McAfee-Secured Website

Exam Bundle

Exam Code: 220-1201

Exam Name CompTIA A+ Certification Exam: Core 1

Certification Provider: CompTIA

Corresponding Certification: CompTIA A+

CompTIA 220-1201 Bundle $44.99

100% CompTIA 220-1201 Guaranteed Success With Testking Training Materials

Get Real 220-1201 Exam Questions & Expert Verified Answers as Experienced on the Real Exam!

  • Questions & Answers

    220-1201 Questions & Answers

    527 Questions & Answers

    The ultimate exam preparation tool, Questions & Answers mirrors the actual 220-1201 exam while allowing you to hone and measure every aspect of your test-taking ability.

  • 220-1201 Video Course

    220-1201 Video Course

    106 Video Lectures

    220-1201 Video Course is developed by CompTIA Professionals to help you pass the 220-1201 exam.

    Description

    This course will improve your knowledge and skills required to pass CompTIA A+ Certification Exam: Core 1 exam.
  • Study Guide

    220-1201 Study Guide

    2615 PDF Pages

    Developed by industry experts, this 2615-page guide spells out in painstaking detail all of the information you need to ace 220-1201 exam.

CompTIA A+ Certification Exam: Core 1 (220-1201) Practice Tests

Satisfaction Guaranteed

Money Back Guarantee

Testking provides hassle-free money back guarantee with our products. That is because we have 100% trust in the abilities of our professional and experience product team, and our record is a proof of that.

99.6% PASS RATE
Total Cost: $194.97
Bundle Price: $149.98

Purchase Individually

  • Questions & Answers

    Questions & Answers

    527 Questions

    $124.99
  • 220-1201 Video Course

    Video Course

    106 Video Lectures

    $39.99
  • Study Guide

    Study Guide

    2615 PDF Pages

    $29.99

CompTIA 220-1201 Practice Test 79

Question 780

A desktop boots with 64 GB installed although a 96 GB upgrade is requested, and the board documentation limits total memory to 64 GB. Which test outcome demonstrates that the chosen action worked?

  1. Firmware reports the intended supported capacity without population warnings.
  2. Firmware enables ECC and reports corrected-error monitoring capability.
  3. Firmware reports the supported dual-channel layout and stability tests pass.
  4. The module seats without force and firmware detects the rated capacity.

Explanation

Correct Answer

A:

Board, CPU memory controller and firmware limits can cap recognized system memory. The outcome “Firmware reports the intended supported capacity without population warnings.” verifies the action “Choose a platform that supports the required memory capacity or stay within its limit.” for this situation: A desktop boots with 64 GB installed although a 96 GB upgrade is requested, and the board documentation limits total memory to 64 GB.

Incorrect Answers

B:

ECC memory and controller support protect against certain memory bit errors. For the situation described—A desktop boots with 64 GB installed although a 96 GB upgrade is requested, and the board documentation limits total memory to 64 GB—this would not demonstrate the specified intervention. The relevant evidence is “Firmware reports the intended supported capacity without population warnings.”.

C:

Memory channels are selected by controller slot mapping, not just matching module count. For the situation described—A desktop boots with 64 GB installed although a 96 GB upgrade is requested, and the board documentation limits total memory to 64 GB—this would not demonstrate the specified intervention. The relevant evidence is “Firmware reports the intended supported capacity without population warnings.”.

D:

Memory generation keying and electrical requirements outweigh matching capacity alone. For the situation described—A desktop boots with 64 GB installed although a 96 GB upgrade is requested, and the board documentation limits total memory to 64 GB—this would not demonstrate the specified intervention. The relevant evidence is “Firmware reports the intended supported capacity without population warnings.”.

Question 781

A PC boots slowly after unstable memory overclock settings are applied to unsupported DIMMs. Which action most directly addresses this problem?

  1. Install a compatible matched second DIMM in the paired slot.
  2. Install supported ECC memory with motherboard/CPU compatibility.
  3. Restore supported JEDEC timings or a qualified memory profile.
  4. Replace the order with compatible SO-DIMMs for the notebook.

Explanation

Correct Answer

C:

Aggressive memory timings can exceed controller or module stability margins. In this situation—A PC boots slowly after unstable memory overclock settings are applied to unsupported DIMMs—the right response is “Restore supported JEDEC timings or a qualified memory profile.”. A confirming result would be “POST and extended RAM stress tests complete with no timing errors.”.

