McAfee-Secured Website

Exam Bundle

Exam Code: SK0-005

Exam Name CompTIA Server+ Certification Exam

Certification Provider: CompTIA

Corresponding Certification: CompTIA Server+

CompTIA SK0-005 Bundle $44.99

100% CompTIA SK0-005 Guaranteed Success With Testking Training Materials

Get Real SK0-005 Exam Questions & Expert Verified Answers as Experienced on the Real Exam!

  • Questions & Answers

    SK0-005 Questions & Answers

    617 Questions & Answers

    The ultimate exam preparation tool, Questions & Answers mirrors the actual SK0-005 exam while allowing you to hone and measure every aspect of your test-taking ability.

  • SK0-005 Video Course

    SK0-005 Video Course

    139 Video Lectures

    SK0-005 Video Course is developed by CompTIA Professionals to help you pass the SK0-005 exam.

    Description

    This course will improve your knowledge and skills required to pass CompTIA Server+ Certification Exam exam.
  • Study Guide

    SK0-005 Study Guide

    533 PDF Pages

    Developed by industry experts, this 533-page guide spells out in painstaking detail all of the information you need to ace SK0-005 exam.

CompTIA Server+ Certification Exam (SK0-005) Practice Tests

Satisfaction Guaranteed

Money Back Guarantee

Testking provides hassle-free money back guarantee with our products. That is because we have 100% trust in the abilities of our professional and experience product team, and our record is a proof of that.

99.6% PASS RATE
Total Cost: $194.97
Bundle Price: $149.98

Purchase Individually

  • Questions & Answers

    Questions & Answers

    617 Questions

    $124.99
  • SK0-005 Video Course

    Video Course

    139 Video Lectures

    $39.99
  • Study Guide

    Study Guide

    533 PDF Pages

    $29.99

CompTIA SK0-005 Practice Test 12

Question 110

A server operations team encounters the following situation: A RAID array reports write-back cache disabled after its battery protection module failed, and transaction throughput drops sharply. After making the corrective change, which result best demonstrates that this particular problem is resolved?

  1. Controller diagnostics report healthy cache protection and normal write performance.
  2. Post-expansion usable capacity matches the controller model and remains protected.
  3. Benchmarks satisfy read latency and wear limits at the planned cost.
  4. A dated archive remains restorable after the local USB device is unavailable.

Explanation

Correct Answer

A:

This is incident-specific acceptance evidence: Controller diagnostics report healthy cache protection and normal write performance. It verifies the action repair or replace the supported cache protection component before enabling protected write-back caching. The failure under test was: Unprotected controller cache cannot safely preserve acknowledged writes across a power loss.

Incorrect Answers

B:

This observation tests an unrelated Given a scenario, deploy and manage storage case: A team expands an existing RAID 6 pool with dissimilar disks and assumes the full largest disk size contributes from each member. It may be true while the current failure persists; the decisive current cause is: Unprotected controller cache cannot safely preserve acknowledged writes across a power loss.

C:

This observation tests an unrelated Given a scenario, deploy and manage storage case: A high-density read cache uses write-intensive SSDs with excessive cost while backend workloads are predominantly sequential reads. It may be true while the current failure persists; the decisive current cause is: Unprotected controller cache cannot safely preserve acknowledged writes across a power loss.

D:

This observation tests an unrelated Given a scenario, deploy and manage storage case: A backup server uses a single consumer USB SSD as its only long-term archive, although policy requires durable off-site retention. It may be true while the current failure persists; the decisive current cause is: Unprotected controller cache cannot safely preserve acknowledged writes across a power loss.

Question 111

A server operations team encounters the following situation: A RAID array reports write-back cache disabled after its battery protection module failed, and transaction throughput drops sharply. Which underlying cause most specifically explains the observed symptoms?

  1. NAS protocols are not equivalent simply because both provide network file access.
  2. Unprotected controller cache cannot safely preserve acknowledged writes across a power loss.
  3. Striping without redundancy provides no fault tolerance.
  4. Drive endurance classes should match actual read-write patterns rather than blanket maximum ratings.

Explanation

Correct Answer

B:

This root-cause explanation directly accounts for the reported condition: A RAID array reports write-back cache disabled after its battery protection module failed, and transaction throughput drops sharply. The corrective step is: Repair or replace the supported cache protection component before enabling protected write-back caching. The verifying outcome is: Controller diagnostics report healthy cache protection and normal write performance.

