McAfee-Secured Website

Exam Bundle

Exam Code: SK0-005

Exam Name CompTIA Server+ Certification Exam

Certification Provider: CompTIA

Corresponding Certification: CompTIA Server+

CompTIA SK0-005 Bundle $44.99

100% CompTIA SK0-005 Guaranteed Success With Testking Training Materials

Get Real SK0-005 Exam Questions & Expert Verified Answers as Experienced on the Real Exam!

  • Questions & Answers

    SK0-005 Questions & Answers

    617 Questions & Answers

    The ultimate exam preparation tool, Questions & Answers mirrors the actual SK0-005 exam while allowing you to hone and measure every aspect of your test-taking ability.

  • SK0-005 Video Course

    SK0-005 Video Course

    139 Video Lectures

    SK0-005 Video Course is developed by CompTIA Professionals to help you pass the SK0-005 exam.

    Description

    This course will improve your knowledge and skills required to pass CompTIA Server+ Certification Exam exam.
  • Study Guide

    SK0-005 Study Guide

    533 PDF Pages

    Developed by industry experts, this 533-page guide spells out in painstaking detail all of the information you need to ace SK0-005 exam.

CompTIA Server+ Certification Exam (SK0-005) Practice Tests

Satisfaction Guaranteed

Money Back Guarantee

Testking provides hassle-free money back guarantee with our products. That is because we have 100% trust in the abilities of our professional and experience product team, and our record is a proof of that.

99.6% PASS RATE
Total Cost: $194.97
Bundle Price: $149.98

Purchase Individually

  • Questions & Answers

    Questions & Answers

    617 Questions

    $124.99
  • SK0-005 Video Course

    Video Course

    139 Video Lectures

    $39.99
  • Study Guide

    Study Guide

    533 PDF Pages

    $29.99

CompTIA SK0-005 Practice Test 16

Question 150

A server operations team encounters the following situation: A team expands an existing RAID 6 pool with dissimilar disks and assumes the full largest disk size contributes from each member. After making the corrective change, which result best demonstrates that this particular problem is resolved?

  1. Concurrent access testing preserves a consistent filesystem under the approved configuration.
  2. Benchmarks satisfy read latency and wear limits at the planned cost.
  3. Post-expansion usable capacity matches the controller model and remains protected.
  4. The deleted directory is recovered from a separately retained point in time.

Explanation

Correct Answer

C:

This is incident-specific acceptance evidence: Post-expansion usable capacity matches the controller model and remains protected. It verifies the action check array expansion rules and account for smallest-member or virtual-disk constraints. The failure under test was: Mixed sizes can waste capacity or violate controller layout assumptions.

Incorrect Answers

A:

This observation tests an unrelated Given a scenario, deploy and manage storage case: A SAN volume is assigned to two standalone Windows servers without cluster-aware filesystem controls, and its filesystem becomes corrupt. It may be true while the current failure persists; the decisive current cause is: Mixed sizes can waste capacity or violate controller layout assumptions.

B:

This observation tests an unrelated Given a scenario, deploy and manage storage case: A high-density read cache uses write-intensive SSDs with excessive cost while backend workloads are predominantly sequential reads. It may be true while the current failure persists; the decisive current cause is: Mixed sizes can waste capacity or violate controller layout assumptions.

D:

This observation tests an unrelated Given a scenario, deploy and manage storage case: A RAID 1 pair is mistaken for a backup after an administrator deletes an important directory on the active volume. It may be true while the current failure persists; the decisive current cause is: Mixed sizes can waste capacity or violate controller layout assumptions.

Question 151

A server operations team encounters the following situation: A team expands an existing RAID 6 pool with dissimilar disks and assumes the full largest disk size contributes from each member. Which underlying cause most specifically explains the observed symptoms?

  1. Striping without redundancy provides no fault tolerance.
  2. Parity write operations impose overhead for the transaction pattern.
  3. Connectors and protocols for external storage are not universally interchangeable.
  4. Mixed sizes can waste capacity or violate controller layout assumptions.

