McAfee-Secured Website

Exam Bundle

Exam Code: SK0-005

Exam Name CompTIA Server+ Certification Exam

Certification Provider: CompTIA

Corresponding Certification: CompTIA Server+

CompTIA SK0-005 Bundle $44.99

100% CompTIA SK0-005 Guaranteed Success With Testking Training Materials

Get Real SK0-005 Exam Questions & Expert Verified Answers as Experienced on the Real Exam!

  • Questions & Answers

    SK0-005 Questions & Answers

    617 Questions & Answers

    The ultimate exam preparation tool, Questions & Answers mirrors the actual SK0-005 exam while allowing you to hone and measure every aspect of your test-taking ability.

  • SK0-005 Video Course

    SK0-005 Video Course

    139 Video Lectures

    SK0-005 Video Course is developed by CompTIA Professionals to help you pass the SK0-005 exam.

    Description

    This course will improve your knowledge and skills required to pass CompTIA Server+ Certification Exam exam.
  • Study Guide

    SK0-005 Study Guide

    533 PDF Pages

    Developed by industry experts, this 533-page guide spells out in painstaking detail all of the information you need to ace SK0-005 exam.

CompTIA Server+ Certification Exam (SK0-005) Practice Tests

Satisfaction Guaranteed

Money Back Guarantee

Testking provides hassle-free money back guarantee with our products. That is because we have 100% trust in the abilities of our professional and experience product team, and our record is a proof of that.

99.6% PASS RATE
Total Cost: $194.97
Bundle Price: $149.98

Purchase Individually

  • Questions & Answers

    Questions & Answers

    617 Questions

    $124.99
  • SK0-005 Video Course

    Video Course

    139 Video Lectures

    $39.99
  • Study Guide

    Study Guide

    533 PDF Pages

    $29.99

CompTIA SK0-005 Practice Test 14

Question 130

A server operations team encounters the following situation: A capacity planner chooses a raw 24 TB storage shelf for a 22 TB dataset without space for RAID overhead, snapshots or growth. After making the corrective change, which result best demonstrates that this particular problem is resolved?

  1. Clients access files through SMB while the server owns and manages the block filesystem.
  2. Provisioned datasets fit with an explicit reserve after full protection overhead.
  3. A controlled member failure does not destroy protected data in the revised design.
  4. Benchmarks satisfy read latency and wear limits at the planned cost.

Explanation

Correct Answer

B:

This is incident-specific acceptance evidence: Provisioned datasets fit with an explicit reserve after full protection overhead. It verifies the action calculate usable capacity with redundancy, snapshots and projected growth headroom. The failure under test was: Raw nameplate bytes overstate application-usable storage.

Incorrect Answers

A:

This observation tests an unrelated Given a scenario, deploy and manage storage case: An administrator migrates file shares to a SAN LUN and assumes individual client laptops can mount iSCSI block storage as if it were an SMB share. It may be true while the current failure persists; the decisive current cause is: Raw nameplate bytes overstate application-usable storage.

C:

This observation tests an unrelated Given a scenario, deploy and manage storage case: A 12-disk JBOD enclosure is described as fault tolerant because it provides a single combined capacity pool. It may be true while the current failure persists; the decisive current cause is: Raw nameplate bytes overstate application-usable storage.

D:

This observation tests an unrelated Given a scenario, deploy and manage storage case: A high-density read cache uses write-intensive SSDs with excessive cost while backend workloads are predominantly sequential reads. It may be true while the current failure persists; the decisive current cause is: Raw nameplate bytes overstate application-usable storage.

Question 131

A server operations team encounters the following situation: A capacity planner chooses a raw 24 TB storage shelf for a 22 TB dataset without space for RAID overhead, snapshots or growth. Which underlying cause most specifically explains the observed symptoms?

  1. Read-oriented flash endurance is unsuitable for the sustained write workload.
  2. JBOD by itself does not supply striping parity or mirroring.
  3. Raw nameplate bytes overstate application-usable storage.
  4. One portable disk is a fragile single-copy retention strategy.

