McAfee-Secured Website

Exam Bundle

Exam Code: SK0-005

Exam Name CompTIA Server+ Certification Exam

Certification Provider: CompTIA

Corresponding Certification: CompTIA Server+

CompTIA SK0-005 Bundle $44.99

100% CompTIA SK0-005 Guaranteed Success With Testking Training Materials

Get Real SK0-005 Exam Questions & Expert Verified Answers as Experienced on the Real Exam!

  • Questions & Answers

    SK0-005 Questions & Answers

    617 Questions & Answers

    The ultimate exam preparation tool, Questions & Answers mirrors the actual SK0-005 exam while allowing you to hone and measure every aspect of your test-taking ability.

  • SK0-005 Video Course

    SK0-005 Video Course

    139 Video Lectures

    SK0-005 Video Course is developed by CompTIA Professionals to help you pass the SK0-005 exam.

    Description

    This course will improve your knowledge and skills required to pass CompTIA Server+ Certification Exam exam.
  • Study Guide

    SK0-005 Study Guide

    533 PDF Pages

    Developed by industry experts, this 533-page guide spells out in painstaking detail all of the information you need to ace SK0-005 exam.

CompTIA Server+ Certification Exam (SK0-005) Practice Tests

Satisfaction Guaranteed

Money Back Guarantee

Testking provides hassle-free money back guarantee with our products. That is because we have 100% trust in the abilities of our professional and experience product team, and our record is a proof of that.

99.6% PASS RATE
Total Cost: $194.97
Bundle Price: $149.98

Purchase Individually

  • Questions & Answers

    Questions & Answers

    617 Questions

    $124.99
  • SK0-005 Video Course

    Video Course

    139 Video Lectures

    $39.99
  • Study Guide

    Study Guide

    533 PDF Pages

    $29.99

CompTIA SK0-005 Practice Test 15

Question 140

A server operations team encounters the following situation: An administrator migrates file shares to a SAN LUN and assumes individual client laptops can mount iSCSI block storage as if it were an SMB share. Which sustained operational control best reduces the likelihood of this same issue recurring?

  1. Benchmark application write mix before selecting RAID level.
  2. Document initiator ownership and client file-sharing responsibilities.
  3. Maintain qualified spare part numbers for each array model.
  4. Verify external-storage interfaces against replacement server ports.

Explanation

Correct Answer

B:

This control targets the underlying recurrence risk: SAN block presentation and NAS file access serve different layers. It builds validation into the affected workflow and supports the expected recovery result: Clients access files through SMB while the server owns and manages the block filesystem.

Incorrect Answers

A:

This control addresses a different scenario: A media server needs mirrored data with high random-write performance, but its chosen RAID 5 group experiences large write penalties. That event's root mechanism was parity write operations impose overhead for the transaction pattern. The described incident instead arises from: SAN block presentation and NAS file access serve different layers.

C:

This control addresses a different scenario: A storage team replaces a 10K RPM SAS drive with a consumer SATA model in a tightly specified redundant server array. That event's root mechanism was drive capacity alone does not guarantee controller, interface or firmware compatibility. The described incident instead arises from: SAN block presentation and NAS file access serve different layers.

D:

This control addresses a different scenario: A legacy eSATA disk enclosure loses connectivity because the new server exposes only USB and SAS connectors. That event's root mechanism was connectors and protocols for external storage are not universally interchangeable. The described incident instead arises from: SAN block presentation and NAS file access serve different layers.

Question 141

A server operations team encounters the following situation: A RAID 1 pair is mistaken for a backup after an administrator deletes an important directory on the active volume. Given the stated symptoms and constraints, which corrective action is the best next step?

  1. Select compliant backup media and off-site retention with integrity validation.
  2. Check controller and array drive compatibility before selecting a supported replacement.
  3. Configure initiator discovery, target authentication and the required storage network path.
  4. Restore from an independent versioned backup rather than relying on mirrored disks.

Explanation

Correct Answer

D:

The preferred corrective action directly addresses the incident: A RAID 1 pair is mistaken for a backup after an administrator deletes an important directory on the active volume. The fault mechanism is mirroring propagates logical deletions; it is not historical recovery. Expected confirmation is: The deleted directory is recovered from a separately retained point in time.

