McAfee-Secured Website

Exam Bundle

Exam Code: 220-1201

Exam Name CompTIA A+ Certification Exam: Core 1

Certification Provider: CompTIA

Corresponding Certification: CompTIA A+

CompTIA 220-1201 Bundle $44.99

100% CompTIA 220-1201 Guaranteed Success With Testking Training Materials

Get Real 220-1201 Exam Questions & Expert Verified Answers as Experienced on the Real Exam!

  • Questions & Answers

    220-1201 Questions & Answers

    527 Questions & Answers

    The ultimate exam preparation tool, Questions & Answers mirrors the actual 220-1201 exam while allowing you to hone and measure every aspect of your test-taking ability.

  • 220-1201 Video Course

    220-1201 Video Course

    106 Video Lectures

    220-1201 Video Course is developed by CompTIA Professionals to help you pass the 220-1201 exam.

    Description

    This course will improve your knowledge and skills required to pass CompTIA A+ Certification Exam: Core 1 exam.
  • Study Guide

    220-1201 Study Guide

    2615 PDF Pages

    Developed by industry experts, this 2615-page guide spells out in painstaking detail all of the information you need to ace 220-1201 exam.

CompTIA A+ Certification Exam: Core 1 (220-1201) Practice Tests

Satisfaction Guaranteed

Money Back Guarantee

Testking provides hassle-free money back guarantee with our products. That is because we have 100% trust in the abilities of our professional and experience product team, and our record is a proof of that.

99.6% PASS RATE
Total Cost: $194.97
Bundle Price: $149.98

Purchase Individually

  • Questions & Answers

    Questions & Answers

    527 Questions

    $124.99
  • 220-1201 Video Course

    Video Course

    106 Video Lectures

    $39.99
  • Study Guide

    Study Guide

    2615 PDF Pages

    $29.99

CompTIA 220-1201 Practice Test 44

Question 430

A business prefers predictable CPU performance and data isolation from unrelated tenants. After the appropriate change, which observation BEST verifies the intended result?

  1. Resources provision from the public provider's service catalog.
  2. Provider metadata confirms the intended host tenancy setting.
  3. The team can administer the guest OS while the cloud provider runs the hardware.
  4. The estimate separately includes outbound transfer volume and rate.

Explanation

Correct Answer

B:

Multitenancy shares provider infrastructure; dedicated options increase isolation. The outcome “Provider metadata confirms the intended host tenancy setting.” verifies the action “Evaluate dedicated-tenancy compute or reserved hosts where supported.” for this situation: A business prefers predictable CPU performance and data isolation from unrelated tenants.

Incorrect Answers

A:

Public clouds serve multiple customer organizations on provider infrastructure. For the situation described—A business prefers predictable CPU performance and data isolation from unrelated tenants—this would not demonstrate the specified intervention. The relevant evidence is “Provider metadata confirms the intended host tenancy setting.”.

C:

IaaS provides compute infrastructure while tenants manage guest systems. For the situation described—A business prefers predictable CPU performance and data isolation from unrelated tenants—this would not demonstrate the specified intervention. The relevant evidence is “Provider metadata confirms the intended host tenancy setting.”.

D:

Cloud ingress and egress can have different billing policies. For the situation described—A business prefers predictable CPU performance and data isolation from unrelated tenants—this would not demonstrate the specified intervention. The relevant evidence is “Provider metadata confirms the intended host tenancy setting.”.

Question 431

A team shares a single cloud subscription among departments and wants cost accountability. Which action is MOST appropriate for this situation?

  1. Use elastic cloud resources that can be expanded and released.
  2. Tag resources consistently and collect chargeback usage reports.
  3. Enable authorized cloud file synchronization with offline caching.
  4. Account for outbound data-transfer or egress charges in the design.

Explanation

Correct Answer

B:

Resource tagging attributes metered consumption to responsible cost centers. In this situation—A team shares a single cloud subscription among departments and wants cost accountability—the right response is “Tag resources consistently and collect chargeback usage reports.”. A confirming result would be “Monthly reports distinguish consumption per department.”.

Incorrect Answers

A:

Elasticity matches resource capacity to changing demand. That does not directly address the condition described—A team shares a single cloud subscription among departments and wants cost accountability. “Tag resources consistently and collect chargeback usage reports.” is the appropriate response because resource tagging attributes metered consumption to responsible cost centers.

C:

Cloud sync replicates approved changes and handles intermittent client connectivity. That does not directly address the condition described—A team shares a single cloud subscription among departments and wants cost accountability. “Tag resources consistently and collect chargeback usage reports.” is the appropriate response because resource tagging attributes metered consumption to responsible cost centers.

D:

Cloud ingress and egress can have different billing policies. That does not directly address the condition described—A team shares a single cloud subscription among departments and wants cost accountability. “Tag resources consistently and collect chargeback usage reports.” is the appropriate response because resource tagging attributes metered consumption to responsible cost centers.