Explanation

Correct Answer

C:

This root-cause explanation directly accounts for the reported condition: A capacity planner chooses a raw 24 TB storage shelf for a 22 TB dataset without space for RAID overhead, snapshots or growth. The corrective step is: Calculate usable capacity with redundancy, snapshots and projected growth headroom. The verifying outcome is: Provisioned datasets fit with an explicit reserve after full protection overhead.

Incorrect Answers

A:

This alternative cause would explain a different case: A replacement SSD with lower endurance rating is installed in a high-write logging host, and wear indicators rapidly approach limits. It does not explain the actual incident's evidence. The present cause is: Raw nameplate bytes overstate application-usable storage.

B:

This alternative cause would explain a different case: A 12-disk JBOD enclosure is described as fault tolerant because it provides a single combined capacity pool. It does not explain the actual incident's evidence. The present cause is: Raw nameplate bytes overstate application-usable storage.

D:

This alternative cause would explain a different case: A backup server uses a single consumer USB SSD as its only long-term archive, although policy requires durable off-site retention. It does not explain the actual incident's evidence. The present cause is: Raw nameplate bytes overstate application-usable storage.

Question 132

A server operations team encounters the following situation: A capacity planner chooses a raw 24 TB storage shelf for a 22 TB dataset without space for RAID overhead, snapshots or growth. Which sustained operational control best reduces the likelihood of this same issue recurring?

  1. Document tolerated failures and rebuild exposure in storage design decisions.
  2. Review backup media lifecycle and off-site inventory periodically.
  3. Test file-level restore from backups even on fully redundant arrays.
  4. Maintain actual used-versus-usable capacity forecasts for storage expansions.

Explanation

Correct Answer

D:

This control targets the underlying recurrence risk: Raw nameplate bytes overstate application-usable storage. It builds validation into the affected workflow and supports the expected recovery result: Provisioned datasets fit with an explicit reserve after full protection overhead.

Incorrect Answers

A:

This control addresses a different scenario: A six-disk RAID 5 array is selected for a workload that must survive two simultaneous disk failures during a rebuild. That event's root mechanism was single-parity RAID 5 does not protect against two concurrent disk failures. The described incident instead arises from: Raw nameplate bytes overstate application-usable storage.

B:

This control addresses a different scenario: A backup server uses a single consumer USB SSD as its only long-term archive, although policy requires durable off-site retention. That event's root mechanism was one portable disk is a fragile single-copy retention strategy. The described incident instead arises from: Raw nameplate bytes overstate application-usable storage.

C:

This control addresses a different scenario: A RAID 1 pair is mistaken for a backup after an administrator deletes an important directory on the active volume. That event's root mechanism was mirroring propagates logical deletions; it is not historical recovery. The described incident instead arises from: Raw nameplate bytes overstate application-usable storage.

Question 133

A server operations team encounters the following situation: A legacy eSATA disk enclosure loses connectivity because the new server exposes only USB and SAS connectors. Given the stated symptoms and constraints, which corrective action is the best next step?

  1. Restore from an independent versioned backup rather than relying on mirrored disks.
  2. Use an approved supported interface or adapter path rather than forcing the cable.
  3. Migrate to a redundant RAID layout appropriate for database I/O and resilience.
  4. Use supported clustering and shared-volume coordination or isolate the LUN to one writer.

Explanation

Correct Answer

B:

The preferred corrective action directly addresses the incident: A legacy eSATA disk enclosure loses connectivity because the new server exposes only USB and SAS connectors. The fault mechanism is connectors and protocols for external storage are not universally interchangeable. Expected confirmation is: The external media appears and transfers data without interface errors.

Incorrect Answers

A:

This action is better suited to a separate Given a scenario, deploy and manage storage incident: A RAID 1 pair is mistaken for a backup after an administrator deletes an important directory on the active volume. That case involves: Mirroring propagates logical deletions; it is not historical recovery. Here the observed mechanism is instead: Connectors and protocols for external storage are not universally interchangeable. Applying the other repair would not directly resolve this fault.

