McAfee-Secured Website

Exam Bundle

Exam Code: SK0-005

Exam Name CompTIA Server+ Certification Exam

Certification Provider: CompTIA

Corresponding Certification: CompTIA Server+

CompTIA SK0-005 Bundle $44.99

100% CompTIA SK0-005 Guaranteed Success With Testking Training Materials

Get Real SK0-005 Exam Questions & Expert Verified Answers as Experienced on the Real Exam!

  • Questions & Answers

    SK0-005 Questions & Answers

    617 Questions & Answers

    The ultimate exam preparation tool, Questions & Answers mirrors the actual SK0-005 exam while allowing you to hone and measure every aspect of your test-taking ability.

  • SK0-005 Video Course

    SK0-005 Video Course

    139 Video Lectures

    SK0-005 Video Course is developed by CompTIA Professionals to help you pass the SK0-005 exam.

    Description

    This course will improve your knowledge and skills required to pass CompTIA Server+ Certification Exam exam.
  • Study Guide

    SK0-005 Study Guide

    533 PDF Pages

    Developed by industry experts, this 533-page guide spells out in painstaking detail all of the information you need to ace SK0-005 exam.

CompTIA Server+ Certification Exam (SK0-005) Practice Tests

Satisfaction Guaranteed

Money Back Guarantee

Testking provides hassle-free money back guarantee with our products. That is because we have 100% trust in the abilities of our professional and experience product team, and our record is a proof of that.

99.6% PASS RATE
Total Cost: $194.97
Bundle Price: $149.98

Purchase Individually

  • Questions & Answers

    Questions & Answers

    617 Questions

    $124.99
  • SK0-005 Video Course

    Video Course

    139 Video Lectures

    $39.99
  • Study Guide

    Study Guide

    533 PDF Pages

    $29.99

CompTIA SK0-005 Practice Test 17

Question 160

A server operations team encounters the following situation: A technician schedules a BIOS update without checking the vendor's supported firmware sequence and loses a device configuration after reboot. Which sustained operational control best reduces the likelihood of this same issue recurring?

  1. Maintain controller-to-chassis slot labeling and change records.
  2. Include firmware settings in virtualization preflight checks.
  3. Maintain platform-specific firmware change and rollback plans.
  4. Keep model-specific hot-spare compatibility records.

Explanation

Correct Answer

C:

This control targets the underlying recurrence risk: Firmware changes can modify hardware initialization and settings. It builds validation into the affected workflow and supports the expected recovery result: The platform boots and firmware inventory matches the tested release.

Incorrect Answers

A:

This control addresses a different scenario: A datacenter has several failed drives queued for replacement, but their labels have detached and technicians cannot map logical slots to physical cages. That event's root mechanism was blind removal risks taking a healthy member out of a degraded array. The described incident instead arises from: Firmware changes can modify hardware initialization and settings.

B:

This control addresses a different scenario: A production system requires BIOS virtualization extensions, but a hypervisor installer reports hardware virtualization disabled. That event's root mechanism was firmware configuration can disable CPU features that hardware physically supports. The described incident instead arises from: Firmware changes can modify hardware initialization and settings.

D:

This control addresses a different scenario: A failed redundant PSU is replaced with a different wattage part that is not supported by the server's chassis model. That event's root mechanism was matching connector shape does not establish PSU electrical or firmware support. The described incident instead arises from: Firmware changes can modify hardware initialization and settings.

Question 161

A server operations team encounters the following situation: An administrator replaces a running server's non-hot-pluggable PCIe card without powering down or checking service instructions. Given the stated symptoms and constraints, which corrective action is the best next step?

  1. Schedule safe shutdown and follow model-specific replacement procedures.
  2. Obtain the correct supported carrier and use the vendor's insertion procedure.
  3. Follow electrostatic and physical safety procedures before handling the approved module.
  4. Restrict out-of-band interfaces to a dedicated protected management path.