Question 432

A team shares a single cloud subscription among departments and wants cost accountability. After the appropriate change, which observation BEST verifies the intended result?

  1. An edited test file reconciles correctly when connectivity resumes.
  2. A zone isolation test preserves service within target recovery bounds.
  3. Monthly reports distinguish consumption per department.
  4. The estimate separately includes outbound transfer volume and rate.

Explanation

Correct Answer

C:

Resource tagging attributes metered consumption to responsible cost centers. The outcome “Monthly reports distinguish consumption per department.” verifies the action “Tag resources consistently and collect chargeback usage reports.” for this situation: A team shares a single cloud subscription among departments and wants cost accountability.

Incorrect Answers

A:

Cloud sync replicates approved changes and handles intermittent client connectivity. For the situation described—A team shares a single cloud subscription among departments and wants cost accountability—this would not demonstrate the specified intervention. The relevant evidence is “Monthly reports distinguish consumption per department.”.

B:

Availability zones supply separate fault domains within a cloud region. For the situation described—A team shares a single cloud subscription among departments and wants cost accountability—this would not demonstrate the specified intervention. The relevant evidence is “Monthly reports distinguish consumption per department.”.

D:

Cloud ingress and egress can have different billing policies. For the situation described—A team shares a single cloud subscription among departments and wants cost accountability—this would not demonstrate the specified intervention. The relevant evidence is “Monthly reports distinguish consumption per department.”.

Question 433

A tower desktop is entirely dead after a move: no LEDs or fans, and the outlet also fails a lamp test. Which action is MOST appropriate for this situation?

  1. Restore a CPU supported by the motherboard socket and firmware.
  2. Restore power at the outlet or circuit before opening the PC.
  3. Check GPU seating, PCIe power, and PSU capacity systematically.
  4. Reconnect the chassis controls to the motherboard's documented headers.

Explanation

Correct Answer

B:

Absence of mains power explains all loss of standby indicators. In this situation—A tower desktop is entirely dead after a move: no LEDs or fans, and the outlet also fails a lamp test—the right response is “Restore power at the outlet or circuit before opening the PC.”. A confirming result would be “A known-good load works at the outlet and the PC then powers on.”.

Incorrect Answers

A:

An unsupported CPU can prevent initialization before display output. That does not directly address the condition described—A tower desktop is entirely dead after a move: no LEDs or fans, and the outlet also fails a lamp test. “Restore power at the outlet or circuit before opening the PC.” is the appropriate response because absence of mains power explains all loss of standby indicators.

C:

Discrete graphics introduce expansion and power requirements absent from integrated video. That does not directly address the condition described—A tower desktop is entirely dead after a move: no LEDs or fans, and the outlet also fails a lamp test. “Restore power at the outlet or circuit before opening the PC.” is the appropriate response because absence of mains power explains all loss of standby indicators.

D:

Miswired front-panel headers cause misleading power/reset behavior. That does not directly address the condition described—A tower desktop is entirely dead after a move: no LEDs or fans, and the outlet also fails a lamp test. “Restore power at the outlet or circuit before opening the PC.” is the appropriate response because absence of mains power explains all loss of standby indicators.

Question 434

A tower desktop is entirely dead after a move: no LEDs or fans, and the outlet also fails a lamp test. After the appropriate change, which observation BEST verifies the intended result?

  1. A known-good load works at the outlet and the PC then powers on.
  2. POST succeeds with the installed discrete GPU under load.
  3. POST completes with a known-good memory configuration.
  4. The board POSTs and identifies the supported processor.

Explanation

Correct Answer

A:

Absence of mains power explains all loss of standby indicators. The outcome “A known-good load works at the outlet and the PC then powers on.” verifies the action “Restore power at the outlet or circuit before opening the PC.” for this situation: A tower desktop is entirely dead after a move: no LEDs or fans, and the outlet also fails a lamp test.

Incorrect Answers

B:

Discrete graphics introduce expansion and power requirements absent from integrated video. For the situation described—A tower desktop is entirely dead after a move: no LEDs or fans, and the outlet also fails a lamp test—this would not demonstrate the specified intervention. The relevant evidence is “A known-good load works at the outlet and the PC then powers on.”.

C:

POST beep patterns can localize a failure to RAM before the OS loads. For the situation described—A tower desktop is entirely dead after a move: no LEDs or fans, and the outlet also fails a lamp test—this would not demonstrate the specified intervention. The relevant evidence is “A known-good load works at the outlet and the PC then powers on.”.

D:

An unsupported CPU can prevent initialization before display output. For the situation described—A tower desktop is entirely dead after a move: no LEDs or fans, and the outlet also fails a lamp test—this would not demonstrate the specified intervention. The relevant evidence is “A known-good load works at the outlet and the PC then powers on.”.

