McAfee-Secured Website

Exam Bundle

Exam Code: 2V0-17.25

Exam Name VMware Cloud Foundation 9.0 Administrator

Certification Provider: VMware

Corresponding Certification: VCP-VCF Administrator

VMware 2V0-17.25 Bundle $19.99

100% VMware 2V0-17.25 Guaranteed Success With Testking Training Materials

Get Real 2V0-17.25 Exam Questions & Expert Verified Answers as Experienced on the Real Exam!

  • Questions & Answers

    2V0-17.25 Questions & Answers

    100 Questions & Answers

    The ultimate exam preparation tool, Questions & Answers mirrors the actual 2V0-17.25 exam while allowing you to hone and measure every aspect of your test-taking ability.

  • Study Guide

    2V0-17.25 Study Guide

    121 PDF Pages

    Developed by industry experts, this 121-page guide spells out in painstaking detail all of the information you need to ace 2V0-17.25 exam.

VMware Cloud Foundation 9.0 Administrator (2V0-17.25) Practice Tests

Satisfaction Guaranteed

Money Back Guarantee

Testking provides hassle-free money back guarantee with our products. That is because we have 100% trust in the abilities of our professional and experience product team, and our record is a proof of that.

99.6% PASS RATE
Total Cost: $154.98
Bundle Price: $134.99

Purchase Individually

  • Questions & Answers

    Questions & Answers

    100 Questions

    $124.99
  • Study Guide

    Study Guide

    121 PDF Pages

    $29.99

VMware 2V0-17.25 Practice Test 9

Question 80

Scenario: A company has an existing supported vSAN OSA cluster and wants to know whether ESA can be enabled simply by toggling a storage policy. Which observation would demonstrate that the requirement is satisfied?

  1. The same OSA cache disk groups remain while a VM policy says ESA
  2. A vCenter inventory label changes while storage health still reports OSA
  3. VM performance improves briefly but no architecture migration was performed
  4. The destination architecture is verified as ESA with compatible hardware and migrated objects

Explanation

Correct Answer

D:

That demonstrates a real transition rather than a policy-only label change.

Incorrect Answers

A:

An invented policy name is not a valid architecture conversion.

B:

Inventory labeling cannot establish an underlying storage data-path change.

C:

A performance sample does not show an OSA-to-ESA conversion.

Question 81

Scenario: A storage team is designing a fresh cluster and must choose between a traditional cache-tier disk-group model and an ESA-compatible unified device model. What is the most defensible next step for the VCF administrator?

  1. Select the newest storage mode without checking controller and network requirements
  2. Compare OSA disk-group requirements with ESA device architecture against certified hardware
  3. Assume ESA always requires a dedicated OSA-style cache SSD for each disk group
  4. Build an OSA disk group out of one shared capacity disk with no supported cache device

Explanation

Correct Answer

B:

The deployment choice determines how storage devices are organized and supported.

Incorrect Answers

A:

A version label does not supersede VMware's hardware compatibility guidance.

C:

That incorrectly imposes the traditional OSA device model on ESA.

D:

A traditional OSA configuration requires a valid cache and capacity layout.

Question 82

Scenario: A storage team is designing a fresh cluster and must choose between a traditional cache-tier disk-group model and an ESA-compatible unified device model. During acceptance testing, what result should the team require?

  1. The chosen cluster shows the correct disk inventory model and healthy supported storage objects
  2. An ESA design still depends on misconfigured OSA cache disk-group mappings
  3. The deployment wizard completes but the vSAN datastore remains unavailable
  4. Compatibility checks report unsupported storage hardware after the cluster is built

Explanation

Correct Answer

A:

It validates compatibility and operational data path for the selected architecture.

Incorrect Answers

B:

That is not evidence of the intended ESA layout.

C:

Wizard completion is not a valid end-to-end storage result.

D:

An unhealthy unsupported configuration cannot be considered successful.

Question 83

Scenario: A VCF architect must optimize new high-performance all-flash virtual machine storage while keeping clear policy and failure behavior. Which configuration change best resolves this problem?

  1. Evaluate vSAN ESA with policy-based protection and tested performance on approved nodes
  2. Remove all redundancy to maximize usable capacity despite production RPO requirements
  3. Bypass storage-policy testing because all-flash media is assumed to be inherently resilient
  4. Use an old unvalidated storage controller just to minimize initial hardware cost

Explanation

Correct Answer

A:

ESA is a plausible all-flash architecture when validated on certified equipment and expected workloads.

Incorrect Answers

B:

Capacity improvement cannot justify loss of required availability.

C:

Flash does not eliminate failure-domain or policy-compliance requirements.

D:

An unsupported controller can undermine the storage architecture and operations.

Question 84

Scenario: A VCF architect must optimize new high-performance all-flash virtual machine storage while keeping clear policy and failure behavior. What evidence distinguishes a successful change from a misleading green status?

