McAfee-Secured Website

Exam Bundle

Exam Code: 220-1201

Exam Name CompTIA A+ Certification Exam: Core 1

Certification Provider: CompTIA

Corresponding Certification: CompTIA A+

CompTIA 220-1201 Bundle $44.99

100% CompTIA 220-1201 Guaranteed Success With Testking Training Materials

Get Real 220-1201 Exam Questions & Expert Verified Answers as Experienced on the Real Exam!

  • Questions & Answers

    220-1201 Questions & Answers

    527 Questions & Answers

    The ultimate exam preparation tool, Questions & Answers mirrors the actual 220-1201 exam while allowing you to hone and measure every aspect of your test-taking ability.

  • 220-1201 Video Course

    220-1201 Video Course

    106 Video Lectures

    220-1201 Video Course is developed by CompTIA Professionals to help you pass the 220-1201 exam.

    Description

    This course will improve your knowledge and skills required to pass CompTIA A+ Certification Exam: Core 1 exam.
  • Study Guide

    220-1201 Study Guide

    2615 PDF Pages

    Developed by industry experts, this 2615-page guide spells out in painstaking detail all of the information you need to ace 220-1201 exam.

CompTIA A+ Certification Exam: Core 1 (220-1201) Practice Tests

Satisfaction Guaranteed

Money Back Guarantee

Testking provides hassle-free money back guarantee with our products. That is because we have 100% trust in the abilities of our professional and experience product team, and our record is a proof of that.

99.6% PASS RATE
Total Cost: $194.97
Bundle Price: $149.98

Purchase Individually

  • Questions & Answers

    Questions & Answers

    527 Questions

    $124.99
  • 220-1201 Video Course

    Video Course

    106 Video Lectures

    $39.99
  • Study Guide

    Study Guide

    2615 PDF Pages

    $29.99

CompTIA 220-1201 Practice Test 90

Question 890

A desktop is silent when the power button is pressed, but its standby motherboard LED lights and the front-panel power switch cable is disconnected. Which test outcome demonstrates that the chosen action worked?

  1. Power and reset switches perform their intended functions.
  2. The CPU fan spins and startup no longer triggers thermal shutdown.
  3. A known-good load works at the outlet and the PC then powers on.
  4. Pressing the case switch starts POST reliably on repeated attempts.

Explanation

Correct Answer

D:

Standby power can be present while an unplugged front-panel switch prevents the start signal. The outcome “Pressing the case switch starts POST reliably on repeated attempts.” verifies the action “Reconnect the chassis power switch to the correct motherboard header.” for this situation: A desktop is silent when the power button is pressed, but its standby motherboard LED lights and the front-panel power switch cable is disconnected.

Incorrect Answers

A:

Miswired front-panel headers cause misleading power/reset behavior. For the situation described—A desktop is silent when the power button is pressed, but its standby motherboard LED lights and the front-panel power switch cable is disconnected—this would not demonstrate the specified intervention. The relevant evidence is “Pressing the case switch starts POST reliably on repeated attempts.”.

B:

A disconnected cooler can cause rapid thermal protection. For the situation described—A desktop is silent when the power button is pressed, but its standby motherboard LED lights and the front-panel power switch cable is disconnected—this would not demonstrate the specified intervention. The relevant evidence is “Pressing the case switch starts POST reliably on repeated attempts.”.

C:

Absence of mains power explains all loss of standby indicators. For the situation described—A desktop is silent when the power button is pressed, but its standby motherboard LED lights and the front-panel power switch cable is disconnected—this would not demonstrate the specified intervention. The relevant evidence is “Pressing the case switch starts POST reliably on repeated attempts.”.

Question 891

A desktop reaches POST but logs a CPU fan failure and shuts down quickly after a cooler replacement. Which action most directly addresses this problem?

  1. Restore the correct UEFI boot entry and mode for its existing installation.
  2. Connect the replacement fan to the designated CPU header and verify airflow.
  3. Check firmware support and upgrade to a compatible motherboard BIOS if appropriate.
  4. Reseat and isolate memory modules using the board's diagnostic procedure.

Explanation

Correct Answer

B:

A CPU cooler that does not report or deliver cooling can trigger protective shutdown. In this situation—A desktop reaches POST but logs a CPU fan failure and shuts down quickly after a cooler replacement—the right response is “Connect the replacement fan to the designated CPU header and verify airflow.”. A confirming result would be “Firmware reports fan RPM and CPU temperatures stay within limits under load.”.

