McAfee-Secured Website

Exam Bundle

Exam Code: SK0-005

Exam Name CompTIA Server+ Certification Exam

Certification Provider: CompTIA

Corresponding Certification: CompTIA Server+

CompTIA SK0-005 Bundle $44.99

100% CompTIA SK0-005 Guaranteed Success With Testking Training Materials

Get Real SK0-005 Exam Questions & Expert Verified Answers as Experienced on the Real Exam!

  • Questions & Answers

    SK0-005 Questions & Answers

    617 Questions & Answers

    The ultimate exam preparation tool, Questions & Answers mirrors the actual SK0-005 exam while allowing you to hone and measure every aspect of your test-taking ability.

  • SK0-005 Video Course

    SK0-005 Video Course

    139 Video Lectures

    SK0-005 Video Course is developed by CompTIA Professionals to help you pass the SK0-005 exam.

    Description

    This course will improve your knowledge and skills required to pass CompTIA Server+ Certification Exam exam.
  • Study Guide

    SK0-005 Study Guide

    533 PDF Pages

    Developed by industry experts, this 533-page guide spells out in painstaking detail all of the information you need to ace SK0-005 exam.

CompTIA Server+ Certification Exam (SK0-005) Practice Tests

Satisfaction Guaranteed

Money Back Guarantee

Testking provides hassle-free money back guarantee with our products. That is because we have 100% trust in the abilities of our professional and experience product team, and our record is a proof of that.

99.6% PASS RATE
Total Cost: $194.97
Bundle Price: $149.98

Purchase Individually

  • Questions & Answers

    Questions & Answers

    617 Questions

    $124.99
  • SK0-005 Video Course

    Video Course

    139 Video Lectures

    $39.99
  • Study Guide

    Study Guide

    533 PDF Pages

    $29.99

CompTIA SK0-005 Practice Test 22

Question 210

A server operations team encounters the following situation: A maintenance worker attempts to hot-swap a fan while wearing no ESD protection and leaving cables across the service aisle. After making the corrective change, which result best demonstrates that this particular problem is resolved?

  1. Controller firmware reports the approved version and retains restricted access.
  2. Component replacement completes without cabling disturbance or chassis error.
  3. A controlled restart preserves or safely migrates the affected service.
  4. The operator interacts with firmware screens before an operating system is available.

Explanation

Correct Answer

B:

This is incident-specific acceptance evidence: Component replacement completes without cabling disturbance or chassis error. It verifies the action follow electrostatic and physical safety procedures before handling the approved module. The failure under test was: Hardware replacement requires both component compatibility and safe handling.

Incorrect Answers

A:

This observation tests an unrelated Given a scenario, perform server hardware maintenance case: An OOB controller firmware update is performed from a guest network without verifying package signatures or a recovery path. It may be true while the current failure persists; the decisive current cause is: Hardware replacement requires both component compatibility and safe handling.

C:

This observation tests an unrelated Given a scenario, perform server hardware maintenance case: A technician notices that a server is not reachable in-band and powers it off remotely without checking active cluster roles. It may be true while the current failure persists; the decisive current cause is: Hardware replacement requires both component compatibility and safe handling.

D:

This observation tests an unrelated Given a scenario, perform server hardware maintenance case: A remote host's keyboard stops working during POST and the technician attempts an OS RDP session that cannot start before boot. It may be true while the current failure persists; the decisive current cause is: Hardware replacement requires both component compatibility and safe handling.

Question 211

A server operations team encounters the following situation: A maintenance worker attempts to hot-swap a fan while wearing no ESD protection and leaving cables across the service aisle. Which underlying cause most specifically explains the observed symptoms?

  1. Firmware changes can modify hardware initialization and settings.
  2. Not every expansion card supports removal under power.
  3. Hardware replacement requires both component compatibility and safe handling.
  4. Physical media size does not guarantee tray and backplane alignment.

