McAfee-Secured Website

Exam Bundle

Exam Code: SK0-005

Exam Name CompTIA Server+ Certification Exam

Certification Provider: CompTIA

Corresponding Certification: CompTIA Server+

CompTIA SK0-005 Bundle $44.99

100% CompTIA SK0-005 Guaranteed Success With Testking Training Materials

Get Real SK0-005 Exam Questions & Expert Verified Answers as Experienced on the Real Exam!

  • Questions & Answers

    SK0-005 Questions & Answers

    617 Questions & Answers

    The ultimate exam preparation tool, Questions & Answers mirrors the actual SK0-005 exam while allowing you to hone and measure every aspect of your test-taking ability.

  • SK0-005 Video Course

    SK0-005 Video Course

    139 Video Lectures

    SK0-005 Video Course is developed by CompTIA Professionals to help you pass the SK0-005 exam.

    Description

    This course will improve your knowledge and skills required to pass CompTIA Server+ Certification Exam exam.
  • Study Guide

    SK0-005 Study Guide

    533 PDF Pages

    Developed by industry experts, this 533-page guide spells out in painstaking detail all of the information you need to ace SK0-005 exam.

CompTIA Server+ Certification Exam (SK0-005) Practice Tests

Satisfaction Guaranteed

Money Back Guarantee

Testking provides hassle-free money back guarantee with our products. That is because we have 100% trust in the abilities of our professional and experience product team, and our record is a proof of that.

99.6% PASS RATE
Total Cost: $194.97
Bundle Price: $149.98

Purchase Individually

  • Questions & Answers

    Questions & Answers

    617 Questions

    $124.99
  • SK0-005 Video Course

    Video Course

    139 Video Lectures

    $39.99
  • Study Guide

    Study Guide

    533 PDF Pages

    $29.99

CompTIA SK0-005 Practice Test 20

Question 190

A server operations team encounters the following situation: A datacenter has several failed drives queued for replacement, but their labels have detached and technicians cannot map logical slots to physical cages. After making the corrective change, which result best demonstrates that this particular problem is resolved?

  1. The replaced member matches the reported serial and the array rebuilds correctly.
  2. POST enumerates the original storage controller and all expected logical drives.
  3. Controller firmware reports the approved version and retains restricted access.
  4. A controlled restart preserves or safely migrates the affected service.

Explanation

Correct Answer

A:

This is incident-specific acceptance evidence: The replaced member matches the reported serial and the array rebuilds correctly. It verifies the action identify failed bays using controller and chassis indicators before removing disks. The failure under test was: Blind removal risks taking a healthy member out of a degraded array.

Incorrect Answers

B:

This observation tests an unrelated Given a scenario, perform server hardware maintenance case: A BIOS update introduces an unsupported RAID controller option ROM, and storage devices disappear during POST. It may be true while the current failure persists; the decisive current cause is: Blind removal risks taking a healthy member out of a degraded array.

C:

This observation tests an unrelated Given a scenario, perform server hardware maintenance case: An OOB controller firmware update is performed from a guest network without verifying package signatures or a recovery path. It may be true while the current failure persists; the decisive current cause is: Blind removal risks taking a healthy member out of a degraded array.

D:

This observation tests an unrelated Given a scenario, perform server hardware maintenance case: A technician notices that a server is not reachable in-band and powers it off remotely without checking active cluster roles. It may be true while the current failure persists; the decisive current cause is: Blind removal risks taking a healthy member out of a degraded array.

Question 191

A server operations team encounters the following situation: A datacenter has several failed drives queued for replacement, but their labels have detached and technicians cannot map logical slots to physical cages. Which underlying cause most specifically explains the observed symptoms?

  1. Out-of-band power action bypasses normal workload shutdown safeguards.
  2. Blind removal risks taking a healthy member out of a degraded array.
  3. OOB controllers expose privileged functions independent of the server OS.
  4. Hardware replacement requires both component compatibility and safe handling.

