McAfee-Secured Website

Exam Bundle

Exam Code: 220-1201

Exam Name CompTIA A+ Certification Exam: Core 1

Certification Provider: CompTIA

Corresponding Certification: CompTIA A+

CompTIA 220-1201 Bundle $44.99

100% CompTIA 220-1201 Guaranteed Success With Testking Training Materials

Get Real 220-1201 Exam Questions & Expert Verified Answers as Experienced on the Real Exam!

  • Questions & Answers

    220-1201 Questions & Answers

    527 Questions & Answers

    The ultimate exam preparation tool, Questions & Answers mirrors the actual 220-1201 exam while allowing you to hone and measure every aspect of your test-taking ability.

  • 220-1201 Video Course

    220-1201 Video Course

    106 Video Lectures

    220-1201 Video Course is developed by CompTIA Professionals to help you pass the 220-1201 exam.

    Description

    This course will improve your knowledge and skills required to pass CompTIA A+ Certification Exam: Core 1 exam.
  • Study Guide

    220-1201 Study Guide

    2615 PDF Pages

    Developed by industry experts, this 2615-page guide spells out in painstaking detail all of the information you need to ace 220-1201 exam.

CompTIA A+ Certification Exam: Core 1 (220-1201) Practice Tests

Satisfaction Guaranteed

Money Back Guarantee

Testking provides hassle-free money back guarantee with our products. That is because we have 100% trust in the abilities of our professional and experience product team, and our record is a proof of that.

99.6% PASS RATE
Total Cost: $194.97
Bundle Price: $149.98

Purchase Individually

  • Questions & Answers

    Questions & Answers

    527 Questions

    $124.99
  • 220-1201 Video Course

    Video Course

    106 Video Lectures

    $39.99
  • Study Guide

    Study Guide

    2615 PDF Pages

    $29.99

CompTIA 220-1201 Practice Test 46

Question 450

A small office PC blue-screens intermittently and a bootable memory diagnostic records reproducible address errors. After the appropriate change, which observation BEST verifies the intended result?

  1. POST completes with a known-good memory configuration.
  2. A representative GPU/CPU stress test completes without shutdown.
  3. Extended memory diagnostics run without bit errors.
  4. The existing OS boots without repartitioning the storage.

Explanation

Correct Answer

C:

Reproducible RAM errors indicate faulty memory rather than disk capacity. The outcome “Extended memory diagnostics run without bit errors.” verifies the action “Replace the failing memory module identified through isolation.” for this situation: A small office PC blue-screens intermittently and a bootable memory diagnostic records reproducible address errors.

Incorrect Answers

A:

POST beep patterns can localize a failure to RAM before the OS loads. For the situation described—A small office PC blue-screens intermittently and a bootable memory diagnostic records reproducible address errors—this would not demonstrate the specified intervention. The relevant evidence is “Extended memory diagnostics run without bit errors.”.

B:

High-load shutdown can indicate inadequate power delivery. For the situation described—A small office PC blue-screens intermittently and a bootable memory diagnostic records reproducible address errors—this would not demonstrate the specified intervention. The relevant evidence is “Extended memory diagnostics run without bit errors.”.

D:

Lost firmware boot settings can hide a valid installed bootloader. For the situation described—A small office PC blue-screens intermittently and a bootable memory diagnostic records reproducible address errors—this would not demonstrate the specified intervention. The relevant evidence is “Extended memory diagnostics run without bit errors.”.

Question 451

A desktop has no video or keyboard response immediately after an unsupported CPU swap, while fans operate. Which action is MOST appropriate for this situation?

  1. Restore power at the outlet or circuit before opening the PC.
  2. Reconnect the chassis controls to the motherboard's documented headers.
  3. Restore a CPU supported by the motherboard socket and firmware.
  4. Replace the damaged motherboard rather than powering it repeatedly.

Explanation

Correct Answer

C:

An unsupported CPU can prevent initialization before display output. In this situation—A desktop has no video or keyboard response immediately after an unsupported CPU swap, while fans operate—the right response is “Restore a CPU supported by the motherboard socket and firmware.”. A confirming result would be “The board POSTs and identifies the supported processor.”.

Incorrect Answers

A:

Absence of mains power explains all loss of standby indicators. That does not directly address the condition described—A desktop has no video or keyboard response immediately after an unsupported CPU swap, while fans operate. “Restore a CPU supported by the motherboard socket and firmware.” is the appropriate response because an unsupported CPU can prevent initialization before display output.

B:

Miswired front-panel headers cause misleading power/reset behavior. That does not directly address the condition described—A desktop has no video or keyboard response immediately after an unsupported CPU swap, while fans operate. “Restore a CPU supported by the motherboard socket and firmware.” is the appropriate response because an unsupported CPU can prevent initialization before display output.

