McAfee-Secured Website

Exam Bundle

Exam Code: SK0-005

Exam Name CompTIA Server+ Certification Exam

Certification Provider: CompTIA

Corresponding Certification: CompTIA Server+

CompTIA SK0-005 Bundle $44.99

100% CompTIA SK0-005 Guaranteed Success With Testking Training Materials

Get Real SK0-005 Exam Questions & Expert Verified Answers as Experienced on the Real Exam!

  • Questions & Answers

    SK0-005 Questions & Answers

    617 Questions & Answers

    The ultimate exam preparation tool, Questions & Answers mirrors the actual SK0-005 exam while allowing you to hone and measure every aspect of your test-taking ability.

  • SK0-005 Video Course

    SK0-005 Video Course

    139 Video Lectures

    SK0-005 Video Course is developed by CompTIA Professionals to help you pass the SK0-005 exam.

    Description

    This course will improve your knowledge and skills required to pass CompTIA Server+ Certification Exam exam.
  • Study Guide

    SK0-005 Study Guide

    533 PDF Pages

    Developed by industry experts, this 533-page guide spells out in painstaking detail all of the information you need to ace SK0-005 exam.

CompTIA Server+ Certification Exam (SK0-005) Practice Tests

Satisfaction Guaranteed

Money Back Guarantee

Testking provides hassle-free money back guarantee with our products. That is because we have 100% trust in the abilities of our professional and experience product team, and our record is a proof of that.

99.6% PASS RATE
Total Cost: $194.97
Bundle Price: $149.98

Purchase Individually

  • Questions & Answers

    Questions & Answers

    617 Questions

    $124.99
  • SK0-005 Video Course

    Video Course

    139 Video Lectures

    $39.99
  • Study Guide

    Study Guide

    533 PDF Pages

    $29.99

CompTIA SK0-005 Practice Test 19

Question 180

A server operations team encounters the following situation: A server resets its clock and firmware settings on every complete power loss, while OS time synchronization works temporarily. Which sustained operational control best reduces the likelihood of this same issue recurring?

  1. Include preboot access in remote recovery design.
  2. Test OOB availability independently of production VLANs.
  3. Maintain platform-specific firmware change and rollback plans.
  4. Monitor recurring firmware-reset events during preventative maintenance.

Explanation

Correct Answer

D:

This control targets the underlying recurrence risk: A failing RTC battery loses persistent platform settings between power cycles. It builds validation into the affected workflow and supports the expected recovery result: Boot-time firmware clock and settings remain stable after unplugging power.

Incorrect Answers

A:

This control addresses a different scenario: A remote host's keyboard stops working during POST and the technician attempts an OS RDP session that cannot start before boot. That event's root mechanism was oS remote control cannot replace preboot console access. The described incident instead arises from: A failing RTC battery loses persistent platform settings between power cycles.

B:

This control addresses a different scenario: An off-site branch loses its primary OS interface, but the server has a dedicated management controller connected to a separate reachable network. That event's root mechanism was in-band remote desktop depends on the failed operating system interface. The described incident instead arises from: A failing RTC battery loses persistent platform settings between power cycles.

C:

This control addresses a different scenario: A technician schedules a BIOS update without checking the vendor's supported firmware sequence and loses a device configuration after reboot. That event's root mechanism was firmware changes can modify hardware initialization and settings. The described incident instead arises from: A failing RTC battery loses persistent platform settings between power cycles.

Question 181

A server operations team encounters the following situation: A remote host's keyboard stops working during POST and the technician attempts an OS RDP session that cannot start before boot. Given the stated symptoms and constraints, which corrective action is the best next step?

  1. Select the manufacturer-compatible replacement and preserve the second healthy feed.
  2. Use an IP KVM or approved serial-console path for preboot troubleshooting.
  3. Use approved out-of-band remote console to inspect boot state and logs.
  4. Identify failed bays using controller and chassis indicators before removing disks.

Explanation

Correct Answer

B:

The preferred corrective action directly addresses the incident: A remote host's keyboard stops working during POST and the technician attempts an OS RDP session that cannot start before boot. The fault mechanism is oS remote control cannot replace preboot console access. Expected confirmation is: The operator interacts with firmware screens before an operating system is available.