Explanation

Correct Answer

A:

The preferred corrective action directly addresses the incident: An administrator replaces a running server's non-hot-pluggable PCIe card without powering down or checking service instructions. The fault mechanism is not every expansion card supports removal under power. Expected confirmation is: Hardware detects the new card after approved servicing with no unexpected fault.

Incorrect Answers

B:

This action is better suited to a separate Given a scenario, perform server hardware maintenance incident: A new server's hot-swap drive tray sticks because it is a different generation despite fitting the drive's physical dimensions. That case involves: Physical media size does not guarantee tray and backplane alignment. Here the observed mechanism is instead: Not every expansion card supports removal under power. Applying the other repair would not directly resolve this fault.

C:

This action is better suited to a separate Given a scenario, perform server hardware maintenance incident: A maintenance worker attempts to hot-swap a fan while wearing no ESD protection and leaving cables across the service aisle. That case involves: Hardware replacement requires both component compatibility and safe handling. Here the observed mechanism is instead: Not every expansion card supports removal under power. Applying the other repair would not directly resolve this fault.

D:

This action is better suited to a separate Given a scenario, perform server hardware maintenance incident: A management network grants any guest laptop access to the server baseboard management controllers. That case involves: OOB controllers expose privileged functions independent of the server OS. Here the observed mechanism is instead: Not every expansion card supports removal under power. Applying the other repair would not directly resolve this fault.

Question 162

A server operations team encounters the following situation: An administrator replaces a running server's non-hot-pluggable PCIe card without powering down or checking service instructions. After making the corrective change, which result best demonstrates that this particular problem is resolved?

  1. All fan sensor states return normal with no unexpected thermal shutdown.
  2. Hardware detects the new card after approved servicing with no unexpected fault.
  3. A controlled restart preserves or safely migrates the affected service.
  4. Guest-subnet connection attempts fail while approved administrators retain access.

Explanation

Correct Answer

B:

This is incident-specific acceptance evidence: Hardware detects the new card after approved servicing with no unexpected fault. It verifies the action schedule safe shutdown and follow model-specific replacement procedures. The failure under test was: Not every expansion card supports removal under power.

Incorrect Answers

A:

This observation tests an unrelated Given a scenario, perform server hardware maintenance case: A failed redundant fan module is detected while the server is operating but the maintenance team cannot identify which bay may be swapped live. It may be true while the current failure persists; the decisive current cause is: Not every expansion card supports removal under power.

C:

This observation tests an unrelated Given a scenario, perform server hardware maintenance case: A technician notices that a server is not reachable in-band and powers it off remotely without checking active cluster roles. It may be true while the current failure persists; the decisive current cause is: Not every expansion card supports removal under power.

D:

This observation tests an unrelated Given a scenario, perform server hardware maintenance case: A management network grants any guest laptop access to the server baseboard management controllers. It may be true while the current failure persists; the decisive current cause is: Not every expansion card supports removal under power.

Question 163

A server operations team encounters the following situation: An administrator replaces a running server's non-hot-pluggable PCIe card without powering down or checking service instructions. Which underlying cause most specifically explains the observed symptoms?

  1. OOB controllers expose privileged functions independent of the server OS.
  2. A failing RTC battery loses persistent platform settings between power cycles.
  3. Not every expansion card supports removal under power.
  4. Incorrect fan removal can eliminate remaining cooling headroom.

Explanation

Correct Answer

C:

This root-cause explanation directly accounts for the reported condition: An administrator replaces a running server's non-hot-pluggable PCIe card without powering down or checking service instructions. The corrective step is: Schedule safe shutdown and follow model-specific replacement procedures. The verifying outcome is: Hardware detects the new card after approved servicing with no unexpected fault.

Incorrect Answers

A:

This alternative cause would explain a different case: A management network grants any guest laptop access to the server baseboard management controllers. It does not explain the actual incident's evidence. The present cause is: Not every expansion card supports removal under power.

B:

This alternative cause would explain a different case: A server resets its clock and firmware settings on every complete power loss, while OS time synchronization works temporarily. It does not explain the actual incident's evidence. The present cause is: Not every expansion card supports removal under power.