Incorrect Answers

A:

This action is better suited to a separate Given a scenario, deploy and manage storage incident: A backup server uses a single consumer USB SSD as its only long-term archive, although policy requires durable off-site retention. That case involves: One portable disk is a fragile single-copy retention strategy. Here the observed mechanism is instead: Mirroring propagates logical deletions; it is not historical recovery. Applying the other repair would not directly resolve this fault.

B:

This action is better suited to a separate Given a scenario, deploy and manage storage incident: A storage team replaces a 10K RPM SAS drive with a consumer SATA model in a tightly specified redundant server array. That case involves: Drive capacity alone does not guarantee controller, interface or firmware compatibility. Here the observed mechanism is instead: Mirroring propagates logical deletions; it is not historical recovery. Applying the other repair would not directly resolve this fault.

C:

This action is better suited to a separate Given a scenario, deploy and manage storage incident: A server is given an iSCSI target IP but never logs in to the target, so the new logical unit is absent in Disk Management. That case involves: Target address entry alone does not establish an iSCSI session or LUN assignment. Here the observed mechanism is instead: Mirroring propagates logical deletions; it is not historical recovery. Applying the other repair would not directly resolve this fault.

Question 142

A server operations team encounters the following situation: A RAID 1 pair is mistaken for a backup after an administrator deletes an important directory on the active volume. After making the corrective change, which result best demonstrates that this particular problem is resolved?

  1. The deleted directory is recovered from a separately retained point in time.
  2. The controller accepts the drive and the array rebuilds without interface errors.
  3. Post-expansion usable capacity matches the controller model and remains protected.
  4. Provisioned datasets fit with an explicit reserve after full protection overhead.

Explanation

Correct Answer

A:

This is incident-specific acceptance evidence: The deleted directory is recovered from a separately retained point in time. It verifies the action restore from an independent versioned backup rather than relying on mirrored disks. The failure under test was: Mirroring propagates logical deletions; it is not historical recovery.

Incorrect Answers

B:

This observation tests an unrelated Given a scenario, deploy and manage storage case: A storage team replaces a 10K RPM SAS drive with a consumer SATA model in a tightly specified redundant server array. It may be true while the current failure persists; the decisive current cause is: Mirroring propagates logical deletions; it is not historical recovery.

C:

This observation tests an unrelated Given a scenario, deploy and manage storage case: A team expands an existing RAID 6 pool with dissimilar disks and assumes the full largest disk size contributes from each member. It may be true while the current failure persists; the decisive current cause is: Mirroring propagates logical deletions; it is not historical recovery.

D:

This observation tests an unrelated Given a scenario, deploy and manage storage case: A capacity planner chooses a raw 24 TB storage shelf for a 22 TB dataset without space for RAID overhead, snapshots or growth. It may be true while the current failure persists; the decisive current cause is: Mirroring propagates logical deletions; it is not historical recovery.

Question 143

A server operations team encounters the following situation: A RAID 1 pair is mistaken for a backup after an administrator deletes an important directory on the active volume. Which underlying cause most specifically explains the observed symptoms?

  1. Mixed sizes can waste capacity or violate controller layout assumptions.
  2. Mirroring propagates logical deletions; it is not historical recovery.
  3. SAN block presentation and NAS file access serve different layers.
  4. Dual-parity RAID consumes space equal to two member drive capacities.

Explanation

Correct Answer

B:

This root-cause explanation directly accounts for the reported condition: A RAID 1 pair is mistaken for a backup after an administrator deletes an important directory on the active volume. The corrective step is: Restore from an independent versioned backup rather than relying on mirrored disks. The verifying outcome is: The deleted directory is recovered from a separately retained point in time.

Incorrect Answers

A:

This alternative cause would explain a different case: A team expands an existing RAID 6 pool with dissimilar disks and assumes the full largest disk size contributes from each member. It does not explain the actual incident's evidence. The present cause is: Mirroring propagates logical deletions; it is not historical recovery.

C:

This alternative cause would explain a different case: An administrator migrates file shares to a SAN LUN and assumes individual client laptops can mount iSCSI block storage as if it were an SMB share. It does not explain the actual incident's evidence. The present cause is: Mirroring propagates logical deletions; it is not historical recovery.

D:

This alternative cause would explain a different case: An administrator assumes four 8 TB disks configured as RAID 6 will provide 32 TB of usable storage. It does not explain the actual incident's evidence. The present cause is: Mirroring propagates logical deletions; it is not historical recovery.

