McAfee-Secured Website

Exam Code: NS0-165

Exam Name: NetApp Certified Data Administrator, ONTAP

Certification Provider: Network Appliance

Corresponding Certification: NCDA ONTAP

100% Network Appliance NS0-165 Guaranteed Success With Testking Training Materials

Get Real NS0-165 Exam Questions & Expert Verified Answers as Experienced on the Real Exam!

60 Questions & Answers with Testing Engine

"NetApp Certified Data Administrator, ONTAP Exam", also known as NS0-165 exam, is a Network Appliance certification exam.

Pass your tests with the always up-to-date NS0-165 Exam Engine. Your NS0-165 training materials keep you at the head of the pack!

Satisfaction Guaranteed

Money Back Guarantee

Testking provides hassle-free money back guarantee with our products. That is because we have 100% trust in the abilities of our professional and experience product team, and our record is a proof of that.

99.6% PASS RATE
Was: $137.49
Now: $124.99

Network Appliance NS0-165 Practice Test 2

Question 10

Northshore Hospitality manages guest operations data and reservation reports under a documented recovery-time objective. A storage incident report states: A dual-controller deployment has unverified HA interconnect cabling and reports takeover readiness as unknown. The team reports that the correction is complete. Which observation BEST proves the stated problem is resolved?

  1. A planned loss of one shelf connection preserves storage availability and reports the failed path.
  2. ONTAP reports healthy HA partner communication and a supervised takeover readiness check completes.
  3. The recorded platform bill of materials is supported for the intended ONTAP version and media type.
  4. Every required host, cluster, management and shelf connection maps to an available supported port.

Explanation

Correct Answer

B:

ONTAP reports healthy HA partner communication and a supervised takeover readiness check completes. The observation verifies that the chosen action (Validate the required HA interconnect wiring and peer health before exposing production workloads) has corrected the initiating failure (A dual-controller deployment has unverified HA interconnect cabling and reports takeover readiness as unknown). This is directly measurable for Northshore Hospitality's guest operations data and reservation reports rather than merely reporting task completion.

Incorrect Answers

A:

A planned loss of one shelf connection preserves storage availability and reports the failed path. This is a valid test for another condition (A new controller installation relies on a single shelf path and an accidental cable pull isolates disks) after a different correction (Configure the recommended redundant SAS or supported storage shelf paths for that platform). It does not establish the necessary result for Northshore Hospitality's guest operations data and reservation reports: ONTAP reports healthy HA partner communication and a supervised takeover readiness check completes.

C:

The recorded platform bill of materials is supported for the intended ONTAP version and media type. This is a valid test for another condition (A proposed ONTAP controller has no verified disk shelf compatibility for its target release and storage media) after a different correction (Consult NetApp Hardware Universe and interoperability guidance before approving the controller and shelf combination). It does not establish the necessary result for Northshore Hospitality's guest operations data and reservation reports: ONTAP reports healthy HA partner communication and a supervised takeover readiness check completes.

D:

Every required host, cluster, management and shelf connection maps to an available supported port. This is a valid test for another condition (A proposed controller pair has inadequate supported ports for required host protocol and back-end shelf connectivity) after a different correction (Validate adapter and port availability and approved configurations in the Hardware Universe design). It does not establish the necessary result for Northshore Hospitality's guest operations data and reservation reports: ONTAP reports healthy HA partner communication and a supervised takeover readiness check completes.

Question 11

For Greenpeak Civic Services, a proposed storage change affects citizen forms and analytics staging shares. The identified control failure is: A dual-controller deployment has unverified HA interconnect cabling and reports takeover readiness as unknown. Which administrative action BEST addresses the specific problem?

  1. Configure the recommended redundant SAS or supported storage shelf paths for that platform.
  2. Validate adapter and port availability and approved configurations in the Hardware Universe design.
  3. Consult NetApp Hardware Universe and interoperability guidance before approving the controller and shelf combination.
  4. Validate the required HA interconnect wiring and peer health before exposing production workloads.