Incorrect Answers

A:

This alternative cause would explain a different case: An NFS export works for Linux clients but a Windows service requiring SMB file locking cannot use the same mount protocol. It does not explain the actual incident's evidence. The present cause is: Unprotected controller cache cannot safely preserve acknowledged writes across a power loss.

C:

This alternative cause would explain a different case: A critical database stores its write-ahead log and transaction data in RAID 0 for speed despite requiring continued service after one drive failure. It does not explain the actual incident's evidence. The present cause is: Unprotected controller cache cannot safely preserve acknowledged writes across a power loss.

D:

This alternative cause would explain a different case: A high-density read cache uses write-intensive SSDs with excessive cost while backend workloads are predominantly sequential reads. It does not explain the actual incident's evidence. The present cause is: Unprotected controller cache cannot safely preserve acknowledged writes across a power loss.

Question 112

A server operations team encounters the following situation: A RAID array reports write-back cache disabled after its battery protection module failed, and transaction throughput drops sharply. Which sustained operational control best reduces the likelihood of this same issue recurring?

  1. Maintain qualified spare part numbers for each array model.
  2. Reject nonredundant disk pools for workloads with hardware-failure availability requirements.
  3. Monitor controller battery or supercapacitor health and cache policy changes.
  4. Label storage-fabric ports and verify HBA interface type.

Explanation

Correct Answer

C:

This control targets the underlying recurrence risk: Unprotected controller cache cannot safely preserve acknowledged writes across a power loss. It builds validation into the affected workflow and supports the expected recovery result: Controller diagnostics report healthy cache protection and normal write performance.

Incorrect Answers

A:

This control addresses a different scenario: A storage team replaces a 10K RPM SAS drive with a consumer SATA model in a tightly specified redundant server array. That event's root mechanism was drive capacity alone does not guarantee controller, interface or firmware compatibility. The described incident instead arises from: Unprotected controller cache cannot safely preserve acknowledged writes across a power loss.

B:

This control addresses a different scenario: A critical database stores its write-ahead log and transaction data in RAID 0 for speed despite requiring continued service after one drive failure. That event's root mechanism was striping without redundancy provides no fault tolerance. The described incident instead arises from: Unprotected controller cache cannot safely preserve acknowledged writes across a power loss.

D:

This control addresses a different scenario: A Fibre Channel host bus adapter is inserted into an Ethernet switch because both ports appear to use small optical connectors. That event's root mechanism was fibre Channel framing and Ethernet switching are not interchangeable physical services. The described incident instead arises from: Unprotected controller cache cannot safely preserve acknowledged writes across a power loss.

Question 113

A server operations team encounters the following situation: A SAN volume is assigned to two standalone Windows servers without cluster-aware filesystem controls, and its filesystem becomes corrupt. Given the stated symptoms and constraints, which corrective action is the best next step?

  1. Use supported clustering and shared-volume coordination or isolate the LUN to one writer.
  2. Repair or replace the supported cache protection component before enabling protected write-back caching.
  3. Provide a supported SMB/CIFS share with appropriate permissions for the Windows workload.
  4. Select compliant backup media and off-site retention with integrity validation.

Explanation

Correct Answer

A:

The preferred corrective action directly addresses the incident: A SAN volume is assigned to two standalone Windows servers without cluster-aware filesystem controls, and its filesystem becomes corrupt. The fault mechanism is ordinary filesystem drivers cannot safely coordinate unsupervised simultaneous raw block writers. Expected confirmation is: Concurrent access testing preserves a consistent filesystem under the approved configuration.

Incorrect Answers

B:

This action is better suited to a separate Given a scenario, deploy and manage storage incident: A RAID array reports write-back cache disabled after its battery protection module failed, and transaction throughput drops sharply. That case involves: Unprotected controller cache cannot safely preserve acknowledged writes across a power loss. Here the observed mechanism is instead: Ordinary filesystem drivers cannot safely coordinate unsupervised simultaneous raw block writers. Applying the other repair would not directly resolve this fault.

C:

This action is better suited to a separate Given a scenario, deploy and manage storage incident: An NFS export works for Linux clients but a Windows service requiring SMB file locking cannot use the same mount protocol. That case involves: NAS protocols are not equivalent simply because both provide network file access. Here the observed mechanism is instead: Ordinary filesystem drivers cannot safely coordinate unsupervised simultaneous raw block writers. Applying the other repair would not directly resolve this fault.