C:

This action is better suited to a separate Given a scenario, deploy and manage storage incident: A critical database stores its write-ahead log and transaction data in RAID 0 for speed despite requiring continued service after one drive failure. That case involves: Striping without redundancy provides no fault tolerance. Here the observed mechanism is instead: Connectors and protocols for external storage are not universally interchangeable. Applying the other repair would not directly resolve this fault.

D:

This action is better suited to a separate Given a scenario, deploy and manage storage incident: A SAN volume is assigned to two standalone Windows servers without cluster-aware filesystem controls, and its filesystem becomes corrupt. That case involves: Ordinary filesystem drivers cannot safely coordinate unsupervised simultaneous raw block writers. Here the observed mechanism is instead: Connectors and protocols for external storage are not universally interchangeable. Applying the other repair would not directly resolve this fault.

Question 134

A server operations team encounters the following situation: A legacy eSATA disk enclosure loses connectivity because the new server exposes only USB and SAS connectors. After making the corrective change, which result best demonstrates that this particular problem is resolved?

  1. A representative write workload meets latency targets and survives supported drive failures.
  2. Clients access files through SMB while the server owns and manages the block filesystem.
  3. The external media appears and transfers data without interface errors.
  4. Post-expansion usable capacity matches the controller model and remains protected.

Explanation

Correct Answer

C:

This is incident-specific acceptance evidence: The external media appears and transfers data without interface errors. It verifies the action use an approved supported interface or adapter path rather than forcing the cable. The failure under test was: Connectors and protocols for external storage are not universally interchangeable.

Incorrect Answers

A:

This observation tests an unrelated Given a scenario, deploy and manage storage case: A media server needs mirrored data with high random-write performance, but its chosen RAID 5 group experiences large write penalties. It may be true while the current failure persists; the decisive current cause is: Connectors and protocols for external storage are not universally interchangeable.

B:

This observation tests an unrelated Given a scenario, deploy and manage storage case: An administrator migrates file shares to a SAN LUN and assumes individual client laptops can mount iSCSI block storage as if it were an SMB share. It may be true while the current failure persists; the decisive current cause is: Connectors and protocols for external storage are not universally interchangeable.

D:

This observation tests an unrelated Given a scenario, deploy and manage storage case: A team expands an existing RAID 6 pool with dissimilar disks and assumes the full largest disk size contributes from each member. It may be true while the current failure persists; the decisive current cause is: Connectors and protocols for external storage are not universally interchangeable.

Question 135

A server operations team encounters the following situation: A legacy eSATA disk enclosure loses connectivity because the new server exposes only USB and SAS connectors. Which underlying cause most specifically explains the observed symptoms?

  1. One portable disk is a fragile single-copy retention strategy.
  2. Mirroring propagates logical deletions; it is not historical recovery.
  3. Unprotected controller cache cannot safely preserve acknowledged writes across a power loss.
  4. Connectors and protocols for external storage are not universally interchangeable.

Explanation

Correct Answer

D:

This root-cause explanation directly accounts for the reported condition: A legacy eSATA disk enclosure loses connectivity because the new server exposes only USB and SAS connectors. The corrective step is: Use an approved supported interface or adapter path rather than forcing the cable. The verifying outcome is: The external media appears and transfers data without interface errors.

Incorrect Answers

A:

This alternative cause would explain a different case: A backup server uses a single consumer USB SSD as its only long-term archive, although policy requires durable off-site retention. It does not explain the actual incident's evidence. The present cause is: Connectors and protocols for external storage are not universally interchangeable.

B:

This alternative cause would explain a different case: A RAID 1 pair is mistaken for a backup after an administrator deletes an important directory on the active volume. It does not explain the actual incident's evidence. The present cause is: Connectors and protocols for external storage are not universally interchangeable.

C:

This alternative cause would explain a different case: A RAID array reports write-back cache disabled after its battery protection module failed, and transaction throughput drops sharply. It does not explain the actual incident's evidence. The present cause is: Connectors and protocols for external storage are not universally interchangeable.

Question 136

A server operations team encounters the following situation: A legacy eSATA disk enclosure loses connectivity because the new server exposes only USB and SAS connectors. Which sustained operational control best reduces the likelihood of this same issue recurring?