D:

Physically damaged capacitors indicate an electrical reliability fault. That does not directly address the condition described—A desktop has no video or keyboard response immediately after an unsupported CPU swap, while fans operate. “Restore a CPU supported by the motherboard socket and firmware.” is the appropriate response because an unsupported CPU can prevent initialization before display output.

Question 452

A desktop has no video or keyboard response immediately after an unsupported CPU swap, while fans operate. After the appropriate change, which observation BEST verifies the intended result?

  1. A known-good load works at the outlet and the PC then powers on.
  2. The board POSTs and identifies the supported processor.
  3. Power and reset switches perform their intended functions.
  4. POST completes with a known-good memory configuration.

Explanation

Correct Answer

B:

An unsupported CPU can prevent initialization before display output. The outcome “The board POSTs and identifies the supported processor.” verifies the action “Restore a CPU supported by the motherboard socket and firmware.” for this situation: A desktop has no video or keyboard response immediately after an unsupported CPU swap, while fans operate.

Incorrect Answers

A:

Absence of mains power explains all loss of standby indicators. For the situation described—A desktop has no video or keyboard response immediately after an unsupported CPU swap, while fans operate—this would not demonstrate the specified intervention. The relevant evidence is “The board POSTs and identifies the supported processor.”.

C:

Miswired front-panel headers cause misleading power/reset behavior. For the situation described—A desktop has no video or keyboard response immediately after an unsupported CPU swap, while fans operate—this would not demonstrate the specified intervention. The relevant evidence is “The board POSTs and identifies the supported processor.”.

D:

POST beep patterns can localize a failure to RAM before the OS loads. For the situation described—A desktop has no video or keyboard response immediately after an unsupported CPU swap, while fans operate—this would not demonstrate the specified intervention. The relevant evidence is “The board POSTs and identifies the supported processor.”.

Question 453

A laptop reaches firmware setup but cannot boot because all boot entries were reset after a firmware update. Which action is MOST appropriate for this situation?

  1. Restore a CPU supported by the motherboard socket and firmware.
  2. Restore the correct UEFI boot entry and mode for its existing installation.
  3. Repair cooling airflow and heatsink contact before more stress testing.
  4. Restore power at the outlet or circuit before opening the PC.

Explanation

Correct Answer

B:

Lost firmware boot settings can hide a valid installed bootloader. In this situation—A laptop reaches firmware setup but cannot boot because all boot entries were reset after a firmware update—the right response is “Restore the correct UEFI boot entry and mode for its existing installation.”. A confirming result would be “The existing OS boots without repartitioning the storage.”.

Incorrect Answers

A:

An unsupported CPU can prevent initialization before display output. That does not directly address the condition described—A laptop reaches firmware setup but cannot boot because all boot entries were reset after a firmware update. “Restore the correct UEFI boot entry and mode for its existing installation.” is the appropriate response because lost firmware boot settings can hide a valid installed bootloader.

C:

Thermal throttling and protection can reset a system under high heat. That does not directly address the condition described—A laptop reaches firmware setup but cannot boot because all boot entries were reset after a firmware update. “Restore the correct UEFI boot entry and mode for its existing installation.” is the appropriate response because lost firmware boot settings can hide a valid installed bootloader.

D:

Absence of mains power explains all loss of standby indicators. That does not directly address the condition described—A laptop reaches firmware setup but cannot boot because all boot entries were reset after a firmware update. “Restore the correct UEFI boot entry and mode for its existing installation.” is the appropriate response because lost firmware boot settings can hide a valid installed bootloader.

Question 454

A laptop reaches firmware setup but cannot boot because all boot entries were reset after a firmware update. After the appropriate change, which observation BEST verifies the intended result?

  1. Extended memory diagnostics run without bit errors.
  2. A representative GPU/CPU stress test completes without shutdown.
  3. The existing OS boots without repartitioning the storage.
  4. The system powers on without short-circuit protection tripping.

Explanation

Correct Answer

C:

Lost firmware boot settings can hide a valid installed bootloader. The outcome “The existing OS boots without repartitioning the storage.” verifies the action “Restore the correct UEFI boot entry and mode for its existing installation.” for this situation: A laptop reaches firmware setup but cannot boot because all boot entries were reset after a firmware update.

Incorrect Answers

A:

Reproducible RAM errors indicate faulty memory rather than disk capacity. For the situation described—A laptop reaches firmware setup but cannot boot because all boot entries were reset after a firmware update—this would not demonstrate the specified intervention. The relevant evidence is “The existing OS boots without repartitioning the storage.”.

B:

High-load shutdown can indicate inadequate power delivery. For the situation described—A laptop reaches firmware setup but cannot boot because all boot entries were reset after a firmware update—this would not demonstrate the specified intervention. The relevant evidence is “The existing OS boots without repartitioning the storage.”.

