McAfee-Secured Website

Exam Bundle

Exam Code: 220-1201

Exam Name CompTIA A+ Certification Exam: Core 1

Certification Provider: CompTIA

Corresponding Certification: CompTIA A+

CompTIA 220-1201 Bundle $44.99

100% CompTIA 220-1201 Guaranteed Success With Testking Training Materials

Get Real 220-1201 Exam Questions & Expert Verified Answers as Experienced on the Real Exam!

  • Questions & Answers

    220-1201 Questions & Answers

    527 Questions & Answers

    The ultimate exam preparation tool, Questions & Answers mirrors the actual 220-1201 exam while allowing you to hone and measure every aspect of your test-taking ability.

  • 220-1201 Video Course

    220-1201 Video Course

    106 Video Lectures

    220-1201 Video Course is developed by CompTIA Professionals to help you pass the 220-1201 exam.

    Description

    This course will improve your knowledge and skills required to pass CompTIA A+ Certification Exam: Core 1 exam.
  • Study Guide

    220-1201 Study Guide

    2615 PDF Pages

    Developed by industry experts, this 2615-page guide spells out in painstaking detail all of the information you need to ace 220-1201 exam.

CompTIA A+ Certification Exam: Core 1 (220-1201) Practice Tests

Satisfaction Guaranteed

Money Back Guarantee

Testking provides hassle-free money back guarantee with our products. That is because we have 100% trust in the abilities of our professional and experience product team, and our record is a proof of that.

99.6% PASS RATE
Total Cost: $194.97
Bundle Price: $149.98

Purchase Individually

  • Questions & Answers

    Questions & Answers

    527 Questions

    $124.99
  • 220-1201 Video Course

    Video Course

    106 Video Lectures

    $39.99
  • Study Guide

    Study Guide

    2615 PDF Pages

    $29.99

CompTIA 220-1201 Practice Test 94

Question 930

A workstation's external monitor says 'No Signal' after a user changed input from HDMI to DisplayPort, while HDMI remains connected. Which test outcome demonstrates that the chosen action worked?

  1. The projector shows the laptop output without cable replacement.
  2. The complete desktop boundary and test patterns fit the visible screen.
  3. The internal panel reaches normal brightness independently of HDMI.
  4. The desktop reappears with the existing cable and graphics settings.

Explanation

Correct Answer

D:

An incorrect monitor input selection hides a valid incoming video signal. The outcome “The desktop reappears with the existing cable and graphics settings.” verifies the action “Select the HDMI source on the monitor's input menu.” for this situation: A workstation's external monitor says 'No Signal' after a user changed input from HDMI to DisplayPort, while HDMI remains connected.

Incorrect Answers

A:

A correct signal on the wrong selected input appears absent. For the situation described—A workstation's external monitor says 'No Signal' after a user changed input from HDMI to DisplayPort, while HDMI remains connected—this would not demonstrate the specified intervention. The relevant evidence is “The desktop reappears with the existing cable and graphics settings.”.

B:

Incorrect video scaling can crop pixels despite a working monitor. For the situation described—A workstation's external monitor says 'No Signal' after a user changed input from HDMI to DisplayPort, while HDMI remains connected—this would not demonstrate the specified intervention. The relevant evidence is “The desktop reappears with the existing cable and graphics settings.”.

C:

A faint image indicates video data is present but illumination is absent. For the situation described—A workstation's external monitor says 'No Signal' after a user changed input from HDMI to DisplayPort, while HDMI remains connected—this would not demonstrate the specified intervention. The relevant evidence is “The desktop reappears with the existing cable and graphics settings.”.

Question 931

A laptop panel becomes dark during lid movement while an external display remains uninterrupted. Which action most directly addresses this problem?

  1. Inspect and replace the damaged internal hinge-routed display cable.
  2. Use the vendor's pixel defect policy and replace if it meets criteria.
  3. Replace the defective cable with a compliant known-good lead.
  4. Return to the monitor's supported refresh rate and cable bandwidth.

Explanation

Correct Answer

A:

A flexing internal display cable can fail by hinge position without affecting external video. In this situation—A laptop panel becomes dark during lid movement while an external display remains uninterrupted—the right response is “Inspect and replace the damaged internal hinge-routed display cable.”. A confirming result would be “The internal image stays stable through repeated lid-angle adjustments.”.

