McAfee-Secured Website

Exam Bundle

Exam Code: 220-1201

Exam Name CompTIA A+ Certification Exam: Core 1

Certification Provider: CompTIA

Corresponding Certification: CompTIA A+

CompTIA 220-1201 Bundle $44.99

100% CompTIA 220-1201 Guaranteed Success With Testking Training Materials

Get Real 220-1201 Exam Questions & Expert Verified Answers as Experienced on the Real Exam!

  • Questions & Answers

    220-1201 Questions & Answers

    527 Questions & Answers

    The ultimate exam preparation tool, Questions & Answers mirrors the actual 220-1201 exam while allowing you to hone and measure every aspect of your test-taking ability.

  • 220-1201 Video Course

    220-1201 Video Course

    106 Video Lectures

    220-1201 Video Course is developed by CompTIA Professionals to help you pass the 220-1201 exam.

    Description

    This course will improve your knowledge and skills required to pass CompTIA A+ Certification Exam: Core 1 exam.
  • Study Guide

    220-1201 Study Guide

    2615 PDF Pages

    Developed by industry experts, this 2615-page guide spells out in painstaking detail all of the information you need to ace 220-1201 exam.

CompTIA A+ Certification Exam: Core 1 (220-1201) Practice Tests

Satisfaction Guaranteed

Money Back Guarantee

Testking provides hassle-free money back guarantee with our products. That is because we have 100% trust in the abilities of our professional and experience product team, and our record is a proof of that.

99.6% PASS RATE
Total Cost: $194.97
Bundle Price: $149.98

Purchase Individually

  • Questions & Answers

    Questions & Answers

    527 Questions

    $124.99
  • 220-1201 Video Course

    Video Course

    106 Video Lectures

    $39.99
  • Study Guide

    Study Guide

    2615 PDF Pages

    $29.99

CompTIA 220-1201 Practice Test 77

Question 760

A 130-meter passive copper Ethernet run between switches is unreliable despite normal connectors. Which test outcome demonstrates that the chosen action worked?

  1. The resulting link operates within supported length and loss limits.
  2. Both transceivers establish optical link at expected receive power.
  3. A 1000BASE-T test negotiates gigabit with acceptable pair integrity.
  4. Link errors fall after the cable and shield termination are verified.

Explanation

Correct Answer

A:

Conventional copper Ethernet channel reach is typically limited to around 100 meters. The outcome “The resulting link operates within supported length and loss limits.” verifies the action “Use standards-compliant cable segments with an intermediate active device or fiber path.” for this situation: A 130-meter passive copper Ethernet run between switches is unreliable despite normal connectors.

Incorrect Answers

B:

LC and SC are different fiber connector geometries and require compatible mating interfaces. For the situation described—A 130-meter passive copper Ethernet run between switches is unreliable despite normal connectors—this would not demonstrate the specified intervention. The relevant evidence is “The resulting link operates within supported length and loss limits.”.

C:

Gigabit copper Ethernet requires suitable four-pair cabling rather than ordinary flat telephone cord. For the situation described—A 130-meter passive copper Ethernet run between switches is unreliable despite normal connectors—this would not demonstrate the specified intervention. The relevant evidence is “The resulting link operates within supported length and loss limits.”.

D:

Shielding can mitigate electromagnetic interference when installed correctly. For the situation described—A 130-meter passive copper Ethernet run between switches is unreliable despite normal connectors—this would not demonstrate the specified intervention. The relevant evidence is “The resulting link operates within supported length and loss limits.”.

Question 761

A new desktop motherboard offers a USB 3.2 port but the attached USB 2.0 cable prevents expected high transfer rates. Which action most directly addresses this problem?

  1. Use a cable and peripherals rated for the target USB data mode.
  2. Select an appropriately rated outdoor/direct-burial cable assembly.
  3. Select cable rated for the applicable plenum installation requirements.
  4. Use a SATA data cable plus a compatible SATA power connector.

Explanation

Correct Answer

A:

USB throughput is constrained by the slowest supported host, cable, or peripheral element. In this situation—A new desktop motherboard offers a USB 3.2 port but the attached USB 2.0 cable prevents expected high transfer rates—the right response is “Use a cable and peripherals rated for the target USB data mode.”. A confirming result would be “The negotiated link and file-copy measurement reach the supported speed range.”.