Explanation

Correct Answer

B:

This root-cause explanation directly accounts for the reported condition: A datacenter has several failed drives queued for replacement, but their labels have detached and technicians cannot map logical slots to physical cages. The corrective step is: Identify failed bays using controller and chassis indicators before removing disks. The verifying outcome is: The replaced member matches the reported serial and the array rebuilds correctly.

Incorrect Answers

A:

This alternative cause would explain a different case: A technician notices that a server is not reachable in-band and powers it off remotely without checking active cluster roles. It does not explain the actual incident's evidence. The present cause is: Blind removal risks taking a healthy member out of a degraded array.

C:

This alternative cause would explain a different case: A management network grants any guest laptop access to the server baseboard management controllers. It does not explain the actual incident's evidence. The present cause is: Blind removal risks taking a healthy member out of a degraded array.

D:

This alternative cause would explain a different case: A maintenance worker attempts to hot-swap a fan while wearing no ESD protection and leaving cables across the service aisle. It does not explain the actual incident's evidence. The present cause is: Blind removal risks taking a healthy member out of a degraded array.

Question 192

A server operations team encounters the following situation: A datacenter has several failed drives queued for replacement, but their labels have detached and technicians cannot map logical slots to physical cages. Which sustained operational control best reduces the likelihood of this same issue recurring?

  1. Include ESD and service clearance in hands-on maintenance checklists.
  2. Audit network segmentation and controller firmware before remote administration.
  3. Maintain controller-to-chassis slot labeling and change records.
  4. Include firmware settings in virtualization preflight checks.

Explanation

Correct Answer

C:

This control targets the underlying recurrence risk: Blind removal risks taking a healthy member out of a degraded array. It builds validation into the affected workflow and supports the expected recovery result: The replaced member matches the reported serial and the array rebuilds correctly.

Incorrect Answers

A:

This control addresses a different scenario: A maintenance worker attempts to hot-swap a fan while wearing no ESD protection and leaving cables across the service aisle. That event's root mechanism was hardware replacement requires both component compatibility and safe handling. The described incident instead arises from: Blind removal risks taking a healthy member out of a degraded array.

B:

This control addresses a different scenario: A management network grants any guest laptop access to the server baseboard management controllers. That event's root mechanism was oOB controllers expose privileged functions independent of the server OS. The described incident instead arises from: Blind removal risks taking a healthy member out of a degraded array.

D:

This control addresses a different scenario: A production system requires BIOS virtualization extensions, but a hypervisor installer reports hardware virtualization disabled. That event's root mechanism was firmware configuration can disable CPU features that hardware physically supports. The described incident instead arises from: Blind removal risks taking a healthy member out of a degraded array.

Question 193

A server operations team encounters the following situation: An OOB controller firmware update is performed from a guest network without verifying package signatures or a recovery path. Given the stated symptoms and constraints, which corrective action is the best next step?

  1. Verify trusted firmware source and use isolated authorized management with documented recovery.
  2. Validate the firmware compatibility matrix and perform a supported recovery or downgrade.
  3. Follow vendor update prerequisites and preserve recoverable configuration before flashing.
  4. Restrict out-of-band interfaces to a dedicated protected management path.

Explanation

Correct Answer

A:

The preferred corrective action directly addresses the incident: An OOB controller firmware update is performed from a guest network without verifying package signatures or a recovery path. The fault mechanism is firmware maintenance crosses a highly privileged management security boundary. Expected confirmation is: Controller firmware reports the approved version and retains restricted access.

Incorrect Answers

B:

This action is better suited to a separate Given a scenario, perform server hardware maintenance incident: A BIOS update introduces an unsupported RAID controller option ROM, and storage devices disappear during POST. That case involves: Firmware component versions can become incompatible even if each package installs. Here the observed mechanism is instead: Firmware maintenance crosses a highly privileged management security boundary. Applying the other repair would not directly resolve this fault.