Incorrect Answers

B:

A single stuck pixel is a panel-cell issue, not OS color calibration. That does not directly address the condition described—A laptop panel becomes dark during lid movement while an external display remains uninterrupted. “Inspect and replace the damaged internal hinge-routed display cable.” is the appropriate response because a flexing internal display cable can fail by hinge position without affecting external video.

C:

A damaged video connector can interrupt digital signal continuity. That does not directly address the condition described—A laptop panel becomes dark during lid movement while an external display remains uninterrupted. “Inspect and replace the damaged internal hinge-routed display cable.” is the appropriate response because a flexing internal display cable can fail by hinge position without affecting external video.

D:

An unstable high-refresh link can flicker when timing exceeds capability. That does not directly address the condition described—A laptop panel becomes dark during lid movement while an external display remains uninterrupted. “Inspect and replace the damaged internal hinge-routed display cable.” is the appropriate response because a flexing internal display cable can fail by hinge position without affecting external video.

Question 932

A laptop panel becomes dark during lid movement while an external display remains uninterrupted. Which result BEST confirms the problem has been resolved?

  1. The display maintains the desired resolution and refresh with no flicker.
  2. The internal image stays stable through repeated lid-angle adjustments.
  3. The internal panel reaches normal brightness independently of HDMI.
  4. The complete desktop boundary and test patterns fit the visible screen.

Explanation

Correct Answer

B:

A flexing internal display cable can fail by hinge position without affecting external video. The outcome “The internal image stays stable through repeated lid-angle adjustments.” verifies the action “Inspect and replace the damaged internal hinge-routed display cable.” for this situation: A laptop panel becomes dark during lid movement while an external display remains uninterrupted.

Incorrect Answers

A:

High pixel throughput can exceed video cable or adapter bandwidth even when lower modes work. For the situation described—A laptop panel becomes dark during lid movement while an external display remains uninterrupted—this would not demonstrate the specified intervention. The relevant evidence is “The internal image stays stable through repeated lid-angle adjustments.”.

C:

A faint image indicates video data is present but illumination is absent. For the situation described—A laptop panel becomes dark during lid movement while an external display remains uninterrupted—this would not demonstrate the specified intervention. The relevant evidence is “The internal image stays stable through repeated lid-angle adjustments.”.

D:

Incorrect video scaling can crop pixels despite a working monitor. For the situation described—A laptop panel becomes dark during lid movement while an external display remains uninterrupted—this would not demonstrate the specified intervention. The relevant evidence is “The internal image stays stable through repeated lid-angle adjustments.”.

Question 933

A 4K display becomes intermittent at a high refresh rate but works reliably at 60 Hz over the same adapter. What is the MOST appropriate technician response?

  1. Match the GPU output quantization range with the display's accepted RGB level settings.
  2. Use a video cable and output interface rated for the requested high-bandwidth mode.
  3. Set the output to the display's native resolution and correct overscan/scaling.
  4. Return to the monitor's supported refresh rate and cable bandwidth.

Explanation

Correct Answer

B:

High pixel throughput can exceed video cable or adapter bandwidth even when lower modes work. In this situation—A 4K display becomes intermittent at a high refresh rate but works reliably at 60 Hz over the same adapter—the right response is “Use a video cable and output interface rated for the requested high-bandwidth mode.”. A confirming result would be “The display maintains the desired resolution and refresh with no flicker.”.

Incorrect Answers

A:

Mismatched video-level ranges distort luminance even when the HDMI image is stable. That does not directly address the condition described—A 4K display becomes intermittent at a high refresh rate but works reliably at 60 Hz over the same adapter. “Use a video cable and output interface rated for the requested high-bandwidth mode.” is the appropriate response because high pixel throughput can exceed video cable or adapter bandwidth even when lower modes work.

C:

Incorrect video scaling can crop pixels despite a working monitor. That does not directly address the condition described—A 4K display becomes intermittent at a high refresh rate but works reliably at 60 Hz over the same adapter. “Use a video cable and output interface rated for the requested high-bandwidth mode.” is the appropriate response because high pixel throughput can exceed video cable or adapter bandwidth even when lower modes work.