Explanation

Correct Answer

D:

This root-cause explanation directly accounts for the reported condition: A team expands an existing RAID 6 pool with dissimilar disks and assumes the full largest disk size contributes from each member. The corrective step is: Check array expansion rules and account for smallest-member or virtual-disk constraints. The verifying outcome is: Post-expansion usable capacity matches the controller model and remains protected.

Incorrect Answers

A:

This alternative cause would explain a different case: A critical database stores its write-ahead log and transaction data in RAID 0 for speed despite requiring continued service after one drive failure. It does not explain the actual incident's evidence. The present cause is: Mixed sizes can waste capacity or violate controller layout assumptions.

B:

This alternative cause would explain a different case: A media server needs mirrored data with high random-write performance, but its chosen RAID 5 group experiences large write penalties. It does not explain the actual incident's evidence. The present cause is: Mixed sizes can waste capacity or violate controller layout assumptions.

C:

This alternative cause would explain a different case: A legacy eSATA disk enclosure loses connectivity because the new server exposes only USB and SAS connectors. It does not explain the actual incident's evidence. The present cause is: Mixed sizes can waste capacity or violate controller layout assumptions.

Question 152

A server operations team encounters the following situation: A team expands an existing RAID 6 pool with dissimilar disks and assumes the full largest disk size contributes from each member. Which sustained operational control best reduces the likelihood of this same issue recurring?

  1. Require tested capacity calculations for heterogeneous RAID expansions.
  2. Document initiator ownership and client file-sharing responsibilities.
  3. Test file-level restore from backups even on fully redundant arrays.
  4. Review shared-disk ownership and fencing before multi-host presentation.

Explanation

Correct Answer

A:

This control targets the underlying recurrence risk: Mixed sizes can waste capacity or violate controller layout assumptions. It builds validation into the affected workflow and supports the expected recovery result: Post-expansion usable capacity matches the controller model and remains protected.

Incorrect Answers

B:

This control addresses a different scenario: An administrator migrates file shares to a SAN LUN and assumes individual client laptops can mount iSCSI block storage as if it were an SMB share. That event's root mechanism was sAN block presentation and NAS file access serve different layers. The described incident instead arises from: Mixed sizes can waste capacity or violate controller layout assumptions.

C:

This control addresses a different scenario: A RAID 1 pair is mistaken for a backup after an administrator deletes an important directory on the active volume. That event's root mechanism was mirroring propagates logical deletions; it is not historical recovery. The described incident instead arises from: Mixed sizes can waste capacity or violate controller layout assumptions.

D:

This control addresses a different scenario: A SAN volume is assigned to two standalone Windows servers without cluster-aware filesystem controls, and its filesystem becomes corrupt. That event's root mechanism was ordinary filesystem drivers cannot safely coordinate unsupervised simultaneous raw block writers. The described incident instead arises from: Mixed sizes can waste capacity or violate controller layout assumptions.

Question 153

A server operations team encounters the following situation: An off-site branch loses its primary OS interface, but the server has a dedicated management controller connected to a separate reachable network. Given the stated symptoms and constraints, which corrective action is the best next step?

  1. Validate the firmware compatibility matrix and perform a supported recovery or downgrade.
  2. Replace the approved CMOS battery and verify BIOS/UEFI settings after a cold start.
  3. Use approved out-of-band remote console to inspect boot state and logs.
  4. Select the manufacturer-compatible replacement and preserve the second healthy feed.

Explanation

Correct Answer

C:

The preferred corrective action directly addresses the incident: An off-site branch loses its primary OS interface, but the server has a dedicated management controller connected to a separate reachable network. The fault mechanism is in-band remote desktop depends on the failed operating system interface. Expected confirmation is: An authorized operator views POST and recovery output without relying on the OS network stack.

Incorrect Answers

A:

This action is better suited to a separate Given a scenario, perform server hardware maintenance incident: A BIOS update introduces an unsupported RAID controller option ROM, and storage devices disappear during POST. That case involves: Firmware component versions can become incompatible even if each package installs. Here the observed mechanism is instead: In-band remote desktop depends on the failed operating system interface. Applying the other repair would not directly resolve this fault.