  1. Verify external-storage interfaces against replacement server ports.
  2. Use conservative RAID capacity planning before procurement.
  3. Match client operating system and application locking requirements to file-sharing protocol.
  4. Monitor controller battery or supercapacitor health and cache policy changes.

Explanation

Correct Answer

A:

This control targets the underlying recurrence risk: Connectors and protocols for external storage are not universally interchangeable. It builds validation into the affected workflow and supports the expected recovery result: The external media appears and transfers data without interface errors.

Incorrect Answers

B:

This control addresses a different scenario: An administrator assumes four 8 TB disks configured as RAID 6 will provide 32 TB of usable storage. That event's root mechanism was dual-parity RAID consumes space equal to two member drive capacities. The described incident instead arises from: Connectors and protocols for external storage are not universally interchangeable.

C:

This control addresses a different scenario: An NFS export works for Linux clients but a Windows service requiring SMB file locking cannot use the same mount protocol. That event's root mechanism was nAS protocols are not equivalent simply because both provide network file access. The described incident instead arises from: Connectors and protocols for external storage are not universally interchangeable.

D:

This control addresses a different scenario: A RAID array reports write-back cache disabled after its battery protection module failed, and transaction throughput drops sharply. That event's root mechanism was unprotected controller cache cannot safely preserve acknowledged writes across a power loss. The described incident instead arises from: Connectors and protocols for external storage are not universally interchangeable.

Question 137

A server operations team encounters the following situation: An administrator migrates file shares to a SAN LUN and assumes individual client laptops can mount iSCSI block storage as if it were an SMB share. Given the stated symptoms and constraints, which corrective action is the best next step?

  1. Provide a supported SMB/CIFS share with appropriate permissions for the Windows workload.
  2. Repair or replace the supported cache protection component before enabling protected write-back caching.
  3. Present block storage to the server and re-export an authorized file service to clients.
  4. Deploy compatible shared block or file storage according to the hypervisor's live-migration requirements.

Explanation

Correct Answer

C:

The preferred corrective action directly addresses the incident: An administrator migrates file shares to a SAN LUN and assumes individual client laptops can mount iSCSI block storage as if it were an SMB share. The fault mechanism is sAN block presentation and NAS file access serve different layers. Expected confirmation is: Clients access files through SMB while the server owns and manages the block filesystem.

Incorrect Answers

A:

This action is better suited to a separate Given a scenario, deploy and manage storage incident: An NFS export works for Linux clients but a Windows service requiring SMB file locking cannot use the same mount protocol. That case involves: NAS protocols are not equivalent simply because both provide network file access. Here the observed mechanism is instead: SAN block presentation and NAS file access serve different layers. Applying the other repair would not directly resolve this fault.

B:

This action is better suited to a separate Given a scenario, deploy and manage storage incident: A RAID array reports write-back cache disabled after its battery protection module failed, and transaction throughput drops sharply. That case involves: Unprotected controller cache cannot safely preserve acknowledged writes across a power loss. Here the observed mechanism is instead: SAN block presentation and NAS file access serve different layers. Applying the other repair would not directly resolve this fault.

D:

This action is better suited to a separate Given a scenario, deploy and manage storage incident: A virtualization cluster expects live migration through shared storage, yet its design uses only server-local SATA disks. That case involves: Local disks are not automatically visible to other cluster nodes. Here the observed mechanism is instead: SAN block presentation and NAS file access serve different layers. Applying the other repair would not directly resolve this fault.

Question 138

A server operations team encounters the following situation: An administrator migrates file shares to a SAN LUN and assumes individual client laptops can mount iSCSI block storage as if it were an SMB share. After making the corrective change, which result best demonstrates that this particular problem is resolved?

  1. Controller diagnostics report healthy cache protection and normal write performance.
  2. The Windows application creates and locks files over the intended SMB path.
  3. Concurrent access testing preserves a consistent filesystem under the approved configuration.
  4. Clients access files through SMB while the server owns and manages the block filesystem.

Explanation

Correct Answer

D:

This is incident-specific acceptance evidence: Clients access files through SMB while the server owns and manages the block filesystem. It verifies the action present block storage to the server and re-export an authorized file service to clients. The failure under test was: SAN block presentation and NAS file access serve different layers.