Incorrect Answers

A:

This action is better suited to a separate Given a scenario, perform server hardware maintenance incident: A failed redundant PSU is replaced with a different wattage part that is not supported by the server's chassis model. That case involves: Matching connector shape does not establish PSU electrical or firmware support. Here the observed mechanism is instead: OS remote control cannot replace preboot console access. Applying the other repair would not directly resolve this fault.

C:

This action is better suited to a separate Given a scenario, perform server hardware maintenance incident: An off-site branch loses its primary OS interface, but the server has a dedicated management controller connected to a separate reachable network. That case involves: In-band remote desktop depends on the failed operating system interface. Here the observed mechanism is instead: OS remote control cannot replace preboot console access. Applying the other repair would not directly resolve this fault.

D:

This action is better suited to a separate Given a scenario, perform server hardware maintenance incident: A datacenter has several failed drives queued for replacement, but their labels have detached and technicians cannot map logical slots to physical cages. That case involves: Blind removal risks taking a healthy member out of a degraded array. Here the observed mechanism is instead: OS remote control cannot replace preboot console access. Applying the other repair would not directly resolve this fault.

Question 182

A server operations team encounters the following situation: A remote host's keyboard stops working during POST and the technician attempts an OS RDP session that cannot start before boot. After making the corrective change, which result best demonstrates that this particular problem is resolved?

  1. Boot-time firmware clock and settings remain stable after unplugging power.
  2. Controller firmware reports the approved version and retains restricted access.
  3. The operator interacts with firmware screens before an operating system is available.
  4. A controlled restart preserves or safely migrates the affected service.

Explanation

Correct Answer

C:

This is incident-specific acceptance evidence: The operator interacts with firmware screens before an operating system is available. It verifies the action use an IP KVM or approved serial-console path for preboot troubleshooting. The failure under test was: OS remote control cannot replace preboot console access.

Incorrect Answers

A:

This observation tests an unrelated Given a scenario, perform server hardware maintenance case: A server resets its clock and firmware settings on every complete power loss, while OS time synchronization works temporarily. It may be true while the current failure persists; the decisive current cause is: OS remote control cannot replace preboot console access.

B:

This observation tests an unrelated Given a scenario, perform server hardware maintenance case: An OOB controller firmware update is performed from a guest network without verifying package signatures or a recovery path. It may be true while the current failure persists; the decisive current cause is: OS remote control cannot replace preboot console access.

D:

This observation tests an unrelated Given a scenario, perform server hardware maintenance case: A technician notices that a server is not reachable in-band and powers it off remotely without checking active cluster roles. It may be true while the current failure persists; the decisive current cause is: OS remote control cannot replace preboot console access.

Question 183

A server operations team encounters the following situation: A remote host's keyboard stops working during POST and the technician attempts an OS RDP session that cannot start before boot. Which underlying cause most specifically explains the observed symptoms?

  1. Matching connector shape does not establish PSU electrical or firmware support.
  2. Hardware replacement requires both component compatibility and safe handling.
  3. In-band remote desktop depends on the failed operating system interface.
  4. OS remote control cannot replace preboot console access.

Explanation

Correct Answer

D:

This root-cause explanation directly accounts for the reported condition: A remote host's keyboard stops working during POST and the technician attempts an OS RDP session that cannot start before boot. The corrective step is: Use an IP KVM or approved serial-console path for preboot troubleshooting. The verifying outcome is: The operator interacts with firmware screens before an operating system is available.

Incorrect Answers

A:

This alternative cause would explain a different case: A failed redundant PSU is replaced with a different wattage part that is not supported by the server's chassis model. It does not explain the actual incident's evidence. The present cause is: OS remote control cannot replace preboot console access.

B:

This alternative cause would explain a different case: A maintenance worker attempts to hot-swap a fan while wearing no ESD protection and leaving cables across the service aisle. It does not explain the actual incident's evidence. The present cause is: OS remote control cannot replace preboot console access.