  1. A single host fails and protected VM storage objects become inaccessible
  2. Load and fault tests meet the database SLO with policy-compliant ESA objects
  3. The cluster passes a device count check but cannot satisfy its placement policy
  4. A benchmark is fast only after disabling the required failures-to-tolerate setting

Explanation

Correct Answer

B:

Measured data-path behavior and protection establish the architecture's fitness.

Incorrect Answers

A:

A violated fault-tolerance requirement disproves the intended design.

C:

Inventory quantity alone does not demonstrate storage-object resilience.

D:

Performance at insufficient protection does not meet the design.

Question 85

Scenario: An administrator is troubleshooting a mixed estate where one vSAN cluster uses OSA and another uses ESA; the same storage warning cannot be interpreted identically. How should the platform team proceed?

  1. Apply an OSA cache disk-group replacement runbook to ESA without verification
  2. Identify each cluster's storage architecture before selecting diagnostics and remediation
  3. Assume any vSAN warning has an identical cause on all architectures and versions
  4. Ignore current compatibility and health reports because both clusters appear under vCenter

Explanation

Correct Answer

B:

Disk-group topology and policy capabilities differ between the two architectures.

Incorrect Answers

A:

Architecture-specific recovery operations should not be blindly reused across incompatible layouts.

C:

Different implementations require matching diagnostics to the affected subsystem.

D:

Central inventory does not imply identical underlying storage behavior.

Question 86

Scenario: An administrator is troubleshooting a mixed estate where one vSAN cluster uses OSA and another uses ESA; the same storage warning cannot be interpreted identically. Which measured outcome would verify the intended behavior?

  1. A global datastore green tile is used despite a cluster-specific inaccessible object
  2. The operator chooses architecture-specific remediation and both clusters regain compliant health
  3. A replacement procedure searches for OSA cache disks inside an ESA device configuration
  4. The incident closes only because alerts were disabled, while object failures persist

Explanation

Correct Answer

B:

This demonstrates diagnostics were matched to the real architecture.

Incorrect Answers

A:

General visibility does not prove every affected object's recovery.

C:

That runbook targets a storage structure the ESA design does not use.

D:

Alert suppression is not storage health restoration.

Question 87

Scenario: A newly created vSAN cluster has empty hosts and local storage devices, and the team needs a supported shared vSAN datastore. Which implementation choice fits these constraints?

  1. Ignore vSAN network connectivity because management ping succeeds
  2. Enable the feature on an unsupported lone host without resilience planning
  3. Present a VMFS datastore from one host and call it distributed vSAN storage
  4. Validate host networking, eligible storage devices, cluster membership and vSAN service configuration

Explanation

Correct Answer

D:

vSAN requires compatible hosts, storage and communication before shared objects become available.

Incorrect Answers

A:

Management reachability does not guarantee vSAN data-plane communication.

B:

A simple toggle does not provide a supported clustered storage design.

C:

A VMFS extent does not become a vSAN object store through naming.

Question 88

Scenario: A newly created vSAN cluster has empty hosts and local storage devices, and the team needs a supported shared vSAN datastore. Which result should block sign-off until it is achieved?

  1. A vSAN object can be seen on one host but becomes inaccessible during host movement
  2. The vSAN datastore is accessible across cluster hosts and storage health checks pass
  3. The wizard shows a green task though storage eligibility and cluster health remain red
  4. All host management addresses respond while the vSAN vmkernel data network is partitioned

Explanation

Correct Answer

B:

It verifies actual distributed storage functionality after enablement.

Incorrect Answers

A:

That indicates missing shared object availability or network correctness.

C:

Deployment-task success is not an operational storage verification.

D:

Control-plane ping success does not prove the vSAN transport path.

Question 89

Scenario: After enabling vSAN on a cluster, one host has not joined the same unicast storage membership view as the others. Which administrative action best meets the stated requirement?

  1. Delete all existing storage objects before testing vmkernel connectivity
  2. Increase VM disk capacity to fix network partition warnings
  3. Change only the guest VM DNS resolver to repair host vSAN membership
  4. Inspect vSAN vmkernel traffic, multicast-independent connectivity and cluster membership status

Explanation

Correct Answer

D:

Cluster communication must be consistent for metadata and object access in supported vSAN versions.

Incorrect Answers

A:

A destructive reset is unjustified for a network membership symptom.

B:

Storage quota does not repair a broken vSAN communication path.

C:

A guest DNS setting cannot restore host-to-host storage transport.

Question 90

Scenario: After enabling vSAN on a cluster, one host has not joined the same unicast storage membership view as the others. Which observation would demonstrate that the requirement is satisfied?

  1. One VM powers on from cached data while resynchronization remains blocked
  2. The host can reach vCenter but still cannot communicate on the vSAN vmkernel interface
  3. The cluster appears healthy on one node while other nodes report a partition
  4. Every node reports consistent cluster membership and storage-object health

Explanation

Correct Answer

D:

A common membership view with available objects confirms recovery of the vSAN fabric.

Incorrect Answers

A:

A single running workload does not prove storage cluster communication.

B:

Management access is not equivalent to vSAN member connectivity.

C:

A split membership view cannot establish stable shared storage.