McAfee-Secured Website

Exam Bundle

Exam Code: 2V0-17.25

Exam Name VMware Cloud Foundation 9.0 Administrator

Certification Provider: VMware

Corresponding Certification: VCP-VCF Administrator

VMware 2V0-17.25 Bundle $19.99

100% VMware 2V0-17.25 Guaranteed Success With Testking Training Materials

Get Real 2V0-17.25 Exam Questions & Expert Verified Answers as Experienced on the Real Exam!

  • Questions & Answers

    2V0-17.25 Questions & Answers

    100 Questions & Answers

    The ultimate exam preparation tool, Questions & Answers mirrors the actual 2V0-17.25 exam while allowing you to hone and measure every aspect of your test-taking ability.

  • Study Guide

    2V0-17.25 Study Guide

    121 PDF Pages

    Developed by industry experts, this 121-page guide spells out in painstaking detail all of the information you need to ace 2V0-17.25 exam.

VMware Cloud Foundation 9.0 Administrator (2V0-17.25) Practice Tests

Satisfaction Guaranteed

Money Back Guarantee

Testking provides hassle-free money back guarantee with our products. That is because we have 100% trust in the abilities of our professional and experience product team, and our record is a proof of that.

99.6% PASS RATE
Total Cost: $154.98
Bundle Price: $134.99

Purchase Individually

  • Questions & Answers

    Questions & Answers

    100 Questions

    $124.99
  • Study Guide

    Study Guide

    121 PDF Pages

    $29.99

VMware 2V0-17.25 Practice Test 4

Question 30

Scenario: A VCF management cluster is being prepared and installation checks show forward and reverse DNS inconsistency for vCenter. Which observation would demonstrate that the requirement is satisfied?

  1. The deployment wizard is bypassed, leaving registration errors during appliance startup
  2. Installation validation resolves appliance names to intended IPs and records consistent reverse mappings
  3. Only one administrator laptop resolves the intended hostname through a local hosts file
  4. The vCenter IP pings but a reverse query returns a different host name

Explanation

Correct Answer

B:

This directly verifies dependable management DNS before components are installed.

Incorrect Answers

A:

Skipping a precheck does not satisfy the required name-service foundation.

C:

A client-specific workaround does not establish shared authoritative DNS correctness.

D:

Network reachability does not resolve the identity mismatch.

Question 31

Scenario: A team replaces an ESX host with new hardware and needs it to join the correct vCenter cluster without drifting its network configuration. What is the most defensible next step for the VCF administrator?

  1. Join the host to whichever vCenter responds first without checking administrative scope
  2. Apply the validated host profile or desired configuration and join the intended cluster through vCenter
  3. Copy random switch mappings from a different workload domain
  4. Disable host network settings after vCenter enrollment to avoid configuration warnings

Explanation

Correct Answer

B:

A consistent baseline helps replacement hosts match approved networking and security settings.

Incorrect Answers

A:

Arbitrary registration can place the host under the wrong workload domain.

C:

Another domain may use incompatible uplink assignments and VLANs.

D:

Removing intended settings prevents consistent host operation rather than fixing drift.

Question 32

Scenario: A team replaces an ESX host with new hardware and needs it to join the correct vCenter cluster without drifting its network configuration. During acceptance testing, what result should the team require?

  1. The host appears in inventory under a different workload domain
  2. A desired-state check reports critical network drift but is ignored after a successful ping
  3. The replacement host passes compliance and connectivity checks for its assigned cluster
  4. The replacement has a matching host name but incompatible physical uplink mapping

Explanation

Correct Answer

C:

A validated baseline and correct inventory prove that the replacement fits the domain.

Incorrect Answers

A:

Inventory presence under the wrong management scope fails the placement requirement.

B:

Ping reachability does not substitute for approved baseline compliance.

D:

Names alone cannot validate necessary host network configuration.

Question 33

Scenario: A new host has more physical network adapters than its predecessor and a VCF administrator must map management and workload traffic safely. Which configuration change best resolves this problem?

  1. Assume adapter numbering is identical across different server models
  2. Map host physical uplinks to the designed vSphere networking and verify management continuity
  3. Delete the host management vmkernel adapter before confirming a replacement path
  4. Assign all physical adapters to an unverified workload port group

Explanation

Correct Answer

B:

Correct vmnic-to-uplink relationships prevent accidental loss of management connectivity.

Incorrect Answers

A:

Hardware discovery order can differ and invalidate copied uplink assignments.

C:

Removing the only working management interface can disconnect the ESX host.

D:

Unplanned mapping can strand vmkernel management traffic after migration.

Question 34

Scenario: A new host has more physical network adapters than its predecessor and a VCF administrator must map management and workload traffic safely. What evidence distinguishes a successful change from a misleading green status?

  1. Host management remains reachable while workload VLAN and failover tests pass
  2. A failed physical uplink disconnects all host management traffic despite spare adapters
  3. A virtual machine can ping another VM but the host cannot be managed remotely
  4. The port group names match a checklist but connect to incorrect physical VLANs

Explanation

Correct Answer

A:

This demonstrates the intended mapping supports both control and data paths.