C:

This alternative cause would explain a different case: An off-site branch loses its primary OS interface, but the server has a dedicated management controller connected to a separate reachable network. It does not explain the actual incident's evidence. The present cause is: OS remote control cannot replace preboot console access.

Question 184

A server operations team encounters the following situation: A remote host's keyboard stops working during POST and the technician attempts an OS RDP session that cannot start before boot. Which sustained operational control best reduces the likelihood of this same issue recurring?

  1. Include preboot access in remote recovery design.
  2. Audit network segmentation and controller firmware before remote administration.
  3. Capture and periodically audit approved platform boot settings.
  4. Require service-impact approval for remote power cycling.

Explanation

Correct Answer

A:

This control targets the underlying recurrence risk: OS remote control cannot replace preboot console access. It builds validation into the affected workflow and supports the expected recovery result: The operator interacts with firmware screens before an operating system is available.

Incorrect Answers

B:

This control addresses a different scenario: A management network grants any guest laptop access to the server baseboard management controllers. That event's root mechanism was oOB controllers expose privileged functions independent of the server OS. The described incident instead arises from: OS remote control cannot replace preboot console access.

C:

This control addresses a different scenario: A rack server unexpectedly boots from removable media after its UEFI boot order was changed during a repair. That event's root mechanism was firmware boot device priority differs from the intended operating system configuration. The described incident instead arises from: OS remote control cannot replace preboot console access.

D:

This control addresses a different scenario: A technician notices that a server is not reachable in-band and powers it off remotely without checking active cluster roles. That event's root mechanism was out-of-band power action bypasses normal workload shutdown safeguards. The described incident instead arises from: OS remote control cannot replace preboot console access.

Question 185

A server operations team encounters the following situation: A production system requires BIOS virtualization extensions, but a hypervisor installer reports hardware virtualization disabled. Given the stated symptoms and constraints, which corrective action is the best next step?

  1. Follow electrostatic and physical safety procedures before handling the approved module.
  2. Use chassis LEDs and service manual to replace only the designated hot-swap fan.
  3. Enable the approved CPU virtualization feature in UEFI after confirming hardware capability.
  4. Verify trusted firmware source and use isolated authorized management with documented recovery.

Explanation

Correct Answer

C:

The preferred corrective action directly addresses the incident: A production system requires BIOS virtualization extensions, but a hypervisor installer reports hardware virtualization disabled. The fault mechanism is firmware configuration can disable CPU features that hardware physically supports. Expected confirmation is: Hypervisor validation detects virtualization extensions and the host passes compatibility checks.

Incorrect Answers

A:

This action is better suited to a separate Given a scenario, perform server hardware maintenance incident: A maintenance worker attempts to hot-swap a fan while wearing no ESD protection and leaving cables across the service aisle. That case involves: Hardware replacement requires both component compatibility and safe handling. Here the observed mechanism is instead: Firmware configuration can disable CPU features that hardware physically supports. Applying the other repair would not directly resolve this fault.

B:

This action is better suited to a separate Given a scenario, perform server hardware maintenance incident: A failed redundant fan module is detected while the server is operating but the maintenance team cannot identify which bay may be swapped live. That case involves: Incorrect fan removal can eliminate remaining cooling headroom. Here the observed mechanism is instead: Firmware configuration can disable CPU features that hardware physically supports. Applying the other repair would not directly resolve this fault.

D:

This action is better suited to a separate Given a scenario, perform server hardware maintenance incident: An OOB controller firmware update is performed from a guest network without verifying package signatures or a recovery path. That case involves: Firmware maintenance crosses a highly privileged management security boundary. Here the observed mechanism is instead: Firmware configuration can disable CPU features that hardware physically supports. Applying the other repair would not directly resolve this fault.

Question 186

A server operations team encounters the following situation: A production system requires BIOS virtualization extensions, but a hypervisor installer reports hardware virtualization disabled. After making the corrective change, which result best demonstrates that this particular problem is resolved?

