McAfee-Secured Website

Exam Bundle

Exam Code: 220-1201

Exam Name CompTIA A+ Certification Exam: Core 1

Certification Provider: CompTIA

Corresponding Certification: CompTIA A+

CompTIA 220-1201 Bundle $44.99

100% CompTIA 220-1201 Guaranteed Success With Testking Training Materials

Get Real 220-1201 Exam Questions & Expert Verified Answers as Experienced on the Real Exam!

  • Questions & Answers

    220-1201 Questions & Answers

    527 Questions & Answers

    The ultimate exam preparation tool, Questions & Answers mirrors the actual 220-1201 exam while allowing you to hone and measure every aspect of your test-taking ability.

  • 220-1201 Video Course

    220-1201 Video Course

    106 Video Lectures

    220-1201 Video Course is developed by CompTIA Professionals to help you pass the 220-1201 exam.

    Description

    This course will improve your knowledge and skills required to pass CompTIA A+ Certification Exam: Core 1 exam.
  • Study Guide

    220-1201 Study Guide

    2615 PDF Pages

    Developed by industry experts, this 2615-page guide spells out in painstaking detail all of the information you need to ace 220-1201 exam.

CompTIA A+ Certification Exam: Core 1 (220-1201) Practice Tests

Satisfaction Guaranteed

Money Back Guarantee

Testking provides hassle-free money back guarantee with our products. That is because we have 100% trust in the abilities of our professional and experience product team, and our record is a proof of that.

99.6% PASS RATE
Total Cost: $194.97
Bundle Price: $149.98

Purchase Individually

  • Questions & Answers

    Questions & Answers

    527 Questions

    $124.99
  • 220-1201 Video Course

    Video Course

    106 Video Lectures

    $39.99
  • Study Guide

    Study Guide

    2615 PDF Pages

    $29.99

CompTIA 220-1201 Practice Test 45

Question 440

An office PC reboots only during heavy video rendering and CPU package temperature reaches its limit. After the appropriate change, which observation BEST verifies the intended result?

  1. CPU temperature stays within spec throughout sustained rendering.
  2. Power and reset switches perform their intended functions.
  3. Fan speeds and component temperature remain stable during load.
  4. The board POSTs and identifies the supported processor.

Explanation

Correct Answer

A:

Thermal throttling and protection can reset a system under high heat. The outcome “CPU temperature stays within spec throughout sustained rendering.” verifies the action “Repair cooling airflow and heatsink contact before more stress testing.” for this situation: An office PC reboots only during heavy video rendering and CPU package temperature reaches its limit.

Incorrect Answers

B:

Miswired front-panel headers cause misleading power/reset behavior. For the situation described—An office PC reboots only during heavy video rendering and CPU package temperature reaches its limit—this would not demonstrate the specified intervention. The relevant evidence is “CPU temperature stays within spec throughout sustained rendering.”.

C:

Blocked airflow can raise chassis and component temperatures. For the situation described—An office PC reboots only during heavy video rendering and CPU package temperature reaches its limit—this would not demonstrate the specified intervention. The relevant evidence is “CPU temperature stays within spec throughout sustained rendering.”.

D:

An unsupported CPU can prevent initialization before display output. For the situation described—An office PC reboots only during heavy video rendering and CPU package temperature reaches its limit—this would not demonstrate the specified intervention. The relevant evidence is “CPU temperature stays within spec throughout sustained rendering.”.

Question 441

A gaming desktop shuts off as the graphics card draws peak power, but its idle load is stable. Which action is MOST appropriate for this situation?

  1. Reconnect the chassis controls to the motherboard's documented headers.
  2. Check GPU seating, PCIe power, and PSU capacity systematically.
  3. Restore power at the outlet or circuit before opening the PC.
  4. Test and replace an undersized or defective PSU as warranted.