D:

This alternative cause would explain a different case: A failed redundant fan module is detected while the server is operating but the maintenance team cannot identify which bay may be swapped live. It does not explain the actual incident's evidence. The present cause is: Not every expansion card supports removal under power.

Question 164

A server operations team encounters the following situation: An administrator replaces a running server's non-hot-pluggable PCIe card without powering down or checking service instructions. Which sustained operational control best reduces the likelihood of this same issue recurring?

  1. Capture and periodically audit approved platform boot settings.
  2. Test OOB availability independently of production VLANs.
  3. Include preboot access in remote recovery design.
  4. Label hardware as hot-swappable only when its platform actually supports it.

Explanation

Correct Answer

D:

This control targets the underlying recurrence risk: Not every expansion card supports removal under power. It builds validation into the affected workflow and supports the expected recovery result: Hardware detects the new card after approved servicing with no unexpected fault.

Incorrect Answers

A:

This control addresses a different scenario: A rack server unexpectedly boots from removable media after its UEFI boot order was changed during a repair. That event's root mechanism was firmware boot device priority differs from the intended operating system configuration. The described incident instead arises from: Not every expansion card supports removal under power.

B:

This control addresses a different scenario: An off-site branch loses its primary OS interface, but the server has a dedicated management controller connected to a separate reachable network. That event's root mechanism was in-band remote desktop depends on the failed operating system interface. The described incident instead arises from: Not every expansion card supports removal under power.

C:

This control addresses a different scenario: A remote host's keyboard stops working during POST and the technician attempts an OS RDP session that cannot start before boot. That event's root mechanism was oS remote control cannot replace preboot console access. The described incident instead arises from: Not every expansion card supports removal under power.

Question 165

A server operations team encounters the following situation: A failed redundant fan module is detected while the server is operating but the maintenance team cannot identify which bay may be swapped live. Given the stated symptoms and constraints, which corrective action is the best next step?

  1. Use an IP KVM or approved serial-console path for preboot troubleshooting.
  2. Use chassis LEDs and service manual to replace only the designated hot-swap fan.
  3. Validate the firmware compatibility matrix and perform a supported recovery or downgrade.
  4. Review clustering state and planned maintenance impact before using OOB power controls.

Explanation

Correct Answer

B:

The preferred corrective action directly addresses the incident: A failed redundant fan module is detected while the server is operating but the maintenance team cannot identify which bay may be swapped live. The fault mechanism is incorrect fan removal can eliminate remaining cooling headroom. Expected confirmation is: All fan sensor states return normal with no unexpected thermal shutdown.

Incorrect Answers

A:

This action is better suited to a separate Given a scenario, perform server hardware maintenance incident: A remote host's keyboard stops working during POST and the technician attempts an OS RDP session that cannot start before boot. That case involves: OS remote control cannot replace preboot console access. Here the observed mechanism is instead: Incorrect fan removal can eliminate remaining cooling headroom. Applying the other repair would not directly resolve this fault.

C:

This action is better suited to a separate Given a scenario, perform server hardware maintenance incident: A BIOS update introduces an unsupported RAID controller option ROM, and storage devices disappear during POST. That case involves: Firmware component versions can become incompatible even if each package installs. Here the observed mechanism is instead: Incorrect fan removal can eliminate remaining cooling headroom. Applying the other repair would not directly resolve this fault.

D:

This action is better suited to a separate Given a scenario, perform server hardware maintenance incident: A technician notices that a server is not reachable in-band and powers it off remotely without checking active cluster roles. That case involves: Out-of-band power action bypasses normal workload shutdown safeguards. Here the observed mechanism is instead: Incorrect fan removal can eliminate remaining cooling headroom. Applying the other repair would not directly resolve this fault.

Question 166

A server operations team encounters the following situation: A failed redundant fan module is detected while the server is operating but the maintenance team cannot identify which bay may be swapped live. After making the corrective change, which result best demonstrates that this particular problem is resolved?

