McAfee-Secured Website

Exam Bundle

Exam Code: 2V0-17.25

Exam Name VMware Cloud Foundation 9.0 Administrator

Certification Provider: VMware

Corresponding Certification: VCP-VCF Administrator

VMware 2V0-17.25 Bundle $19.99

100% VMware 2V0-17.25 Guaranteed Success With Testking Training Materials

Get Real 2V0-17.25 Exam Questions & Expert Verified Answers as Experienced on the Real Exam!

  • Questions & Answers

    2V0-17.25 Questions & Answers

    100 Questions & Answers

    The ultimate exam preparation tool, Questions & Answers mirrors the actual 2V0-17.25 exam while allowing you to hone and measure every aspect of your test-taking ability.

  • Study Guide

    2V0-17.25 Study Guide

    121 PDF Pages

    Developed by industry experts, this 121-page guide spells out in painstaking detail all of the information you need to ace 2V0-17.25 exam.

VMware Cloud Foundation 9.0 Administrator (2V0-17.25) Practice Tests

Satisfaction Guaranteed

Money Back Guarantee

Testking provides hassle-free money back guarantee with our products. That is because we have 100% trust in the abilities of our professional and experience product team, and our record is a proof of that.

99.6% PASS RATE
Total Cost: $154.98
Bundle Price: $134.99

Purchase Individually

  • Questions & Answers

    Questions & Answers

    100 Questions

    $124.99
  • Study Guide

    Study Guide

    121 PDF Pages

    $29.99

VMware 2V0-17.25 Practice Test 24

Question 230

Scenario: An expanding VCF tenant service requires more host capacity in one workload domain without moving its VMs into another domain. Which observation would demonstrate that the requirement is satisfied?

  1. New servers show in inventory but cannot join the designated domain because of version mismatch
  2. Applications are moved to management hosts while the target domain remains saturated
  3. Host count rises but tenant VM migrations fail due to missing NSX or storage connections
  4. The intended domain gains usable host capacity and existing workloads remain reachable

Explanation

Correct Answer

D:

That verifies an in-place expansion with functioning platform services.

Incorrect Answers

A:

Inventory presence does not mean compatible available compute.

B:

Relocation to the wrong scope does not satisfy the requested expansion.

C:

Capacity numbers alone do not prove usable domain expansion.

Question 231

Scenario: A development workload domain should be isolated from production while sharing VCF fleet operations and central identity. What is the most defensible next step for the VCF administrator?

  1. Configure separate domain capacity and tenant access boundaries with centralized monitoring integration
  2. Build development on an untracked standalone hypervisor fleet outside VCF
  3. Give development users access to all production vCenter objects to simplify identity mapping
  4. Remove central monitoring for development to avoid shared management visibility

Explanation

Correct Answer

A:

Separate workload scope can coexist with unified governance and telemetry.

Incorrect Answers

B:

An unmanaged island does not retain the required central operations model.

C:

Shared authentication does not justify unrestricted crossdomain authorization.

D:

Loss of telemetry undermines the requested unified operational oversight.

Question 232

Scenario: A development workload domain should be isolated from production while sharing VCF fleet operations and central identity. During acceptance testing, what result should the team require?

  1. Development has separate hosts but no registration in VCF Operations
  2. Development teams deploy within their assigned scope and fleet admins see both domains appropriately
  3. Both domains appear in a dashboard while developers can traverse unrestricted production networks
  4. Developers can change production VM hardware because they share the identity source

Explanation

Correct Answer

B:

This verifies isolation and shared operations simultaneously.

Incorrect Answers

A:

Physical separation alone does not meet shared fleet visibility requirements.

C:

Monitoring integration does not excuse missing network isolation.

D:

Common sign-on must still enforce distinct roles and scopes.

Question 233

Scenario: A newly created VCF workload domain will host transactional applications requiring policy-based protection on its vSAN datastore. Which configuration change best resolves this problem?

  1. Configure supported vSAN storage policies for the domain and validate application placement
  2. Mount an unrelated local datastore on one host and assume the domain shares it
  3. Increase CPU socket counts to make vSAN virtual disks more fault tolerant
  4. Assign every VM an arbitrary default policy without checking its resilience target

Explanation

Correct Answer

A:

Storage policies express failure tolerance and capacity requirements at the workload object level.

Incorrect Answers

B:

Host-local disk access does not supply managed distributed storage to the cluster.

C:

Compute allocation does not define distributed storage protection.

D:

An unchecked default may not satisfy domain-specific availability requirements.

Question 234

Scenario: A newly created VCF workload domain will host transactional applications requiring policy-based protection on its vSAN datastore. What evidence distinguishes a successful change from a misleading green status?

  1. The workload domain exists but every critical VMDK reports noncompliance
  2. One VM powers on with local-only storage while planned mobility between hosts fails
  3. Domain VMDKs show compliant storage policies and pass a host-failure access test
  4. The storage policy is documented but never applied to application objects

Explanation

Correct Answer

C:

It demonstrates policy enforcement and real data availability for the workload.

