McAfee-Secured Website

Exam Bundle

Exam Code: 220-1201

Exam Name CompTIA A+ Certification Exam: Core 1

Certification Provider: CompTIA

Corresponding Certification: CompTIA A+

CompTIA 220-1201 Bundle $44.99

100% CompTIA 220-1201 Guaranteed Success With Testking Training Materials

Get Real 220-1201 Exam Questions & Expert Verified Answers as Experienced on the Real Exam!

  • Questions & Answers

    220-1201 Questions & Answers

    527 Questions & Answers

    The ultimate exam preparation tool, Questions & Answers mirrors the actual 220-1201 exam while allowing you to hone and measure every aspect of your test-taking ability.

  • 220-1201 Video Course

    220-1201 Video Course

    106 Video Lectures

    220-1201 Video Course is developed by CompTIA Professionals to help you pass the 220-1201 exam.

    Description

    This course will improve your knowledge and skills required to pass CompTIA A+ Certification Exam: Core 1 exam.
  • Study Guide

    220-1201 Study Guide

    2615 PDF Pages

    Developed by industry experts, this 2615-page guide spells out in painstaking detail all of the information you need to ace 220-1201 exam.

CompTIA A+ Certification Exam: Core 1 (220-1201) Practice Tests

Satisfaction Guaranteed

Money Back Guarantee

Testking provides hassle-free money back guarantee with our products. That is because we have 100% trust in the abilities of our professional and experience product team, and our record is a proof of that.

99.6% PASS RATE
Total Cost: $194.97
Bundle Price: $149.98

Purchase Individually

  • Questions & Answers

    Questions & Answers

    527 Questions

    $124.99
  • 220-1201 Video Course

    Video Course

    106 Video Lectures

    $39.99
  • Study Guide

    Study Guide

    2615 PDF Pages

    $29.99

CompTIA 220-1201 Practice Test 92

Question 910

A desktop posts correctly with integrated graphics but fails to initialize after installing a discrete GPU that requires auxiliary power. Which test outcome demonstrates that the chosen action worked?

  1. A known-good load works at the outlet and the PC then powers on.
  2. Pressing the case switch starts POST reliably on repeated attempts.
  3. The discrete graphics card is detected and displays output under load.
  4. POST completes and a memory diagnostic reports no installation errors.

Explanation

Correct Answer

C:

Some expansion GPUs need dedicated power beyond the PCIe slot's supply. The outcome “The discrete graphics card is detected and displays output under load.” verifies the action “Connect the correct GPU power leads and confirm PSU capacity.” for this situation: A desktop posts correctly with integrated graphics but fails to initialize after installing a discrete GPU that requires auxiliary power.

Incorrect Answers

A:

Absence of mains power explains all loss of standby indicators. For the situation described—A desktop posts correctly with integrated graphics but fails to initialize after installing a discrete GPU that requires auxiliary power—this would not demonstrate the specified intervention. The relevant evidence is “The discrete graphics card is detected and displays output under load.”.

B:

Standby power can be present while an unplugged front-panel switch prevents the start signal. For the situation described—A desktop posts correctly with integrated graphics but fails to initialize after installing a discrete GPU that requires auxiliary power—this would not demonstrate the specified intervention. The relevant evidence is “The discrete graphics card is detected and displays output under load.”.

D:

Incomplete DIMM seating interrupts electrical contact and can prevent memory training. For the situation described—A desktop posts correctly with integrated graphics but fails to initialize after installing a discrete GPU that requires auxiliary power—this would not demonstrate the specified intervention. The relevant evidence is “The discrete graphics card is detected and displays output under load.”.

Question 911

A workstation's expansion devices disappear after a firmware reset disables the PCIe slot hosting its network card. Which action most directly addresses this problem?

  1. Restore a CPU supported by the motherboard socket and firmware.
  2. Check GPU seating, PCIe power, and PSU capacity systematically.
  3. Restore the supported expansion-slot configuration in firmware.
  4. Connect the correct GPU power leads and confirm PSU capacity.

Explanation

Correct Answer

C:

Disabled PCIe resources can hide otherwise functional installed adapters. In this situation—A workstation's expansion devices disappear after a firmware reset disables the PCIe slot hosting its network card—the right response is “Restore the supported expansion-slot configuration in firmware.”. A confirming result would be “The NIC is enumerated in the OS and establishes Ethernet link.”.