Incorrect Answers

A:

Paired compatible modules can increase memory-channel bandwidth. That does not directly address the condition described—A PC boots slowly after unstable memory overclock settings are applied to unsupported DIMMs. “Restore supported JEDEC timings or a qualified memory profile.” is the appropriate response because aggressive memory timings can exceed controller or module stability margins.

B:

ECC needs compatible memory and platform support to correct bit errors. That does not directly address the condition described—A PC boots slowly after unstable memory overclock settings are applied to unsupported DIMMs. “Restore supported JEDEC timings or a qualified memory profile.” is the appropriate response because aggressive memory timings can exceed controller or module stability margins.

D:

SO-DIMMs are the compact module form commonly used in laptops. That does not directly address the condition described—A PC boots slowly after unstable memory overclock settings are applied to unsupported DIMMs. “Restore supported JEDEC timings or a qualified memory profile.” is the appropriate response because aggressive memory timings can exceed controller or module stability margins.

Question 782

A PC boots slowly after unstable memory overclock settings are applied to unsupported DIMMs. Which result BEST confirms the problem has been resolved?

  1. Firmware reports ECC enabled and diagnostic events are available.
  2. Firmware reports dual-channel operation and stability checks pass.
  3. POST and extended RAM stress tests complete with no timing errors.
  4. Server firmware accepts the configuration with no population faults.

Explanation

Correct Answer

C:

Aggressive memory timings can exceed controller or module stability margins. The outcome “POST and extended RAM stress tests complete with no timing errors.” verifies the action “Restore supported JEDEC timings or a qualified memory profile.” for this situation: A PC boots slowly after unstable memory overclock settings are applied to unsupported DIMMs.

Incorrect Answers

A:

ECC needs compatible memory and platform support to correct bit errors. For the situation described—A PC boots slowly after unstable memory overclock settings are applied to unsupported DIMMs—this would not demonstrate the specified intervention. The relevant evidence is “POST and extended RAM stress tests complete with no timing errors.”.

B:

Paired compatible modules can increase memory-channel bandwidth. For the situation described—A PC boots slowly after unstable memory overclock settings are applied to unsupported DIMMs—this would not demonstrate the specified intervention. The relevant evidence is “POST and extended RAM stress tests complete with no timing errors.”.

D:

RDIMM and UDIMM buffering designs generally cannot be mixed in a memory system. For the situation described—A PC boots slowly after unstable memory overclock settings are applied to unsupported DIMMs—this would not demonstrate the specified intervention. The relevant evidence is “POST and extended RAM stress tests complete with no timing errors.”.

Question 783

A server drive bay is engineered for tool-less hot-swap SATA/SAS disks, but a technician wants to remove the active boot volume without redundancy. What is the MOST appropriate technician response?

  1. Recover from a valid backup because that mirrored pair no longer has a surviving copy.
  2. Confirm array protection and approved maintenance procedure before removing any hot-swap member.
  3. Install a controller-compatible M.2 NVMe SSD with the correct key and length.
  4. Recover from an independent backup rather than expecting RAID 0 to survive the lost disk.

Explanation

Correct Answer

B:

A hot-swap connector alone does not make removal of an unprotected boot disk safe. In this situation—A server drive bay is engineered for tool-less hot-swap SATA/SAS disks, but a technician wants to remove the active boot volume without redundancy—the right response is “Confirm array protection and approved maintenance procedure before removing any hot-swap member.”. A confirming result would be “The controller maintains the intended volume state during a controlled replacement.”.

Incorrect Answers

A:

RAID 10 fault tolerance depends on which mirror members fail, not merely on total failed drive count. That does not directly address the condition described—A server drive bay is engineered for tool-less hot-swap SATA/SAS disks, but a technician wants to remove the active boot volume without redundancy. “Confirm array protection and approved maintenance procedure before removing any hot-swap member.” is the appropriate response because a hot-swap connector alone does not make removal of an unprotected boot disk safe.

C:

M.2 mechanical fit does not imply SATA support on PCIe-only sockets. That does not directly address the condition described—A server drive bay is engineered for tool-less hot-swap SATA/SAS disks, but a technician wants to remove the active boot volume without redundancy. “Confirm array protection and approved maintenance procedure before removing any hot-swap member.” is the appropriate response because a hot-swap connector alone does not make removal of an unprotected boot disk safe.

