Question 620
After correcting this architecture issue: A remote user can authenticate yet cannot reach a private application because no service connection path exists. Which ongoing control belongs in the runbook?
Explanation
Correct Answer
Run private app reachability tests following site routing changes. This lowers the risk linked to: Mobile user authentication and internal network reachability are separate design layers. Verification should show: A sample user-to-private-app flow succeeds with matching policy logs and route tests.
Incorrect Answers
Validate group propagation and rule hits across access locations. This safeguard addresses another situation: A mobile workforce accesses internal apps but the Prisma Access Mobile User design lacks user group policy consistency. It is less directly relevant than the control for: Mobile user authentication and internal network reachability are separate design layers.
Review peak concurrency and performance trends quarterly. This safeguard addresses another situation: A company supports thousands of remote users without verifying cloud identity session or log scaling. It is less directly relevant than the control for: Mobile user authentication and internal network reachability are separate design layers.
Test representative web, thick-client and DNS applications before replacing agents. This safeguard addresses another situation: An organization already deploys GlobalProtect across managed laptops, but a redesign assumes Prisma Browser replaces all device tunnel functionality. It is less directly relevant than the control for: Mobile user authentication and internal network reachability are separate design layers.