D:

A standoff touching the wrong board traces can short the chassis. For the situation described—A laptop reaches firmware setup but cannot boot because all boot entries were reset after a firmware update—this would not demonstrate the specified intervention. The relevant evidence is “The existing OS boots without repartitioning the storage.”.

Question 455

A PC randomly freezes under load and lint mats completely block intake vents. Which action is MOST appropriate for this situation?

  1. Repair cooling airflow and heatsink contact before more stress testing.
  2. Remove the extra standoff and correct the board mounting.
  3. Remove dust safely and restore unobstructed cooling airflow.
  4. Restore a CPU supported by the motherboard socket and firmware.

Explanation

Correct Answer

C:

Blocked airflow can raise chassis and component temperatures. In this situation—A PC randomly freezes under load and lint mats completely block intake vents—the right response is “Remove dust safely and restore unobstructed cooling airflow.”. A confirming result would be “Fan speeds and component temperature remain stable during load.”.

Incorrect Answers

A:

Thermal throttling and protection can reset a system under high heat. That does not directly address the condition described—A PC randomly freezes under load and lint mats completely block intake vents. “Remove dust safely and restore unobstructed cooling airflow.” is the appropriate response because blocked airflow can raise chassis and component temperatures.

B:

A standoff touching the wrong board traces can short the chassis. That does not directly address the condition described—A PC randomly freezes under load and lint mats completely block intake vents. “Remove dust safely and restore unobstructed cooling airflow.” is the appropriate response because blocked airflow can raise chassis and component temperatures.

D:

An unsupported CPU can prevent initialization before display output. That does not directly address the condition described—A PC randomly freezes under load and lint mats completely block intake vents. “Remove dust safely and restore unobstructed cooling airflow.” is the appropriate response because blocked airflow can raise chassis and component temperatures.

Question 456

A PC randomly freezes under load and lint mats completely block intake vents. After the appropriate change, which observation BEST verifies the intended result?

  1. A replacement board completes stable POST and load testing.
  2. Fan speeds and component temperature remain stable during load.
  3. Input voltage stays acceptable during appliance starts and the PC remains stable.
  4. POST succeeds with the installed discrete GPU under load.

Explanation

Correct Answer

B:

Blocked airflow can raise chassis and component temperatures. The outcome “Fan speeds and component temperature remain stable during load.” verifies the action “Remove dust safely and restore unobstructed cooling airflow.” for this situation: A PC randomly freezes under load and lint mats completely block intake vents.

Incorrect Answers

A:

Physically damaged capacitors indicate an electrical reliability fault. For the situation described—A PC randomly freezes under load and lint mats completely block intake vents—this would not demonstrate the specified intervention. The relevant evidence is “Fan speeds and component temperature remain stable during load.”.

C:

Brownouts interrupt stable input power even when internal components are healthy. For the situation described—A PC randomly freezes under load and lint mats completely block intake vents—this would not demonstrate the specified intervention. The relevant evidence is “Fan speeds and component temperature remain stable during load.”.

D:

Discrete graphics introduce expansion and power requirements absent from integrated video. For the situation described—A PC randomly freezes under load and lint mats completely block intake vents—this would not demonstrate the specified intervention. The relevant evidence is “Fan speeds and component temperature remain stable during load.”.

Question 457

A desktop's fans spin but the power-button front-panel header was connected to reset pins during assembly. Which action is MOST appropriate for this situation?

  1. Restore a CPU supported by the motherboard socket and firmware.
  2. Reconnect the chassis controls to the motherboard's documented headers.
  3. Replace the damaged motherboard rather than powering it repeatedly.
  4. Reseat and isolate memory modules using the board's diagnostic procedure.

Explanation

Correct Answer

B:

Miswired front-panel headers cause misleading power/reset behavior. In this situation—A desktop's fans spin but the power-button front-panel header was connected to reset pins during assembly—the right response is “Reconnect the chassis controls to the motherboard's documented headers.”. A confirming result would be “Power and reset switches perform their intended functions.”.

Incorrect Answers

A:

An unsupported CPU can prevent initialization before display output. That does not directly address the condition described—A desktop's fans spin but the power-button front-panel header was connected to reset pins during assembly. “Reconnect the chassis controls to the motherboard's documented headers.” is the appropriate response because miswired front-panel headers cause misleading power/reset behavior.

C:

Physically damaged capacitors indicate an electrical reliability fault. That does not directly address the condition described—A desktop's fans spin but the power-button front-panel header was connected to reset pins during assembly. “Reconnect the chassis controls to the motherboard's documented headers.” is the appropriate response because miswired front-panel headers cause misleading power/reset behavior.

D:

POST beep patterns can localize a failure to RAM before the OS loads. That does not directly address the condition described—A desktop's fans spin but the power-button front-panel header was connected to reset pins during assembly. “Reconnect the chassis controls to the motherboard's documented headers.” is the appropriate response because miswired front-panel headers cause misleading power/reset behavior.

