Question 190
While planning a VCF platform for donor services at a humanitarian organization, stakeholders discover: A vSAN design matches raw disk totals to guest usage without accounting for protection and free space. Which decision is most defensible?
Explanation
Correct Answer
The most direct design decision is to size physical storage for policy overhead failures rebuilds and growth. For donor services at a humanitarian organization, the stated problem is: A vSAN design matches raw disk totals to guest usage without accounting for protection and free space. That approach addresses the documented architecture objective rather than an unrelated implementation detail. It should be accepted when the usable capacity projection remains within required free-space and resilience limits. The design choice remains subject to the real environment's compatibility and constraints.
Incorrect Answers
Map physical hosts storage network and supported hardware to each domain addresses the separate architecture topic of physical workload domain design, where the underlying concern is: An approved workload domain count cannot be built with the hardware assigned to the site. It does not most directly resolve the present issue for donor services at a humanitarian organization: A vSAN design matches raw disk totals to guest usage without accounting for protection and free space. The targeted decision is instead to size physical storage for policy overhead failures rebuilds and growth.
Provide suitable physical bandwidth and isolation for storage traffic as required addresses the separate architecture topic of physical storage networks, where the underlying concern is: A vSAN design meets nominal throughput but all storage traffic is placed on a congested shared uplink. It does not most directly resolve the present issue for donor services at a humanitarian organization: A vSAN design matches raw disk totals to guest usage without accounting for protection and free space. The targeted decision is instead to size physical storage for policy overhead failures rebuilds and growth.
Document network and storage wiring with interface addresses and physical port identifiers addresses the separate architecture topic of rack cabling traceability, where the underlying concern is: The physical design lists host counts but cable labels and upstream port connections are undefined. It does not most directly resolve the present issue for donor services at a humanitarian organization: A vSAN design matches raw disk totals to guest usage without accounting for protection and free space. The targeted decision is instead to size physical storage for policy overhead failures rebuilds and growth.