Question 144

A server operations team encounters the following situation: A RAID 1 pair is mistaken for a backup after an administrator deletes an important directory on the active volume. Which sustained operational control best reduces the likelihood of this same issue recurring?

  1. Benchmark application write mix before selecting RAID level.
  2. Label storage-fabric ports and verify HBA interface type.
  3. Test file-level restore from backups even on fully redundant arrays.
  4. Maintain actual used-versus-usable capacity forecasts for storage expansions.

Explanation

Correct Answer

C:

This control targets the underlying recurrence risk: Mirroring propagates logical deletions; it is not historical recovery. It builds validation into the affected workflow and supports the expected recovery result: The deleted directory is recovered from a separately retained point in time.

Incorrect Answers

A:

This control addresses a different scenario: A media server needs mirrored data with high random-write performance, but its chosen RAID 5 group experiences large write penalties. That event's root mechanism was parity write operations impose overhead for the transaction pattern. The described incident instead arises from: Mirroring propagates logical deletions; it is not historical recovery.

B:

This control addresses a different scenario: A Fibre Channel host bus adapter is inserted into an Ethernet switch because both ports appear to use small optical connectors. That event's root mechanism was fibre Channel framing and Ethernet switching are not interchangeable physical services. The described incident instead arises from: Mirroring propagates logical deletions; it is not historical recovery.

D:

This control addresses a different scenario: A capacity planner chooses a raw 24 TB storage shelf for a 22 TB dataset without space for RAID overhead, snapshots or growth. That event's root mechanism was raw nameplate bytes overstate application-usable storage. The described incident instead arises from: Mirroring propagates logical deletions; it is not historical recovery.

Question 145

A server operations team encounters the following situation: A high-density read cache uses write-intensive SSDs with excessive cost while backend workloads are predominantly sequential reads. Given the stated symptoms and constraints, which corrective action is the best next step?

  1. Right-size read-intensive flash to observed workload and endurance needs.
  2. Deploy compatible shared block or file storage according to the hypervisor's live-migration requirements.
  3. Check controller and array drive compatibility before selecting a supported replacement.
  4. Calculate usable capacity with redundancy, snapshots and projected growth headroom.

Explanation

Correct Answer

A:

The preferred corrective action directly addresses the incident: A high-density read cache uses write-intensive SSDs with excessive cost while backend workloads are predominantly sequential reads. The fault mechanism is drive endurance classes should match actual read-write patterns rather than blanket maximum ratings. Expected confirmation is: Benchmarks satisfy read latency and wear limits at the planned cost.

Incorrect Answers

B:

This action is better suited to a separate Given a scenario, deploy and manage storage incident: A virtualization cluster expects live migration through shared storage, yet its design uses only server-local SATA disks. That case involves: Local disks are not automatically visible to other cluster nodes. Here the observed mechanism is instead: Drive endurance classes should match actual read-write patterns rather than blanket maximum ratings. Applying the other repair would not directly resolve this fault.

C:

This action is better suited to a separate Given a scenario, deploy and manage storage incident: A storage team replaces a 10K RPM SAS drive with a consumer SATA model in a tightly specified redundant server array. That case involves: Drive capacity alone does not guarantee controller, interface or firmware compatibility. Here the observed mechanism is instead: Drive endurance classes should match actual read-write patterns rather than blanket maximum ratings. Applying the other repair would not directly resolve this fault.

D:

This action is better suited to a separate Given a scenario, deploy and manage storage incident: A capacity planner chooses a raw 24 TB storage shelf for a 22 TB dataset without space for RAID overhead, snapshots or growth. That case involves: Raw nameplate bytes overstate application-usable storage. Here the observed mechanism is instead: Drive endurance classes should match actual read-write patterns rather than blanket maximum ratings. Applying the other repair would not directly resolve this fault.

Question 146

A server operations team encounters the following situation: A high-density read cache uses write-intensive SSDs with excessive cost while backend workloads are predominantly sequential reads. After making the corrective change, which result best demonstrates that this particular problem is resolved?

  1. The deleted directory is recovered from a separately retained point in time.
  2. Benchmarks satisfy read latency and wear limits at the planned cost.
  3. The WWPN logs into the fabric and sees only assigned LUNs.
  4. The Windows application creates and locks files over the intended SMB path.