Question 435

A workstation fans spin but POST halts on a repeating RAM diagnostic beep. Which action is MOST appropriate for this situation?

  1. Install the correct generation memory supported by the board.
  2. Check GPU seating, PCIe power, and PSU capacity systematically.
  3. Replace the failing memory module identified through isolation.
  4. Reseat and isolate memory modules using the board's diagnostic procedure.

Explanation

Correct Answer

D:

POST beep patterns can localize a failure to RAM before the OS loads. In this situation—A workstation fans spin but POST halts on a repeating RAM diagnostic beep—the right response is “Reseat and isolate memory modules using the board's diagnostic procedure.”. A confirming result would be “POST completes with a known-good memory configuration.”.

Incorrect Answers

A:

DDR generations are not physically/electrically interchangeable. That does not directly address the condition described—A workstation fans spin but POST halts on a repeating RAM diagnostic beep. “Reseat and isolate memory modules using the board's diagnostic procedure.” is the appropriate response because pOST beep patterns can localize a failure to RAM before the OS loads.

B:

Discrete graphics introduce expansion and power requirements absent from integrated video. That does not directly address the condition described—A workstation fans spin but POST halts on a repeating RAM diagnostic beep. “Reseat and isolate memory modules using the board's diagnostic procedure.” is the appropriate response because pOST beep patterns can localize a failure to RAM before the OS loads.

C:

Reproducible RAM errors indicate faulty memory rather than disk capacity. That does not directly address the condition described—A workstation fans spin but POST halts on a repeating RAM diagnostic beep. “Reseat and isolate memory modules using the board's diagnostic procedure.” is the appropriate response because pOST beep patterns can localize a failure to RAM before the OS loads.

Question 436

A workstation fans spin but POST halts on a repeating RAM diagnostic beep. After the appropriate change, which observation BEST verifies the intended result?

  1. Firmware reads a valid fan RPM and boot warning clears.
  2. The board POSTs and identifies the supported processor.
  3. Power and reset switches perform their intended functions.
  4. POST completes with a known-good memory configuration.

Explanation

Correct Answer

D:

POST beep patterns can localize a failure to RAM before the OS loads. The outcome “POST completes with a known-good memory configuration.” verifies the action “Reseat and isolate memory modules using the board's diagnostic procedure.” for this situation: A workstation fans spin but POST halts on a repeating RAM diagnostic beep.

Incorrect Answers

A:

A fan powered externally can spin without reporting speed to firmware. For the situation described—A workstation fans spin but POST halts on a repeating RAM diagnostic beep—this would not demonstrate the specified intervention. The relevant evidence is “POST completes with a known-good memory configuration.”.

B:

An unsupported CPU can prevent initialization before display output. For the situation described—A workstation fans spin but POST halts on a repeating RAM diagnostic beep—this would not demonstrate the specified intervention. The relevant evidence is “POST completes with a known-good memory configuration.”.

C:

Miswired front-panel headers cause misleading power/reset behavior. For the situation described—A workstation fans spin but POST halts on a repeating RAM diagnostic beep—this would not demonstrate the specified intervention. The relevant evidence is “POST completes with a known-good memory configuration.”.

Question 437

A PC loses date and time after each extended unplugged interval while otherwise booting normally. Which action is MOST appropriate for this situation?

  1. Remove the extra standoff and correct the board mounting.
  2. Install the correct generation memory supported by the board.
  3. Replace the depleted CMOS/RTC battery following board guidance.
  4. Reseat and isolate memory modules using the board's diagnostic procedure.

Explanation

Correct Answer

C:

The coin-cell battery preserves the real-time clock while unplugged. In this situation—A PC loses date and time after each extended unplugged interval while otherwise booting normally—the right response is “Replace the depleted CMOS/RTC battery following board guidance.”. A confirming result would be “Firmware retains the clock and configuration across an overnight unplug.”.

Incorrect Answers

A:

A standoff touching the wrong board traces can short the chassis. That does not directly address the condition described—A PC loses date and time after each extended unplugged interval while otherwise booting normally. “Replace the depleted CMOS/RTC battery following board guidance.” is the appropriate response because the coin-cell battery preserves the real-time clock while unplugged.

B:

DDR generations are not physically/electrically interchangeable. That does not directly address the condition described—A PC loses date and time after each extended unplugged interval while otherwise booting normally. “Replace the depleted CMOS/RTC battery following board guidance.” is the appropriate response because the coin-cell battery preserves the real-time clock while unplugged.

D:

POST beep patterns can localize a failure to RAM before the OS loads. That does not directly address the condition described—A PC loses date and time after each extended unplugged interval while otherwise booting normally. “Replace the depleted CMOS/RTC battery following board guidance.” is the appropriate response because the coin-cell battery preserves the real-time clock while unplugged.