B:

This action is better suited to a separate Given a scenario, perform server hardware maintenance incident: A server resets its clock and firmware settings on every complete power loss, while OS time synchronization works temporarily. That case involves: A failing RTC battery loses persistent platform settings between power cycles. Here the observed mechanism is instead: In-band remote desktop depends on the failed operating system interface. Applying the other repair would not directly resolve this fault.

D:

This action is better suited to a separate Given a scenario, perform server hardware maintenance incident: A failed redundant PSU is replaced with a different wattage part that is not supported by the server's chassis model. That case involves: Matching connector shape does not establish PSU electrical or firmware support. Here the observed mechanism is instead: In-band remote desktop depends on the failed operating system interface. Applying the other repair would not directly resolve this fault.

Question 154

A server operations team encounters the following situation: An off-site branch loses its primary OS interface, but the server has a dedicated management controller connected to a separate reachable network. After making the corrective change, which result best demonstrates that this particular problem is resolved?

  1. The drive is correctly seated and controller status remains healthy.
  2. Guest-subnet connection attempts fail while approved administrators retain access.
  3. The replaced member matches the reported serial and the array rebuilds correctly.
  4. An authorized operator views POST and recovery output without relying on the OS network stack.

Explanation

Correct Answer

D:

This is incident-specific acceptance evidence: An authorized operator views POST and recovery output without relying on the OS network stack. It verifies the action use approved out-of-band remote console to inspect boot state and logs. The failure under test was: In-band remote desktop depends on the failed operating system interface.

Incorrect Answers

A:

This observation tests an unrelated Given a scenario, perform server hardware maintenance case: A new server's hot-swap drive tray sticks because it is a different generation despite fitting the drive's physical dimensions. It may be true while the current failure persists; the decisive current cause is: In-band remote desktop depends on the failed operating system interface.

B:

This observation tests an unrelated Given a scenario, perform server hardware maintenance case: A management network grants any guest laptop access to the server baseboard management controllers. It may be true while the current failure persists; the decisive current cause is: In-band remote desktop depends on the failed operating system interface.

C:

This observation tests an unrelated Given a scenario, perform server hardware maintenance case: A datacenter has several failed drives queued for replacement, but their labels have detached and technicians cannot map logical slots to physical cages. It may be true while the current failure persists; the decisive current cause is: In-band remote desktop depends on the failed operating system interface.

Question 155

A server operations team encounters the following situation: An off-site branch loses its primary OS interface, but the server has a dedicated management controller connected to a separate reachable network. Which underlying cause most specifically explains the observed symptoms?

  1. In-band remote desktop depends on the failed operating system interface.
  2. Physical media size does not guarantee tray and backplane alignment.
  3. Firmware changes can modify hardware initialization and settings.
  4. OS remote control cannot replace preboot console access.

Explanation

Correct Answer

A:

This root-cause explanation directly accounts for the reported condition: An off-site branch loses its primary OS interface, but the server has a dedicated management controller connected to a separate reachable network. The corrective step is: Use approved out-of-band remote console to inspect boot state and logs. The verifying outcome is: An authorized operator views POST and recovery output without relying on the OS network stack.

Incorrect Answers

B:

This alternative cause would explain a different case: A new server's hot-swap drive tray sticks because it is a different generation despite fitting the drive's physical dimensions. It does not explain the actual incident's evidence. The present cause is: In-band remote desktop depends on the failed operating system interface.

C:

This alternative cause would explain a different case: A technician schedules a BIOS update without checking the vendor's supported firmware sequence and loses a device configuration after reboot. It does not explain the actual incident's evidence. The present cause is: In-band remote desktop depends on the failed operating system interface.

D:

This alternative cause would explain a different case: A remote host's keyboard stops working during POST and the technician attempts an OS RDP session that cannot start before boot. It does not explain the actual incident's evidence. The present cause is: In-band remote desktop depends on the failed operating system interface.

