Question 40
An architecture decision record at a scientific institute must resolve the following risk for instrument processing: A vSAN design meets nominal throughput but all storage traffic is placed on a congested shared uplink. What is the appropriate design action?
Explanation
Correct Answer
The most direct design decision is to provide suitable physical bandwidth and isolation for storage traffic as required. For instrument processing at a scientific institute, the stated problem is: A vSAN design meets nominal throughput but all storage traffic is placed on a congested shared uplink. That approach addresses the documented architecture objective rather than an unrelated implementation detail. It should be accepted when modeled rebuild and peak workloads remain within the designed network budget. The design choice remains subject to the real environment's compatibility and constraints.
Incorrect Answers
Map physical hosts storage network and supported hardware to each domain addresses the separate architecture topic of physical workload domain design, where the underlying concern is: An approved workload domain count cannot be built with the hardware assigned to the site. It does not most directly resolve the present issue for instrument processing at a scientific institute: A vSAN design meets nominal throughput but all storage traffic is placed on a congested shared uplink. The targeted decision is instead to provide suitable physical bandwidth and isolation for storage traffic as required.
Size physical storage for policy overhead failures rebuilds and growth addresses the separate architecture topic of physical storage capacity, where the underlying concern is: A vSAN design matches raw disk totals to guest usage without accounting for protection and free space. It does not most directly resolve the present issue for instrument processing at a scientific institute: A vSAN design meets nominal throughput but all storage traffic is placed on a congested shared uplink. The targeted decision is instead to provide suitable physical bandwidth and isolation for storage traffic as required.
Include required automation services in the physical resource and dependency plan addresses the separate architecture topic of physical automation components, where the underlying concern is: The automation service is in the conceptual plan but appliance placement and resource reservations are omitted. It does not most directly resolve the present issue for instrument processing at a scientific institute: A vSAN design meets nominal throughput but all storage traffic is placed on a congested shared uplink. The targeted decision is instead to provide suitable physical bandwidth and isolation for storage traffic as required.