Explanation

Correct Answer

D:

Validate the required HA interconnect wiring and peer health before exposing production workloads. This action addresses the specific failure: A dual-controller deployment has unverified HA interconnect cabling and reports takeover readiness as unknown. For Greenpeak Civic Services's citizen forms and analytics staging shares, a successful implementation should produce the following evidence: ONTAP reports healthy HA partner communication and a supervised takeover readiness check completes.

Incorrect Answers

A:

Configure the recommended redundant SAS or supported storage shelf paths for that platform. That approach targets a different ONTAP condition: A new controller installation relies on a single shelf path and an accidental cable pull isolates disks. At Greenpeak Civic Services, for citizen forms and analytics staging shares, the actual failure is: A dual-controller deployment has unverified HA interconnect cabling and reports takeover readiness as unknown. That alternative by itself would not prove the needed outcome: ONTAP reports healthy HA partner communication and a supervised takeover readiness check completes.

B:

Validate adapter and port availability and approved configurations in the Hardware Universe design. That approach targets a different ONTAP condition: A proposed controller pair has inadequate supported ports for required host protocol and back-end shelf connectivity. At Greenpeak Civic Services, for citizen forms and analytics staging shares, the actual failure is: A dual-controller deployment has unverified HA interconnect cabling and reports takeover readiness as unknown. That alternative by itself would not prove the needed outcome: ONTAP reports healthy HA partner communication and a supervised takeover readiness check completes.

C:

Consult NetApp Hardware Universe and interoperability guidance before approving the controller and shelf combination. That approach targets a different ONTAP condition: A proposed ONTAP controller has no verified disk shelf compatibility for its target release and storage media. At Greenpeak Civic Services, for citizen forms and analytics staging shares, the actual failure is: A dual-controller deployment has unverified HA interconnect cabling and reports takeover readiness as unknown. That alternative by itself would not prove the needed outcome: ONTAP reports healthy HA partner communication and a supervised takeover readiness check completes.

Question 12

For Greenpeak Civic Services, a proposed storage change affects citizen forms and analytics staging shares. The identified control failure is: A dual-controller deployment has unverified HA interconnect cabling and reports takeover readiness as unknown. The team reports that the correction is complete. Which observation BEST proves the stated problem is resolved?

  1. A planned loss of one shelf connection preserves storage availability and reports the failed path.
  2. ONTAP reports healthy HA partner communication and a supervised takeover readiness check completes.
  3. Every required host, cluster, management and shelf connection maps to an available supported port.
  4. The recorded platform bill of materials is supported for the intended ONTAP version and media type.

Explanation

Correct Answer

B:

ONTAP reports healthy HA partner communication and a supervised takeover readiness check completes. The observation verifies that the chosen action (Validate the required HA interconnect wiring and peer health before exposing production workloads) has corrected the initiating failure (A dual-controller deployment has unverified HA interconnect cabling and reports takeover readiness as unknown). This is directly measurable for Greenpeak Civic Services's citizen forms and analytics staging shares rather than merely reporting task completion.

Incorrect Answers

A:

A planned loss of one shelf connection preserves storage availability and reports the failed path. This is a valid test for another condition (A new controller installation relies on a single shelf path and an accidental cable pull isolates disks) after a different correction (Configure the recommended redundant SAS or supported storage shelf paths for that platform). It does not establish the necessary result for Greenpeak Civic Services's citizen forms and analytics staging shares: ONTAP reports healthy HA partner communication and a supervised takeover readiness check completes.

C:

Every required host, cluster, management and shelf connection maps to an available supported port. This is a valid test for another condition (A proposed controller pair has inadequate supported ports for required host protocol and back-end shelf connectivity) after a different correction (Validate adapter and port availability and approved configurations in the Hardware Universe design). It does not establish the necessary result for Greenpeak Civic Services's citizen forms and analytics staging shares: ONTAP reports healthy HA partner communication and a supervised takeover readiness check completes.