Question 438

A PC loses date and time after each extended unplugged interval while otherwise booting normally. After the appropriate change, which observation BEST verifies the intended result?

  1. The system powers on without short-circuit protection tripping.
  2. POST completes and firmware detects the compatible RAM.
  3. POST completes with a known-good memory configuration.
  4. Firmware retains the clock and configuration across an overnight unplug.

Explanation

Correct Answer

D:

The coin-cell battery preserves the real-time clock while unplugged. The outcome “Firmware retains the clock and configuration across an overnight unplug.” verifies the action “Replace the depleted CMOS/RTC battery following board guidance.” for this situation: A PC loses date and time after each extended unplugged interval while otherwise booting normally.

Incorrect Answers

A:

A standoff touching the wrong board traces can short the chassis. For the situation described—A PC loses date and time after each extended unplugged interval while otherwise booting normally—this would not demonstrate the specified intervention. The relevant evidence is “Firmware retains the clock and configuration across an overnight unplug.”.

B:

DDR generations are not physically/electrically interchangeable. For the situation described—A PC loses date and time after each extended unplugged interval while otherwise booting normally—this would not demonstrate the specified intervention. The relevant evidence is “Firmware retains the clock and configuration across an overnight unplug.”.

C:

POST beep patterns can localize a failure to RAM before the OS loads. For the situation described—A PC loses date and time after each extended unplugged interval while otherwise booting normally—this would not demonstrate the specified intervention. The relevant evidence is “Firmware retains the clock and configuration across an overnight unplug.”.

Question 439

An office PC reboots only during heavy video rendering and CPU package temperature reaches its limit. Which action is MOST appropriate for this situation?

  1. Remove dust safely and restore unobstructed cooling airflow.
  2. Connect the CPU cooling fan properly and confirm heat transfer.
  3. Repair cooling airflow and heatsink contact before more stress testing.
  4. Reconnect the chassis controls to the motherboard's documented headers.

Explanation

Correct Answer

C:

Thermal throttling and protection can reset a system under high heat. In this situation—An office PC reboots only during heavy video rendering and CPU package temperature reaches its limit—the right response is “Repair cooling airflow and heatsink contact before more stress testing.”. A confirming result would be “CPU temperature stays within spec throughout sustained rendering.”.

Incorrect Answers

A:

Blocked airflow can raise chassis and component temperatures. That does not directly address the condition described—An office PC reboots only during heavy video rendering and CPU package temperature reaches its limit. “Repair cooling airflow and heatsink contact before more stress testing.” is the appropriate response because thermal throttling and protection can reset a system under high heat.

B:

A disconnected cooler can cause rapid thermal protection. That does not directly address the condition described—An office PC reboots only during heavy video rendering and CPU package temperature reaches its limit. “Repair cooling airflow and heatsink contact before more stress testing.” is the appropriate response because thermal throttling and protection can reset a system under high heat.

D:

Miswired front-panel headers cause misleading power/reset behavior. That does not directly address the condition described—An office PC reboots only during heavy video rendering and CPU package temperature reaches its limit. “Repair cooling airflow and heatsink contact before more stress testing.” is the appropriate response because thermal throttling and protection can reset a system under high heat.

Question 440

An office PC reboots only during heavy video rendering and CPU package temperature reaches its limit. After the appropriate change, which observation BEST verifies the intended result?

  1. CPU temperature stays within spec throughout sustained rendering.
  2. Power and reset switches perform their intended functions.
  3. Fan speeds and component temperature remain stable during load.
  4. The board POSTs and identifies the supported processor.

Explanation

Correct Answer

A:

Thermal throttling and protection can reset a system under high heat. The outcome “CPU temperature stays within spec throughout sustained rendering.” verifies the action “Repair cooling airflow and heatsink contact before more stress testing.” for this situation: An office PC reboots only during heavy video rendering and CPU package temperature reaches its limit.

Incorrect Answers

B:

Miswired front-panel headers cause misleading power/reset behavior. For the situation described—An office PC reboots only during heavy video rendering and CPU package temperature reaches its limit—this would not demonstrate the specified intervention. The relevant evidence is “CPU temperature stays within spec throughout sustained rendering.”.

C:

Blocked airflow can raise chassis and component temperatures. For the situation described—An office PC reboots only during heavy video rendering and CPU package temperature reaches its limit—this would not demonstrate the specified intervention. The relevant evidence is “CPU temperature stays within spec throughout sustained rendering.”.

D:

An unsupported CPU can prevent initialization before display output. For the situation described—An office PC reboots only during heavy video rendering and CPU package temperature reaches its limit—this would not demonstrate the specified intervention. The relevant evidence is “CPU temperature stays within spec throughout sustained rendering.”.