D:

This action is better suited to a separate Given a scenario, deploy and manage storage incident: A backup server uses a single consumer USB SSD as its only long-term archive, although policy requires durable off-site retention. That case involves: One portable disk is a fragile single-copy retention strategy. Here the observed mechanism is instead: Ordinary filesystem drivers cannot safely coordinate unsupervised simultaneous raw block writers. Applying the other repair would not directly resolve this fault.

Question 114

A server operations team encounters the following situation: A SAN volume is assigned to two standalone Windows servers without cluster-aware filesystem controls, and its filesystem becomes corrupt. After making the corrective change, which result best demonstrates that this particular problem is resolved?

  1. Post-expansion usable capacity matches the controller model and remains protected.
  2. Concurrent access testing preserves a consistent filesystem under the approved configuration.
  3. Provisioned datasets fit with an explicit reserve after full protection overhead.
  4. The WWPN logs into the fabric and sees only assigned LUNs.

Explanation

Correct Answer

B:

This is incident-specific acceptance evidence: Concurrent access testing preserves a consistent filesystem under the approved configuration. It verifies the action use supported clustering and shared-volume coordination or isolate the LUN to one writer. The failure under test was: Ordinary filesystem drivers cannot safely coordinate unsupervised simultaneous raw block writers.

Incorrect Answers

A:

This observation tests an unrelated Given a scenario, deploy and manage storage case: A team expands an existing RAID 6 pool with dissimilar disks and assumes the full largest disk size contributes from each member. It may be true while the current failure persists; the decisive current cause is: Ordinary filesystem drivers cannot safely coordinate unsupervised simultaneous raw block writers.

C:

This observation tests an unrelated Given a scenario, deploy and manage storage case: A capacity planner chooses a raw 24 TB storage shelf for a 22 TB dataset without space for RAID overhead, snapshots or growth. It may be true while the current failure persists; the decisive current cause is: Ordinary filesystem drivers cannot safely coordinate unsupervised simultaneous raw block writers.

D:

This observation tests an unrelated Given a scenario, deploy and manage storage case: A Fibre Channel host bus adapter is inserted into an Ethernet switch because both ports appear to use small optical connectors. It may be true while the current failure persists; the decisive current cause is: Ordinary filesystem drivers cannot safely coordinate unsupervised simultaneous raw block writers.

Question 115

A server operations team encounters the following situation: A SAN volume is assigned to two standalone Windows servers without cluster-aware filesystem controls, and its filesystem becomes corrupt. Which underlying cause most specifically explains the observed symptoms?

  1. One portable disk is a fragile single-copy retention strategy.
  2. JBOD by itself does not supply striping parity or mirroring.
  3. Ordinary filesystem drivers cannot safely coordinate unsupervised simultaneous raw block writers.
  4. Unprotected controller cache cannot safely preserve acknowledged writes across a power loss.

Explanation

Correct Answer

C:

This root-cause explanation directly accounts for the reported condition: A SAN volume is assigned to two standalone Windows servers without cluster-aware filesystem controls, and its filesystem becomes corrupt. The corrective step is: Use supported clustering and shared-volume coordination or isolate the LUN to one writer. The verifying outcome is: Concurrent access testing preserves a consistent filesystem under the approved configuration.

Incorrect Answers

A:

This alternative cause would explain a different case: A backup server uses a single consumer USB SSD as its only long-term archive, although policy requires durable off-site retention. It does not explain the actual incident's evidence. The present cause is: Ordinary filesystem drivers cannot safely coordinate unsupervised simultaneous raw block writers.

B:

This alternative cause would explain a different case: A 12-disk JBOD enclosure is described as fault tolerant because it provides a single combined capacity pool. It does not explain the actual incident's evidence. The present cause is: Ordinary filesystem drivers cannot safely coordinate unsupervised simultaneous raw block writers.

D:

This alternative cause would explain a different case: A RAID array reports write-back cache disabled after its battery protection module failed, and transaction throughput drops sharply. It does not explain the actual incident's evidence. The present cause is: Ordinary filesystem drivers cannot safely coordinate unsupervised simultaneous raw block writers.

Question 116

A server operations team encounters the following situation: A SAN volume is assigned to two standalone Windows servers without cluster-aware filesystem controls, and its filesystem becomes corrupt. Which sustained operational control best reduces the likelihood of this same issue recurring?