  1. The platform boots and firmware inventory matches the tested release.
  2. The drive is correctly seated and controller status remains healthy.
  3. POST enumerates the original storage controller and all expected logical drives.
  4. Hypervisor validation detects virtualization extensions and the host passes compatibility checks.

Explanation

Correct Answer

D:

This is incident-specific acceptance evidence: Hypervisor validation detects virtualization extensions and the host passes compatibility checks. It verifies the action enable the approved CPU virtualization feature in UEFI after confirming hardware capability. The failure under test was: Firmware configuration can disable CPU features that hardware physically supports.

Incorrect Answers

A:

This observation tests an unrelated Given a scenario, perform server hardware maintenance case: A technician schedules a BIOS update without checking the vendor's supported firmware sequence and loses a device configuration after reboot. It may be true while the current failure persists; the decisive current cause is: Firmware configuration can disable CPU features that hardware physically supports.

B:

This observation tests an unrelated Given a scenario, perform server hardware maintenance case: A new server's hot-swap drive tray sticks because it is a different generation despite fitting the drive's physical dimensions. It may be true while the current failure persists; the decisive current cause is: Firmware configuration can disable CPU features that hardware physically supports.

C:

This observation tests an unrelated Given a scenario, perform server hardware maintenance case: A BIOS update introduces an unsupported RAID controller option ROM, and storage devices disappear during POST. It may be true while the current failure persists; the decisive current cause is: Firmware configuration can disable CPU features that hardware physically supports.

Question 187

A server operations team encounters the following situation: A production system requires BIOS virtualization extensions, but a hypervisor installer reports hardware virtualization disabled. Which underlying cause most specifically explains the observed symptoms?

  1. Firmware configuration can disable CPU features that hardware physically supports.
  2. Firmware maintenance crosses a highly privileged management security boundary.
  3. Out-of-band power action bypasses normal workload shutdown safeguards.
  4. Not every expansion card supports removal under power.

Explanation

Correct Answer

A:

This root-cause explanation directly accounts for the reported condition: A production system requires BIOS virtualization extensions, but a hypervisor installer reports hardware virtualization disabled. The corrective step is: Enable the approved CPU virtualization feature in UEFI after confirming hardware capability. The verifying outcome is: Hypervisor validation detects virtualization extensions and the host passes compatibility checks.

Incorrect Answers

B:

This alternative cause would explain a different case: An OOB controller firmware update is performed from a guest network without verifying package signatures or a recovery path. It does not explain the actual incident's evidence. The present cause is: Firmware configuration can disable CPU features that hardware physically supports.

C:

This alternative cause would explain a different case: A technician notices that a server is not reachable in-band and powers it off remotely without checking active cluster roles. It does not explain the actual incident's evidence. The present cause is: Firmware configuration can disable CPU features that hardware physically supports.

D:

This alternative cause would explain a different case: An administrator replaces a running server's non-hot-pluggable PCIe card without powering down or checking service instructions. It does not explain the actual incident's evidence. The present cause is: Firmware configuration can disable CPU features that hardware physically supports.

Question 188

A server operations team encounters the following situation: A production system requires BIOS virtualization extensions, but a hypervisor installer reports hardware virtualization disabled. Which sustained operational control best reduces the likelihood of this same issue recurring?

  1. Capture and periodically audit approved platform boot settings.
  2. Include firmware settings in virtualization preflight checks.
  3. Label hardware as hot-swappable only when its platform actually supports it.
  4. Monitor recurring firmware-reset events during preventative maintenance.

Explanation

Correct Answer

B:

This control targets the underlying recurrence risk: Firmware configuration can disable CPU features that hardware physically supports. It builds validation into the affected workflow and supports the expected recovery result: Hypervisor validation detects virtualization extensions and the host passes compatibility checks.

Incorrect Answers

A:

This control addresses a different scenario: A rack server unexpectedly boots from removable media after its UEFI boot order was changed during a repair. That event's root mechanism was firmware boot device priority differs from the intended operating system configuration. The described incident instead arises from: Firmware configuration can disable CPU features that hardware physically supports.