Incorrect Answers

A:

Lost firmware boot settings can hide a valid installed bootloader. That does not directly address the condition described—A desktop reaches POST but logs a CPU fan failure and shuts down quickly after a cooler replacement. “Connect the replacement fan to the designated CPU header and verify airflow.” is the appropriate response because a CPU cooler that does not report or deliver cooling can trigger protective shutdown.

C:

A CPU may fit its socket yet need updated firmware microcode to initialize. That does not directly address the condition described—A desktop reaches POST but logs a CPU fan failure and shuts down quickly after a cooler replacement. “Connect the replacement fan to the designated CPU header and verify airflow.” is the appropriate response because a CPU cooler that does not report or deliver cooling can trigger protective shutdown.

D:

POST beep patterns can localize a failure to RAM before the OS loads. That does not directly address the condition described—A desktop reaches POST but logs a CPU fan failure and shuts down quickly after a cooler replacement. “Connect the replacement fan to the designated CPU header and verify airflow.” is the appropriate response because a CPU cooler that does not report or deliver cooling can trigger protective shutdown.

Question 892

A desktop reaches POST but logs a CPU fan failure and shuts down quickly after a cooler replacement. Which result BEST confirms the problem has been resolved?

  1. The CPU maintains acceptable load temperatures without rapid throttling.
  2. Firmware reports fan RPM and CPU temperatures stay within limits under load.
  3. Firmware retains the clock and configuration across an overnight unplug.
  4. The discrete graphics card is detected and displays output under load.

Explanation

Correct Answer

B:

A CPU cooler that does not report or deliver cooling can trigger protective shutdown. The outcome “Firmware reports fan RPM and CPU temperatures stay within limits under load.” verifies the action “Connect the replacement fan to the designated CPU header and verify airflow.” for this situation: A desktop reaches POST but logs a CPU fan failure and shuts down quickly after a cooler replacement.

Incorrect Answers

A:

Thermal interface material fills tiny gaps between the heatsink and processor lid. For the situation described—A desktop reaches POST but logs a CPU fan failure and shuts down quickly after a cooler replacement—this would not demonstrate the specified intervention. The relevant evidence is “Firmware reports fan RPM and CPU temperatures stay within limits under load.”.

C:

The coin-cell battery preserves the real-time clock while unplugged. For the situation described—A desktop reaches POST but logs a CPU fan failure and shuts down quickly after a cooler replacement—this would not demonstrate the specified intervention. The relevant evidence is “Firmware reports fan RPM and CPU temperatures stay within limits under load.”.

D:

Some expansion GPUs need dedicated power beyond the PCIe slot's supply. For the situation described—A desktop reaches POST but logs a CPU fan failure and shuts down quickly after a cooler replacement—this would not demonstrate the specified intervention. The relevant evidence is “Firmware reports fan RPM and CPU temperatures stay within limits under load.”.

Question 893

A newly built PC beeps for missing memory after an installer fitted the DIMM into a slot with one retention latch open. What is the MOST appropriate technician response?

  1. Reseat and isolate memory modules using the board's diagnostic procedure.
  2. Replace the failing memory module identified through isolation.
  3. Power down, reseat the memory module completely and lock both latches.
  4. Reconnect the chassis power switch to the correct motherboard header.

Explanation

Correct Answer

C:

Incomplete DIMM seating interrupts electrical contact and can prevent memory training. In this situation—A newly built PC beeps for missing memory after an installer fitted the DIMM into a slot with one retention latch open—the right response is “Power down, reseat the memory module completely and lock both latches.”. A confirming result would be “POST completes and a memory diagnostic reports no installation errors.”.

Incorrect Answers

A:

POST beep patterns can localize a failure to RAM before the OS loads. That does not directly address the condition described—A newly built PC beeps for missing memory after an installer fitted the DIMM into a slot with one retention latch open. “Power down, reseat the memory module completely and lock both latches.” is the appropriate response because incomplete DIMM seating interrupts electrical contact and can prevent memory training.

B:

Reproducible RAM errors indicate faulty memory rather than disk capacity. That does not directly address the condition described—A newly built PC beeps for missing memory after an installer fitted the DIMM into a slot with one retention latch open. “Power down, reseat the memory module completely and lock both latches.” is the appropriate response because incomplete DIMM seating interrupts electrical contact and can prevent memory training.

