Question 460
During a critical plant maintenance window at Clearwater Apparel, an OT security engineer is rechecking the Fortinet-protected operational technology networks design. The issue observed is that a control-cell security design depends on one physical FortiGate appliance although its uptime objective requires continued processing after a gateway failure. The correction must preserve the recorded Purdue zone and conduit design. What should the plant add to its ongoing security review process?
Explanation
Correct Answer
Once the immediate issue is corrected, the ongoing safeguard is to test firewall and path failure domains with process engineers before claiming high availability. This control is warranted because redundant controller endpoints are ineffective if all required communications traverse a single gateway failure point. At Clearwater Apparel, it can be checked by confirming that a controlled gateway failure leaves allowed control telemetry available within the documented recovery tolerance.
Incorrect Answers
The proposed control addresses FortiNAC forced VLAN change for production devices, where network admission automation ignores fixed OT addressing and production communication constraints. At Clearwater Apparel, the relevant risk is that redundant controller endpoints are ineffective if all required communications traverse a single gateway failure point. The stated control does not address that recurring failure; test firewall and path failure domains with process engineers before claiming high availability.
That review targets a separate issue (Cert-based authentication with expired CA), where certificate-chain validation depends on correctly maintained authorized trust anchors. At Clearwater Apparel, the relevant risk is that redundant controller endpoints are ineffective if all required communications traverse a single gateway failure point. The stated control does not address that recurring failure; test firewall and path failure domains with process engineers before claiming high availability.
That practice applies to Unauthorized access to OT broadcast domain, where the temporary layer-two connection bypasses the expected access control and OT zone separation. At Clearwater Apparel, the relevant risk is that redundant controller endpoints are ineffective if all required communications traverse a single gateway failure point. The stated control does not address that recurring failure; test firewall and path failure domains with process engineers before claiming high availability.