D:

RAID 0 stripes without parity or mirroring and has no single-disk fault tolerance. That does not directly address the condition described—A server drive bay is engineered for tool-less hot-swap SATA/SAS disks, but a technician wants to remove the active boot volume without redundancy. “Confirm array protection and approved maintenance procedure before removing any hot-swap member.” is the appropriate response because a hot-swap connector alone does not make removal of an unprotected boot disk safe.

Question 784

A server drive bay is engineered for tool-less hot-swap SATA/SAS disks, but a technician wants to remove the active boot volume without redundancy. Which observation directly verifies a successful repair?

  1. The controller shows a healthy array after rebuild without data corruption.
  2. The controller maintains the intended volume state during a controlled replacement.
  3. Controller reports striped mirrors and tests survive a permitted single-disk failure.
  4. Unplugging one test member in a controlled maintenance window leaves the array accessible.

Explanation

Correct Answer

B:

A hot-swap connector alone does not make removal of an unprotected boot disk safe. The outcome “The controller maintains the intended volume state during a controlled replacement.” verifies the action “Confirm array protection and approved maintenance procedure before removing any hot-swap member.” for this situation: A server drive bay is engineered for tool-less hot-swap SATA/SAS disks, but a technician wants to remove the active boot volume without redundancy.

Incorrect Answers

A:

RAID 5 generally tolerates one failed disk and rebuilds from distributed parity. For the situation described—A server drive bay is engineered for tool-less hot-swap SATA/SAS disks, but a technician wants to remove the active boot volume without redundancy—this would not demonstrate the specified intervention. The relevant evidence is “The controller maintains the intended volume state during a controlled replacement.”.

C:

RAID 10 stripes mirrored pairs, combining speed and redundancy. For the situation described—A server drive bay is engineered for tool-less hot-swap SATA/SAS disks, but a technician wants to remove the active boot volume without redundancy—this would not demonstrate the specified intervention. The relevant evidence is “The controller maintains the intended volume state during a controlled replacement.”.

D:

RAID 1 keeps a mirror copy on each member, though it is not backup. For the situation described—A server drive bay is engineered for tool-less hot-swap SATA/SAS disks, but a technician wants to remove the active boot volume without redundancy—this would not demonstrate the specified intervention. The relevant evidence is “The controller maintains the intended volume state during a controlled replacement.”.

Question 785

An application wants an SSD that fits a PCIe M.2 slot but the purchased M.2 SATA module is not detected. Which change best satisfies the stated requirement?

  1. Connect each SATA device to its own supported controller port and power feed.
  2. Install a controller-compatible M.2 NVMe SSD with the correct key and length.
  3. Select a drive with appropriate TBW/DWPD endurance and interface performance.
  4. Choose an M.2 NVMe device supported by the motherboard slot.

Explanation

Correct Answer

B:

M.2 mechanical fit does not imply SATA support on PCIe-only sockets. In this situation—An application wants an SSD that fits a PCIe M.2 slot but the purchased M.2 SATA module is not detected—the right response is “Install a controller-compatible M.2 NVMe SSD with the correct key and length.”. A confirming result would be “UEFI recognizes an NVMe controller and reads the drive reliably.”.

Incorrect Answers

A:

SATA uses point-to-point data channels rather than shared parallel ATA drive ribbons. That does not directly address the condition described—An application wants an SSD that fits a PCIe M.2 slot but the purchased M.2 SATA module is not detected. “Install a controller-compatible M.2 NVMe SSD with the correct key and length.” is the appropriate response because m.2 mechanical fit does not imply SATA support on PCIe-only sockets.

C:

SSD endurance depends on flash wear rating and write volume, not just nominal capacity. That does not directly address the condition described—An application wants an SSD that fits a PCIe M.2 slot but the purchased M.2 SATA module is not detected. “Install a controller-compatible M.2 NVMe SSD with the correct key and length.” is the appropriate response because m.2 mechanical fit does not imply SATA support on PCIe-only sockets.

D:

M.2 defines form factor; SATA and PCIe/NVMe are distinct protocols. That does not directly address the condition described—An application wants an SSD that fits a PCIe M.2 slot but the purchased M.2 SATA module is not detected. “Install a controller-compatible M.2 NVMe SSD with the correct key and length.” is the appropriate response because m.2 mechanical fit does not imply SATA support on PCIe-only sockets.