Incorrect Answers

A:

An unsupported CPU can prevent initialization before display output. That does not directly address the condition described—A workstation's expansion devices disappear after a firmware reset disables the PCIe slot hosting its network card. “Restore the supported expansion-slot configuration in firmware.” is the appropriate response because disabled PCIe resources can hide otherwise functional installed adapters.

B:

Discrete graphics introduce expansion and power requirements absent from integrated video. That does not directly address the condition described—A workstation's expansion devices disappear after a firmware reset disables the PCIe slot hosting its network card. “Restore the supported expansion-slot configuration in firmware.” is the appropriate response because disabled PCIe resources can hide otherwise functional installed adapters.

D:

Some expansion GPUs need dedicated power beyond the PCIe slot's supply. That does not directly address the condition described—A workstation's expansion devices disappear after a firmware reset disables the PCIe slot hosting its network card. “Restore the supported expansion-slot configuration in firmware.” is the appropriate response because disabled PCIe resources can hide otherwise functional installed adapters.

Question 912

A workstation's expansion devices disappear after a firmware reset disables the PCIe slot hosting its network card. Which result BEST confirms the problem has been resolved?

  1. The NIC is enumerated in the OS and establishes Ethernet link.
  2. The existing OS boots without repartitioning the storage.
  3. Fan speeds and component temperature remain stable during load.
  4. The upgraded CPU is recognized and the system completes POST.

Explanation

Correct Answer

A:

Disabled PCIe resources can hide otherwise functional installed adapters. The outcome “The NIC is enumerated in the OS and establishes Ethernet link.” verifies the action “Restore the supported expansion-slot configuration in firmware.” for this situation: A workstation's expansion devices disappear after a firmware reset disables the PCIe slot hosting its network card.

Incorrect Answers

B:

Lost firmware boot settings can hide a valid installed bootloader. For the situation described—A workstation's expansion devices disappear after a firmware reset disables the PCIe slot hosting its network card—this would not demonstrate the specified intervention. The relevant evidence is “The NIC is enumerated in the OS and establishes Ethernet link.”.

C:

Blocked airflow can raise chassis and component temperatures. For the situation described—A workstation's expansion devices disappear after a firmware reset disables the PCIe slot hosting its network card—this would not demonstrate the specified intervention. The relevant evidence is “The NIC is enumerated in the OS and establishes Ethernet link.”.

D:

A CPU may fit its socket yet need updated firmware microcode to initialize. For the situation described—A workstation's expansion devices disappear after a firmware reset disables the PCIe slot hosting its network card—this would not demonstrate the specified intervention. The relevant evidence is “The NIC is enumerated in the OS and establishes Ethernet link.”.

Question 913

A desktop repeatedly boots to an 'operating system not found' message, while BIOS detects the SSD and a recent update changed boot order. What is the MOST appropriate technician response?

  1. Restore the appropriate UEFI boot manager entry as the first boot target.
  2. Restore partition metadata or the system image from a trusted backup.
  3. Repair the correct UEFI/EFI boot configuration on the cloned device.
  4. Rebalance I/O or upgrade the storage performance tier for the workload.

Explanation

Correct Answer

A:

Wrong firmware boot priority can block startup despite a healthy detected disk. In this situation—A desktop repeatedly boots to an 'operating system not found' message, while BIOS detects the SSD and a recent update changed boot order—the right response is “Restore the appropriate UEFI boot manager entry as the first boot target.”. A confirming result would be “The OS loads from the original SSD without reinstalling the filesystem.”.

Incorrect Answers

B:

Logical corruption can prevent boot without physical media failure. That does not directly address the condition described—A desktop repeatedly boots to an 'operating system not found' message, while BIOS detects the SSD and a recent update changed boot order. “Restore the appropriate UEFI boot manager entry as the first boot target.” is the appropriate response because wrong firmware boot priority can block startup despite a healthy detected disk.

C:

Cloning data does not always preserve a working firmware boot registration. That does not directly address the condition described—A desktop repeatedly boots to an 'operating system not found' message, while BIOS detects the SSD and a recent update changed boot order. “Restore the appropriate UEFI boot manager entry as the first boot target.” is the appropriate response because wrong firmware boot priority can block startup despite a healthy detected disk.

D:

Healthy disks can still be performance-bottlenecked by excessive demand. That does not directly address the condition described—A desktop repeatedly boots to an 'operating system not found' message, while BIOS detects the SSD and a recent update changed boot order. “Restore the appropriate UEFI boot manager entry as the first boot target.” is the appropriate response because wrong firmware boot priority can block startup despite a healthy detected disk.

