Question 250
During a customer access escalation at Cedar City Utilities, the ONTAP administrators find the following ONTAP problem: A performance review assumes compression must always be disabled on AFF regardless of the hardware offload and ONTAP version. The team reports that the correction is complete. Which observation BEST proves the stated problem is resolved?
Explanation
Correct Answer
The chosen configuration retains supported efficiency behavior with measured CPU and latency evidence. The observation verifies that the chosen action (Verify platform-specific efficiency defaults and any hardware offload support before changing compression settings) has corrected the initiating failure (A performance review assumes compression must always be disabled on AFF regardless of the hardware offload and ONTAP version). This is directly measurable for Cedar City Utilities's meter telemetry archives and billing file shares rather than merely reporting task completion.
Incorrect Answers
A representative workload achieves acceptable latency with recorded physical space savings. This is a valid test for another condition (A mixed-media workload applies compression indiscriminately without testing CPU and latency impact on its actual access pattern) after a different correction (Select supported inline or postprocess compression settings based on platform and benchmark evidence). It does not establish the necessary result for Cedar City Utilities's meter telemetry archives and billing file shares: The chosen configuration retains supported efficiency behavior with measured CPU and latency evidence.
An audited capacity report reconciles physical blocks and logical consumption without double counting. This is a valid test for another condition (A storage report confuses logical provisioned space with physical written space and declares impossible capacity gains) after a different correction (Compare logical, used, and efficiency metrics from the correct volume and local-tier counters). It does not establish the necessary result for Cedar City Utilities's meter telemetry archives and billing file shares: The chosen configuration retains supported efficiency behavior with measured CPU and latency evidence.
A synthetic sparse/zero-filled dataset shows appropriate physical savings without altered logical reads. This is a valid test for another condition (An efficiency report claims all zero-filled blocks consume full physical space despite enabled zero-block deduplication) after a different correction (Validate deduplication and zero-block elimination using the relevant ONTAP efficiency counters). It does not establish the necessary result for Cedar City Utilities's meter telemetry archives and billing file shares: The chosen configuration retains supported efficiency behavior with measured CPU and latency evidence.