C:

This action is better suited to a separate Given a scenario, perform server hardware maintenance incident: A technician schedules a BIOS update without checking the vendor's supported firmware sequence and loses a device configuration after reboot. That case involves: Firmware changes can modify hardware initialization and settings. Here the observed mechanism is instead: Firmware maintenance crosses a highly privileged management security boundary. Applying the other repair would not directly resolve this fault.

D:

This action is better suited to a separate Given a scenario, perform server hardware maintenance incident: A management network grants any guest laptop access to the server baseboard management controllers. That case involves: OOB controllers expose privileged functions independent of the server OS. Here the observed mechanism is instead: Firmware maintenance crosses a highly privileged management security boundary. Applying the other repair would not directly resolve this fault.

Question 194

A server operations team encounters the following situation: An OOB controller firmware update is performed from a guest network without verifying package signatures or a recovery path. After making the corrective change, which result best demonstrates that this particular problem is resolved?

  1. The replaced member matches the reported serial and the array rebuilds correctly.
  2. Controller firmware reports the approved version and retains restricted access.
  3. The operator interacts with firmware screens before an operating system is available.
  4. An authorized operator views POST and recovery output without relying on the OS network stack.

Explanation

Correct Answer

B:

This is incident-specific acceptance evidence: Controller firmware reports the approved version and retains restricted access. It verifies the action verify trusted firmware source and use isolated authorized management with documented recovery. The failure under test was: Firmware maintenance crosses a highly privileged management security boundary.

Incorrect Answers

A:

This observation tests an unrelated Given a scenario, perform server hardware maintenance case: A datacenter has several failed drives queued for replacement, but their labels have detached and technicians cannot map logical slots to physical cages. It may be true while the current failure persists; the decisive current cause is: Firmware maintenance crosses a highly privileged management security boundary.

C:

This observation tests an unrelated Given a scenario, perform server hardware maintenance case: A remote host's keyboard stops working during POST and the technician attempts an OS RDP session that cannot start before boot. It may be true while the current failure persists; the decisive current cause is: Firmware maintenance crosses a highly privileged management security boundary.

D:

This observation tests an unrelated Given a scenario, perform server hardware maintenance case: An off-site branch loses its primary OS interface, but the server has a dedicated management controller connected to a separate reachable network. It may be true while the current failure persists; the decisive current cause is: Firmware maintenance crosses a highly privileged management security boundary.

Question 195

A server operations team encounters the following situation: An OOB controller firmware update is performed from a guest network without verifying package signatures or a recovery path. Which underlying cause most specifically explains the observed symptoms?

  1. Matching connector shape does not establish PSU electrical or firmware support.
  2. Incorrect fan removal can eliminate remaining cooling headroom.
  3. Firmware maintenance crosses a highly privileged management security boundary.
  4. OOB controllers expose privileged functions independent of the server OS.

Explanation

Correct Answer

C:

This root-cause explanation directly accounts for the reported condition: An OOB controller firmware update is performed from a guest network without verifying package signatures or a recovery path. The corrective step is: Verify trusted firmware source and use isolated authorized management with documented recovery. The verifying outcome is: Controller firmware reports the approved version and retains restricted access.

Incorrect Answers

A:

This alternative cause would explain a different case: A failed redundant PSU is replaced with a different wattage part that is not supported by the server's chassis model. It does not explain the actual incident's evidence. The present cause is: Firmware maintenance crosses a highly privileged management security boundary.

B:

This alternative cause would explain a different case: A failed redundant fan module is detected while the server is operating but the maintenance team cannot identify which bay may be swapped live. It does not explain the actual incident's evidence. The present cause is: Firmware maintenance crosses a highly privileged management security boundary.

D:

This alternative cause would explain a different case: A management network grants any guest laptop access to the server baseboard management controllers. It does not explain the actual incident's evidence. The present cause is: Firmware maintenance crosses a highly privileged management security boundary.

Question 196

A server operations team encounters the following situation: An OOB controller firmware update is performed from a guest network without verifying package signatures or a recovery path. Which sustained operational control best reduces the likelihood of this same issue recurring?

