Question 150
At Brookside Manufacturing, the plant operations team is planning an industrial Ethernet modernization under a requirement for planned downtime and resilient cabling. Following a proposed correction, the change manager requires evidence for this original fault: A new switch is connected below a managed switch but FortiGate does not discover it because the inter-switch ports lack the required FortiLink behavior. Which observation BEST demonstrates that the fix worked?
Explanation
Correct Answer
The new serial-numbered switch appears in the FortiGate discovery list and can be authorized. This observation verifies the specific reported problem, A new switch is connected below a managed switch but FortiGate does not discover it because the inter-switch ports lack the required FortiLink behavior. The intended correction was: Check auto-discovery and approved inter-switch link configuration before treating the device as defective. It provides a directly testable outcome for the Brookside Manufacturing environment rather than treating a completed change ticket as proof.
Incorrect Answers
All intended members show synchronized active aggregation state with no suspended mismatched links. For Brookside Manufacturing, that measurement would support a separate technical case: An administrator bundles ports with different link speeds into an aggregation even though that combination is unsupported. Its corresponding remedy is: Select compatible member interfaces under the device's supported LAG requirements and confirm equal settings. The reported Brookside Manufacturing condition is A new switch is connected below a managed switch but FortiGate does not discover it because the inter-switch ports lack the required FortiLink behavior. So the required outcome is: The new serial-numbered switch appears in the FortiGate discovery list and can be authorized.
A FortiGate failover test preserves managed-switch connectivity with no unintended Layer 2 loop. For Brookside Manufacturing, that measurement would support a separate technical case: A FortiGate HA cluster is planned to manage a FortiSwitch group using the same single uplink as a non-HA topology. Its corresponding remedy is: Design the supported HA FortiLink and switching topology, including failover and loop avoidance. The reported Brookside Manufacturing condition is A new switch is connected below a managed switch but FortiGate does not discover it because the inter-switch ports lack the required FortiLink behavior. So the required outcome is: The new serial-numbered switch appears in the FortiGate discovery list and can be authorized.
Both switches report healthy peer and interchassis link state, and downstream traffic uses the intended redundant path. For Brookside Manufacturing, that measurement would support a separate technical case: An MCLAG pair is cabled without a correctly configured interchassis link for peer synchronization. Its corresponding remedy is: Configure and validate the supported MCLAG interchassis link and peer relationship before enabling downlinks. The reported Brookside Manufacturing condition is A new switch is connected below a managed switch but FortiGate does not discover it because the inter-switch ports lack the required FortiLink behavior. So the required outcome is: The new serial-numbered switch appears in the FortiGate discovery list and can be authorized.