Incorrect Answers

B:

Indoor patch cable jackets are not designed for direct wet burial. That does not directly address the condition described—A new desktop motherboard offers a USB 3.2 port but the attached USB 2.0 cable prevents expected high transfer rates. “Use a cable and peripherals rated for the target USB data mode.” is the appropriate response because uSB throughput is constrained by the slowest supported host, cable, or peripheral element.

C:

Plenum spaces require cable jackets meeting elevated fire/smoke safety rules. That does not directly address the condition described—A new desktop motherboard offers a USB 3.2 port but the attached USB 2.0 cable prevents expected high transfer rates. “Use a cable and peripherals rated for the target USB data mode.” is the appropriate response because uSB throughput is constrained by the slowest supported host, cable, or peripheral element.

D:

SATA drives use separate data and power connections. That does not directly address the condition described—A new desktop motherboard offers a USB 3.2 port but the attached USB 2.0 cable prevents expected high transfer rates. “Use a cable and peripherals rated for the target USB data mode.” is the appropriate response because uSB throughput is constrained by the slowest supported host, cable, or peripheral element.

Question 762

A new desktop motherboard offers a USB 3.2 port but the attached USB 2.0 cable prevents expected high transfer rates. Which result BEST confirms the problem has been resolved?

  1. The negotiated link and file-copy measurement reach the supported speed range.
  2. The display maintains the full required video mode with no intermittency.
  3. The video or RF feed appears without reflection or intermittent coax connection.
  4. The cable jacket markings satisfy the installation code and inspection.

Explanation

Correct Answer

A:

USB throughput is constrained by the slowest supported host, cable, or peripheral element. The outcome “The negotiated link and file-copy measurement reach the supported speed range.” verifies the action “Use a cable and peripherals rated for the target USB data mode.” for this situation: A new desktop motherboard offers a USB 3.2 port but the attached USB 2.0 cable prevents expected high transfer rates.

Incorrect Answers

B:

Long high-bandwidth HDMI connections may require active signal management or optical cabling. For the situation described—A new desktop motherboard offers a USB 3.2 port but the attached USB 2.0 cable prevents expected high transfer rates—this would not demonstrate the specified intervention. The relevant evidence is “The negotiated link and file-copy measurement reach the supported speed range.”.

C:

Coaxial systems use impedance-controlled connectors such as BNC, not twisted-pair Ethernet jacks. For the situation described—A new desktop motherboard offers a USB 3.2 port but the attached USB 2.0 cable prevents expected high transfer rates—this would not demonstrate the specified intervention. The relevant evidence is “The negotiated link and file-copy measurement reach the supported speed range.”.

D:

Plenum spaces require cable jackets meeting elevated fire/smoke safety rules. For the situation described—A new desktop motherboard offers a USB 3.2 port but the attached USB 2.0 cable prevents expected high transfer rates—this would not demonstrate the specified intervention. The relevant evidence is “The negotiated link and file-copy measurement reach the supported speed range.”.

Question 763

A site requires high-speed video over a long HDMI run and the present passive cable loses signal at native resolution. What is the MOST appropriate technician response?

  1. Use properly grounded shielded cabling where required by the design.
  2. Use the correct RJ45-style 8P8C jack wired to the selected T568 scheme.
  3. Use a properly rated active optical HDMI solution for the needed distance.
  4. Select cable rated for the applicable plenum installation requirements.

Explanation

Correct Answer

C:

Long high-bandwidth HDMI connections may require active signal management or optical cabling. In this situation—A site requires high-speed video over a long HDMI run and the present passive cable loses signal at native resolution—the right response is “Use a properly rated active optical HDMI solution for the needed distance.”. A confirming result would be “The display maintains the full required video mode with no intermittency.”.

Incorrect Answers

A:

Shielding can mitigate electromagnetic interference when installed correctly. That does not directly address the condition described—A site requires high-speed video over a long HDMI run and the present passive cable loses signal at native resolution. “Use a properly rated active optical HDMI solution for the needed distance.” is the appropriate response because long high-bandwidth HDMI connections may require active signal management or optical cabling.

B:

Ethernet twisted pair normally terminates in 8-position modular interfaces. That does not directly address the condition described—A site requires high-speed video over a long HDMI run and the present passive cable loses signal at native resolution. “Use a properly rated active optical HDMI solution for the needed distance.” is the appropriate response because long high-bandwidth HDMI connections may require active signal management or optical cabling.