Question 914

A desktop repeatedly boots to an 'operating system not found' message, while BIOS detects the SSD and a recent update changed boot order. Which observation directly verifies a successful repair?

  1. The cloned system boots and accessible files match the source.
  2. The installed operating system launches without disk replacement.
  3. Measured read/write latency returns to the required service threshold.
  4. The OS loads from the original SSD without reinstalling the filesystem.

Explanation

Correct Answer

D:

Wrong firmware boot priority can block startup despite a healthy detected disk. The outcome “The OS loads from the original SSD without reinstalling the filesystem.” verifies the action “Restore the appropriate UEFI boot manager entry as the first boot target.” for this situation: A desktop repeatedly boots to an 'operating system not found' message, while BIOS detects the SSD and a recent update changed boot order.

Incorrect Answers

A:

Cloning data does not always preserve a working firmware boot registration. For the situation described—A desktop repeatedly boots to an 'operating system not found' message, while BIOS detects the SSD and a recent update changed boot order—this would not demonstrate the specified intervention. The relevant evidence is “The OS loads from the original SSD without reinstalling the filesystem.”.

B:

Firmware enumeration proves a storage device exists; wrong boot selection can still stop startup. For the situation described—A desktop repeatedly boots to an 'operating system not found' message, while BIOS detects the SSD and a recent update changed boot order—this would not demonstrate the specified intervention. The relevant evidence is “The OS loads from the original SSD without reinstalling the filesystem.”.

C:

Healthy storage can become a performance bottleneck when simultaneous requests exceed capacity. For the situation described—A desktop repeatedly boots to an 'operating system not found' message, while BIOS detects the SSD and a recent update changed boot order—this would not demonstrate the specified intervention. The relevant evidence is “The OS loads from the original SSD without reinstalling the filesystem.”.

Question 915

After moving a RAID controller and its member drives to a replacement chassis, the controller marks the existing set as a foreign configuration. Which change best satisfies the stated requirement?

  1. Preserve the member order and import the documented foreign array configuration only after confirming metadata and backups.
  2. Replace the damaged SATA data cable and inspect port contacts before replacing the SSD.
  3. Stop writes and recover from protected backups or qualified data-recovery procedures.
  4. Keep remaining healthy disks online until the rebuild completes and investigate non-disruptively.

Explanation

Correct Answer

A:

Importing valid existing RAID metadata can restore recognition; initializing a foreign set risks destroying recoverable data. In this situation—After moving a RAID controller and its member drives to a replacement chassis, the controller marks the existing set as a foreign configuration—the right response is “Preserve the member order and import the documented foreign array configuration only after confirming metadata and backups.”. A confirming result would be “The original logical volume is recognized intact without initializing or formatting its member disks.”.

Incorrect Answers

B:

SATA CRC errors often implicate signal integrity or cabling rather than exhausted flash media. That does not directly address the condition described—After moving a RAID controller and its member drives to a replacement chassis, the controller marks the existing set as a foreign configuration. “Preserve the member order and import the documented foreign array configuration only after confirming metadata and backups.” is the appropriate response because importing valid existing RAID metadata can restore recognition; initializing a foreign set risks destroying recoverable data.

C:

RAID 5's single parity cannot tolerate two simultaneous missing members. That does not directly address the condition described—After moving a RAID controller and its member drives to a replacement chassis, the controller marks the existing set as a foreign configuration. “Preserve the member order and import the documented foreign array configuration only after confirming metadata and backups.” is the appropriate response because importing valid existing RAID metadata can restore recognition; initializing a foreign set risks destroying recoverable data.

D:

Removing additional members during a degraded rebuild risks data loss. That does not directly address the condition described—After moving a RAID controller and its member drives to a replacement chassis, the controller marks the existing set as a foreign configuration. “Preserve the member order and import the documented foreign array configuration only after confirming metadata and backups.” is the appropriate response because importing valid existing RAID metadata can restore recognition; initializing a foreign set risks destroying recoverable data.

Question 916

After moving a RAID controller and its member drives to a replacement chassis, the controller marks the existing set as a foreign configuration. What evidence shows that the intended requirement has been met?

  1. The original logical volume is recognized intact without initializing or formatting its member disks.
  2. Interface CRC errors stop increasing and large file copies complete without retries.
  3. Restored data passes application integrity checks on a new healthy array.
  4. A sustained export keeps the SSD temperature within limits and the device stays enumerated.

