McAfee-Secured Website

Exam Bundle

Exam Code: 2V0-17.25

Exam Name VMware Cloud Foundation 9.0 Administrator

Certification Provider: VMware

Corresponding Certification: VCP-VCF Administrator

VMware 2V0-17.25 Bundle $19.99

100% VMware 2V0-17.25 Guaranteed Success With Testking Training Materials

Get Real 2V0-17.25 Exam Questions & Expert Verified Answers as Experienced on the Real Exam!

  • Questions & Answers

    2V0-17.25 Questions & Answers

    100 Questions & Answers

    The ultimate exam preparation tool, Questions & Answers mirrors the actual 2V0-17.25 exam while allowing you to hone and measure every aspect of your test-taking ability.

  • Study Guide

    2V0-17.25 Study Guide

    121 PDF Pages

    Developed by industry experts, this 121-page guide spells out in painstaking detail all of the information you need to ace 2V0-17.25 exam.

VMware Cloud Foundation 9.0 Administrator (2V0-17.25) Practice Tests

Satisfaction Guaranteed

Money Back Guarantee

Testking provides hassle-free money back guarantee with our products. That is because we have 100% trust in the abilities of our professional and experience product team, and our record is a proof of that.

99.6% PASS RATE
Total Cost: $154.98
Bundle Price: $134.99

Purchase Individually

  • Questions & Answers

    Questions & Answers

    100 Questions

    $124.99
  • Study Guide

    Study Guide

    121 PDF Pages

    $29.99

VMware 2V0-17.25 Practice Test 8

Question 70

Scenario: A storage appliance provides a supported NFS export, and a cluster needs all hosts to mount the same repository for virtual disks. Which observation would demonstrate that the requirement is satisfied?

  1. A VM can access an SMB guest drive but ESX cannot register its VMDK
  2. The export responds to ping but access is denied by its filesystem permissions
  3. The same NFS datastore mounts successfully on all target hosts and VM file operations work
  4. One host mounts an export with a different path than its peers

Explanation

Correct Answer

C:

End-to-end mount and file access validate the requested shared repository.

Incorrect Answers

A:

Guest file protocols do not prove hypervisor datastore compatibility.

B:

Network reachability does not establish an authorized NFS datastore.

D:

An inconsistent mount cannot guarantee access to the same VM files.

Question 71

Scenario: An ESX cluster sees an iSCSI target through one storage path but requires resilience if a storage switch fails. What is the most defensible next step for the VCF administrator?

  1. Configure supported iSCSI multipathing and independent physical path connectivity
  2. Use one untested static iSCSI session and disable path monitoring
  3. Place every iSCSI vmkernel port behind the same failed physical uplink
  4. Increase the VM's vCPU count to improve storage path availability

Explanation

Correct Answer

A:

Redundant discovered paths protect access when one initiator-to-target route fails.

Incorrect Answers

B:

A single uncontrolled route leaves the datastore vulnerable to network loss.

C:

Apparently multiple logical paths can still share one hardware failure domain.

D:

CPU allocation cannot create a second storage network route.

Question 72

Scenario: An ESX cluster sees an iSCSI target through one storage path but requires resilience if a storage switch fails. During acceptance testing, what result should the team require?

  1. The SAN reports capacity headroom while storage traffic stops during uplink failure
  2. A path-failure drill keeps the datastore accessible through a verified alternate route
  3. The target is discoverable only while one storage switch remains active
  4. Two vmkernel labels exist but both bind to the same broken uplink

Explanation

Correct Answer

B:

That tests real storage continuity instead of nominal multipath configuration.

Incorrect Answers

A:

Capacity figures cannot establish multipath availability.

C:

A remaining single failure domain defeats resilience.

D:

Multiple names do not establish physical route diversity.

Question 73

Scenario: After replacing an ESX host, its storage adapter sees the array but the shared VMFS datastore appears missing. Which configuration change best resolves this problem?

  1. Reformat the visible LUN immediately to make it usable
  2. Check device presentation, partition signatures and supported mount or resignature actions before changing data
  3. Delete every storage path and rebuild the array without confirming identity
  4. Clone a new VM on an unrelated local volume and mark the shared datastore recovered

Explanation

Correct Answer

B:

An existing datastore may need correct LUN visibility or safe mounting, not formatting.

Incorrect Answers

A:

Formatting a shared production datastore could destroy existing VM content.

C:

Destructive changes are unjustified before inspecting device signatures and access.

D:

A replacement VM does not restore the missing shared repository.

Question 74

Scenario: After replacing an ESX host, its storage adapter sees the array but the shared VMFS datastore appears missing. What evidence distinguishes a successful change from a misleading green status?

  1. A local VM powers on while other cluster hosts still lack the shared repository
  2. The original VMFS content is mounted with intact registered VM files on the intended host
  3. The adapter sees target ports but no datastore extent can be accessed
  4. A new empty datastore appears after the old VMFS signature was overwritten

Explanation

Correct Answer

B:

It shows storage access was recovered without data destruction.