Question 786

An application wants an SSD that fits a PCIe M.2 slot but the purchased M.2 SATA module is not detected. What evidence shows that the intended requirement has been met?

  1. Firmware lists the NVMe device under PCIe/NVMe storage.
  2. Firmware enumerates the NVMe controller and boots from the selected device.
  3. UEFI recognizes an NVMe controller and reads the drive reliably.
  4. The SATA controller detects the drive and its volume passes file tests.

Explanation

Correct Answer

C:

M.2 mechanical fit does not imply SATA support on PCIe-only sockets. The outcome “UEFI recognizes an NVMe controller and reads the drive reliably.” verifies the action “Install a controller-compatible M.2 NVMe SSD with the correct key and length.” for this situation: An application wants an SSD that fits a PCIe M.2 slot but the purchased M.2 SATA module is not detected.

Incorrect Answers

A:

Most motherboard-mounted M.2 NVMe drives use the slot for data and power. For the situation described—An application wants an SSD that fits a PCIe M.2 slot but the purchased M.2 SATA module is not detected—this would not demonstrate the specified intervention. The relevant evidence is “UEFI recognizes an NVMe controller and reads the drive reliably.”.

B:

M.2 defines form factor; SATA and PCIe/NVMe are distinct protocols. For the situation described—An application wants an SSD that fits a PCIe M.2 slot but the purchased M.2 SATA module is not detected—this would not demonstrate the specified intervention. The relevant evidence is “UEFI recognizes an NVMe controller and reads the drive reliably.”.

D:

SATA remains a supported SSD interface independent of NVMe. For the situation described—An application wants an SSD that fits a PCIe M.2 slot but the purchased M.2 SATA module is not detected—this would not demonstrate the specified intervention. The relevant evidence is “UEFI recognizes an NVMe controller and reads the drive reliably.”.

Question 787

A two-drive mirror survives disk failure but an intern assumes it will restore a document deleted by mistake. What should the technician configure or repair to resolve this issue?

  1. Configure a properly supported RAID 6 set and independent backups.
  2. Recover from an independent backup rather than expecting RAID 0 to survive the lost disk.
  3. Configure RAID 6 using disks/controller that support dual parity.
  4. Maintain a separate versioned backup and restore the deleted file from it.

Explanation

Correct Answer

D:

RAID mirroring replicates logical deletions and does not replace versioned backups. In this situation—A two-drive mirror survives disk failure but an intern assumes it will restore a document deleted by mistake—the right response is “Maintain a separate versioned backup and restore the deleted file from it.”. A confirming result would be “The accidental deletion is reversed from a historical recovery point.”.

Incorrect Answers

A:

Dual-parity RAID 6 can tolerate two drive failures at the cost of capacity and write overhead. That does not directly address the condition described—A two-drive mirror survives disk failure but an intern assumes it will restore a document deleted by mistake. “Maintain a separate versioned backup and restore the deleted file from it.” is the appropriate response because rAID mirroring replicates logical deletions and does not replace versioned backups.

B:

RAID 0 stripes without parity or mirroring and has no single-disk fault tolerance. That does not directly address the condition described—A two-drive mirror survives disk failure but an intern assumes it will restore a document deleted by mistake. “Maintain a separate versioned backup and restore the deleted file from it.” is the appropriate response because rAID mirroring replicates logical deletions and does not replace versioned backups.

C:

RAID 6 uses dual distributed parity for two-disk failure tolerance. That does not directly address the condition described—A two-drive mirror survives disk failure but an intern assumes it will restore a document deleted by mistake. “Maintain a separate versioned backup and restore the deleted file from it.” is the appropriate response because rAID mirroring replicates logical deletions and does not replace versioned backups.

Question 788

A two-drive mirror survives disk failure but an intern assumes it will restore a document deleted by mistake. How should the technician verify the corrective change?

  1. Restored files pass integrity checks after the array is rebuilt.
  2. A controlled two-member failure simulation remains accessible.
  3. Restored data passes integrity tests on a rebuilt healthy array.
  4. The accidental deletion is reversed from a historical recovery point.

Explanation

Correct Answer

D:

RAID mirroring replicates logical deletions and does not replace versioned backups. The outcome “The accidental deletion is reversed from a historical recovery point.” verifies the action “Maintain a separate versioned backup and restore the deleted file from it.” for this situation: A two-drive mirror survives disk failure but an intern assumes it will restore a document deleted by mistake.