D:

Standby power can be present while an unplugged front-panel switch prevents the start signal. That does not directly address the condition described—A newly built PC beeps for missing memory after an installer fitted the DIMM into a slot with one retention latch open. “Power down, reseat the memory module completely and lock both latches.” is the appropriate response because incomplete DIMM seating interrupts electrical contact and can prevent memory training.

Question 894

A newly built PC beeps for missing memory after an installer fitted the DIMM into a slot with one retention latch open. Which observation directly verifies a successful repair?

  1. POST completes and a memory diagnostic reports no installation errors.
  2. The discrete graphics card is detected and displays output under load.
  3. The system completes memory stress tests and corrected-error counters remain stable.
  4. Pressing the case switch starts POST reliably on repeated attempts.

Explanation

Correct Answer

A:

Incomplete DIMM seating interrupts electrical contact and can prevent memory training. The outcome “POST completes and a memory diagnostic reports no installation errors.” verifies the action “Power down, reseat the memory module completely and lock both latches.” for this situation: A newly built PC beeps for missing memory after an installer fitted the DIMM into a slot with one retention latch open.

Incorrect Answers

B:

Some expansion GPUs need dedicated power beyond the PCIe slot's supply. For the situation described—A newly built PC beeps for missing memory after an installer fitted the DIMM into a slot with one retention latch open—this would not demonstrate the specified intervention. The relevant evidence is “POST completes and a memory diagnostic reports no installation errors.”.

C:

Growing ECC-corrected error counts can signal a degrading memory module even before uncorrectable failures. For the situation described—A newly built PC beeps for missing memory after an installer fitted the DIMM into a slot with one retention latch open—this would not demonstrate the specified intervention. The relevant evidence is “POST completes and a memory diagnostic reports no installation errors.”.

D:

Standby power can be present while an unplugged front-panel switch prevents the start signal. For the situation described—A newly built PC beeps for missing memory after an installer fitted the DIMM into a slot with one retention latch open—this would not demonstrate the specified intervention. The relevant evidence is “POST completes and a memory diagnostic reports no installation errors.”.

Question 895

A workstation restarts whenever its graphics card ramps up, and a PSU tester reports excessive voltage drop under combined load. Which change best satisfies the stated requirement?

  1. Replace the failing supply with a correctly rated compatible PSU.
  2. Replace the failing case or CPU fan and restore unobstructed airflow.
  3. Replace the failing memory module identified through isolation.
  4. Test and replace an undersized or defective PSU as warranted.

Explanation

Correct Answer

A:

An unstable PSU rail can fail only when current demand increases. In this situation—A workstation restarts whenever its graphics card ramps up, and a PSU tester reports excessive voltage drop under combined load—the right response is “Replace the failing supply with a correctly rated compatible PSU.”. A confirming result would be “Sustained GPU/CPU load completes without unexpected resets.”.

Incorrect Answers

B:

Worn fan bearings reduce cooling performance and can cause overheating. That does not directly address the condition described—A workstation restarts whenever its graphics card ramps up, and a PSU tester reports excessive voltage drop under combined load. “Replace the failing supply with a correctly rated compatible PSU.” is the appropriate response because an unstable PSU rail can fail only when current demand increases.

C:

Reproducible RAM errors indicate faulty memory rather than disk capacity. That does not directly address the condition described—A workstation restarts whenever its graphics card ramps up, and a PSU tester reports excessive voltage drop under combined load. “Replace the failing supply with a correctly rated compatible PSU.” is the appropriate response because an unstable PSU rail can fail only when current demand increases.

D:

High-load shutdown can indicate inadequate power delivery. That does not directly address the condition described—A workstation restarts whenever its graphics card ramps up, and a PSU tester reports excessive voltage drop under combined load. “Replace the failing supply with a correctly rated compatible PSU.” is the appropriate response because an unstable PSU rail can fail only when current demand increases.

Question 896

A workstation restarts whenever its graphics card ramps up, and a PSU tester reports excessive voltage drop under combined load. What evidence shows that the intended requirement has been met?

  1. Sustained GPU/CPU load completes without unexpected resets.
  2. POST succeeds with the installed discrete GPU under load.
  3. A representative GPU/CPU stress test completes without shutdown.
  4. A replacement board completes stable POST and load testing.