Question 156

A server operations team encounters the following situation: An off-site branch loses its primary OS interface, but the server has a dedicated management controller connected to a separate reachable network. Which sustained operational control best reduces the likelihood of this same issue recurring?

  1. Label hardware as hot-swappable only when its platform actually supports it.
  2. Test OOB availability independently of production VLANs.
  3. Maintain platform-specific firmware change and rollback plans.
  4. Tie replacement carriers to chassis generation and part number.

Explanation

Correct Answer

B:

This control targets the underlying recurrence risk: In-band remote desktop depends on the failed operating system interface. It builds validation into the affected workflow and supports the expected recovery result: An authorized operator views POST and recovery output without relying on the OS network stack.

Incorrect Answers

A:

This control addresses a different scenario: An administrator replaces a running server's non-hot-pluggable PCIe card without powering down or checking service instructions. That event's root mechanism was not every expansion card supports removal under power. The described incident instead arises from: In-band remote desktop depends on the failed operating system interface.

C:

This control addresses a different scenario: A technician schedules a BIOS update without checking the vendor's supported firmware sequence and loses a device configuration after reboot. That event's root mechanism was firmware changes can modify hardware initialization and settings. The described incident instead arises from: In-band remote desktop depends on the failed operating system interface.

D:

This control addresses a different scenario: A new server's hot-swap drive tray sticks because it is a different generation despite fitting the drive's physical dimensions. That event's root mechanism was physical media size does not guarantee tray and backplane alignment. The described incident instead arises from: In-band remote desktop depends on the failed operating system interface.

Question 157

A server operations team encounters the following situation: A technician schedules a BIOS update without checking the vendor's supported firmware sequence and loses a device configuration after reboot. Given the stated symptoms and constraints, which corrective action is the best next step?

  1. Use approved out-of-band remote console to inspect boot state and logs.
  2. Identify failed bays using controller and chassis indicators before removing disks.
  3. Schedule safe shutdown and follow model-specific replacement procedures.
  4. Follow vendor update prerequisites and preserve recoverable configuration before flashing.

Explanation

Correct Answer

D:

The preferred corrective action directly addresses the incident: A technician schedules a BIOS update without checking the vendor's supported firmware sequence and loses a device configuration after reboot. The fault mechanism is firmware changes can modify hardware initialization and settings. Expected confirmation is: The platform boots and firmware inventory matches the tested release.

Incorrect Answers

A:

This action is better suited to a separate Given a scenario, perform server hardware maintenance incident: An off-site branch loses its primary OS interface, but the server has a dedicated management controller connected to a separate reachable network. That case involves: In-band remote desktop depends on the failed operating system interface. Here the observed mechanism is instead: Firmware changes can modify hardware initialization and settings. Applying the other repair would not directly resolve this fault.

B:

This action is better suited to a separate Given a scenario, perform server hardware maintenance incident: A datacenter has several failed drives queued for replacement, but their labels have detached and technicians cannot map logical slots to physical cages. That case involves: Blind removal risks taking a healthy member out of a degraded array. Here the observed mechanism is instead: Firmware changes can modify hardware initialization and settings. Applying the other repair would not directly resolve this fault.

C:

This action is better suited to a separate Given a scenario, perform server hardware maintenance incident: An administrator replaces a running server's non-hot-pluggable PCIe card without powering down or checking service instructions. That case involves: Not every expansion card supports removal under power. Here the observed mechanism is instead: Firmware changes can modify hardware initialization and settings. Applying the other repair would not directly resolve this fault.

Question 158

A server operations team encounters the following situation: A technician schedules a BIOS update without checking the vendor's supported firmware sequence and loses a device configuration after reboot. After making the corrective change, which result best demonstrates that this particular problem is resolved?

  1. The platform boots and firmware inventory matches the tested release.
  2. Both PSU bays report supported redundancy after the change.
  3. Hardware detects the new card after approved servicing with no unexpected fault.
  4. The operator interacts with firmware screens before an operating system is available.

Explanation

Correct Answer

A:

This is incident-specific acceptance evidence: The platform boots and firmware inventory matches the tested release. It verifies the action follow vendor update prerequisites and preserve recoverable configuration before flashing. The failure under test was: Firmware changes can modify hardware initialization and settings.

