Question 1
At Clearwater Apparel, an OT security team is reviewing Fortinet-protected operational technology networks during a remote engineering access review. The issue observed is that a plant keeps a single flat spreadsheet of devices without identifying which systems serve enterprise, operations, control, or safety functions. The correction must preserve the least-privilege engineering access contract. Which supported design or configuration change most directly corrects this OT-security issue?
Explanation
Correct Answer
The most relevant response for Clearwater Apparel is to inventory each asset with function, owner, Purdue level, required conduits, and permitted management path. The reason is that unclassified assets conceal the Purdue zone and conduit relationships needed for OT risk decisions. An OT acceptance check at Clearwater Apparel should establish that a sampled PLC, HMI, historian, and enterprise server each map to an approved zone with justified communications.
Incorrect Answers
That recommendation addresses a different problem (FortiGate passive device discovery gap), where an OT firewall sees controller traffic but the site asset view shows no associated industrial endpoints. In that case, device identification telemetry or permitted passive detection features are not configured or visible at the intended FortiGate boundary. The issue at Clearwater Apparel instead arises because unclassified assets conceal the Purdue zone and conduit relationships needed for OT risk decisions; the proposed step does not correct that specific mechanism.
The suggested change fits FortiNAC rogue device classification, where a new maintenance laptop is connected to a control switch yet remains treated as an approved engineering workstation. In that case, asset inventory and classification rules do not distinguish a newly observed endpoint from the authorized maintenance baseline. The issue at Clearwater Apparel instead arises because unclassified assets conceal the Purdue zone and conduit relationships needed for OT risk decisions; the proposed step does not correct that specific mechanism.
This would help with Unmanaged legacy PLC owner, where a controller appears in inventory with an IP address but no application owner or maintenance contact. In that case, technical fingerprints alone cannot establish accountable ownership and change approval for an OT asset. The issue at Clearwater Apparel instead arises because unclassified assets conceal the Purdue zone and conduit relationships needed for OT risk decisions; the proposed step does not correct that specific mechanism.