D:

Plenum spaces require cable jackets meeting elevated fire/smoke safety rules. That does not directly address the condition described—A site requires high-speed video over a long HDMI run and the present passive cable loses signal at native resolution. “Use a properly rated active optical HDMI solution for the needed distance.” is the appropriate response because long high-bandwidth HDMI connections may require active signal management or optical cabling.

Question 764

A site requires high-speed video over a long HDMI run and the present passive cable loses signal at native resolution. Which observation directly verifies a successful repair?

  1. The projector displays a correctly scaled image without sync errors.
  2. Link errors fall after the cable and shield termination are verified.
  3. The display maintains the full required video mode with no intermittency.
  4. The jacket and installation inspection confirm water and UV suitability.

Explanation

Correct Answer

C:

Long high-bandwidth HDMI connections may require active signal management or optical cabling. The outcome “The display maintains the full required video mode with no intermittency.” verifies the action “Use a properly rated active optical HDMI solution for the needed distance.” for this situation: A site requires high-speed video over a long HDMI run and the present passive cable loses signal at native resolution.

Incorrect Answers

A:

VGA is analog and may require active conversion from digital-only outputs. For the situation described—A site requires high-speed video over a long HDMI run and the present passive cable loses signal at native resolution—this would not demonstrate the specified intervention. The relevant evidence is “The display maintains the full required video mode with no intermittency.”.

B:

Shielding can mitigate electromagnetic interference when installed correctly. For the situation described—A site requires high-speed video over a long HDMI run and the present passive cable loses signal at native resolution—this would not demonstrate the specified intervention. The relevant evidence is “The display maintains the full required video mode with no intermittency.”.

D:

Indoor patch cable jackets are not designed for direct wet burial. For the situation described—A site requires high-speed video over a long HDMI run and the present passive cable loses signal at native resolution—this would not demonstrate the specified intervention. The relevant evidence is “The display maintains the full required video mode with no intermittency.”.

Question 765

A technician terminates a BNC connector on a CCTV coaxial run but incorrectly substitutes an RJ45 wall jack. Which change best satisfies the stated requirement?

  1. Use the correct RJ45-style 8P8C jack wired to the selected T568 scheme.
  2. Re-terminate both ends to the intended matching pinout for a straight-through run.
  3. Replace it with correctly rated four-pair twisted-pair Ethernet cable and termination.
  4. Use the connector and impedance rating specified for the coaxial camera system.

Explanation

Correct Answer

D:

Coaxial systems use impedance-controlled connectors such as BNC, not twisted-pair Ethernet jacks. In this situation—A technician terminates a BNC connector on a CCTV coaxial run but incorrectly substitutes an RJ45 wall jack—the right response is “Use the connector and impedance rating specified for the coaxial camera system.”. A confirming result would be “The video or RF feed appears without reflection or intermittent coax connection.”.

Incorrect Answers

A:

Ethernet twisted pair normally terminates in 8-position modular interfaces. That does not directly address the condition described—A technician terminates a BNC connector on a CCTV coaxial run but incorrectly substitutes an RJ45 wall jack. “Use the connector and impedance rating specified for the coaxial camera system.” is the appropriate response because coaxial systems use impedance-controlled connectors such as BNC, not twisted-pair Ethernet jacks.

B:

Mixed T568A and T568B terminations form a crossover wiring pattern. That does not directly address the condition described—A technician terminates a BNC connector on a CCTV coaxial run but incorrectly substitutes an RJ45 wall jack. “Use the connector and impedance rating specified for the coaxial camera system.” is the appropriate response because coaxial systems use impedance-controlled connectors such as BNC, not twisted-pair Ethernet jacks.

C:

Gigabit copper Ethernet requires suitable four-pair cabling rather than ordinary flat telephone cord. That does not directly address the condition described—A technician terminates a BNC connector on a CCTV coaxial run but incorrectly substitutes an RJ45 wall jack. “Use the connector and impedance rating specified for the coaxial camera system.” is the appropriate response because coaxial systems use impedance-controlled connectors such as BNC, not twisted-pair Ethernet jacks.

Question 766

A technician terminates a BNC connector on a CCTV coaxial run but incorrectly substitutes an RJ45 wall jack. What evidence shows that the intended requirement has been met?

  1. The display maintains the full required video mode with no intermittency.
  2. The negotiated link and file-copy measurement reach the supported speed range.
  3. A 1000BASE-T test negotiates gigabit with acceptable pair integrity.
  4. The video or RF feed appears without reflection or intermittent coax connection.