  1. The platform boots and firmware inventory matches the tested release.
  2. An authorized operator views POST and recovery output without relying on the OS network stack.
  3. All fan sensor states return normal with no unexpected thermal shutdown.
  4. The replaced member matches the reported serial and the array rebuilds correctly.

Explanation

Correct Answer

C:

This is incident-specific acceptance evidence: All fan sensor states return normal with no unexpected thermal shutdown. It verifies the action use chassis LEDs and service manual to replace only the designated hot-swap fan. The failure under test was: Incorrect fan removal can eliminate remaining cooling headroom.

Incorrect Answers

A:

This observation tests an unrelated Given a scenario, perform server hardware maintenance case: A technician schedules a BIOS update without checking the vendor's supported firmware sequence and loses a device configuration after reboot. It may be true while the current failure persists; the decisive current cause is: Incorrect fan removal can eliminate remaining cooling headroom.

B:

This observation tests an unrelated Given a scenario, perform server hardware maintenance case: An off-site branch loses its primary OS interface, but the server has a dedicated management controller connected to a separate reachable network. It may be true while the current failure persists; the decisive current cause is: Incorrect fan removal can eliminate remaining cooling headroom.

D:

This observation tests an unrelated Given a scenario, perform server hardware maintenance case: A datacenter has several failed drives queued for replacement, but their labels have detached and technicians cannot map logical slots to physical cages. It may be true while the current failure persists; the decisive current cause is: Incorrect fan removal can eliminate remaining cooling headroom.

Question 167

A server operations team encounters the following situation: A failed redundant fan module is detected while the server is operating but the maintenance team cannot identify which bay may be swapped live. Which underlying cause most specifically explains the observed symptoms?

  1. Out-of-band power action bypasses normal workload shutdown safeguards.
  2. In-band remote desktop depends on the failed operating system interface.
  3. Firmware changes can modify hardware initialization and settings.
  4. Incorrect fan removal can eliminate remaining cooling headroom.

Explanation

Correct Answer

D:

This root-cause explanation directly accounts for the reported condition: A failed redundant fan module is detected while the server is operating but the maintenance team cannot identify which bay may be swapped live. The corrective step is: Use chassis LEDs and service manual to replace only the designated hot-swap fan. The verifying outcome is: All fan sensor states return normal with no unexpected thermal shutdown.

Incorrect Answers

A:

This alternative cause would explain a different case: A technician notices that a server is not reachable in-band and powers it off remotely without checking active cluster roles. It does not explain the actual incident's evidence. The present cause is: Incorrect fan removal can eliminate remaining cooling headroom.

B:

This alternative cause would explain a different case: An off-site branch loses its primary OS interface, but the server has a dedicated management controller connected to a separate reachable network. It does not explain the actual incident's evidence. The present cause is: Incorrect fan removal can eliminate remaining cooling headroom.

C:

This alternative cause would explain a different case: A technician schedules a BIOS update without checking the vendor's supported firmware sequence and loses a device configuration after reboot. It does not explain the actual incident's evidence. The present cause is: Incorrect fan removal can eliminate remaining cooling headroom.

Question 168

A server operations team encounters the following situation: A failed redundant fan module is detected while the server is operating but the maintenance team cannot identify which bay may be swapped live. Which sustained operational control best reduces the likelihood of this same issue recurring?

  1. Maintain slot maps and supported live-replacement procedures.
  2. Maintain platform-specific firmware change and rollback plans.
  3. Audit network segmentation and controller firmware before remote administration.
  4. Tie replacement carriers to chassis generation and part number.

Explanation

Correct Answer

A:

This control targets the underlying recurrence risk: Incorrect fan removal can eliminate remaining cooling headroom. It builds validation into the affected workflow and supports the expected recovery result: All fan sensor states return normal with no unexpected thermal shutdown.

Incorrect Answers

B:

This control addresses a different scenario: A technician schedules a BIOS update without checking the vendor's supported firmware sequence and loses a device configuration after reboot. That event's root mechanism was firmware changes can modify hardware initialization and settings. The described incident instead arises from: Incorrect fan removal can eliminate remaining cooling headroom.