Incorrect Answers

B:

This observation tests an unrelated Given a scenario, perform server hardware maintenance case: A failed redundant PSU is replaced with a different wattage part that is not supported by the server's chassis model. It may be true while the current failure persists; the decisive current cause is: Firmware changes can modify hardware initialization and settings.

C:

This observation tests an unrelated Given a scenario, perform server hardware maintenance case: An administrator replaces a running server's non-hot-pluggable PCIe card without powering down or checking service instructions. It may be true while the current failure persists; the decisive current cause is: Firmware changes can modify hardware initialization and settings.

D:

This observation tests an unrelated Given a scenario, perform server hardware maintenance case: A remote host's keyboard stops working during POST and the technician attempts an OS RDP session that cannot start before boot. It may be true while the current failure persists; the decisive current cause is: Firmware changes can modify hardware initialization and settings.

Question 159

A server operations team encounters the following situation: A technician schedules a BIOS update without checking the vendor's supported firmware sequence and loses a device configuration after reboot. Which underlying cause most specifically explains the observed symptoms?

  1. In-band remote desktop depends on the failed operating system interface.
  2. Firmware changes can modify hardware initialization and settings.
  3. Blind removal risks taking a healthy member out of a degraded array.
  4. Not every expansion card supports removal under power.

Explanation

Correct Answer

B:

This root-cause explanation directly accounts for the reported condition: A technician schedules a BIOS update without checking the vendor's supported firmware sequence and loses a device configuration after reboot. The corrective step is: Follow vendor update prerequisites and preserve recoverable configuration before flashing. The verifying outcome is: The platform boots and firmware inventory matches the tested release.

Incorrect Answers

A:

This alternative cause would explain a different case: An off-site branch loses its primary OS interface, but the server has a dedicated management controller connected to a separate reachable network. It does not explain the actual incident's evidence. The present cause is: Firmware changes can modify hardware initialization and settings.

C:

This alternative cause would explain a different case: A datacenter has several failed drives queued for replacement, but their labels have detached and technicians cannot map logical slots to physical cages. It does not explain the actual incident's evidence. The present cause is: Firmware changes can modify hardware initialization and settings.

D:

This alternative cause would explain a different case: An administrator replaces a running server's non-hot-pluggable PCIe card without powering down or checking service instructions. It does not explain the actual incident's evidence. The present cause is: Firmware changes can modify hardware initialization and settings.

Question 160

A server operations team encounters the following situation: A technician schedules a BIOS update without checking the vendor's supported firmware sequence and loses a device configuration after reboot. Which sustained operational control best reduces the likelihood of this same issue recurring?

  1. Maintain controller-to-chassis slot labeling and change records.
  2. Include firmware settings in virtualization preflight checks.
  3. Maintain platform-specific firmware change and rollback plans.
  4. Keep model-specific hot-spare compatibility records.

Explanation

Correct Answer

C:

This control targets the underlying recurrence risk: Firmware changes can modify hardware initialization and settings. It builds validation into the affected workflow and supports the expected recovery result: The platform boots and firmware inventory matches the tested release.

Incorrect Answers

A:

This control addresses a different scenario: A datacenter has several failed drives queued for replacement, but their labels have detached and technicians cannot map logical slots to physical cages. That event's root mechanism was blind removal risks taking a healthy member out of a degraded array. The described incident instead arises from: Firmware changes can modify hardware initialization and settings.

B:

This control addresses a different scenario: A production system requires BIOS virtualization extensions, but a hypervisor installer reports hardware virtualization disabled. That event's root mechanism was firmware configuration can disable CPU features that hardware physically supports. The described incident instead arises from: Firmware changes can modify hardware initialization and settings.

D:

This control addresses a different scenario: A failed redundant PSU is replaced with a different wattage part that is not supported by the server's chassis model. That event's root mechanism was matching connector shape does not establish PSU electrical or firmware support. The described incident instead arises from: Firmware changes can modify hardware initialization and settings.