Incorrect Answers

A:

This observation tests an unrelated Given a scenario, deploy and manage storage case: A RAID array reports write-back cache disabled after its battery protection module failed, and transaction throughput drops sharply. It may be true while the current failure persists; the decisive current cause is: SAN block presentation and NAS file access serve different layers.

B:

This observation tests an unrelated Given a scenario, deploy and manage storage case: An NFS export works for Linux clients but a Windows service requiring SMB file locking cannot use the same mount protocol. It may be true while the current failure persists; the decisive current cause is: SAN block presentation and NAS file access serve different layers.

C:

This observation tests an unrelated Given a scenario, deploy and manage storage case: A SAN volume is assigned to two standalone Windows servers without cluster-aware filesystem controls, and its filesystem becomes corrupt. It may be true while the current failure persists; the decisive current cause is: SAN block presentation and NAS file access serve different layers.

Question 139

A server operations team encounters the following situation: An administrator migrates file shares to a SAN LUN and assumes individual client laptops can mount iSCSI block storage as if it were an SMB share. Which underlying cause most specifically explains the observed symptoms?

  1. SAN block presentation and NAS file access serve different layers.
  2. Mirroring propagates logical deletions; it is not historical recovery.
  3. One portable disk is a fragile single-copy retention strategy.
  4. Drive endurance classes should match actual read-write patterns rather than blanket maximum ratings.

Explanation

Correct Answer

A:

This root-cause explanation directly accounts for the reported condition: An administrator migrates file shares to a SAN LUN and assumes individual client laptops can mount iSCSI block storage as if it were an SMB share. The corrective step is: Present block storage to the server and re-export an authorized file service to clients. The verifying outcome is: Clients access files through SMB while the server owns and manages the block filesystem.

Incorrect Answers

B:

This alternative cause would explain a different case: A RAID 1 pair is mistaken for a backup after an administrator deletes an important directory on the active volume. It does not explain the actual incident's evidence. The present cause is: SAN block presentation and NAS file access serve different layers.

C:

This alternative cause would explain a different case: A backup server uses a single consumer USB SSD as its only long-term archive, although policy requires durable off-site retention. It does not explain the actual incident's evidence. The present cause is: SAN block presentation and NAS file access serve different layers.

D:

This alternative cause would explain a different case: A high-density read cache uses write-intensive SSDs with excessive cost while backend workloads are predominantly sequential reads. It does not explain the actual incident's evidence. The present cause is: SAN block presentation and NAS file access serve different layers.

Question 140

A server operations team encounters the following situation: An administrator migrates file shares to a SAN LUN and assumes individual client laptops can mount iSCSI block storage as if it were an SMB share. Which sustained operational control best reduces the likelihood of this same issue recurring?

  1. Benchmark application write mix before selecting RAID level.
  2. Document initiator ownership and client file-sharing responsibilities.
  3. Maintain qualified spare part numbers for each array model.
  4. Verify external-storage interfaces against replacement server ports.

Explanation

Correct Answer

B:

This control targets the underlying recurrence risk: SAN block presentation and NAS file access serve different layers. It builds validation into the affected workflow and supports the expected recovery result: Clients access files through SMB while the server owns and manages the block filesystem.

Incorrect Answers

A:

This control addresses a different scenario: A media server needs mirrored data with high random-write performance, but its chosen RAID 5 group experiences large write penalties. That event's root mechanism was parity write operations impose overhead for the transaction pattern. The described incident instead arises from: SAN block presentation and NAS file access serve different layers.

C:

This control addresses a different scenario: A storage team replaces a 10K RPM SAS drive with a consumer SATA model in a tightly specified redundant server array. That event's root mechanism was drive capacity alone does not guarantee controller, interface or firmware compatibility. The described incident instead arises from: SAN block presentation and NAS file access serve different layers.

D:

This control addresses a different scenario: A legacy eSATA disk enclosure loses connectivity because the new server exposes only USB and SAS connectors. That event's root mechanism was connectors and protocols for external storage are not universally interchangeable. The described incident instead arises from: SAN block presentation and NAS file access serve different layers.