D:

The recorded platform bill of materials is supported for the intended ONTAP version and media type. This is a valid test for another condition (A proposed ONTAP controller has no verified disk shelf compatibility for its target release and storage media) after a different correction (Consult NetApp Hardware Universe and interoperability guidance before approving the controller and shelf combination). It does not establish the necessary result for Greenpeak Civic Services's citizen forms and analytics staging shares: ONTAP reports healthy HA partner communication and a supervised takeover readiness check completes.

Question 13

At Boreal Foods, the production environment supports production inventory files and reporting LUNs with separately managed development and production resources. Investigators find: A new controller installation relies on a single shelf path and an accidental cable pull isolates disks. Which administrative action BEST addresses the specific problem?

  1. Validate adapter and port availability and approved configurations in the Hardware Universe design.
  2. Consult NetApp Hardware Universe and interoperability guidance before approving the controller and shelf combination.
  3. Configure the recommended redundant SAS or supported storage shelf paths for that platform.
  4. Validate the required HA interconnect wiring and peer health before exposing production workloads.

Explanation

Correct Answer

C:

Configure the recommended redundant SAS or supported storage shelf paths for that platform. This action addresses the specific failure: A new controller installation relies on a single shelf path and an accidental cable pull isolates disks. For Boreal Foods's production inventory files and reporting LUNs, a successful implementation should produce the following evidence: A planned loss of one shelf connection preserves storage availability and reports the failed path.

Incorrect Answers

A:

Validate adapter and port availability and approved configurations in the Hardware Universe design. That approach targets a different ONTAP condition: A proposed controller pair has inadequate supported ports for required host protocol and back-end shelf connectivity. At Boreal Foods, for production inventory files and reporting LUNs, the actual failure is: A new controller installation relies on a single shelf path and an accidental cable pull isolates disks. That alternative by itself would not prove the needed outcome: A planned loss of one shelf connection preserves storage availability and reports the failed path.

B:

Consult NetApp Hardware Universe and interoperability guidance before approving the controller and shelf combination. That approach targets a different ONTAP condition: A proposed ONTAP controller has no verified disk shelf compatibility for its target release and storage media. At Boreal Foods, for production inventory files and reporting LUNs, the actual failure is: A new controller installation relies on a single shelf path and an accidental cable pull isolates disks. That alternative by itself would not prove the needed outcome: A planned loss of one shelf connection preserves storage availability and reports the failed path.

D:

Validate the required HA interconnect wiring and peer health before exposing production workloads. That approach targets a different ONTAP condition: A dual-controller deployment has unverified HA interconnect cabling and reports takeover readiness as unknown. At Boreal Foods, for production inventory files and reporting LUNs, the actual failure is: A new controller installation relies on a single shelf path and an accidental cable pull isolates disks. That alternative by itself would not prove the needed outcome: A planned loss of one shelf connection preserves storage availability and reports the failed path.

Question 14

At Boreal Foods, the production environment supports production inventory files and reporting LUNs with separately managed development and production resources. Investigators find: A new controller installation relies on a single shelf path and an accidental cable pull isolates disks. The team reports that the correction is complete. Which observation BEST proves the stated problem is resolved?

  1. Every required host, cluster, management and shelf connection maps to an available supported port.
  2. ONTAP reports healthy HA partner communication and a supervised takeover readiness check completes.
  3. A planned loss of one shelf connection preserves storage availability and reports the failed path.
  4. The recorded platform bill of materials is supported for the intended ONTAP version and media type.

Explanation

Correct Answer

C:

A planned loss of one shelf connection preserves storage availability and reports the failed path. The observation verifies that the chosen action (Configure the recommended redundant SAS or supported storage shelf paths for that platform) has corrected the initiating failure (A new controller installation relies on a single shelf path and an accidental cable pull isolates disks). This is directly measurable for Boreal Foods's production inventory files and reporting LUNs rather than merely reporting task completion.

Incorrect Answers

A:

Every required host, cluster, management and shelf connection maps to an available supported port. This is a valid test for another condition (A proposed controller pair has inadequate supported ports for required host protocol and back-end shelf connectivity) after a different correction (Validate adapter and port availability and approved configurations in the Hardware Universe design). It does not establish the necessary result for Boreal Foods's production inventory files and reporting LUNs: A planned loss of one shelf connection preserves storage availability and reports the failed path.