D:

An unstable high-refresh link can flicker when timing exceeds capability. That does not directly address the condition described—A 4K display becomes intermittent at a high refresh rate but works reliably at 60 Hz over the same adapter. “Use a video cable and output interface rated for the requested high-bandwidth mode.” is the appropriate response because high pixel throughput can exceed video cable or adapter bandwidth even when lower modes work.

Question 934

A 4K display becomes intermittent at a high refresh rate but works reliably at 60 Hz over the same adapter. Which observation directly verifies a successful repair?

  1. A new panel shows the specified solid-color patterns without the stuck pixel.
  2. The internal image stays stable through repeated lid-angle adjustments.
  3. The complete desktop boundary and test patterns fit the visible screen.
  4. The display maintains the desired resolution and refresh with no flicker.

Explanation

Correct Answer

D:

High pixel throughput can exceed video cable or adapter bandwidth even when lower modes work. The outcome “The display maintains the desired resolution and refresh with no flicker.” verifies the action “Use a video cable and output interface rated for the requested high-bandwidth mode.” for this situation: A 4K display becomes intermittent at a high refresh rate but works reliably at 60 Hz over the same adapter.

Incorrect Answers

A:

A single stuck pixel is a panel-cell issue, not OS color calibration. For the situation described—A 4K display becomes intermittent at a high refresh rate but works reliably at 60 Hz over the same adapter—this would not demonstrate the specified intervention. The relevant evidence is “The display maintains the desired resolution and refresh with no flicker.”.

B:

A flexing internal display cable can fail by hinge position without affecting external video. For the situation described—A 4K display becomes intermittent at a high refresh rate but works reliably at 60 Hz over the same adapter—this would not demonstrate the specified intervention. The relevant evidence is “The display maintains the desired resolution and refresh with no flicker.”.

C:

Incorrect video scaling can crop pixels despite a working monitor. For the situation described—A 4K display becomes intermittent at a high refresh rate but works reliably at 60 Hz over the same adapter—this would not demonstrate the specified intervention. The relevant evidence is “The display maintains the desired resolution and refresh with no flicker.”.

Question 935

A projector creates a trapezoidal picture because it is mounted off-axis to the projection screen. Which change best satisfies the stated requirement?

  1. Restore proper ventilation and clean or replace its specified cooling filters.
  2. Replace the aging lamp using the manufacturer's safe cooling procedure.
  3. Correct projector alignment and use supported keystone controls as necessary.
  4. Select an output resolution and scaling compatible with the projector.

Explanation

Correct Answer

C:

Projection angle produces keystone distortion independent of source pixel data. In this situation—A projector creates a trapezoidal picture because it is mounted off-axis to the projection screen—the right response is “Correct projector alignment and use supported keystone controls as necessary.”. A confirming result would be “Projected horizontal and vertical grid lines appear straight and rectangular.”.

Incorrect Answers

A:

Restricted projector airflow can trigger overtemperature shutdown to protect the lamp or optics. That does not directly address the condition described—A projector creates a trapezoidal picture because it is mounted off-axis to the projection screen. “Correct projector alignment and use supported keystone controls as necessary.” is the appropriate response because projection angle produces keystone distortion independent of source pixel data.

B:

Traditional projector lamps lose brightness and color accuracy as they age. That does not directly address the condition described—A projector creates a trapezoidal picture because it is mounted off-axis to the projection screen. “Correct projector alignment and use supported keystone controls as necessary.” is the appropriate response because projection angle produces keystone distortion independent of source pixel data.

D:

Display mode mismatch can crop or scale output incorrectly. That does not directly address the condition described—A projector creates a trapezoidal picture because it is mounted off-axis to the projection screen. “Correct projector alignment and use supported keystone controls as necessary.” is the appropriate response because projection angle produces keystone distortion independent of source pixel data.

Question 936

A projector creates a trapezoidal picture because it is mounted off-axis to the projection screen. What evidence shows that the intended requirement has been met?

  1. Projected horizontal and vertical grid lines appear straight and rectangular.
  2. A new panel shows the specified solid-color patterns without the stuck pixel.
  3. The display maintains the desired resolution and refresh with no flicker.
  4. Uniform gray test images no longer show a fixed toolbar shadow after remediation.