Incorrect Answers

B:

Unvalidated failover defeats the intended network resilience.

C:

Guest reachability does not establish management continuity.

D:

Names alone are not evidence of correct NIC-to-fabric assignments.

Question 35

Scenario: During new VCF compute bring-up, ESX hosts report different time sources and management certificate checks intermittently fail. How should the platform team proceed?

  1. Suppress all certificate validity alerts while leaving time drift unresolved
  2. Set each host clock manually once without a maintained time source
  3. Configure consistent reachable NTP sources and confirm clock synchronization across management components
  4. Change VM CPU reservations in an attempt to repair certificate date mismatches

Explanation

Correct Answer

C:

Time consistency supports certificates, authentication and correlated operational telemetry.

Incorrect Answers

A:

Ignoring certificate symptoms does not restore dependable clock-based security checks.

B:

Manual adjustment does not prevent future drift across the management fleet.

D:

Compute resource allocation is not the cause of inconsistent wall clocks.

Question 36

Scenario: During new VCF compute bring-up, ESX hosts report different time sources and management certificate checks intermittently fail. Which measured outcome would verify the intended behavior?

  1. Management hosts and appliances agree on time and complete authenticated service registration
  2. CPU ready time is low but service tokens still report invalid time windows
  3. An ESX host shows the current date while vCenter remains minutes out of sync
  4. Certificates are accepted only after bypassing time-validity enforcement

Explanation

Correct Answer

A:

This directly tests the clock foundation needed for reliable management services.

Incorrect Answers

B:

Performance metrics cannot establish correct identity-service clock behavior.

C:

One correct host cannot prove clock alignment across services.

D:

Bypass does not correct the underlying time-sync and trust failure.

Question 37

Scenario: A VCF compute cluster must restart critical VMs on surviving hosts after a single ESX server fails. Which implementation choice fits these constraints?

  1. Enable and size vSphere HA with sufficient failover capacity and compatible shared storage
  2. Pin every critical VM to the same physical host with strict affinity rules
  3. Enable DRS alone and assume it restarts powered-off VMs after host loss
  4. Increase datastore snapshots without configuring cluster availability

Explanation

Correct Answer

A:

HA requires available hosts and resources able to restart affected virtual machines.

Incorrect Answers

B:

Concentrated placement makes a single hardware outage more disruptive.

C:

DRS optimizes placement but is not a replacement for HA restart decisions.

D:

Snapshots cannot independently restart powered-on workloads after a failed host.

Question 38

Scenario: A VCF compute cluster must restart critical VMs on surviving hosts after a single ESX server fails. Which result should block sign-off until it is achieved?

  1. A host-failure exercise restarts protected VMs on surviving capacity within the objective
  2. VM snapshots exist but all VMs stay unavailable after an ESX outage
  3. DRS moves a running VM during a manual maintenance task while HA remains disabled
  4. The cluster reports green health but no failover capacity remains for a lost host

Explanation

Correct Answer

A:

It demonstrates the availability action works under the expected failure.

Incorrect Answers

B:

Backup points are not automatic high-availability restart behavior.

C:

A planned migration does not test unplanned host-loss recovery.

D:

Normal health alone does not prove survivable restart capacity.

Question 39

Scenario: A mixed virtual machine cluster has severe resource imbalance after several VMs were manually pinned to individual ESX hosts. Which administrative action best meets the stated requirement?

  1. Increase vSAN policy failures to tolerate to rebalance CPU load
  2. Delete the management vCenter VM to reset resource scheduling state
  3. Disable all DRS recommendations and leave pinned VMs on saturated hosts
  4. Review DRS settings and VM/host rules to enable appropriate balanced placement

Explanation

Correct Answer

D:

Placement restrictions can override automated balancing even when compute capacity exists.

Incorrect Answers

A:

Storage protection policy is unrelated to CPU scheduling balance.

B:

Removing management infrastructure does not correct inappropriate affinity rules.

C:

Manual restriction preserves the imbalance that the administrator is meant to fix.

Question 40

Scenario: A mixed virtual machine cluster has severe resource imbalance after several VMs were manually pinned to individual ESX hosts. Which observation would demonstrate that the requirement is satisfied?

  1. The cluster has identical host models yet VMs cannot migrate due to prohibited rule combinations
  2. CPU contention falls after compatible workload moves and cluster rule checks remain satisfied
  3. Storage consumption drops but CPU ready remains high for the pinned VMs
  4. The DRS service is enabled but strict pinning leaves one host heavily overloaded

Explanation

Correct Answer

B:

Observed balance and policy compliance establish the placement change was effective.

Incorrect Answers

A:

Hardware uniformity does not eliminate a broken DRS rule design.

C:

Storage savings do not demonstrate CPU scheduling recovery.

D:

A toggle does not defeat incompatible VM placement restrictions.