  1. Document tolerated failures and rebuild exposure in storage design decisions.
  2. Include total bytes written and endurance class in drive procurement.
  3. Require tested capacity calculations for heterogeneous RAID expansions.
  4. Review shared-disk ownership and fencing before multi-host presentation.

Explanation

Correct Answer

D:

This control targets the underlying recurrence risk: Ordinary filesystem drivers cannot safely coordinate unsupervised simultaneous raw block writers. It builds validation into the affected workflow and supports the expected recovery result: Concurrent access testing preserves a consistent filesystem under the approved configuration.

Incorrect Answers

A:

This control addresses a different scenario: A six-disk RAID 5 array is selected for a workload that must survive two simultaneous disk failures during a rebuild. That event's root mechanism was single-parity RAID 5 does not protect against two concurrent disk failures. The described incident instead arises from: Ordinary filesystem drivers cannot safely coordinate unsupervised simultaneous raw block writers.

B:

This control addresses a different scenario: A replacement SSD with lower endurance rating is installed in a high-write logging host, and wear indicators rapidly approach limits. That event's root mechanism was read-oriented flash endurance is unsuitable for the sustained write workload. The described incident instead arises from: Ordinary filesystem drivers cannot safely coordinate unsupervised simultaneous raw block writers.

C:

This control addresses a different scenario: A team expands an existing RAID 6 pool with dissimilar disks and assumes the full largest disk size contributes from each member. That event's root mechanism was mixed sizes can waste capacity or violate controller layout assumptions. The described incident instead arises from: Ordinary filesystem drivers cannot safely coordinate unsupervised simultaneous raw block writers.

Question 117

A server operations team encounters the following situation: A storage team replaces a 10K RPM SAS drive with a consumer SATA model in a tightly specified redundant server array. Given the stated symptoms and constraints, which corrective action is the best next step?

  1. Use a suitably sized RAID 6 or another validated two-failure-tolerant design.
  2. Check controller and array drive compatibility before selecting a supported replacement.
  3. Restore from an independent versioned backup rather than relying on mirrored disks.
  4. Plan usable capacity after two drives' worth of parity and applicable filesystem overhead.

Explanation

Correct Answer

B:

The preferred corrective action directly addresses the incident: A storage team replaces a 10K RPM SAS drive with a consumer SATA model in a tightly specified redundant server array. The fault mechanism is drive capacity alone does not guarantee controller, interface or firmware compatibility. Expected confirmation is: The controller accepts the drive and the array rebuilds without interface errors.

Incorrect Answers

A:

This action is better suited to a separate Given a scenario, deploy and manage storage incident: A six-disk RAID 5 array is selected for a workload that must survive two simultaneous disk failures during a rebuild. That case involves: Single-parity RAID 5 does not protect against two concurrent disk failures. Here the observed mechanism is instead: Drive capacity alone does not guarantee controller, interface or firmware compatibility. Applying the other repair would not directly resolve this fault.

C:

This action is better suited to a separate Given a scenario, deploy and manage storage incident: A RAID 1 pair is mistaken for a backup after an administrator deletes an important directory on the active volume. That case involves: Mirroring propagates logical deletions; it is not historical recovery. Here the observed mechanism is instead: Drive capacity alone does not guarantee controller, interface or firmware compatibility. Applying the other repair would not directly resolve this fault.

D:

This action is better suited to a separate Given a scenario, deploy and manage storage incident: An administrator assumes four 8 TB disks configured as RAID 6 will provide 32 TB of usable storage. That case involves: Dual-parity RAID consumes space equal to two member drive capacities. Here the observed mechanism is instead: Drive capacity alone does not guarantee controller, interface or firmware compatibility. Applying the other repair would not directly resolve this fault.

Question 118

A server operations team encounters the following situation: A storage team replaces a 10K RPM SAS drive with a consumer SATA model in a tightly specified redundant server array. After making the corrective change, which result best demonstrates that this particular problem is resolved?

  1. Concurrent access testing preserves a consistent filesystem under the approved configuration.
  2. A representative write workload meets latency targets and survives supported drive failures.
  3. The controller accepts the drive and the array rebuilds without interface errors.
  4. The service remains available after a simulated single-disk failure.

Explanation

Correct Answer

C:

This is incident-specific acceptance evidence: The controller accepts the drive and the array rebuilds without interface errors. It verifies the action check controller and array drive compatibility before selecting a supported replacement. The failure under test was: Drive capacity alone does not guarantee controller, interface or firmware compatibility.