B:

ONTAP reports healthy HA partner communication and a supervised takeover readiness check completes. This is a valid test for another condition (A dual-controller deployment has unverified HA interconnect cabling and reports takeover readiness as unknown) after a different correction (Validate the required HA interconnect wiring and peer health before exposing production workloads). It does not establish the necessary result for Boreal Foods's production inventory files and reporting LUNs: A planned loss of one shelf connection preserves storage availability and reports the failed path.

D:

The recorded platform bill of materials is supported for the intended ONTAP version and media type. This is a valid test for another condition (A proposed ONTAP controller has no verified disk shelf compatibility for its target release and storage media) after a different correction (Consult NetApp Hardware Universe and interoperability guidance before approving the controller and shelf combination). It does not establish the necessary result for Boreal Foods's production inventory files and reporting LUNs: A planned loss of one shelf connection preserves storage availability and reports the failed path.

Question 15

During a change readiness assessment at Evergreen Hospital, the storage reliability team find the following ONTAP problem: A new controller installation relies on a single shelf path and an accidental cable pull isolates disks. Which administrative action BEST addresses the specific problem?

  1. Consult NetApp Hardware Universe and interoperability guidance before approving the controller and shelf combination.
  2. Validate the required HA interconnect wiring and peer health before exposing production workloads.
  3. Validate adapter and port availability and approved configurations in the Hardware Universe design.
  4. Configure the recommended redundant SAS or supported storage shelf paths for that platform.

Explanation

Correct Answer

D:

Configure the recommended redundant SAS or supported storage shelf paths for that platform. This action addresses the specific failure: A new controller installation relies on a single shelf path and an accidental cable pull isolates disks. For Evergreen Hospital's virtual machine datastores and clinical files, a successful implementation should produce the following evidence: A planned loss of one shelf connection preserves storage availability and reports the failed path.

Incorrect Answers

A:

Consult NetApp Hardware Universe and interoperability guidance before approving the controller and shelf combination. That approach targets a different ONTAP condition: A proposed ONTAP controller has no verified disk shelf compatibility for its target release and storage media. At Evergreen Hospital, for virtual machine datastores and clinical files, the actual failure is: A new controller installation relies on a single shelf path and an accidental cable pull isolates disks. That alternative by itself would not prove the needed outcome: A planned loss of one shelf connection preserves storage availability and reports the failed path.

B:

Validate the required HA interconnect wiring and peer health before exposing production workloads. That approach targets a different ONTAP condition: A dual-controller deployment has unverified HA interconnect cabling and reports takeover readiness as unknown. At Evergreen Hospital, for virtual machine datastores and clinical files, the actual failure is: A new controller installation relies on a single shelf path and an accidental cable pull isolates disks. That alternative by itself would not prove the needed outcome: A planned loss of one shelf connection preserves storage availability and reports the failed path.

C:

Validate adapter and port availability and approved configurations in the Hardware Universe design. That approach targets a different ONTAP condition: A proposed controller pair has inadequate supported ports for required host protocol and back-end shelf connectivity. At Evergreen Hospital, for virtual machine datastores and clinical files, the actual failure is: A new controller installation relies on a single shelf path and an accidental cable pull isolates disks. That alternative by itself would not prove the needed outcome: A planned loss of one shelf connection preserves storage availability and reports the failed path.

Question 16

During a change readiness assessment at Evergreen Hospital, the storage reliability team find the following ONTAP problem: A new controller installation relies on a single shelf path and an accidental cable pull isolates disks. The team reports that the correction is complete. Which observation BEST proves the stated problem is resolved?

  1. A planned loss of one shelf connection preserves storage availability and reports the failed path.
  2. Every required host, cluster, management and shelf connection maps to an available supported port.
  3. ONTAP reports healthy HA partner communication and a supervised takeover readiness check completes.
  4. The recorded platform bill of materials is supported for the intended ONTAP version and media type.

