Question 470
An architecture decision record at a retail financial platform must resolve the following risk for consumer credit services: Two logical availability zones use the same upstream power distribution and carrier paths. What is the appropriate design action?
Explanation
Correct Answer
The most direct design decision is to validate independence of power networking and facilities for designated fault domains. For consumer credit services at a retail financial platform, the stated problem is: Two logical availability zones use the same upstream power distribution and carrier paths. That approach addresses the documented architecture objective rather than an unrelated implementation detail. It should be accepted when the design's dependency map shows separation for the tested outage classes. The design choice remains subject to the real environment's compatibility and constraints.
Incorrect Answers
Plan compatible staged updates and service placement around the permitted maintenance window addresses the separate architecture topic of maintenance windows and uptime, where the underlying concern is: A planned lifecycle update will stop every service at once despite a strict availability SLO. It does not most directly resolve the present issue for consumer credit services at a retail financial platform: Two logical availability zones use the same upstream power distribution and carrier paths. The targeted decision is instead to validate independence of power networking and facilities for designated fault domains.
Clarify achievable interruption targets and choose availability mechanisms accordingly addresses the separate architecture topic of availability target realism, where the underlying concern is: A stakeholder requests zero service interruption but budget and topology permit only restart-based recovery. It does not most directly resolve the present issue for consumer credit services at a retail financial platform: Two logical availability zones use the same upstream power distribution and carrier paths. The targeted decision is instead to validate independence of power networking and facilities for designated fault domains.
Design supported placement and service redundancy across the defined availability zones addresses the separate architecture topic of availability zones, where the underlying concern is: A service requires resilience against a whole-zone outage but every cluster component shares one fault zone. It does not most directly resolve the present issue for consumer credit services at a retail financial platform: Two logical availability zones use the same upstream power distribution and carrier paths. The targeted decision is instead to validate independence of power networking and facilities for designated fault domains.