Explanation

Correct Answer

A:

An unstable PSU rail can fail only when current demand increases. The outcome “Sustained GPU/CPU load completes without unexpected resets.” verifies the action “Replace the failing supply with a correctly rated compatible PSU.” for this situation: A workstation restarts whenever its graphics card ramps up, and a PSU tester reports excessive voltage drop under combined load.

Incorrect Answers

B:

Discrete graphics introduce expansion and power requirements absent from integrated video. For the situation described—A workstation restarts whenever its graphics card ramps up, and a PSU tester reports excessive voltage drop under combined load—this would not demonstrate the specified intervention. The relevant evidence is “Sustained GPU/CPU load completes without unexpected resets.”.

C:

High-load shutdown can indicate inadequate power delivery. For the situation described—A workstation restarts whenever its graphics card ramps up, and a PSU tester reports excessive voltage drop under combined load—this would not demonstrate the specified intervention. The relevant evidence is “Sustained GPU/CPU load completes without unexpected resets.”.

D:

Physically damaged capacitors indicate an electrical reliability fault. For the situation described—A workstation restarts whenever its graphics card ramps up, and a PSU tester reports excessive voltage drop under combined load—this would not demonstrate the specified intervention. The relevant evidence is “Sustained GPU/CPU load completes without unexpected resets.”.

Question 897

A workstation intermittently corrupts memory under load, and firmware event logs reveal corrected ECC errors rising rapidly on one DIMM. What should the technician configure or repair to resolve this issue?

  1. Clean the contact surfaces and apply the manufacturer-recommended thermal interface.
  2. Isolate and replace the DIMM with the increasing corrected-error count after preserving work.
  3. Check firmware support and upgrade to a compatible motherboard BIOS if appropriate.
  4. Disable the unsupported overclock and restore a verified memory timing profile.

Explanation

Correct Answer

B:

Growing ECC-corrected error counts can signal a degrading memory module even before uncorrectable failures. In this situation—A workstation intermittently corrupts memory under load, and firmware event logs reveal corrected ECC errors rising rapidly on one DIMM—the right response is “Isolate and replace the DIMM with the increasing corrected-error count after preserving work.”. A confirming result would be “The system completes memory stress tests and corrected-error counters remain stable.”.

Incorrect Answers

A:

Thermal interface material fills tiny gaps between the heatsink and processor lid. That does not directly address the condition described—A workstation intermittently corrupts memory under load, and firmware event logs reveal corrected ECC errors rising rapidly on one DIMM. “Isolate and replace the DIMM with the increasing corrected-error count after preserving work.” is the appropriate response because growing ECC-corrected error counts can signal a degrading memory module even before uncorrectable failures.

C:

A CPU may fit its socket yet need updated firmware microcode to initialize. That does not directly address the condition described—A workstation intermittently corrupts memory under load, and firmware event logs reveal corrected ECC errors rising rapidly on one DIMM. “Isolate and replace the DIMM with the increasing corrected-error count after preserving work.” is the appropriate response because growing ECC-corrected error counts can signal a degrading memory module even before uncorrectable failures.

D:

Memory timing instability can create errors even when physical DIMMs are healthy. That does not directly address the condition described—A workstation intermittently corrupts memory under load, and firmware event logs reveal corrected ECC errors rising rapidly on one DIMM. “Isolate and replace the DIMM with the increasing corrected-error count after preserving work.” is the appropriate response because growing ECC-corrected error counts can signal a degrading memory module even before uncorrectable failures.

Question 898

A workstation intermittently corrupts memory under load, and firmware event logs reveal corrected ECC errors rising rapidly on one DIMM. How should the technician verify the corrective change?

  1. POST completes and a memory diagnostic reports no installation errors.
  2. The system completes memory stress tests and corrected-error counters remain stable.
  3. Firmware reports fan RPM and CPU temperatures stay within limits under load.
  4. Input voltage stays acceptable during appliance starts and the PC remains stable.

Explanation

Correct Answer

B:

Growing ECC-corrected error counts can signal a degrading memory module even before uncorrectable failures. The outcome “The system completes memory stress tests and corrected-error counters remain stable.” verifies the action “Isolate and replace the DIMM with the increasing corrected-error count after preserving work.” for this situation: A workstation intermittently corrupts memory under load, and firmware event logs reveal corrected ECC errors rising rapidly on one DIMM.