Explanation

Correct Answer

C:

This root-cause explanation directly accounts for the reported condition: A maintenance worker attempts to hot-swap a fan while wearing no ESD protection and leaving cables across the service aisle. The corrective step is: Follow electrostatic and physical safety procedures before handling the approved module. The verifying outcome is: Component replacement completes without cabling disturbance or chassis error.

Incorrect Answers

A:

This alternative cause would explain a different case: A technician schedules a BIOS update without checking the vendor's supported firmware sequence and loses a device configuration after reboot. It does not explain the actual incident's evidence. The present cause is: Hardware replacement requires both component compatibility and safe handling.

B:

This alternative cause would explain a different case: An administrator replaces a running server's non-hot-pluggable PCIe card without powering down or checking service instructions. It does not explain the actual incident's evidence. The present cause is: Hardware replacement requires both component compatibility and safe handling.

D:

This alternative cause would explain a different case: A new server's hot-swap drive tray sticks because it is a different generation despite fitting the drive's physical dimensions. It does not explain the actual incident's evidence. The present cause is: Hardware replacement requires both component compatibility and safe handling.

Question 212

A server operations team encounters the following situation: A maintenance worker attempts to hot-swap a fan while wearing no ESD protection and leaving cables across the service aisle. Which sustained operational control best reduces the likelihood of this same issue recurring?

  1. Require signed update and management-network checks before controller flashing.
  2. Include preboot access in remote recovery design.
  3. Capture and periodically audit approved platform boot settings.
  4. Include ESD and service clearance in hands-on maintenance checklists.

Explanation

Correct Answer

D:

This control targets the underlying recurrence risk: Hardware replacement requires both component compatibility and safe handling. It builds validation into the affected workflow and supports the expected recovery result: Component replacement completes without cabling disturbance or chassis error.

Incorrect Answers

A:

This control addresses a different scenario: An OOB controller firmware update is performed from a guest network without verifying package signatures or a recovery path. That event's root mechanism was firmware maintenance crosses a highly privileged management security boundary. The described incident instead arises from: Hardware replacement requires both component compatibility and safe handling.

B:

This control addresses a different scenario: A remote host's keyboard stops working during POST and the technician attempts an OS RDP session that cannot start before boot. That event's root mechanism was oS remote control cannot replace preboot console access. The described incident instead arises from: Hardware replacement requires both component compatibility and safe handling.

C:

This control addresses a different scenario: A rack server unexpectedly boots from removable media after its UEFI boot order was changed during a repair. That event's root mechanism was firmware boot device priority differs from the intended operating system configuration. The described incident instead arises from: Hardware replacement requires both component compatibility and safe handling.

Question 213

A server operations team encounters the following situation: A BIOS update introduces an unsupported RAID controller option ROM, and storage devices disappear during POST. Given the stated symptoms and constraints, which corrective action is the best next step?

  1. Verify trusted firmware source and use isolated authorized management with documented recovery.
  2. Validate the firmware compatibility matrix and perform a supported recovery or downgrade.
  3. Schedule safe shutdown and follow model-specific replacement procedures.
  4. Select the manufacturer-compatible replacement and preserve the second healthy feed.

Explanation

Correct Answer

B:

The preferred corrective action directly addresses the incident: A BIOS update introduces an unsupported RAID controller option ROM, and storage devices disappear during POST. The fault mechanism is firmware component versions can become incompatible even if each package installs. Expected confirmation is: POST enumerates the original storage controller and all expected logical drives.

Incorrect Answers

A:

This action is better suited to a separate Given a scenario, perform server hardware maintenance incident: An OOB controller firmware update is performed from a guest network without verifying package signatures or a recovery path. That case involves: Firmware maintenance crosses a highly privileged management security boundary. Here the observed mechanism is instead: Firmware component versions can become incompatible even if each package installs. Applying the other repair would not directly resolve this fault.

C:

This action is better suited to a separate Given a scenario, perform server hardware maintenance incident: An administrator replaces a running server's non-hot-pluggable PCIe card without powering down or checking service instructions. That case involves: Not every expansion card supports removal under power. Here the observed mechanism is instead: Firmware component versions can become incompatible even if each package installs. Applying the other repair would not directly resolve this fault.

