Question 20
For Willowbrook Education, a proposed storage change affects student registration databases and departmental files. The identified control failure is: A hardware replacement plan removes a failed disk without checking automatic reconstruction progress or matching spare availability. The team reports that the correction is complete. Which observation BEST proves the stated problem is resolved?
Explanation
Correct Answer
The new drive is recognized and the RAID group reconstruction completes without unresolved disk faults. The observation verifies that the chosen action (Confirm degraded RAID group status and compatible spare capacity before following the documented drive replacement workflow) has corrected the initiating failure (A hardware replacement plan removes a failed disk without checking automatic reconstruction progress or matching spare availability). This is directly measurable for Willowbrook Education's student registration databases and departmental files rather than merely reporting task completion.
Incorrect Answers
The planned host-facing capacity reconciles with the configured local-tier usable space after overhead. This is a valid test for another condition (A capacity calculation treats raw SSD labels as completely usable space and omits RAID, system reserves and spare overhead) after a different correction (Size aggregate or local-tier usable storage using platform-specific RAID and reserve requirements). It does not establish the necessary result for Willowbrook Education's student registration databases and departmental files: The new drive is recognized and the RAID group reconstruction completes without unresolved disk faults.
Every required host, cluster, management and shelf connection maps to an available supported port. This is a valid test for another condition (A proposed controller pair has inadequate supported ports for required host protocol and back-end shelf connectivity) after a different correction (Validate adapter and port availability and approved configurations in the Hardware Universe design). It does not establish the necessary result for Willowbrook Education's student registration databases and departmental files: The new drive is recognized and the RAID group reconstruction completes without unresolved disk faults.
The recorded platform bill of materials is supported for the intended ONTAP version and media type. This is a valid test for another condition (A proposed ONTAP controller has no verified disk shelf compatibility for its target release and storage media) after a different correction (Consult NetApp Hardware Universe and interoperability guidance before approving the controller and shelf combination). It does not establish the necessary result for Willowbrook Education's student registration databases and departmental files: The new drive is recognized and the RAID group reconstruction completes without unresolved disk faults.