Explanation

Correct Answer

A:

Projection angle produces keystone distortion independent of source pixel data. The outcome “Projected horizontal and vertical grid lines appear straight and rectangular.” verifies the action “Correct projector alignment and use supported keystone controls as necessary.” for this situation: A projector creates a trapezoidal picture because it is mounted off-axis to the projection screen.

Incorrect Answers

B:

A single stuck pixel is a panel-cell issue, not OS color calibration. For the situation described—A projector creates a trapezoidal picture because it is mounted off-axis to the projection screen—this would not demonstrate the specified intervention. The relevant evidence is “Projected horizontal and vertical grid lines appear straight and rectangular.”.

C:

High pixel throughput can exceed video cable or adapter bandwidth even when lower modes work. For the situation described—A projector creates a trapezoidal picture because it is mounted off-axis to the projection screen—this would not demonstrate the specified intervention. The relevant evidence is “Projected horizontal and vertical grid lines appear straight and rectangular.”.

D:

Uneven OLED emitter aging can produce irreversible static-image burn-in. For the situation described—A projector creates a trapezoidal picture because it is mounted off-axis to the projection screen—this would not demonstrate the specified intervention. The relevant evidence is “Projected horizontal and vertical grid lines appear straight and rectangular.”.

Question 937

A new monitor displays clipped text because its graphics driver is set to an incompatible overscan mode. What should the technician configure or repair to resolve this issue?

  1. Select an output resolution and scaling compatible with the projector.
  2. Use a video cable and output interface rated for the requested high-bandwidth mode.
  3. Match the GPU output quantization range with the display's accepted RGB level settings.
  4. Set the output to the display's native resolution and correct overscan/scaling.

Explanation

Correct Answer

D:

Incorrect video scaling can crop pixels despite a working monitor. In this situation—A new monitor displays clipped text because its graphics driver is set to an incompatible overscan mode—the right response is “Set the output to the display's native resolution and correct overscan/scaling.”. A confirming result would be “The complete desktop boundary and test patterns fit the visible screen.”.

Incorrect Answers

A:

Display mode mismatch can crop or scale output incorrectly. That does not directly address the condition described—A new monitor displays clipped text because its graphics driver is set to an incompatible overscan mode. “Set the output to the display's native resolution and correct overscan/scaling.” is the appropriate response because incorrect video scaling can crop pixels despite a working monitor.

B:

High pixel throughput can exceed video cable or adapter bandwidth even when lower modes work. That does not directly address the condition described—A new monitor displays clipped text because its graphics driver is set to an incompatible overscan mode. “Set the output to the display's native resolution and correct overscan/scaling.” is the appropriate response because incorrect video scaling can crop pixels despite a working monitor.

C:

Mismatched video-level ranges distort luminance even when the HDMI image is stable. That does not directly address the condition described—A new monitor displays clipped text because its graphics driver is set to an incompatible overscan mode. “Set the output to the display's native resolution and correct overscan/scaling.” is the appropriate response because incorrect video scaling can crop pixels despite a working monitor.

Question 938

A new monitor displays clipped text because its graphics driver is set to an incompatible overscan mode. How should the technician verify the corrective change?

  1. The display maintains the desired resolution and refresh with no flicker.
  2. The internal image stays stable through repeated lid-angle adjustments.
  3. The complete desktop boundary and test patterns fit the visible screen.
  4. The desktop reappears with the existing cable and graphics settings.

Explanation

Correct Answer

C:

Incorrect video scaling can crop pixels despite a working monitor. The outcome “The complete desktop boundary and test patterns fit the visible screen.” verifies the action “Set the output to the display's native resolution and correct overscan/scaling.” for this situation: A new monitor displays clipped text because its graphics driver is set to an incompatible overscan mode.

Incorrect Answers

A:

High pixel throughput can exceed video cable or adapter bandwidth even when lower modes work. For the situation described—A new monitor displays clipped text because its graphics driver is set to an incompatible overscan mode—this would not demonstrate the specified intervention. The relevant evidence is “The complete desktop boundary and test patterns fit the visible screen.”.