Incorrect Answers

A:

This observation tests an unrelated Given a scenario, deploy and manage storage case: A SAN volume is assigned to two standalone Windows servers without cluster-aware filesystem controls, and its filesystem becomes corrupt. It may be true while the current failure persists; the decisive current cause is: Drive capacity alone does not guarantee controller, interface or firmware compatibility.

B:

This observation tests an unrelated Given a scenario, deploy and manage storage case: A media server needs mirrored data with high random-write performance, but its chosen RAID 5 group experiences large write penalties. It may be true while the current failure persists; the decisive current cause is: Drive capacity alone does not guarantee controller, interface or firmware compatibility.

D:

This observation tests an unrelated Given a scenario, deploy and manage storage case: A critical database stores its write-ahead log and transaction data in RAID 0 for speed despite requiring continued service after one drive failure. It may be true while the current failure persists; the decisive current cause is: Drive capacity alone does not guarantee controller, interface or firmware compatibility.

Question 119

A server operations team encounters the following situation: A storage team replaces a 10K RPM SAS drive with a consumer SATA model in a tightly specified redundant server array. Which underlying cause most specifically explains the observed symptoms?

  1. Fibre Channel framing and Ethernet switching are not interchangeable physical services.
  2. Parity write operations impose overhead for the transaction pattern.
  3. Single-parity RAID 5 does not protect against two concurrent disk failures.
  4. Drive capacity alone does not guarantee controller, interface or firmware compatibility.

Explanation

Correct Answer

D:

This root-cause explanation directly accounts for the reported condition: A storage team replaces a 10K RPM SAS drive with a consumer SATA model in a tightly specified redundant server array. The corrective step is: Check controller and array drive compatibility before selecting a supported replacement. The verifying outcome is: The controller accepts the drive and the array rebuilds without interface errors.

Incorrect Answers

A:

This alternative cause would explain a different case: A Fibre Channel host bus adapter is inserted into an Ethernet switch because both ports appear to use small optical connectors. It does not explain the actual incident's evidence. The present cause is: Drive capacity alone does not guarantee controller, interface or firmware compatibility.

B:

This alternative cause would explain a different case: A media server needs mirrored data with high random-write performance, but its chosen RAID 5 group experiences large write penalties. It does not explain the actual incident's evidence. The present cause is: Drive capacity alone does not guarantee controller, interface or firmware compatibility.

C:

This alternative cause would explain a different case: A six-disk RAID 5 array is selected for a workload that must survive two simultaneous disk failures during a rebuild. It does not explain the actual incident's evidence. The present cause is: Drive capacity alone does not guarantee controller, interface or firmware compatibility.

Question 120

A server operations team encounters the following situation: A storage team replaces a 10K RPM SAS drive with a consumer SATA model in a tightly specified redundant server array. Which sustained operational control best reduces the likelihood of this same issue recurring?

  1. Maintain qualified spare part numbers for each array model.
  2. Reject nonredundant disk pools for workloads with hardware-failure availability requirements.
  3. Test file-level restore from backups even on fully redundant arrays.
  4. Document tolerated failures and rebuild exposure in storage design decisions.

Explanation

Correct Answer

A:

This control targets the underlying recurrence risk: Drive capacity alone does not guarantee controller, interface or firmware compatibility. It builds validation into the affected workflow and supports the expected recovery result: The controller accepts the drive and the array rebuilds without interface errors.

Incorrect Answers

B:

This control addresses a different scenario: A critical database stores its write-ahead log and transaction data in RAID 0 for speed despite requiring continued service after one drive failure. That event's root mechanism was striping without redundancy provides no fault tolerance. The described incident instead arises from: Drive capacity alone does not guarantee controller, interface or firmware compatibility.

C:

This control addresses a different scenario: A RAID 1 pair is mistaken for a backup after an administrator deletes an important directory on the active volume. That event's root mechanism was mirroring propagates logical deletions; it is not historical recovery. The described incident instead arises from: Drive capacity alone does not guarantee controller, interface or firmware compatibility.

D:

This control addresses a different scenario: A six-disk RAID 5 array is selected for a workload that must survive two simultaneous disk failures during a rebuild. That event's root mechanism was single-parity RAID 5 does not protect against two concurrent disk failures. The described incident instead arises from: Drive capacity alone does not guarantee controller, interface or firmware compatibility.