Explanation

Correct Answer

D:

High-load shutdown can indicate inadequate power delivery. In this situation—A gaming desktop shuts off as the graphics card draws peak power, but its idle load is stable—the right response is “Test and replace an undersized or defective PSU as warranted.”. A confirming result would be “A representative GPU/CPU stress test completes without shutdown.”.

Incorrect Answers

A:

Miswired front-panel headers cause misleading power/reset behavior. That does not directly address the condition described—A gaming desktop shuts off as the graphics card draws peak power, but its idle load is stable. “Test and replace an undersized or defective PSU as warranted.” is the appropriate response because high-load shutdown can indicate inadequate power delivery.

B:

Discrete graphics introduce expansion and power requirements absent from integrated video. That does not directly address the condition described—A gaming desktop shuts off as the graphics card draws peak power, but its idle load is stable. “Test and replace an undersized or defective PSU as warranted.” is the appropriate response because high-load shutdown can indicate inadequate power delivery.

C:

Absence of mains power explains all loss of standby indicators. That does not directly address the condition described—A gaming desktop shuts off as the graphics card draws peak power, but its idle load is stable. “Test and replace an undersized or defective PSU as warranted.” is the appropriate response because high-load shutdown can indicate inadequate power delivery.

Question 442

A gaming desktop shuts off as the graphics card draws peak power, but its idle load is stable. After the appropriate change, which observation BEST verifies the intended result?

  1. A representative GPU/CPU stress test completes without shutdown.
  2. A replacement board completes stable POST and load testing.
  3. The CPU fan spins and startup no longer triggers thermal shutdown.
  4. The system powers on without short-circuit protection tripping.

Explanation

Correct Answer

A:

High-load shutdown can indicate inadequate power delivery. The outcome “A representative GPU/CPU stress test completes without shutdown.” verifies the action “Test and replace an undersized or defective PSU as warranted.” for this situation: A gaming desktop shuts off as the graphics card draws peak power, but its idle load is stable.

Incorrect Answers

B:

Physically damaged capacitors indicate an electrical reliability fault. For the situation described—A gaming desktop shuts off as the graphics card draws peak power, but its idle load is stable—this would not demonstrate the specified intervention. The relevant evidence is “A representative GPU/CPU stress test completes without shutdown.”.

C:

A disconnected cooler can cause rapid thermal protection. For the situation described—A gaming desktop shuts off as the graphics card draws peak power, but its idle load is stable—this would not demonstrate the specified intervention. The relevant evidence is “A representative GPU/CPU stress test completes without shutdown.”.

D:

A standoff touching the wrong board traces can short the chassis. For the situation described—A gaming desktop shuts off as the graphics card draws peak power, but its idle load is stable—this would not demonstrate the specified intervention. The relevant evidence is “A representative GPU/CPU stress test completes without shutdown.”.

Question 443

A technician sees two motherboard capacitors bulging and leaking near the CPU power stages. Which action is MOST appropriate for this situation?

  1. Reconnect the chassis controls to the motherboard's documented headers.
  2. Replace the damaged motherboard rather than powering it repeatedly.
  3. Remove the extra standoff and correct the board mounting.
  4. Restore a CPU supported by the motherboard socket and firmware.

Explanation

Correct Answer

B:

Physically damaged capacitors indicate an electrical reliability fault. In this situation—A technician sees two motherboard capacitors bulging and leaking near the CPU power stages—the right response is “Replace the damaged motherboard rather than powering it repeatedly.”. A confirming result would be “A replacement board completes stable POST and load testing.”.

Incorrect Answers

A:

Miswired front-panel headers cause misleading power/reset behavior. That does not directly address the condition described—A technician sees two motherboard capacitors bulging and leaking near the CPU power stages. “Replace the damaged motherboard rather than powering it repeatedly.” is the appropriate response because physically damaged capacitors indicate an electrical reliability fault.