Explanation

Correct Answer

D:

Coaxial systems use impedance-controlled connectors such as BNC, not twisted-pair Ethernet jacks. The outcome “The video or RF feed appears without reflection or intermittent coax connection.” verifies the action “Use the connector and impedance rating specified for the coaxial camera system.” for this situation: A technician terminates a BNC connector on a CCTV coaxial run but incorrectly substitutes an RJ45 wall jack.

Incorrect Answers

A:

Long high-bandwidth HDMI connections may require active signal management or optical cabling. For the situation described—A technician terminates a BNC connector on a CCTV coaxial run but incorrectly substitutes an RJ45 wall jack—this would not demonstrate the specified intervention. The relevant evidence is “The video or RF feed appears without reflection or intermittent coax connection.”.

B:

USB throughput is constrained by the slowest supported host, cable, or peripheral element. For the situation described—A technician terminates a BNC connector on a CCTV coaxial run but incorrectly substitutes an RJ45 wall jack—this would not demonstrate the specified intervention. The relevant evidence is “The video or RF feed appears without reflection or intermittent coax connection.”.

C:

Gigabit copper Ethernet requires suitable four-pair cabling rather than ordinary flat telephone cord. For the situation described—A technician terminates a BNC connector on a CCTV coaxial run but incorrectly substitutes an RJ45 wall jack—this would not demonstrate the specified intervention. The relevant evidence is “The video or RF feed appears without reflection or intermittent coax connection.”.

Question 767

Two rack devices have only old RS-232 console ports, and a technician reaches for a standard Ethernet patch cable as a serial link. What should the technician configure or repair to resolve this issue?

  1. Choose a fiber patch lead or approved adapter with matching connector types and polish.
  2. Use standards-compliant cable segments with an intermediate active device or fiber path.
  3. Replace it with correctly rated four-pair twisted-pair Ethernet cable and termination.
  4. Use the specified RS-232 serial/console lead and supported USB-serial adapter if needed.

Explanation

Correct Answer

D:

RS-232 serial pinouts and signaling differ from ordinary Ethernet data cabling. In this situation—Two rack devices have only old RS-232 console ports, and a technician reaches for a standard Ethernet patch cable as a serial link—the right response is “Use the specified RS-232 serial/console lead and supported USB-serial adapter if needed.”. A confirming result would be “Console text appears at the correct terminal settings.”.

Incorrect Answers

A:

LC and SC are different fiber connector geometries and require compatible mating interfaces. That does not directly address the condition described—Two rack devices have only old RS-232 console ports, and a technician reaches for a standard Ethernet patch cable as a serial link. “Use the specified RS-232 serial/console lead and supported USB-serial adapter if needed.” is the appropriate response because rS-232 serial pinouts and signaling differ from ordinary Ethernet data cabling.

B:

Conventional copper Ethernet channel reach is typically limited to around 100 meters. That does not directly address the condition described—Two rack devices have only old RS-232 console ports, and a technician reaches for a standard Ethernet patch cable as a serial link. “Use the specified RS-232 serial/console lead and supported USB-serial adapter if needed.” is the appropriate response because rS-232 serial pinouts and signaling differ from ordinary Ethernet data cabling.

C:

Gigabit copper Ethernet requires suitable four-pair cabling rather than ordinary flat telephone cord. That does not directly address the condition described—Two rack devices have only old RS-232 console ports, and a technician reaches for a standard Ethernet patch cable as a serial link. “Use the specified RS-232 serial/console lead and supported USB-serial adapter if needed.” is the appropriate response because rS-232 serial pinouts and signaling differ from ordinary Ethernet data cabling.

Question 768

Two rack devices have only old RS-232 console ports, and a technician reaches for a standard Ethernet patch cable as a serial link. How should the technician verify the corrective change?

  1. Console text appears at the correct terminal settings.
  2. The transceiver reports link with receive power in specification.
  3. A wiremap tester shows the expected 1-to-1 pair mapping.
  4. Firmware detects the drive after both connections are made.

Explanation

Correct Answer

A:

RS-232 serial pinouts and signaling differ from ordinary Ethernet data cabling. The outcome “Console text appears at the correct terminal settings.” verifies the action “Use the specified RS-232 serial/console lead and supported USB-serial adapter if needed.” for this situation: Two rack devices have only old RS-232 console ports, and a technician reaches for a standard Ethernet patch cable as a serial link.