D:

This action is better suited to a separate Given a scenario, perform server hardware maintenance incident: A failed redundant PSU is replaced with a different wattage part that is not supported by the server's chassis model. That case involves: Matching connector shape does not establish PSU electrical or firmware support. Here the observed mechanism is instead: Firmware component versions can become incompatible even if each package installs. Applying the other repair would not directly resolve this fault.

Question 214

A server operations team encounters the following situation: A BIOS update introduces an unsupported RAID controller option ROM, and storage devices disappear during POST. After making the corrective change, which result best demonstrates that this particular problem is resolved?

  1. A controlled restart preserves or safely migrates the affected service.
  2. Hypervisor validation detects virtualization extensions and the host passes compatibility checks.
  3. POST enumerates the original storage controller and all expected logical drives.
  4. Cold boot loads the expected protected system disk rather than USB media.

Explanation

Correct Answer

C:

This is incident-specific acceptance evidence: POST enumerates the original storage controller and all expected logical drives. It verifies the action validate the firmware compatibility matrix and perform a supported recovery or downgrade. The failure under test was: Firmware component versions can become incompatible even if each package installs.

Incorrect Answers

A:

This observation tests an unrelated Given a scenario, perform server hardware maintenance case: A technician notices that a server is not reachable in-band and powers it off remotely without checking active cluster roles. It may be true while the current failure persists; the decisive current cause is: Firmware component versions can become incompatible even if each package installs.

B:

This observation tests an unrelated Given a scenario, perform server hardware maintenance case: A production system requires BIOS virtualization extensions, but a hypervisor installer reports hardware virtualization disabled. It may be true while the current failure persists; the decisive current cause is: Firmware component versions can become incompatible even if each package installs.

D:

This observation tests an unrelated Given a scenario, perform server hardware maintenance case: A rack server unexpectedly boots from removable media after its UEFI boot order was changed during a repair. It may be true while the current failure persists; the decisive current cause is: Firmware component versions can become incompatible even if each package installs.

Question 215

A server operations team encounters the following situation: A BIOS update introduces an unsupported RAID controller option ROM, and storage devices disappear during POST. Which underlying cause most specifically explains the observed symptoms?

  1. Firmware boot device priority differs from the intended operating system configuration.
  2. Physical media size does not guarantee tray and backplane alignment.
  3. OOB controllers expose privileged functions independent of the server OS.
  4. Firmware component versions can become incompatible even if each package installs.

Explanation

Correct Answer

D:

This root-cause explanation directly accounts for the reported condition: A BIOS update introduces an unsupported RAID controller option ROM, and storage devices disappear during POST. The corrective step is: Validate the firmware compatibility matrix and perform a supported recovery or downgrade. The verifying outcome is: POST enumerates the original storage controller and all expected logical drives.

Incorrect Answers

A:

This alternative cause would explain a different case: A rack server unexpectedly boots from removable media after its UEFI boot order was changed during a repair. It does not explain the actual incident's evidence. The present cause is: Firmware component versions can become incompatible even if each package installs.

B:

This alternative cause would explain a different case: A new server's hot-swap drive tray sticks because it is a different generation despite fitting the drive's physical dimensions. It does not explain the actual incident's evidence. The present cause is: Firmware component versions can become incompatible even if each package installs.

C:

This alternative cause would explain a different case: A management network grants any guest laptop access to the server baseboard management controllers. It does not explain the actual incident's evidence. The present cause is: Firmware component versions can become incompatible even if each package installs.

Question 216

A server operations team encounters the following situation: A BIOS update introduces an unsupported RAID controller option ROM, and storage devices disappear during POST. Which sustained operational control best reduces the likelihood of this same issue recurring?

  1. Stage platform firmware changes in a representative nonproduction server.
  2. Include firmware settings in virtualization preflight checks.
  3. Capture and periodically audit approved platform boot settings.
  4. Require signed update and management-network checks before controller flashing.