C:

A standoff touching the wrong board traces can short the chassis. That does not directly address the condition described—A technician sees two motherboard capacitors bulging and leaking near the CPU power stages. “Replace the damaged motherboard rather than powering it repeatedly.” is the appropriate response because physically damaged capacitors indicate an electrical reliability fault.

D:

An unsupported CPU can prevent initialization before display output. That does not directly address the condition described—A technician sees two motherboard capacitors bulging and leaking near the CPU power stages. “Replace the damaged motherboard rather than powering it repeatedly.” is the appropriate response because physically damaged capacitors indicate an electrical reliability fault.

Question 444

A technician sees two motherboard capacitors bulging and leaking near the CPU power stages. After the appropriate change, which observation BEST verifies the intended result?

  1. POST completes and firmware detects the compatible RAM.
  2. A replacement board completes stable POST and load testing.
  3. A representative GPU/CPU stress test completes without shutdown.
  4. POST succeeds with the installed discrete GPU under load.

Explanation

Correct Answer

B:

Physically damaged capacitors indicate an electrical reliability fault. The outcome “A replacement board completes stable POST and load testing.” verifies the action “Replace the damaged motherboard rather than powering it repeatedly.” for this situation: A technician sees two motherboard capacitors bulging and leaking near the CPU power stages.

Incorrect Answers

A:

DDR generations are not physically/electrically interchangeable. For the situation described—A technician sees two motherboard capacitors bulging and leaking near the CPU power stages—this would not demonstrate the specified intervention. The relevant evidence is “A replacement board completes stable POST and load testing.”.

C:

High-load shutdown can indicate inadequate power delivery. For the situation described—A technician sees two motherboard capacitors bulging and leaking near the CPU power stages—this would not demonstrate the specified intervention. The relevant evidence is “A replacement board completes stable POST and load testing.”.

D:

Discrete graphics introduce expansion and power requirements absent from integrated video. For the situation described—A technician sees two motherboard capacitors bulging and leaking near the CPU power stages—this would not demonstrate the specified intervention. The relevant evidence is “A replacement board completes stable POST and load testing.”.

Question 445

A recently assembled PC will not POST and a DDR5 memory module is seated in a DDR4 board. Which action is MOST appropriate for this situation?

  1. Reseat and isolate memory modules using the board's diagnostic procedure.
  2. Replace the failing memory module identified through isolation.
  3. Remove the extra standoff and correct the board mounting.
  4. Install the correct generation memory supported by the board.

Explanation

Correct Answer

D:

DDR generations are not physically/electrically interchangeable. In this situation—A recently assembled PC will not POST and a DDR5 memory module is seated in a DDR4 board—the right response is “Install the correct generation memory supported by the board.”. A confirming result would be “POST completes and firmware detects the compatible RAM.”.

Incorrect Answers

A:

POST beep patterns can localize a failure to RAM before the OS loads. That does not directly address the condition described—A recently assembled PC will not POST and a DDR5 memory module is seated in a DDR4 board. “Install the correct generation memory supported by the board.” is the appropriate response because dDR generations are not physically/electrically interchangeable.

B:

Reproducible RAM errors indicate faulty memory rather than disk capacity. That does not directly address the condition described—A recently assembled PC will not POST and a DDR5 memory module is seated in a DDR4 board. “Install the correct generation memory supported by the board.” is the appropriate response because dDR generations are not physically/electrically interchangeable.

C:

A standoff touching the wrong board traces can short the chassis. That does not directly address the condition described—A recently assembled PC will not POST and a DDR5 memory module is seated in a DDR4 board. “Install the correct generation memory supported by the board.” is the appropriate response because dDR generations are not physically/electrically interchangeable.

Question 446

A recently assembled PC will not POST and a DDR5 memory module is seated in a DDR4 board. After the appropriate change, which observation BEST verifies the intended result?

  1. POST completes and firmware detects the compatible RAM.
  2. The board POSTs and identifies the supported processor.
  3. Power and reset switches perform their intended functions.
  4. POST succeeds with the installed discrete GPU under load.