Explanation

Correct Answer

A:

Importing valid existing RAID metadata can restore recognition; initializing a foreign set risks destroying recoverable data. The outcome “The original logical volume is recognized intact without initializing or formatting its member disks.” verifies the action “Preserve the member order and import the documented foreign array configuration only after confirming metadata and backups.” for this situation: After moving a RAID controller and its member drives to a replacement chassis, the controller marks the existing set as a foreign configuration.

Incorrect Answers

B:

SATA CRC errors often implicate signal integrity or cabling rather than exhausted flash media. For the situation described—After moving a RAID controller and its member drives to a replacement chassis, the controller marks the existing set as a foreign configuration—this would not demonstrate the specified intervention. The relevant evidence is “The original logical volume is recognized intact without initializing or formatting its member disks.”.

C:

RAID 5 parity cannot reconstruct data after two independent member failures. For the situation described—After moving a RAID controller and its member drives to a replacement chassis, the controller marks the existing set as a foreign configuration—this would not demonstrate the specified intervention. The relevant evidence is “The original logical volume is recognized intact without initializing or formatting its member disks.”.

D:

NVMe controller thermal protection can interrupt performance or operation when cooling is inadequate. For the situation described—After moving a RAID controller and its member drives to a replacement chassis, the controller marks the existing set as a foreign configuration—this would not demonstrate the specified intervention. The relevant evidence is “The original logical volume is recognized intact without initializing or formatting its member disks.”.

Question 917

A technician attempts a RAID 5 rebuild after its second disk fails before the first member was replaced. What should the technician configure or repair to resolve this issue?

  1. Replace the damaged SATA data cable and inspect port contacts before replacing the SSD.
  2. Separate or schedule the competing I/O workload and provision suitable disk throughput.
  3. Stop stressing the drive and recover data from backups or specialist service.
  4. Stop writes and recover from protected backups or qualified data-recovery procedures.

Explanation

Correct Answer

D:

RAID 5's single parity cannot tolerate two simultaneous missing members. In this situation—A technician attempts a RAID 5 rebuild after its second disk fails before the first member was replaced—the right response is “Stop writes and recover from protected backups or qualified data-recovery procedures.”. A confirming result would be “Restored application data passes consistency tests on healthy storage.”.

Incorrect Answers

A:

SATA CRC errors often implicate signal integrity or cabling rather than exhausted flash media. That does not directly address the condition described—A technician attempts a RAID 5 rebuild after its second disk fails before the first member was replaced. “Stop writes and recover from protected backups or qualified data-recovery procedures.” is the appropriate response because rAID 5's single parity cannot tolerate two simultaneous missing members.

B:

Healthy storage can become a performance bottleneck when simultaneous requests exceed capacity. That does not directly address the condition described—A technician attempts a RAID 5 rebuild after its second disk fails before the first member was replaced. “Stop writes and recover from protected backups or qualified data-recovery procedures.” is the appropriate response because rAID 5's single parity cannot tolerate two simultaneous missing members.

C:

Mechanical clicking plus failed reads suggests physical drive failure. That does not directly address the condition described—A technician attempts a RAID 5 rebuild after its second disk fails before the first member was replaced. “Stop writes and recover from protected backups or qualified data-recovery procedures.” is the appropriate response because rAID 5's single parity cannot tolerate two simultaneous missing members.

Question 918

A technician attempts a RAID 5 rebuild after its second disk fails before the first member was replaced. How should the technician verify the corrective change?

  1. Recovered files validate against backup hashes on healthy storage.
  2. The array returns to healthy mirrored status with data intact.
  3. Restored application data passes consistency tests on healthy storage.
  4. Measured read/write latency returns to the required service threshold.

Explanation

Correct Answer

C:

RAID 5's single parity cannot tolerate two simultaneous missing members. The outcome “Restored application data passes consistency tests on healthy storage.” verifies the action “Stop writes and recover from protected backups or qualified data-recovery procedures.” for this situation: A technician attempts a RAID 5 rebuild after its second disk fails before the first member was replaced.

Incorrect Answers

A:

Mechanical clicking plus failed reads suggests physical drive failure. For the situation described—A technician attempts a RAID 5 rebuild after its second disk fails before the first member was replaced—this would not demonstrate the specified intervention. The relevant evidence is “Restored application data passes consistency tests on healthy storage.”.