Explanation

Correct Answer

B:

This is incident-specific acceptance evidence: Benchmarks satisfy read latency and wear limits at the planned cost. It verifies the action right-size read-intensive flash to observed workload and endurance needs. The failure under test was: Drive endurance classes should match actual read-write patterns rather than blanket maximum ratings.

Incorrect Answers

A:

This observation tests an unrelated Given a scenario, deploy and manage storage case: A RAID 1 pair is mistaken for a backup after an administrator deletes an important directory on the active volume. It may be true while the current failure persists; the decisive current cause is: Drive endurance classes should match actual read-write patterns rather than blanket maximum ratings.

C:

This observation tests an unrelated Given a scenario, deploy and manage storage case: A Fibre Channel host bus adapter is inserted into an Ethernet switch because both ports appear to use small optical connectors. It may be true while the current failure persists; the decisive current cause is: Drive endurance classes should match actual read-write patterns rather than blanket maximum ratings.

D:

This observation tests an unrelated Given a scenario, deploy and manage storage case: An NFS export works for Linux clients but a Windows service requiring SMB file locking cannot use the same mount protocol. It may be true while the current failure persists; the decisive current cause is: Drive endurance classes should match actual read-write patterns rather than blanket maximum ratings.

Question 147

A server operations team encounters the following situation: A high-density read cache uses write-intensive SSDs with excessive cost while backend workloads are predominantly sequential reads. Which underlying cause most specifically explains the observed symptoms?

  1. Striping without redundancy provides no fault tolerance.
  2. Drive capacity alone does not guarantee controller, interface or firmware compatibility.
  3. Drive endurance classes should match actual read-write patterns rather than blanket maximum ratings.
  4. NAS protocols are not equivalent simply because both provide network file access.

Explanation

Correct Answer

C:

This root-cause explanation directly accounts for the reported condition: A high-density read cache uses write-intensive SSDs with excessive cost while backend workloads are predominantly sequential reads. The corrective step is: Right-size read-intensive flash to observed workload and endurance needs. The verifying outcome is: Benchmarks satisfy read latency and wear limits at the planned cost.

Incorrect Answers

A:

This alternative cause would explain a different case: A critical database stores its write-ahead log and transaction data in RAID 0 for speed despite requiring continued service after one drive failure. It does not explain the actual incident's evidence. The present cause is: Drive endurance classes should match actual read-write patterns rather than blanket maximum ratings.

B:

This alternative cause would explain a different case: A storage team replaces a 10K RPM SAS drive with a consumer SATA model in a tightly specified redundant server array. It does not explain the actual incident's evidence. The present cause is: Drive endurance classes should match actual read-write patterns rather than blanket maximum ratings.

D:

This alternative cause would explain a different case: An NFS export works for Linux clients but a Windows service requiring SMB file locking cannot use the same mount protocol. It does not explain the actual incident's evidence. The present cause is: Drive endurance classes should match actual read-write patterns rather than blanket maximum ratings.

Question 148

A server operations team encounters the following situation: A high-density read cache uses write-intensive SSDs with excessive cost while backend workloads are predominantly sequential reads. Which sustained operational control best reduces the likelihood of this same issue recurring?

  1. Test file-level restore from backups even on fully redundant arrays.
  2. Require tested capacity calculations for heterogeneous RAID expansions.
  3. State redundancy separately from total aggregate disk capacity in design reviews.
  4. Record write amplification and workload profiles for flash tier refreshes.

Explanation

Correct Answer

D:

This control targets the underlying recurrence risk: Drive endurance classes should match actual read-write patterns rather than blanket maximum ratings. It builds validation into the affected workflow and supports the expected recovery result: Benchmarks satisfy read latency and wear limits at the planned cost.

Incorrect Answers

A:

This control addresses a different scenario: A RAID 1 pair is mistaken for a backup after an administrator deletes an important directory on the active volume. That event's root mechanism was mirroring propagates logical deletions; it is not historical recovery. The described incident instead arises from: Drive endurance classes should match actual read-write patterns rather than blanket maximum ratings.