B:

A flexing internal display cable can fail by hinge position without affecting external video. For the situation described—A new monitor displays clipped text because its graphics driver is set to an incompatible overscan mode—this would not demonstrate the specified intervention. The relevant evidence is “The complete desktop boundary and test patterns fit the visible screen.”.

D:

An incorrect monitor input selection hides a valid incoming video signal. For the situation described—A new monitor displays clipped text because its graphics driver is set to an incompatible overscan mode—this would not demonstrate the specified intervention. The relevant evidence is “The complete desktop boundary and test patterns fit the visible screen.”.

Question 939

A desktop OLED shows a permanent toolbar outline after running one static dashboard for months. Which intervention is best supported by the evidence?

  1. Apply pixel-refresh/content-management guidance or replace the aged panel.
  2. Use a video cable and output interface rated for the requested high-bandwidth mode.
  3. Match the GPU output quantization range with the display's accepted RGB level settings.
  4. Apply approved image-retention mitigation and replace the panel if persistent burn-in remains.

Explanation

Correct Answer

D:

Uneven OLED emitter aging can produce irreversible static-image burn-in. In this situation—A desktop OLED shows a permanent toolbar outline after running one static dashboard for months—the right response is “Apply approved image-retention mitigation and replace the panel if persistent burn-in remains.”. A confirming result would be “Uniform gray test images no longer show a fixed toolbar shadow after remediation.”.

Incorrect Answers

A:

Uneven OLED wear can cause lasting image retention. That does not directly address the condition described—A desktop OLED shows a permanent toolbar outline after running one static dashboard for months. “Apply approved image-retention mitigation and replace the panel if persistent burn-in remains.” is the appropriate response because uneven OLED emitter aging can produce irreversible static-image burn-in.

B:

High pixel throughput can exceed video cable or adapter bandwidth even when lower modes work. That does not directly address the condition described—A desktop OLED shows a permanent toolbar outline after running one static dashboard for months. “Apply approved image-retention mitigation and replace the panel if persistent burn-in remains.” is the appropriate response because uneven OLED emitter aging can produce irreversible static-image burn-in.

C:

Mismatched video-level ranges distort luminance even when the HDMI image is stable. That does not directly address the condition described—A desktop OLED shows a permanent toolbar outline after running one static dashboard for months. “Apply approved image-retention mitigation and replace the panel if persistent burn-in remains.” is the appropriate response because uneven OLED emitter aging can produce irreversible static-image burn-in.

Question 940

A desktop OLED shows a permanent toolbar outline after running one static dashboard for months. Which test outcome demonstrates that the chosen action worked?

  1. Uniform gray test images no longer show a fixed toolbar shadow after remediation.
  2. Black and white level patterns show full detail without crushed or washed-out tones.
  3. A new panel shows the specified solid-color patterns without the stuck pixel.
  4. A uniform test field no longer displays a persistent logo outline.

Explanation

Correct Answer

A:

Uneven OLED emitter aging can produce irreversible static-image burn-in. The outcome “Uniform gray test images no longer show a fixed toolbar shadow after remediation.” verifies the action “Apply approved image-retention mitigation and replace the panel if persistent burn-in remains.” for this situation: A desktop OLED shows a permanent toolbar outline after running one static dashboard for months.

Incorrect Answers

B:

Mismatched video-level ranges distort luminance even when the HDMI image is stable. For the situation described—A desktop OLED shows a permanent toolbar outline after running one static dashboard for months—this would not demonstrate the specified intervention. The relevant evidence is “Uniform gray test images no longer show a fixed toolbar shadow after remediation.”.

C:

A single stuck pixel is a panel-cell issue, not OS color calibration. For the situation described—A desktop OLED shows a permanent toolbar outline after running one static dashboard for months—this would not demonstrate the specified intervention. The relevant evidence is “Uniform gray test images no longer show a fixed toolbar shadow after remediation.”.

D:

Uneven OLED wear can cause lasting image retention. For the situation described—A desktop OLED shows a permanent toolbar outline after running one static dashboard for months—this would not demonstrate the specified intervention. The relevant evidence is “Uniform gray test images no longer show a fixed toolbar shadow after remediation.”.