Explanation

Correct Answer

A:

A planned loss of one shelf connection preserves storage availability and reports the failed path. The observation verifies that the chosen action (Configure the recommended redundant SAS or supported storage shelf paths for that platform) has corrected the initiating failure (A new controller installation relies on a single shelf path and an accidental cable pull isolates disks). This is directly measurable for Evergreen Hospital's virtual machine datastores and clinical files rather than merely reporting task completion.

Incorrect Answers

B:

Every required host, cluster, management and shelf connection maps to an available supported port. This is a valid test for another condition (A proposed controller pair has inadequate supported ports for required host protocol and back-end shelf connectivity) after a different correction (Validate adapter and port availability and approved configurations in the Hardware Universe design). It does not establish the necessary result for Evergreen Hospital's virtual machine datastores and clinical files: A planned loss of one shelf connection preserves storage availability and reports the failed path.

C:

ONTAP reports healthy HA partner communication and a supervised takeover readiness check completes. This is a valid test for another condition (A dual-controller deployment has unverified HA interconnect cabling and reports takeover readiness as unknown) after a different correction (Validate the required HA interconnect wiring and peer health before exposing production workloads). It does not establish the necessary result for Evergreen Hospital's virtual machine datastores and clinical files: A planned loss of one shelf connection preserves storage availability and reports the failed path.

D:

The recorded platform bill of materials is supported for the intended ONTAP version and media type. This is a valid test for another condition (A proposed ONTAP controller has no verified disk shelf compatibility for its target release and storage media) after a different correction (Consult NetApp Hardware Universe and interoperability guidance before approving the controller and shelf combination). It does not establish the necessary result for Evergreen Hospital's virtual machine datastores and clinical files: A planned loss of one shelf connection preserves storage availability and reports the failed path.

Question 17

Pinecrest Research manages scientific datasets and GPU project file shares under a documented recovery-time objective. A storage incident report states: A hardware replacement plan removes a failed disk without checking automatic reconstruction progress or matching spare availability. Which administrative action BEST addresses the specific problem?

  1. Size aggregate or local-tier usable storage using platform-specific RAID and reserve requirements.
  2. Confirm degraded RAID group status and compatible spare capacity before following the documented drive replacement workflow.
  3. Validate adapter and port availability and approved configurations in the Hardware Universe design.
  4. Consult NetApp Hardware Universe and interoperability guidance before approving the controller and shelf combination.

Explanation

Correct Answer

B:

Confirm degraded RAID group status and compatible spare capacity before following the documented drive replacement workflow. This action addresses the specific failure: A hardware replacement plan removes a failed disk without checking automatic reconstruction progress or matching spare availability. For Pinecrest Research's scientific datasets and GPU project file shares, a successful implementation should produce the following evidence: The new drive is recognized and the RAID group reconstruction completes without unresolved disk faults.

Incorrect Answers

A:

Size aggregate or local-tier usable storage using platform-specific RAID and reserve requirements. That approach targets a different ONTAP condition: A capacity calculation treats raw SSD labels as completely usable space and omits RAID, system reserves and spare overhead. At Pinecrest Research, for scientific datasets and GPU project file shares, the actual failure is: A hardware replacement plan removes a failed disk without checking automatic reconstruction progress or matching spare availability. That alternative by itself would not prove the needed outcome: The new drive is recognized and the RAID group reconstruction completes without unresolved disk faults.

C:

Validate adapter and port availability and approved configurations in the Hardware Universe design. That approach targets a different ONTAP condition: A proposed controller pair has inadequate supported ports for required host protocol and back-end shelf connectivity. At Pinecrest Research, for scientific datasets and GPU project file shares, the actual failure is: A hardware replacement plan removes a failed disk without checking automatic reconstruction progress or matching spare availability. That alternative by itself would not prove the needed outcome: The new drive is recognized and the RAID group reconstruction completes without unresolved disk faults.