Incorrect Answers

A:

Unrelated local compute success does not prove the datastore repair.

C:

Target discovery alone does not ensure VMFS visibility.

D:

An empty replacement does not recover the original shared files.

Question 75

Scenario: A VM storage migration is planned between two datastore types while the application must remain available during the move. How should the platform team proceed?

  1. Delete the source datastore before verifying migrated virtual disk files
  2. Check storage vMotion support and perform a controlled live disk migration with capacity checks
  3. Move only the VM inventory folder and assume virtual disks changed datastore
  4. Unregister and power off the production VM before every datastore relocation

Explanation

Correct Answer

B:

Supported storage migration can relocate backing files without stopping a running VM.

Incorrect Answers

A:

Premature deletion removes the recovery path and risks workload data loss.

C:

Inventory location is independent from the actual storage files.

D:

An offline process violates the stated live-service requirement when supported mobility exists.

Question 76

Scenario: A VM storage migration is planned between two datastore types while the application must remain available during the move. Which measured outcome would verify the intended behavior?

  1. The VM stays available and its VMDKs reference the intended target datastore after migration
  2. The target has free capacity but storage access is missing from one cluster host
  3. The application is offline for the full copy even though live migration was required
  4. The task reports completion but the active VMDK still points to the old datastore

Explanation

Correct Answer

A:

That verifies both service continuity and actual disk relocation.

Incorrect Answers

B:

Free bytes alone cannot guarantee supported live disk migration.

C:

Successful eventual relocation does not satisfy the continuity constraint.

D:

A task message without disk-path verification is insufficient.

Question 77

Scenario: A new all-flash cluster uses hardware certified for vSAN Express Storage Architecture and seeks the native ESA data path. Which implementation choice fits these constraints?

  1. Force an OSA-only cache-and-capacity disk group arrangement into an ESA configuration
  2. Select vSAN ESA after checking supported hardware and 9.0 interoperability requirements
  3. Enable ESA on uncertified legacy disks solely because all devices use flash
  4. Assume OSA and ESA can share arbitrary disk formats in one cluster without validation

Explanation

Correct Answer

B:

ESA is designed for supported modern storage hardware and differs architecturally from OSA.

Incorrect Answers

A:

ESA uses a different architecture and hardware compatibility profile from traditional OSA.

C:

Flash media alone does not establish ESA readiness and supportability.

D:

The two storage architectures are not interchangeable configuration modes per disk.

Question 78

Scenario: A new all-flash cluster uses hardware certified for vSAN Express Storage Architecture and seeks the native ESA data path. Which result should block sign-off until it is achieved?

  1. Cluster health identifies ESA and all devices pass relevant compatibility checks
  2. New disks are visible as devices but the ESA datastore never becomes healthy
  3. The dashboard calls the cluster ESA while the storage devices fail compatibility validation
  4. The cluster requires traditional OSA cache tiers even though ESA was selected

Explanation

Correct Answer

A:

That confirms the correct architecture was deployed on supported hardware.

Incorrect Answers

B:

Device presence does not prove the vSAN architecture is operating.

C:

A label cannot establish supportable ESA design.

D:

That suggests the configuration model does not match the intended architecture.

Question 79

Scenario: A company has an existing supported vSAN OSA cluster and wants to know whether ESA can be enabled simply by toggling a storage policy. Which administrative action best meets the stated requirement?

  1. Modify an individual VM failure-tolerance policy and claim its cluster became ESA
  2. Enable a guest operating-system SSD flag as the conversion mechanism
  3. Rename the OSA disk groups to ESA groups without hardware or deployment changes
  4. Plan an architecture-supported migration to ESA rather than treating it as a VM-level policy switch

Explanation

Correct Answer

D:

OSA and ESA are cluster storage architectures; policy edits do not change the underlying design.

Incorrect Answers

A:

Data protection policy does not convert a storage architecture.

B:

Guest hints cannot replace cluster-level vSAN architecture deployment.

C:

Renaming identifiers does not reconfigure device architecture or compatibility.

Question 80

Scenario: A company has an existing supported vSAN OSA cluster and wants to know whether ESA can be enabled simply by toggling a storage policy. Which observation would demonstrate that the requirement is satisfied?

  1. The same OSA cache disk groups remain while a VM policy says ESA
  2. A vCenter inventory label changes while storage health still reports OSA
  3. VM performance improves briefly but no architecture migration was performed
  4. The destination architecture is verified as ESA with compatible hardware and migrated objects

Explanation

Correct Answer

D:

That demonstrates a real transition rather than a policy-only label change.

Incorrect Answers

A:

An invented policy name is not a valid architecture conversion.

B:

Inventory labeling cannot establish an underlying storage data-path change.

C:

A performance sample does not show an OSA-to-ESA conversion.