Question 110
After approving a design correction for content delivery systems at a higher-education publisher, reviewers revisit: A vSAN design matches raw disk totals to guest usage without accounting for protection and free space. Which observation confirms that the intended objective was met?
Explanation
Correct Answer
The strongest outcome is that the usable capacity projection remains within required free-space and resilience limits. That finding directly checks the reported design issue in content delivery systems at a higher-education publisher: A vSAN design matches raw disk totals to guest usage without accounting for protection and free space. It tests the intended response, namely to size physical storage for policy overhead failures rebuilds and growth, rather than mistaking an architecture diagram or configuration change alone for validated business behavior.
Incorrect Answers
The capacity plan shows adequate management overhead after expected failure addresses the separate architecture topic of physical management sizing, where the underlying concern is: The management domain BOM omits resource needs for several required VCF management appliances. It does not most directly resolve the present issue for content delivery systems at a higher-education publisher: A vSAN design matches raw disk totals to guest usage without accounting for protection and free space. The targeted validation evidence is instead to the usable capacity projection remains within required free-space and resilience limits.
Capacity modeling verifies workload demand on the reduced surviving host set addresses the separate architecture topic of capacity for failover, where the underlying concern is: A four-node cluster meets average load only when every host is healthy. It does not most directly resolve the present issue for content delivery systems at a higher-education publisher: A vSAN design matches raw disk totals to guest usage without accounting for protection and free space. The targeted validation evidence is instead to the usable capacity projection remains within required free-space and resilience limits.
Failure analysis shows no undocumented common switch for the required paths addresses the separate architecture topic of physical routing redundancy, where the underlying concern is: The logical plan uses diverse paths but both physical uplinks terminate on the same failed-capable switch. It does not most directly resolve the present issue for content delivery systems at a higher-education publisher: A vSAN design matches raw disk totals to guest usage without accounting for protection and free space. The targeted validation evidence is instead to the usable capacity projection remains within required free-space and resilience limits.