B:

This control addresses a different scenario: A team expands an existing RAID 6 pool with dissimilar disks and assumes the full largest disk size contributes from each member. That event's root mechanism was mixed sizes can waste capacity or violate controller layout assumptions. The described incident instead arises from: Drive endurance classes should match actual read-write patterns rather than blanket maximum ratings.

C:

This control addresses a different scenario: A 12-disk JBOD enclosure is described as fault tolerant because it provides a single combined capacity pool. That event's root mechanism was jBOD by itself does not supply striping parity or mirroring. The described incident instead arises from: Drive endurance classes should match actual read-write patterns rather than blanket maximum ratings.

Question 149

A server operations team encounters the following situation: A team expands an existing RAID 6 pool with dissimilar disks and assumes the full largest disk size contributes from each member. Given the stated symptoms and constraints, which corrective action is the best next step?

  1. Use a suitably sized RAID 6 or another validated two-failure-tolerant design.
  2. Check array expansion rules and account for smallest-member or virtual-disk constraints.
  3. Migrate to a redundant RAID layout appropriate for database I/O and resilience.
  4. Provide a supported SMB/CIFS share with appropriate permissions for the Windows workload.

Explanation

Correct Answer

B:

The preferred corrective action directly addresses the incident: A team expands an existing RAID 6 pool with dissimilar disks and assumes the full largest disk size contributes from each member. The fault mechanism is mixed sizes can waste capacity or violate controller layout assumptions. Expected confirmation is: Post-expansion usable capacity matches the controller model and remains protected.

Incorrect Answers

A:

This action is better suited to a separate Given a scenario, deploy and manage storage incident: A six-disk RAID 5 array is selected for a workload that must survive two simultaneous disk failures during a rebuild. That case involves: Single-parity RAID 5 does not protect against two concurrent disk failures. Here the observed mechanism is instead: Mixed sizes can waste capacity or violate controller layout assumptions. Applying the other repair would not directly resolve this fault.

C:

This action is better suited to a separate Given a scenario, deploy and manage storage incident: A critical database stores its write-ahead log and transaction data in RAID 0 for speed despite requiring continued service after one drive failure. That case involves: Striping without redundancy provides no fault tolerance. Here the observed mechanism is instead: Mixed sizes can waste capacity or violate controller layout assumptions. Applying the other repair would not directly resolve this fault.

D:

This action is better suited to a separate Given a scenario, deploy and manage storage incident: An NFS export works for Linux clients but a Windows service requiring SMB file locking cannot use the same mount protocol. That case involves: NAS protocols are not equivalent simply because both provide network file access. Here the observed mechanism is instead: Mixed sizes can waste capacity or violate controller layout assumptions. Applying the other repair would not directly resolve this fault.

Question 150

A server operations team encounters the following situation: A team expands an existing RAID 6 pool with dissimilar disks and assumes the full largest disk size contributes from each member. After making the corrective change, which result best demonstrates that this particular problem is resolved?

  1. Concurrent access testing preserves a consistent filesystem under the approved configuration.
  2. Benchmarks satisfy read latency and wear limits at the planned cost.
  3. Post-expansion usable capacity matches the controller model and remains protected.
  4. The deleted directory is recovered from a separately retained point in time.

Explanation

Correct Answer

C:

This is incident-specific acceptance evidence: Post-expansion usable capacity matches the controller model and remains protected. It verifies the action check array expansion rules and account for smallest-member or virtual-disk constraints. The failure under test was: Mixed sizes can waste capacity or violate controller layout assumptions.

Incorrect Answers

A:

This observation tests an unrelated Given a scenario, deploy and manage storage case: A SAN volume is assigned to two standalone Windows servers without cluster-aware filesystem controls, and its filesystem becomes corrupt. It may be true while the current failure persists; the decisive current cause is: Mixed sizes can waste capacity or violate controller layout assumptions.

B:

This observation tests an unrelated Given a scenario, deploy and manage storage case: A high-density read cache uses write-intensive SSDs with excessive cost while backend workloads are predominantly sequential reads. It may be true while the current failure persists; the decisive current cause is: Mixed sizes can waste capacity or violate controller layout assumptions.

D:

This observation tests an unrelated Given a scenario, deploy and manage storage case: A RAID 1 pair is mistaken for a backup after an administrator deletes an important directory on the active volume. It may be true while the current failure persists; the decisive current cause is: Mixed sizes can waste capacity or violate controller layout assumptions.