Explanation

Correct Answer

A:

This control targets the underlying recurrence risk: Firmware component versions can become incompatible even if each package installs. It builds validation into the affected workflow and supports the expected recovery result: POST enumerates the original storage controller and all expected logical drives.

Incorrect Answers

B:

This control addresses a different scenario: A production system requires BIOS virtualization extensions, but a hypervisor installer reports hardware virtualization disabled. That event's root mechanism was firmware configuration can disable CPU features that hardware physically supports. The described incident instead arises from: Firmware component versions can become incompatible even if each package installs.

C:

This control addresses a different scenario: A rack server unexpectedly boots from removable media after its UEFI boot order was changed during a repair. That event's root mechanism was firmware boot device priority differs from the intended operating system configuration. The described incident instead arises from: Firmware component versions can become incompatible even if each package installs.

D:

This control addresses a different scenario: An OOB controller firmware update is performed from a guest network without verifying package signatures or a recovery path. That event's root mechanism was firmware maintenance crosses a highly privileged management security boundary. The described incident instead arises from: Firmware component versions can become incompatible even if each package installs.

Question 217

A server operations team encounters the following situation: A branch installs a new server OS using a generic image that lacks the supported storage controller driver, so setup finds no target disk. Given the stated symptoms and constraints, which corrective action is the best next step?

  1. Choose the appropriate supported filesystem and migrate files while mapping attributes deliberately.
  2. Select GPT partitioning and supported filesystem and boot compatibility where needed.
  3. Inject the tested controller driver into approved installation media or use a compatible installer.
  4. Deploy the supported minimal or core installation with required service components only.

Explanation

Correct Answer

C:

The preferred corrective action directly addresses the incident: A branch installs a new server OS using a generic image that lacks the supported storage controller driver, so setup finds no target disk. The fault mechanism is installation media lacks the driver needed to enumerate the storage controller. Expected confirmation is: The disk is detected and the OS installs under the vendor's supported driver.

Incorrect Answers

A:

This action is better suited to a separate Given a scenario, install server operating systems incident: An administrator copies a Windows NTFS-formatted system image onto a Linux data volume and expects native ext4 ownership and permissions. That case involves: File system semantics and metadata are not automatically identical across platforms. Here the observed mechanism is instead: Installation media lacks the driver needed to enumerate the storage controller. Applying the other repair would not directly resolve this fault.

B:

This action is better suited to a separate Given a scenario, install server operating systems incident: A Linux production node uses a legacy MBR boot layout but a planned 6 TB volume must be partitioned as a single data disk. That case involves: MBR partitioning limits normal single-disk addressing beyond about 2 TiB. Here the observed mechanism is instead: Installation media lacks the driver needed to enumerate the storage controller. Applying the other repair would not directly resolve this fault.

D:

This action is better suited to a separate Given a scenario, install server operating systems incident: A new web host is provisioned with a GUI-heavy operating system even though the hardened baseline calls for a minimal core install. That case involves: The installation choice increases attack surface and management footprint beyond policy. Here the observed mechanism is instead: Installation media lacks the driver needed to enumerate the storage controller. Applying the other repair would not directly resolve this fault.

Question 218

A server operations team encounters the following situation: A branch installs a new server OS using a generic image that lacks the supported storage controller driver, so setup finds no target disk. After making the corrective change, which result best demonstrates that this particular problem is resolved?

  1. Two newly installed nodes join the directory with distinct identities and operate correctly.
  2. The intended large volume is accessible and the server restarts correctly.
  3. Two cloned guests receive unique addresses and access their assigned application VLANs.
  4. The disk is detected and the OS installs under the vendor's supported driver.

Explanation

Correct Answer

D:

This is incident-specific acceptance evidence: The disk is detected and the OS installs under the vendor's supported driver. It verifies the action inject the tested controller driver into approved installation media or use a compatible installer. The failure under test was: Installation media lacks the driver needed to enumerate the storage controller.