Explanation

Correct Answer

A:

DDR generations are not physically/electrically interchangeable. The outcome “POST completes and firmware detects the compatible RAM.” verifies the action “Install the correct generation memory supported by the board.” for this situation: A recently assembled PC will not POST and a DDR5 memory module is seated in a DDR4 board.

Incorrect Answers

B:

An unsupported CPU can prevent initialization before display output. For the situation described—A recently assembled PC will not POST and a DDR5 memory module is seated in a DDR4 board—this would not demonstrate the specified intervention. The relevant evidence is “POST completes and firmware detects the compatible RAM.”.

C:

Miswired front-panel headers cause misleading power/reset behavior. For the situation described—A recently assembled PC will not POST and a DDR5 memory module is seated in a DDR4 board—this would not demonstrate the specified intervention. The relevant evidence is “POST completes and firmware detects the compatible RAM.”.

D:

Discrete graphics introduce expansion and power requirements absent from integrated video. For the situation described—A recently assembled PC will not POST and a DDR5 memory module is seated in a DDR4 board—this would not demonstrate the specified intervention. The relevant evidence is “POST completes and firmware detects the compatible RAM.”.

Question 447

A new desktop repeatedly powers on then turns off because the CPU cooler fan is disconnected. Which action is MOST appropriate for this situation?

  1. Connect fan tachometer/control to the correct motherboard header.
  2. Repair cooling airflow and heatsink contact before more stress testing.
  3. Restore a CPU supported by the motherboard socket and firmware.
  4. Connect the CPU cooling fan properly and confirm heat transfer.

Explanation

Correct Answer

D:

A disconnected cooler can cause rapid thermal protection. In this situation—A new desktop repeatedly powers on then turns off because the CPU cooler fan is disconnected—the right response is “Connect the CPU cooling fan properly and confirm heat transfer.”. A confirming result would be “The CPU fan spins and startup no longer triggers thermal shutdown.”.

Incorrect Answers

A:

A fan powered externally can spin without reporting speed to firmware. That does not directly address the condition described—A new desktop repeatedly powers on then turns off because the CPU cooler fan is disconnected. “Connect the CPU cooling fan properly and confirm heat transfer.” is the appropriate response because a disconnected cooler can cause rapid thermal protection.

B:

Thermal throttling and protection can reset a system under high heat. That does not directly address the condition described—A new desktop repeatedly powers on then turns off because the CPU cooler fan is disconnected. “Connect the CPU cooling fan properly and confirm heat transfer.” is the appropriate response because a disconnected cooler can cause rapid thermal protection.

C:

An unsupported CPU can prevent initialization before display output. That does not directly address the condition described—A new desktop repeatedly powers on then turns off because the CPU cooler fan is disconnected. “Connect the CPU cooling fan properly and confirm heat transfer.” is the appropriate response because a disconnected cooler can cause rapid thermal protection.

Question 448

A new desktop repeatedly powers on then turns off because the CPU cooler fan is disconnected. After the appropriate change, which observation BEST verifies the intended result?

  1. A representative GPU/CPU stress test completes without shutdown.
  2. The CPU fan spins and startup no longer triggers thermal shutdown.
  3. Power and reset switches perform their intended functions.
  4. Firmware reads a valid fan RPM and boot warning clears.

Explanation

Correct Answer

B:

A disconnected cooler can cause rapid thermal protection. The outcome “The CPU fan spins and startup no longer triggers thermal shutdown.” verifies the action “Connect the CPU cooling fan properly and confirm heat transfer.” for this situation: A new desktop repeatedly powers on then turns off because the CPU cooler fan is disconnected.

Incorrect Answers

A:

High-load shutdown can indicate inadequate power delivery. For the situation described—A new desktop repeatedly powers on then turns off because the CPU cooler fan is disconnected—this would not demonstrate the specified intervention. The relevant evidence is “The CPU fan spins and startup no longer triggers thermal shutdown.”.