D:

Consult NetApp Hardware Universe and interoperability guidance before approving the controller and shelf combination. That approach targets a different ONTAP condition: A proposed ONTAP controller has no verified disk shelf compatibility for its target release and storage media. At Pinecrest Research, for scientific datasets and GPU project file shares, the actual failure is: A hardware replacement plan removes a failed disk without checking automatic reconstruction progress or matching spare availability. That alternative by itself would not prove the needed outcome: The new drive is recognized and the RAID group reconstruction completes without unresolved disk faults.

Question 18

Pinecrest Research manages scientific datasets and GPU project file shares under a documented recovery-time objective. A storage incident report states: A hardware replacement plan removes a failed disk without checking automatic reconstruction progress or matching spare availability. The team reports that the correction is complete. Which observation BEST proves the stated problem is resolved?

  1. Every required host, cluster, management and shelf connection maps to an available supported port.
  2. The new drive is recognized and the RAID group reconstruction completes without unresolved disk faults.
  3. The planned host-facing capacity reconciles with the configured local-tier usable space after overhead.
  4. The recorded platform bill of materials is supported for the intended ONTAP version and media type.

Explanation

Correct Answer

B:

The new drive is recognized and the RAID group reconstruction completes without unresolved disk faults. The observation verifies that the chosen action (Confirm degraded RAID group status and compatible spare capacity before following the documented drive replacement workflow) has corrected the initiating failure (A hardware replacement plan removes a failed disk without checking automatic reconstruction progress or matching spare availability). This is directly measurable for Pinecrest Research's scientific datasets and GPU project file shares rather than merely reporting task completion.

Incorrect Answers

A:

Every required host, cluster, management and shelf connection maps to an available supported port. This is a valid test for another condition (A proposed controller pair has inadequate supported ports for required host protocol and back-end shelf connectivity) after a different correction (Validate adapter and port availability and approved configurations in the Hardware Universe design). It does not establish the necessary result for Pinecrest Research's scientific datasets and GPU project file shares: The new drive is recognized and the RAID group reconstruction completes without unresolved disk faults.

C:

The planned host-facing capacity reconciles with the configured local-tier usable space after overhead. This is a valid test for another condition (A capacity calculation treats raw SSD labels as completely usable space and omits RAID, system reserves and spare overhead) after a different correction (Size aggregate or local-tier usable storage using platform-specific RAID and reserve requirements). It does not establish the necessary result for Pinecrest Research's scientific datasets and GPU project file shares: The new drive is recognized and the RAID group reconstruction completes without unresolved disk faults.

D:

The recorded platform bill of materials is supported for the intended ONTAP version and media type. This is a valid test for another condition (A proposed ONTAP controller has no verified disk shelf compatibility for its target release and storage media) after a different correction (Consult NetApp Hardware Universe and interoperability guidance before approving the controller and shelf combination). It does not establish the necessary result for Pinecrest Research's scientific datasets and GPU project file shares: The new drive is recognized and the RAID group reconstruction completes without unresolved disk faults.

Question 19

For Willowbrook Education, a proposed storage change affects student registration databases and departmental files. The identified control failure is: A hardware replacement plan removes a failed disk without checking automatic reconstruction progress or matching spare availability. Which administrative action BEST addresses the specific problem?

  1. Confirm degraded RAID group status and compatible spare capacity before following the documented drive replacement workflow.
  2. Consult NetApp Hardware Universe and interoperability guidance before approving the controller and shelf combination.
  3. Size aggregate or local-tier usable storage using platform-specific RAID and reserve requirements.
  4. Validate adapter and port availability and approved configurations in the Hardware Universe design.

Explanation

Correct Answer

A:

Confirm degraded RAID group status and compatible spare capacity before following the documented drive replacement workflow. This action addresses the specific failure: A hardware replacement plan removes a failed disk without checking automatic reconstruction progress or matching spare availability. For Willowbrook Education's student registration databases and departmental files, a successful implementation should produce the following evidence: The new drive is recognized and the RAID group reconstruction completes without unresolved disk faults.