Incorrect Answers

A:

This observation tests an unrelated Given a scenario, install server operating systems case: An organization deploys 80 cloned Windows servers with one identical machine identity, causing domain and management conflicts. It may be true while the current failure persists; the decisive current cause is: Installation media lacks the driver needed to enumerate the storage controller.

B:

This observation tests an unrelated Given a scenario, install server operating systems case: A Linux production node uses a legacy MBR boot layout but a planned 6 TB volume must be partitioned as a single data disk. It may be true while the current failure persists; the decisive current cause is: Installation media lacks the driver needed to enumerate the storage controller.

C:

This observation tests an unrelated Given a scenario, install server operating systems case: A VM template contains embedded static IP addresses, and every newly created app server starts with an identical network configuration. It may be true while the current failure persists; the decisive current cause is: Installation media lacks the driver needed to enumerate the storage controller.

Question 219

A server operations team encounters the following situation: A branch installs a new server OS using a generic image that lacks the supported storage controller driver, so setup finds no target disk. Which underlying cause most specifically explains the observed symptoms?

  1. Installation media lacks the driver needed to enumerate the storage controller.
  2. Installation automation conflates replaceable system storage with persistent data volumes.
  3. The selected media workflow requires physical presence that the site cannot supply.
  4. Physical peripheral dependencies can block otherwise successful P2V conversion.

Explanation

Correct Answer

A:

This root-cause explanation directly accounts for the reported condition: A branch installs a new server OS using a generic image that lacks the supported storage controller driver, so setup finds no target disk. The corrective step is: Inject the tested controller driver into approved installation media or use a compatible installer. The verifying outcome is: The disk is detected and the OS installs under the vendor's supported driver.

Incorrect Answers

B:

This alternative cause would explain a different case: A sysadmin assigns every virtual machine the same logical volume label and mountpoint in an automated deployment script, overriding application data during reinstall. It does not explain the actual incident's evidence. The present cause is: Installation media lacks the driver needed to enumerate the storage controller.

C:

This alternative cause would explain a different case: A remote plant must deploy operating systems without local keyboard access, but the team distributes USB installers to every site. It does not explain the actual incident's evidence. The present cause is: Installation media lacks the driver needed to enumerate the storage controller.

D:

This alternative cause would explain a different case: A team migrates a physical print server to a VM without testing pass-through requirements for its legacy parallel-port dongle. It does not explain the actual incident's evidence. The present cause is: Installation media lacks the driver needed to enumerate the storage controller.

Question 220

A server operations team encounters the following situation: A branch installs a new server OS using a generic image that lacks the supported storage controller driver, so setup finds no target disk. Which sustained operational control best reduces the likelihood of this same issue recurring?

  1. Test a media-free cold restart before accepting a new server installation.
  2. Validate hardware drivers and HCL before imaging new server families.
  3. Record processor and firmware support in release readiness gates.
  4. Inventory nonstandard hardware before planning physical-to-virtual migrations.

Explanation

Correct Answer

B:

This control targets the underlying recurrence risk: Installation media lacks the driver needed to enumerate the storage controller. It builds validation into the affected workflow and supports the expected recovery result: The disk is detected and the OS installs under the vendor's supported driver.

Incorrect Answers

A:

This control addresses a different scenario: A new application server boots from removable media after installation because its UEFI boot entry was not created for the new system disk. That event's root mechanism was installation completed but persistent firmware boot configuration was not established. The described incident instead arises from: Installation media lacks the driver needed to enumerate the storage controller.

C:

This control addresses a different scenario: A server upgrade is approved before checking whether the installed CPU architecture meets the new OS minimum requirements. That event's root mechanism was supported software installation depends on more than currently available memory and disk. The described incident instead arises from: Installation media lacks the driver needed to enumerate the storage controller.

D:

This control addresses a different scenario: A team migrates a physical print server to a VM without testing pass-through requirements for its legacy parallel-port dongle. That event's root mechanism was physical peripheral dependencies can block otherwise successful P2V conversion. The described incident instead arises from: Installation media lacks the driver needed to enumerate the storage controller.