Incorrect Answers

B:

Multimode optics and matching cabling suit short optical links. For the situation described—Two rack devices have only old RS-232 console ports, and a technician reaches for a standard Ethernet patch cable as a serial link—this would not demonstrate the specified intervention. The relevant evidence is “Console text appears at the correct terminal settings.”.

C:

Mixed T568A and T568B terminations form a crossover wiring pattern. For the situation described—Two rack devices have only old RS-232 console ports, and a technician reaches for a standard Ethernet patch cable as a serial link—this would not demonstrate the specified intervention. The relevant evidence is “Console text appears at the correct terminal settings.”.

D:

SATA drives use separate data and power connections. For the situation described—Two rack devices have only old RS-232 console ports, and a technician reaches for a standard Ethernet patch cable as a serial link—this would not demonstrate the specified intervention. The relevant evidence is “Console text appears at the correct terminal settings.”.

Question 769

An equipment room has a fiber patch cord with SC terminations but the switch transceiver expects LC plugs. Which intervention is best supported by the evidence?

  1. Replace it with correctly rated four-pair twisted-pair Ethernet cable and termination.
  2. Choose a fiber patch lead or approved adapter with matching connector types and polish.
  3. Use standards-compliant cable segments with an intermediate active device or fiber path.
  4. Use the specified RS-232 serial/console lead and supported USB-serial adapter if needed.

Explanation

Correct Answer

B:

LC and SC are different fiber connector geometries and require compatible mating interfaces. In this situation—An equipment room has a fiber patch cord with SC terminations but the switch transceiver expects LC plugs—the right response is “Choose a fiber patch lead or approved adapter with matching connector types and polish.”. A confirming result would be “Both transceivers establish optical link at expected receive power.”.

Incorrect Answers

A:

Gigabit copper Ethernet requires suitable four-pair cabling rather than ordinary flat telephone cord. That does not directly address the condition described—An equipment room has a fiber patch cord with SC terminations but the switch transceiver expects LC plugs. “Choose a fiber patch lead or approved adapter with matching connector types and polish.” is the appropriate response because lC and SC are different fiber connector geometries and require compatible mating interfaces.

C:

Conventional copper Ethernet channel reach is typically limited to around 100 meters. That does not directly address the condition described—An equipment room has a fiber patch cord with SC terminations but the switch transceiver expects LC plugs. “Choose a fiber patch lead or approved adapter with matching connector types and polish.” is the appropriate response because lC and SC are different fiber connector geometries and require compatible mating interfaces.

D:

RS-232 serial pinouts and signaling differ from ordinary Ethernet data cabling. That does not directly address the condition described—An equipment room has a fiber patch cord with SC terminations but the switch transceiver expects LC plugs. “Choose a fiber patch lead or approved adapter with matching connector types and polish.” is the appropriate response because lC and SC are different fiber connector geometries and require compatible mating interfaces.

Question 770

An equipment room has a fiber patch cord with SC terminations but the switch transceiver expects LC plugs. Which test outcome demonstrates that the chosen action worked?

  1. The resulting link operates within supported length and loss limits.
  2. Optical power and end-to-end link tests meet the distance budget.
  3. The transceiver reports link with receive power in specification.
  4. Both transceivers establish optical link at expected receive power.

Explanation

Correct Answer

D:

LC and SC are different fiber connector geometries and require compatible mating interfaces. The outcome “Both transceivers establish optical link at expected receive power.” verifies the action “Choose a fiber patch lead or approved adapter with matching connector types and polish.” for this situation: An equipment room has a fiber patch cord with SC terminations but the switch transceiver expects LC plugs.

Incorrect Answers

A:

Conventional copper Ethernet channel reach is typically limited to around 100 meters. For the situation described—An equipment room has a fiber patch cord with SC terminations but the switch transceiver expects LC plugs—this would not demonstrate the specified intervention. The relevant evidence is “Both transceivers establish optical link at expected receive power.”.

B:

Single-mode fiber supports longer high-speed runs than typical multimode links. For the situation described—An equipment room has a fiber patch cord with SC terminations but the switch transceiver expects LC plugs—this would not demonstrate the specified intervention. The relevant evidence is “Both transceivers establish optical link at expected receive power.”.

C:

Multimode optics and matching cabling suit short optical links. For the situation described—An equipment room has a fiber patch cord with SC terminations but the switch transceiver expects LC plugs—this would not demonstrate the specified intervention. The relevant evidence is “Both transceivers establish optical link at expected receive power.”.