C:

This control addresses a different scenario: An administrator replaces a running server's non-hot-pluggable PCIe card without powering down or checking service instructions. That event's root mechanism was not every expansion card supports removal under power. The described incident instead arises from: Firmware configuration can disable CPU features that hardware physically supports.

D:

This control addresses a different scenario: A server resets its clock and firmware settings on every complete power loss, while OS time synchronization works temporarily. That event's root mechanism was a failing RTC battery loses persistent platform settings between power cycles. The described incident instead arises from: Firmware configuration can disable CPU features that hardware physically supports.

Question 189

A server operations team encounters the following situation: A datacenter has several failed drives queued for replacement, but their labels have detached and technicians cannot map logical slots to physical cages. Given the stated symptoms and constraints, which corrective action is the best next step?

  1. Use an IP KVM or approved serial-console path for preboot troubleshooting.
  2. Follow vendor update prerequisites and preserve recoverable configuration before flashing.
  3. Use approved out-of-band remote console to inspect boot state and logs.
  4. Identify failed bays using controller and chassis indicators before removing disks.

Explanation

Correct Answer

D:

The preferred corrective action directly addresses the incident: A datacenter has several failed drives queued for replacement, but their labels have detached and technicians cannot map logical slots to physical cages. The fault mechanism is blind removal risks taking a healthy member out of a degraded array. Expected confirmation is: The replaced member matches the reported serial and the array rebuilds correctly.

Incorrect Answers

A:

This action is better suited to a separate Given a scenario, perform server hardware maintenance incident: A remote host's keyboard stops working during POST and the technician attempts an OS RDP session that cannot start before boot. That case involves: OS remote control cannot replace preboot console access. Here the observed mechanism is instead: Blind removal risks taking a healthy member out of a degraded array. Applying the other repair would not directly resolve this fault.

B:

This action is better suited to a separate Given a scenario, perform server hardware maintenance incident: A technician schedules a BIOS update without checking the vendor's supported firmware sequence and loses a device configuration after reboot. That case involves: Firmware changes can modify hardware initialization and settings. Here the observed mechanism is instead: Blind removal risks taking a healthy member out of a degraded array. Applying the other repair would not directly resolve this fault.

C:

This action is better suited to a separate Given a scenario, perform server hardware maintenance incident: An off-site branch loses its primary OS interface, but the server has a dedicated management controller connected to a separate reachable network. That case involves: In-band remote desktop depends on the failed operating system interface. Here the observed mechanism is instead: Blind removal risks taking a healthy member out of a degraded array. Applying the other repair would not directly resolve this fault.

Question 190

A server operations team encounters the following situation: A datacenter has several failed drives queued for replacement, but their labels have detached and technicians cannot map logical slots to physical cages. After making the corrective change, which result best demonstrates that this particular problem is resolved?

  1. The replaced member matches the reported serial and the array rebuilds correctly.
  2. POST enumerates the original storage controller and all expected logical drives.
  3. Controller firmware reports the approved version and retains restricted access.
  4. A controlled restart preserves or safely migrates the affected service.

Explanation

Correct Answer

A:

This is incident-specific acceptance evidence: The replaced member matches the reported serial and the array rebuilds correctly. It verifies the action identify failed bays using controller and chassis indicators before removing disks. The failure under test was: Blind removal risks taking a healthy member out of a degraded array.

Incorrect Answers

B:

This observation tests an unrelated Given a scenario, perform server hardware maintenance case: A BIOS update introduces an unsupported RAID controller option ROM, and storage devices disappear during POST. It may be true while the current failure persists; the decisive current cause is: Blind removal risks taking a healthy member out of a degraded array.

C:

This observation tests an unrelated Given a scenario, perform server hardware maintenance case: An OOB controller firmware update is performed from a guest network without verifying package signatures or a recovery path. It may be true while the current failure persists; the decisive current cause is: Blind removal risks taking a healthy member out of a degraded array.

D:

This observation tests an unrelated Given a scenario, perform server hardware maintenance case: A technician notices that a server is not reachable in-band and powers it off remotely without checking active cluster roles. It may be true while the current failure persists; the decisive current cause is: Blind removal risks taking a healthy member out of a degraded array.