scenario: A remote host's keyboard stops working during POST and the technician attempts an OS RDP session that cannot start before boot. That event's root mechanism was oS remote control cannot replace preboot console access. The described incident instead arises from: A failing RTC battery loses persistent platform settings between power cycles.

B:

This control addresses a different scenario: An off-site branch loses its primary OS interface, but the server has a dedicated management controller connected to a separate reachable network. That event's root mechanism was in-band remote desktop depends on the failed operating system interface. The described incident instead arises from: A failing RTC battery loses persistent platform settings between power cycles.

C:

This control addresses a different scenario: A technician schedules a BIOS update without checking the vendor's supported firmware sequence and loses a device configuration after reboot. That event's root mechanism was firmware changes can modify hardware initialization and settings. The described incident instead arises from: A failing RTC battery loses persistent platform settings between power cycles.