C:

Miswired front-panel headers cause misleading power/reset behavior. For the situation described—A new desktop repeatedly powers on then turns off because the CPU cooler fan is disconnected—this would not demonstrate the specified intervention. The relevant evidence is “The CPU fan spins and startup no longer triggers thermal shutdown.”.

D:

A fan powered externally can spin without reporting speed to firmware. For the situation described—A new desktop repeatedly powers on then turns off because the CPU cooler fan is disconnected—this would not demonstrate the specified intervention. The relevant evidence is “The CPU fan spins and startup no longer triggers thermal shutdown.”.

Question 449

A small office PC blue-screens intermittently and a bootable memory diagnostic records reproducible address errors. Which action is MOST appropriate for this situation?

  1. Install the correct generation memory supported by the board.
  2. Reseat and isolate memory modules using the board's diagnostic procedure.
  3. Repair cooling airflow and heatsink contact before more stress testing.
  4. Replace the failing memory module identified through isolation.

Explanation

Correct Answer

D:

Reproducible RAM errors indicate faulty memory rather than disk capacity. In this situation—A small office PC blue-screens intermittently and a bootable memory diagnostic records reproducible address errors—the right response is “Replace the failing memory module identified through isolation.”. A confirming result would be “Extended memory diagnostics run without bit errors.”.

Incorrect Answers

A:

DDR generations are not physically/electrically interchangeable. That does not directly address the condition described—A small office PC blue-screens intermittently and a bootable memory diagnostic records reproducible address errors. “Replace the failing memory module identified through isolation.” is the appropriate response because reproducible RAM errors indicate faulty memory rather than disk capacity.

B:

POST beep patterns can localize a failure to RAM before the OS loads. That does not directly address the condition described—A small office PC blue-screens intermittently and a bootable memory diagnostic records reproducible address errors. “Replace the failing memory module identified through isolation.” is the appropriate response because reproducible RAM errors indicate faulty memory rather than disk capacity.

C:

Thermal throttling and protection can reset a system under high heat. That does not directly address the condition described—A small office PC blue-screens intermittently and a bootable memory diagnostic records reproducible address errors. “Replace the failing memory module identified through isolation.” is the appropriate response because reproducible RAM errors indicate faulty memory rather than disk capacity.

Question 450

A small office PC blue-screens intermittently and a bootable memory diagnostic records reproducible address errors. After the appropriate change, which observation BEST verifies the intended result?

  1. POST completes with a known-good memory configuration.
  2. A representative GPU/CPU stress test completes without shutdown.
  3. Extended memory diagnostics run without bit errors.
  4. The existing OS boots without repartitioning the storage.

Explanation

Correct Answer

C:

Reproducible RAM errors indicate faulty memory rather than disk capacity. The outcome “Extended memory diagnostics run without bit errors.” verifies the action “Replace the failing memory module identified through isolation.” for this situation: A small office PC blue-screens intermittently and a bootable memory diagnostic records reproducible address errors.

Incorrect Answers

A:

POST beep patterns can localize a failure to RAM before the OS loads. For the situation described—A small office PC blue-screens intermittently and a bootable memory diagnostic records reproducible address errors—this would not demonstrate the specified intervention. The relevant evidence is “Extended memory diagnostics run without bit errors.”.

B:

High-load shutdown can indicate inadequate power delivery. For the situation described—A small office PC blue-screens intermittently and a bootable memory diagnostic records reproducible address errors—this would not demonstrate the specified intervention. The relevant evidence is “Extended memory diagnostics run without bit errors.”.

D:

Lost firmware boot settings can hide a valid installed bootloader. For the situation described—A small office PC blue-screens intermittently and a bootable memory diagnostic records reproducible address errors—this would not demonstrate the specified intervention. The relevant evidence is “Extended memory diagnostics run without bit errors.”.