C:

This control addresses a different scenario: A management network grants any guest laptop access to the server baseboard management controllers. That event's root mechanism was oOB controllers expose privileged functions independent of the server OS. The described incident instead arises from: Incorrect fan removal can eliminate remaining cooling headroom.

D:

This control addresses a different scenario: A new server's hot-swap drive tray sticks because it is a different generation despite fitting the drive's physical dimensions. That event's root mechanism was physical media size does not guarantee tray and backplane alignment. The described incident instead arises from: Incorrect fan removal can eliminate remaining cooling headroom.

Question 169

A server operations team encounters the following situation: A management network grants any guest laptop access to the server baseboard management controllers. Given the stated symptoms and constraints, which corrective action is the best next step?

  1. Identify failed bays using controller and chassis indicators before removing disks.
  2. Use an IP KVM or approved serial-console path for preboot troubleshooting.
  3. Restrict out-of-band interfaces to a dedicated protected management path.
  4. Replace the approved CMOS battery and verify BIOS/UEFI settings after a cold start.

Explanation

Correct Answer

C:

The preferred corrective action directly addresses the incident: A management network grants any guest laptop access to the server baseboard management controllers. The fault mechanism is oOB controllers expose privileged functions independent of the server OS. Expected confirmation is: Guest-subnet connection attempts fail while approved administrators retain access.

Incorrect Answers

A:

This action is better suited to a separate Given a scenario, perform server hardware maintenance incident: A datacenter has several failed drives queued for replacement, but their labels have detached and technicians cannot map logical slots to physical cages. That case involves: Blind removal risks taking a healthy member out of a degraded array. Here the observed mechanism is instead: OOB controllers expose privileged functions independent of the server OS. Applying the other repair would not directly resolve this fault.

B:

This action is better suited to a separate Given a scenario, perform server hardware maintenance incident: A remote host's keyboard stops working during POST and the technician attempts an OS RDP session that cannot start before boot. That case involves: OS remote control cannot replace preboot console access. Here the observed mechanism is instead: OOB controllers expose privileged functions independent of the server OS. Applying the other repair would not directly resolve this fault.

D:

This action is better suited to a separate Given a scenario, perform server hardware maintenance incident: A server resets its clock and firmware settings on every complete power loss, while OS time synchronization works temporarily. That case involves: A failing RTC battery loses persistent platform settings between power cycles. Here the observed mechanism is instead: OOB controllers expose privileged functions independent of the server OS. Applying the other repair would not directly resolve this fault.

Question 170

A server operations team encounters the following situation: A management network grants any guest laptop access to the server baseboard management controllers. After making the corrective change, which result best demonstrates that this particular problem is resolved?

  1. Controller firmware reports the approved version and retains restricted access.
  2. The drive is correctly seated and controller status remains healthy.
  3. The operator interacts with firmware screens before an operating system is available.
  4. Guest-subnet connection attempts fail while approved administrators retain access.

Explanation

Correct Answer

D:

This is incident-specific acceptance evidence: Guest-subnet connection attempts fail while approved administrators retain access. It verifies the action restrict out-of-band interfaces to a dedicated protected management path. The failure under test was: OOB controllers expose privileged functions independent of the server OS.

Incorrect Answers

A:

This observation tests an unrelated Given a scenario, perform server hardware maintenance case: An OOB controller firmware update is performed from a guest network without verifying package signatures or a recovery path. It may be true while the current failure persists; the decisive current cause is: OOB controllers expose privileged functions independent of the server OS.

B:

This observation tests an unrelated Given a scenario, perform server hardware maintenance case: A new server's hot-swap drive tray sticks because it is a different generation despite fitting the drive's physical dimensions. It may be true while the current failure persists; the decisive current cause is: OOB controllers expose privileged functions independent of the server OS.

C:

This observation tests an unrelated Given a scenario, perform server hardware maintenance case: A remote host's keyboard stops working during POST and the technician attempts an OS RDP session that cannot start before boot. It may be true while the current failure persists; the decisive current cause is: OOB controllers expose privileged functions independent of the server OS.