  1. Include firmware settings in virtualization preflight checks.
  2. Include ESD and service clearance in hands-on maintenance checklists.
  3. Tie replacement carriers to chassis generation and part number.
  4. Require signed update and management-network checks before controller flashing.

Explanation

Correct Answer

D:

This control targets the underlying recurrence risk: Firmware maintenance crosses a highly privileged management security boundary. It builds validation into the affected workflow and supports the expected recovery result: Controller firmware reports the approved version and retains restricted access.

Incorrect Answers

A:

This control addresses a different scenario: A production system requires BIOS virtualization extensions, but a hypervisor installer reports hardware virtualization disabled. That event's root mechanism was firmware configuration can disable CPU features that hardware physically supports. The described incident instead arises from: Firmware maintenance crosses a highly privileged management security boundary.

B:

This control addresses a different scenario: A maintenance worker attempts to hot-swap a fan while wearing no ESD protection and leaving cables across the service aisle. That event's root mechanism was hardware replacement requires both component compatibility and safe handling. The described incident instead arises from: Firmware maintenance crosses a highly privileged management security boundary.

C:

This control addresses a different scenario: A new server's hot-swap drive tray sticks because it is a different generation despite fitting the drive's physical dimensions. That event's root mechanism was physical media size does not guarantee tray and backplane alignment. The described incident instead arises from: Firmware maintenance crosses a highly privileged management security boundary.

Question 197

A server operations team encounters the following situation: A new server's hot-swap drive tray sticks because it is a different generation despite fitting the drive's physical dimensions. Given the stated symptoms and constraints, which corrective action is the best next step?

  1. Replace the approved CMOS battery and verify BIOS/UEFI settings after a cold start.
  2. Obtain the correct supported carrier and use the vendor's insertion procedure.
  3. Validate the firmware compatibility matrix and perform a supported recovery or downgrade.
  4. Use chassis LEDs and service manual to replace only the designated hot-swap fan.

Explanation

Correct Answer

B:

The preferred corrective action directly addresses the incident: A new server's hot-swap drive tray sticks because it is a different generation despite fitting the drive's physical dimensions. The fault mechanism is physical media size does not guarantee tray and backplane alignment. Expected confirmation is: The drive is correctly seated and controller status remains healthy.

Incorrect Answers

A:

This action is better suited to a separate Given a scenario, perform server hardware maintenance incident: A server resets its clock and firmware settings on every complete power loss, while OS time synchronization works temporarily. That case involves: A failing RTC battery loses persistent platform settings between power cycles. Here the observed mechanism is instead: Physical media size does not guarantee tray and backplane alignment. Applying the other repair would not directly resolve this fault.

C:

This action is better suited to a separate Given a scenario, perform server hardware maintenance incident: A BIOS update introduces an unsupported RAID controller option ROM, and storage devices disappear during POST. That case involves: Firmware component versions can become incompatible even if each package installs. Here the observed mechanism is instead: Physical media size does not guarantee tray and backplane alignment. Applying the other repair would not directly resolve this fault.

D:

This action is better suited to a separate Given a scenario, perform server hardware maintenance incident: A failed redundant fan module is detected while the server is operating but the maintenance team cannot identify which bay may be swapped live. That case involves: Incorrect fan removal can eliminate remaining cooling headroom. Here the observed mechanism is instead: Physical media size does not guarantee tray and backplane alignment. Applying the other repair would not directly resolve this fault.

Question 198

A server operations team encounters the following situation: A new server's hot-swap drive tray sticks because it is a different generation despite fitting the drive's physical dimensions. After making the corrective change, which result best demonstrates that this particular problem is resolved?

  1. Guest-subnet connection attempts fail while approved administrators retain access.
  2. POST enumerates the original storage controller and all expected logical drives.
  3. The drive is correctly seated and controller status remains healthy.
  4. Controller firmware reports the approved version and retains restricted access.

Explanation

Correct Answer

C:

This is incident-specific acceptance evidence: The drive is correctly seated and controller status remains healthy. It verifies the action obtain the correct supported carrier and use the vendor's insertion procedure. The failure under test was: Physical media size does not guarantee tray and backplane alignment.