Incorrect Answers

A:

Successful domain creation is not sufficient for storage readiness.

B:

A single running guest does not prove shared-domain storage support.

D:

Declared intent is not enforced storage configuration.

Question 235

Scenario: A VCF VI workload domain will use supported external NFS storage instead of the local vSAN datastore for one application tier. How should the platform team proceed?

  1. Mount the approved shared NFS datastore on the intended ESX hosts and validate access
  2. Attach the NFS export to only one host while the domain requires mobility across the cluster
  3. Use a private guest SMB share as the hypervisor's NFS mount path
  4. Assume vSAN must be configured for every application VMDK regardless of approved external support

Explanation

Correct Answer

A:

External datastore use requires consistent transport, exports and authorized access.

Incorrect Answers

B:

Host-limited mount prevents other hosts from accessing the same VM files.

C:

Guest file services are not identical to ESX NFS datastore protocol.

D:

Unnecessary replacement conflicts with the supported external-storage requirement.

Question 236

Scenario: A VCF VI workload domain will use supported external NFS storage instead of the local vSAN datastore for one application tier. Which measured outcome would verify the intended behavior?

  1. The VM can read guest SMB content while its VMDK remains on unrelated local disks
  2. The NFS hostname resolves but actual file operations are denied
  3. One server mounts the share but other cluster nodes receive export permission errors
  4. All intended hosts can use the datastore and supported migration operations succeed

Explanation

Correct Answer

D:

This verifies a functional external storage path under the managed domain.

Incorrect Answers

A:

Guest file availability does not validate the requested hypervisor datastore.

B:

DNS alone does not establish storage export access.

C:

A source-only mount is insufficient for shared workload mobility.

Question 237

Scenario: An architect wants a workload domain's data disks protected against host failure while reserving less capacity than a more redundant management tier. Which implementation choice fits these constraints?

  1. Drop every critical object to FTT=0 just to free storage space
  2. Choose an erasure coding layout without validating host and fault-domain prerequisites
  3. Copy the management domain policy to every data disk without understanding its reservation and protection settings
  4. Define distinct domain or VM storage policies aligned to actual RPO and FTT needs

Explanation

Correct Answer

D:

Different workload criticality can justify different supported placement and capacity choices.

Incorrect Answers

A:

Removing minimum required resilience violates the stated data-availability requirement.

B:

Unsupported placement cannot satisfy its declared policy even when capacity appears free.

C:

A blanket policy may create unnecessary capacity pressure or incorrect behavior.

Question 238

Scenario: An architect wants a workload domain's data disks protected against host failure while reserving less capacity than a more redundant management tier. Which result should block sign-off until it is achieved?

  1. Management disks become unreserved and critical control-plane operations fail under full capacity
  2. An object policy displays the intended name but reports insufficient placement resources
  3. The application disks meet required FTT and capacity objectives in a host-failure test
  4. Storage overhead declines only because previously protected disks lose all redundancy

Explanation

Correct Answer

C:

Both actual resilience and physical overhead should match the chosen policy.

Incorrect Answers

A:

Workload efficiency cannot be gained by risking management availability.

B:

A named policy does not guarantee implementable protection.

D:

Unprotected objects cannot be accepted as compliant cost optimization.

Question 239

Scenario: After a VCF workload domain expands, storage compliance alarms appear because new ESX nodes cannot access the configured shared datastore. Which administrative action best meets the stated requirement?

  1. Move application VMs to inaccessible hosts and assume vSphere HA will correct storage visibility
  2. Check datastore presentation and path configuration for every added host before distributing workloads
  3. Ignore missing storage paths because the management domain is healthy
  4. Disable policy compliance alerts rather than restoring host storage connectivity

Explanation

Correct Answer

B:

New hosts must have the same required backing access as the existing cluster.

Incorrect Answers

A:

HA cannot power on a VM whose required disks cannot be opened.

C:

Health in a different domain cannot repair this domain's datastore access.

D:

Alert suppression hides the underlying placement failure.

Question 240

Scenario: After a VCF workload domain expands, storage compliance alarms appear because new ESX nodes cannot access the configured shared datastore. Which observation would demonstrate that the requirement is satisfied?

  1. The new host is in vCenter inventory but reports the target datastore as inaccessible
  2. A dashboard is green only after storage compliance alarms have been disabled
  3. Every added host accesses the approved datastore and VM storage policies return to compliance
  4. The VM migrates compute but fails to read its VMDK at destination

Explanation

Correct Answer

C:

This demonstrates real usable storage expansion rather than inventory-only growth.

Incorrect Answers

A:

Inventory membership alone does not establish working storage paths.

B:

A muted alert is not actual restoration of storage functionality.

D:

Migration success cannot excuse missing shared datastore access.