Question 458

A desktop's fans spin but the power-button front-panel header was connected to reset pins during assembly. After the appropriate change, which observation BEST verifies the intended result?

  1. POST completes with a known-good memory configuration.
  2. A representative GPU/CPU stress test completes without shutdown.
  3. Power and reset switches perform their intended functions.
  4. A known-good load works at the outlet and the PC then powers on.

Explanation

Correct Answer

C:

Miswired front-panel headers cause misleading power/reset behavior. The outcome “Power and reset switches perform their intended functions.” verifies the action “Reconnect the chassis controls to the motherboard's documented headers.” for this situation: A desktop's fans spin but the power-button front-panel header was connected to reset pins during assembly.

Incorrect Answers

A:

POST beep patterns can localize a failure to RAM before the OS loads. For the situation described—A desktop's fans spin but the power-button front-panel header was connected to reset pins during assembly—this would not demonstrate the specified intervention. The relevant evidence is “Power and reset switches perform their intended functions.”.

B:

High-load shutdown can indicate inadequate power delivery. For the situation described—A desktop's fans spin but the power-button front-panel header was connected to reset pins during assembly—this would not demonstrate the specified intervention. The relevant evidence is “Power and reset switches perform their intended functions.”.

D:

Absence of mains power explains all loss of standby indicators. For the situation described—A desktop's fans spin but the power-button front-panel header was connected to reset pins during assembly—this would not demonstrate the specified intervention. The relevant evidence is “Power and reset switches perform their intended functions.”.

Question 459

A PC reports a CPU fan speed error although the cooler spins from a directly powered adapter. Which action is MOST appropriate for this situation?

  1. Connect the CPU cooling fan properly and confirm heat transfer.
  2. Connect fan tachometer/control to the correct motherboard header.
  3. Restore a CPU supported by the motherboard socket and firmware.
  4. Replace the damaged motherboard rather than powering it repeatedly.

Explanation

Correct Answer

B:

A fan powered externally can spin without reporting speed to firmware. In this situation—A PC reports a CPU fan speed error although the cooler spins from a directly powered adapter—the right response is “Connect fan tachometer/control to the correct motherboard header.”. A confirming result would be “Firmware reads a valid fan RPM and boot warning clears.”.

Incorrect Answers

A:

A disconnected cooler can cause rapid thermal protection. That does not directly address the condition described—A PC reports a CPU fan speed error although the cooler spins from a directly powered adapter. “Connect fan tachometer/control to the correct motherboard header.” is the appropriate response because a fan powered externally can spin without reporting speed to firmware.

C:

An unsupported CPU can prevent initialization before display output. That does not directly address the condition described—A PC reports a CPU fan speed error although the cooler spins from a directly powered adapter. “Connect fan tachometer/control to the correct motherboard header.” is the appropriate response because a fan powered externally can spin without reporting speed to firmware.

D:

Physically damaged capacitors indicate an electrical reliability fault. That does not directly address the condition described—A PC reports a CPU fan speed error although the cooler spins from a directly powered adapter. “Connect fan tachometer/control to the correct motherboard header.” is the appropriate response because a fan powered externally can spin without reporting speed to firmware.

Question 460

A PC reports a CPU fan speed error although the cooler spins from a directly powered adapter. After the appropriate change, which observation BEST verifies the intended result?

  1. POST completes and firmware detects the compatible RAM.
  2. Firmware reads a valid fan RPM and boot warning clears.
  3. The CPU fan spins and startup no longer triggers thermal shutdown.
  4. Firmware retains the clock and configuration across an overnight unplug.

Explanation

Correct Answer

B:

A fan powered externally can spin without reporting speed to firmware. The outcome “Firmware reads a valid fan RPM and boot warning clears.” verifies the action “Connect fan tachometer/control to the correct motherboard header.” for this situation: A PC reports a CPU fan speed error although the cooler spins from a directly powered adapter.

Incorrect Answers

A:

DDR generations are not physically/electrically interchangeable. For the situation described—A PC reports a CPU fan speed error although the cooler spins from a directly powered adapter—this would not demonstrate the specified intervention. The relevant evidence is “Firmware reads a valid fan RPM and boot warning clears.”.

C:

A disconnected cooler can cause rapid thermal protection. For the situation described—A PC reports a CPU fan speed error although the cooler spins from a directly powered adapter—this would not demonstrate the specified intervention. The relevant evidence is “Firmware reads a valid fan RPM and boot warning clears.”.

D:

The coin-cell battery preserves the real-time clock while unplugged. For the situation described—A PC reports a CPU fan speed error although the cooler spins from a directly powered adapter—this would not demonstrate the specified intervention. The relevant evidence is “Firmware reads a valid fan RPM and boot warning clears.”.