B:

RAID 1 tolerates a single member failure through mirroring. For the situation described—A technician attempts a RAID 5 rebuild after its second disk fails before the first member was replaced—this would not demonstrate the specified intervention. The relevant evidence is “Restored application data passes consistency tests on healthy storage.”.

D:

Healthy storage can become a performance bottleneck when simultaneous requests exceed capacity. For the situation described—A technician attempts a RAID 5 rebuild after its second disk fails before the first member was replaced—this would not demonstrate the specified intervention. The relevant evidence is “Restored application data passes consistency tests on healthy storage.”.

Question 919

A drive has plenty of free capacity but a SATA data link records growing UDMA CRC errors and files copy intermittently. Which intervention is best supported by the evidence?

  1. Separate or schedule the competing I/O workload and provision suitable disk throughput.
  2. Replace the damaged SATA data cable and inspect port contacts before replacing the SSD.
  3. Stop writes and recover from protected backups or qualified data-recovery procedures.
  4. Stop stressing the drive and recover data from backups or specialist service.

Explanation

Correct Answer

B:

SATA CRC errors often implicate signal integrity or cabling rather than exhausted flash media. In this situation—A drive has plenty of free capacity but a SATA data link records growing UDMA CRC errors and files copy intermittently—the right response is “Replace the damaged SATA data cable and inspect port contacts before replacing the SSD.”. A confirming result would be “Interface CRC errors stop increasing and large file copies complete without retries.”.

Incorrect Answers

A:

Healthy storage can become a performance bottleneck when simultaneous requests exceed capacity. That does not directly address the condition described—A drive has plenty of free capacity but a SATA data link records growing UDMA CRC errors and files copy intermittently. “Replace the damaged SATA data cable and inspect port contacts before replacing the SSD.” is the appropriate response because sATA CRC errors often implicate signal integrity or cabling rather than exhausted flash media.

C:

RAID 5's single parity cannot tolerate two simultaneous missing members. That does not directly address the condition described—A drive has plenty of free capacity but a SATA data link records growing UDMA CRC errors and files copy intermittently. “Replace the damaged SATA data cable and inspect port contacts before replacing the SSD.” is the appropriate response because sATA CRC errors often implicate signal integrity or cabling rather than exhausted flash media.

D:

Mechanical clicking plus failed reads suggests physical drive failure. That does not directly address the condition described—A drive has plenty of free capacity but a SATA data link records growing UDMA CRC errors and files copy intermittently. “Replace the damaged SATA data cable and inspect port contacts before replacing the SSD.” is the appropriate response because sATA CRC errors often implicate signal integrity or cabling rather than exhausted flash media.

Question 920

A drive has plenty of free capacity but a SATA data link records growing UDMA CRC errors and files copy intermittently. Which test outcome demonstrates that the chosen action worked?

  1. Interface CRC errors stop increasing and large file copies complete without retries.
  2. Measured I/O latency and queue depth fall under representative transactions.
  3. The disk spins up and completes a sustained read test without disconnects.
  4. A sustained export keeps the SSD temperature within limits and the device stays enumerated.

Explanation

Correct Answer

A:

SATA CRC errors often implicate signal integrity or cabling rather than exhausted flash media. The outcome “Interface CRC errors stop increasing and large file copies complete without retries.” verifies the action “Replace the damaged SATA data cable and inspect port contacts before replacing the SSD.” for this situation: A drive has plenty of free capacity but a SATA data link records growing UDMA CRC errors and files copy intermittently.

Incorrect Answers

B:

Healthy disks can still be performance-bottlenecked by excessive demand. For the situation described—A drive has plenty of free capacity but a SATA data link records growing UDMA CRC errors and files copy intermittently—this would not demonstrate the specified intervention. The relevant evidence is “Interface CRC errors stop increasing and large file copies complete without retries.”.

C:

USB bus-power limitations can interrupt motor startup on portable disk enclosures. For the situation described—A drive has plenty of free capacity but a SATA data link records growing UDMA CRC errors and files copy intermittently—this would not demonstrate the specified intervention. The relevant evidence is “Interface CRC errors stop increasing and large file copies complete without retries.”.

D:

NVMe controller thermal protection can interrupt performance or operation when cooling is inadequate. For the situation described—A drive has plenty of free capacity but a SATA data link records growing UDMA CRC errors and files copy intermittently—this would not demonstrate the specified intervention. The relevant evidence is “Interface CRC errors stop increasing and large file copies complete without retries.”.