Question 50
A change was made inside a SmartConsole session on the Active management member, but nobody published that session. The Standby does not reflect the proposed object, although peer synchronization is healthy. What behavior best explains why the Standby lacks the edit?
Explanation
Correct Answer
Management HA replicates published revisions; changes that remain private in an unpublished session are not synchronized to the standby database.
Incorrect Answers
General database synchronization does not include unpublished private session data.
Manually syncing an unchanged published revision cannot transfer unpublished edits.
Inspecting HA status can confirm peer health, but it cannot publish an administrator's still-private SmartConsole session.