Incorrect Answers

A:

This observation tests an unrelated Given a scenario, perform server hardware maintenance case: A management network grants any guest laptop access to the server baseboard management controllers. It may be true while the current failure persists; the decisive current cause is: Physical media size does not guarantee tray and backplane alignment.

B:

This observation tests an unrelated Given a scenario, perform server hardware maintenance case: A BIOS update introduces an unsupported RAID controller option ROM, and storage devices disappear during POST. It may be true while the current failure persists; the decisive current cause is: Physical media size does not guarantee tray and backplane alignment.

D:

This observation tests an unrelated Given a scenario, perform server hardware maintenance case: An OOB controller firmware update is performed from a guest network without verifying package signatures or a recovery path. It may be true while the current failure persists; the decisive current cause is: Physical media size does not guarantee tray and backplane alignment.

Question 199

A server operations team encounters the following situation: A new server's hot-swap drive tray sticks because it is a different generation despite fitting the drive's physical dimensions. Which underlying cause most specifically explains the observed symptoms?

  1. Blind removal risks taking a healthy member out of a degraded array.
  2. In-band remote desktop depends on the failed operating system interface.
  3. OS remote control cannot replace preboot console access.
  4. Physical media size does not guarantee tray and backplane alignment.

Explanation

Correct Answer

D:

This root-cause explanation directly accounts for the reported condition: A new server's hot-swap drive tray sticks because it is a different generation despite fitting the drive's physical dimensions. The corrective step is: Obtain the correct supported carrier and use the vendor's insertion procedure. The verifying outcome is: The drive is correctly seated and controller status remains healthy.

Incorrect Answers

A:

This alternative cause would explain a different case: A datacenter has several failed drives queued for replacement, but their labels have detached and technicians cannot map logical slots to physical cages. It does not explain the actual incident's evidence. The present cause is: Physical media size does not guarantee tray and backplane alignment.

B:

This alternative cause would explain a different case: An off-site branch loses its primary OS interface, but the server has a dedicated management controller connected to a separate reachable network. It does not explain the actual incident's evidence. The present cause is: Physical media size does not guarantee tray and backplane alignment.

C:

This alternative cause would explain a different case: A remote host's keyboard stops working during POST and the technician attempts an OS RDP session that cannot start before boot. It does not explain the actual incident's evidence. The present cause is: Physical media size does not guarantee tray and backplane alignment.

Question 200

A server operations team encounters the following situation: A new server's hot-swap drive tray sticks because it is a different generation despite fitting the drive's physical dimensions. Which sustained operational control best reduces the likelihood of this same issue recurring?

  1. Tie replacement carriers to chassis generation and part number.
  2. Label hardware as hot-swappable only when its platform actually supports it.
  3. Require service-impact approval for remote power cycling.
  4. Test OOB availability independently of production VLANs.

Explanation

Correct Answer

A:

This control targets the underlying recurrence risk: Physical media size does not guarantee tray and backplane alignment. It builds validation into the affected workflow and supports the expected recovery result: The drive is correctly seated and controller status remains healthy.

Incorrect Answers

B:

This control addresses a different scenario: An administrator replaces a running server's non-hot-pluggable PCIe card without powering down or checking service instructions. That event's root mechanism was not every expansion card supports removal under power. The described incident instead arises from: Physical media size does not guarantee tray and backplane alignment.

C:

This control addresses a different scenario: A technician notices that a server is not reachable in-band and powers it off remotely without checking active cluster roles. That event's root mechanism was out-of-band power action bypasses normal workload shutdown safeguards. The described incident instead arises from: Physical media size does not guarantee tray and backplane alignment.

D:

This control addresses a different scenario: An off-site branch loses its primary OS interface, but the server has a dedicated management controller connected to a separate reachable network. That event's root mechanism was in-band remote desktop depends on the failed operating system interface. The described incident instead arises from: Physical media size does not guarantee tray and backplane alignment.