Incorrect Answers

A:

Incomplete DIMM seating interrupts electrical contact and can prevent memory training. For the situation described—A workstation intermittently corrupts memory under load, and firmware event logs reveal corrected ECC errors rising rapidly on one DIMM—this would not demonstrate the specified intervention. The relevant evidence is “The system completes memory stress tests and corrected-error counters remain stable.”.

C:

A CPU cooler that does not report or deliver cooling can trigger protective shutdown. For the situation described—A workstation intermittently corrupts memory under load, and firmware event logs reveal corrected ECC errors rising rapidly on one DIMM—this would not demonstrate the specified intervention. The relevant evidence is “The system completes memory stress tests and corrected-error counters remain stable.”.

D:

Brownouts interrupt stable input power even when internal components are healthy. For the situation described—A workstation intermittently corrupts memory under load, and firmware event logs reveal corrected ECC errors rising rapidly on one DIMM—this would not demonstrate the specified intervention. The relevant evidence is “The system completes memory stress tests and corrected-error counters remain stable.”.

Question 899

A technician notices a new tower motherboard shorting against an extra chassis standoff near an empty screw hole. Which intervention is best supported by the evidence?

  1. Remove the unused standoff and mount the motherboard only on supported points.
  2. Reconnect the chassis controls to the motherboard's documented headers.
  3. Disable the unsupported overclock and restore a verified memory timing profile.
  4. Check firmware support and upgrade to a compatible motherboard BIOS if appropriate.

Explanation

Correct Answer

A:

An unmatched metal standoff can contact circuit traces and short the board. In this situation—A technician notices a new tower motherboard shorting against an extra chassis standoff near an empty screw hole—the right response is “Remove the unused standoff and mount the motherboard only on supported points.”. A confirming result would be “The machine powers through POST without short-circuit shutdown.”.

Incorrect Answers

B:

Miswired front-panel headers cause misleading power/reset behavior. That does not directly address the condition described—A technician notices a new tower motherboard shorting against an extra chassis standoff near an empty screw hole. “Remove the unused standoff and mount the motherboard only on supported points.” is the appropriate response because an unmatched metal standoff can contact circuit traces and short the board.

C:

Memory timing instability can create errors even when physical DIMMs are healthy. That does not directly address the condition described—A technician notices a new tower motherboard shorting against an extra chassis standoff near an empty screw hole. “Remove the unused standoff and mount the motherboard only on supported points.” is the appropriate response because an unmatched metal standoff can contact circuit traces and short the board.

D:

A CPU may fit its socket yet need updated firmware microcode to initialize. That does not directly address the condition described—A technician notices a new tower motherboard shorting against an extra chassis standoff near an empty screw hole. “Remove the unused standoff and mount the motherboard only on supported points.” is the appropriate response because an unmatched metal standoff can contact circuit traces and short the board.

Question 900

A technician notices a new tower motherboard shorting against an extra chassis standoff near an empty screw hole. Which test outcome demonstrates that the chosen action worked?

  1. Fan speeds and component temperature remain stable during load.
  2. A known-good load works at the outlet and the PC then powers on.
  3. The machine powers through POST without short-circuit shutdown.
  4. A representative GPU/CPU stress test completes without shutdown.

Explanation

Correct Answer

C:

An unmatched metal standoff can contact circuit traces and short the board. The outcome “The machine powers through POST without short-circuit shutdown.” verifies the action “Remove the unused standoff and mount the motherboard only on supported points.” for this situation: A technician notices a new tower motherboard shorting against an extra chassis standoff near an empty screw hole.

Incorrect Answers

A:

Blocked airflow can raise chassis and component temperatures. For the situation described—A technician notices a new tower motherboard shorting against an extra chassis standoff near an empty screw hole—this would not demonstrate the specified intervention. The relevant evidence is “The machine powers through POST without short-circuit shutdown.”.

B:

Absence of mains power explains all loss of standby indicators. For the situation described—A technician notices a new tower motherboard shorting against an extra chassis standoff near an empty screw hole—this would not demonstrate the specified intervention. The relevant evidence is “The machine powers through POST without short-circuit shutdown.”.

D:

High-load shutdown can indicate inadequate power delivery. For the situation described—A technician notices a new tower motherboard shorting against an extra chassis standoff near an empty screw hole—this would not demonstrate the specified intervention. The relevant evidence is “The machine powers through POST without short-circuit shutdown.”.