Question 230
After approving a design correction for research computing services at a major university, reviewers revisit: The design's surviving hosts cannot meet memory demand after one failure and service restarts thrash. Which observation confirms that the intended objective was met?
Explanation
Correct Answer
The strongest outcome is that reduced-cluster performance remains acceptable at agreed representative load. That finding directly checks the reported design issue in research computing services at a major university: The design's surviving hosts cannot meet memory demand after one failure and service restarts thrash. It tests the intended response, namely to include N+1 or other appropriate failure headroom when assessing cluster capacity, rather than mistaking an architecture diagram or configuration change alone for validated business behavior.
Incorrect Answers
Change simulations show the service remains within agreed uptime commitments addresses the separate architecture topic of maintenance windows and uptime, where the underlying concern is: A planned lifecycle update will stop every service at once despite a strict availability SLO. It does not most directly resolve the present issue for research computing services at a major university: The design's surviving hosts cannot meet memory demand after one failure and service restarts thrash. The targeted validation evidence is instead to reduced-cluster performance remains acceptable at agreed representative load.
Service resolution remains available during the designated single-failure event addresses the separate architecture topic of resilient external services, where the underlying concern is: Every redundant workload depends on one DNS endpoint that fails with a rack. It does not most directly resolve the present issue for research computing services at a major university: The design's surviving hosts cannot meet memory demand after one failure and service restarts thrash. The targeted validation evidence is instead to reduced-cluster performance remains acceptable at agreed representative load.
A host outage test meets agreed interruption and remaining-resource limits addresses the separate architecture topic of single-host failure, where the underlying concern is: A critical application must survive one ESX host failure but cluster resources are sized only for normal operation. It does not most directly resolve the present issue for research computing services at a major university: The design's surviving hosts cannot meet memory demand after one failure and service restarts thrash. The targeted validation evidence is instead to reduced-cluster performance remains acceptable at agreed representative load.