Incorrect Answers

A:

RAID 0 stripes without parity or mirroring and has no single-disk fault tolerance. For the situation described—A two-drive mirror survives disk failure but an intern assumes it will restore a document deleted by mistake—this would not demonstrate the specified intervention. The relevant evidence is “The accidental deletion is reversed from a historical recovery point.”.

B:

RAID 6 uses dual distributed parity for two-disk failure tolerance. For the situation described—A two-drive mirror survives disk failure but an intern assumes it will restore a document deleted by mistake—this would not demonstrate the specified intervention. The relevant evidence is “The accidental deletion is reversed from a historical recovery point.”.

C:

RAID 10 fault tolerance depends on which mirror members fail, not merely on total failed drive count. For the situation described—A two-drive mirror survives disk failure but an intern assumes it will restore a document deleted by mistake—this would not demonstrate the specified intervention. The relevant evidence is “The accidental deletion is reversed from a historical recovery point.”.

Question 789

An archive server values capacity and survives two concurrent disk failures with minimum required drives. Which intervention is best supported by the evidence?

  1. Configure RAID 6 using disks/controller that support dual parity.
  2. Configure a properly supported RAID 6 set and independent backups.
  3. Configure RAID 1 mirroring with a proper backup strategy.
  4. Configure RAID 10 with adequate member count and backups.

Explanation

Correct Answer

B:

Dual-parity RAID 6 can tolerate two drive failures at the cost of capacity and write overhead. In this situation—An archive server values capacity and survives two concurrent disk failures with minimum required drives—the right response is “Configure a properly supported RAID 6 set and independent backups.”. A confirming result would be “A controlled two-member fault leaves the array data available.”.

Incorrect Answers

A:

RAID 6 uses dual distributed parity for two-disk failure tolerance. That does not directly address the condition described—An archive server values capacity and survives two concurrent disk failures with minimum required drives. “Configure a properly supported RAID 6 set and independent backups.” is the appropriate response because dual-parity RAID 6 can tolerate two drive failures at the cost of capacity and write overhead.

C:

RAID 1 keeps a mirror copy on each member, though it is not backup. That does not directly address the condition described—An archive server values capacity and survives two concurrent disk failures with minimum required drives. “Configure a properly supported RAID 6 set and independent backups.” is the appropriate response because dual-parity RAID 6 can tolerate two drive failures at the cost of capacity and write overhead.

D:

RAID 10 stripes mirrored pairs, combining speed and redundancy. That does not directly address the condition described—An archive server values capacity and survives two concurrent disk failures with minimum required drives. “Configure a properly supported RAID 6 set and independent backups.” is the appropriate response because dual-parity RAID 6 can tolerate two drive failures at the cost of capacity and write overhead.

Question 790

An archive server values capacity and survives two concurrent disk failures with minimum required drives. Which test outcome demonstrates that the chosen action worked?

  1. Restored data passes integrity tests on a rebuilt healthy array.
  2. A controlled two-member failure simulation remains accessible.
  3. A controlled two-member fault leaves the array data available.
  4. Restored files pass integrity checks after the array is rebuilt.

Explanation

Correct Answer

C:

Dual-parity RAID 6 can tolerate two drive failures at the cost of capacity and write overhead. The outcome “A controlled two-member fault leaves the array data available.” verifies the action “Configure a properly supported RAID 6 set and independent backups.” for this situation: An archive server values capacity and survives two concurrent disk failures with minimum required drives.

Incorrect Answers

A:

RAID 10 fault tolerance depends on which mirror members fail, not merely on total failed drive count. For the situation described—An archive server values capacity and survives two concurrent disk failures with minimum required drives—this would not demonstrate the specified intervention. The relevant evidence is “A controlled two-member fault leaves the array data available.”.

B:

RAID 6 uses dual distributed parity for two-disk failure tolerance. For the situation described—An archive server values capacity and survives two concurrent disk failures with minimum required drives—this would not demonstrate the specified intervention. The relevant evidence is “A controlled two-member fault leaves the array data available.”.

D:

RAID 0 stripes without parity or mirroring and has no single-disk fault tolerance. For the situation described—An archive server values capacity and survives two concurrent disk failures with minimum required drives—this would not demonstrate the specified intervention. The relevant evidence is “A controlled two-member fault leaves the array data available.”.