Incorrect Answers

B:

Consult NetApp Hardware Universe and interoperability guidance before approving the controller and shelf combination. That approach targets a different ONTAP condition: A proposed ONTAP controller has no verified disk shelf compatibility for its target release and storage media. At Willowbrook Education, for student registration databases and departmental files, the actual failure is: A hardware replacement plan removes a failed disk without checking automatic reconstruction progress or matching spare availability. That alternative by itself would not prove the needed outcome: The new drive is recognized and the RAID group reconstruction completes without unresolved disk faults.

C:

Size aggregate or local-tier usable storage using platform-specific RAID and reserve requirements. That approach targets a different ONTAP condition: A capacity calculation treats raw SSD labels as completely usable space and omits RAID, system reserves and spare overhead. At Willowbrook Education, for student registration databases and departmental files, the actual failure is: A hardware replacement plan removes a failed disk without checking automatic reconstruction progress or matching spare availability. That alternative by itself would not prove the needed outcome: The new drive is recognized and the RAID group reconstruction completes without unresolved disk faults.

D:

Validate adapter and port availability and approved configurations in the Hardware Universe design. That approach targets a different ONTAP condition: A proposed controller pair has inadequate supported ports for required host protocol and back-end shelf connectivity. At Willowbrook Education, for student registration databases and departmental files, the actual failure is: A hardware replacement plan removes a failed disk without checking automatic reconstruction progress or matching spare availability. That alternative by itself would not prove the needed outcome: The new drive is recognized and the RAID group reconstruction completes without unresolved disk faults.

Question 20

For Willowbrook Education, a proposed storage change affects student registration databases and departmental files. The identified control failure is: A hardware replacement plan removes a failed disk without checking automatic reconstruction progress or matching spare availability. The team reports that the correction is complete. Which observation BEST proves the stated problem is resolved?

  1. The new drive is recognized and the RAID group reconstruction completes without unresolved disk faults.
  2. The planned host-facing capacity reconciles with the configured local-tier usable space after overhead.
  3. Every required host, cluster, management and shelf connection maps to an available supported port.
  4. The recorded platform bill of materials is supported for the intended ONTAP version and media type.

Explanation

Correct Answer

A:

The new drive is recognized and the RAID group reconstruction completes without unresolved disk faults. The observation verifies that the chosen action (Confirm degraded RAID group status and compatible spare capacity before following the documented drive replacement workflow) has corrected the initiating failure (A hardware replacement plan removes a failed disk without checking automatic reconstruction progress or matching spare availability). This is directly measurable for Willowbrook Education's student registration databases and departmental files rather than merely reporting task completion.

Incorrect Answers

B:

The planned host-facing capacity reconciles with the configured local-tier usable space after overhead. This is a valid test for another condition (A capacity calculation treats raw SSD labels as completely usable space and omits RAID, system reserves and spare overhead) after a different correction (Size aggregate or local-tier usable storage using platform-specific RAID and reserve requirements). It does not establish the necessary result for Willowbrook Education's student registration databases and departmental files: The new drive is recognized and the RAID group reconstruction completes without unresolved disk faults.

C:

Every required host, cluster, management and shelf connection maps to an available supported port. This is a valid test for another condition (A proposed controller pair has inadequate supported ports for required host protocol and back-end shelf connectivity) after a different correction (Validate adapter and port availability and approved configurations in the Hardware Universe design). It does not establish the necessary result for Willowbrook Education's student registration databases and departmental files: The new drive is recognized and the RAID group reconstruction completes without unresolved disk faults.

D:

The recorded platform bill of materials is supported for the intended ONTAP version and media type. This is a valid test for another condition (A proposed ONTAP controller has no verified disk shelf compatibility for its target release and storage media) after a different correction (Consult NetApp Hardware Universe and interoperability guidance before approving the controller and shelf combination). It does not establish the necessary result for Willowbrook Education's student registration databases and departmental files: The new drive is recognized and the RAID group reconstruction completes without unresolved disk faults.

NetApp Certified Data Administrator, ONTAP (NS0-165) Practice Tests