Question 720
At Brookside Manufacturing, the plant operations team is planning an industrial Ethernet modernization under a requirement for planned downtime and resilient cabling. After the switch change, operators must prove that they resolved: A managed FortiSwitch disappears from FortiGate topology after an installer moves its cable to a normal user access port. Which observation BEST demonstrates that the fix worked?
Explanation
Correct Answer
The correct serial-numbered switch reappears online in the managed inventory after reconnection. This observation verifies the specific reported problem, A managed FortiSwitch disappears from FortiGate topology after an installer moves its cable to a normal user access port. The intended correction was: Restore its uplink to the designated supported FortiLink port and verify discovery/control connectivity. It provides a directly testable outcome for the Brookside Manufacturing environment rather than treating a completed change ticket as proof.
Incorrect Answers
After physical remediation, error counters stabilize and FortiLink stays connected under load. For Brookside Manufacturing, that measurement would support a separate technical case: FortiLink intermittently disconnects and switch interface counters show repeated physical-layer errors. Its corresponding remedy is: Inspect port errors, link state and transceiver/cable compatibility before rewriting controller security policies. The reported Brookside Manufacturing condition is A managed FortiSwitch disappears from FortiGate topology after an installer moves its cable to a normal user access port. So the required outcome is: The correct serial-numbered switch reappears online in the managed inventory after reconnection.
The intended interface returns up and the switch controller can again communicate with its managed devices. For Brookside Manufacturing, that measurement would support a separate technical case: An outage ticket lists a FortiLink interface as down but no one checks whether the member port is administratively disabled. Its corresponding remedy is: Compare aggregate and physical member administrative and operational state before replacing FortiGate hardware. The reported Brookside Manufacturing condition is A managed FortiSwitch disappears from FortiGate topology after an installer moves its cable to a normal user access port. So the required outcome is: The correct serial-numbered switch reappears online in the managed inventory after reconnection.
The switch appears under the intended FortiGate with consistent policies and no simultaneous conflicting controller ownership. For Brookside Manufacturing, that measurement would support a separate technical case: A switch previously enrolled in standalone cloud management is expected to respond to a new FortiGate controller without mode migration. Its corresponding remedy is: Check the active management mode and perform a supported, backed-up transition before attempting FortiLink authorization. The reported Brookside Manufacturing condition is A managed FortiSwitch disappears from FortiGate topology after an installer moves its cable to a normal user access port. So the required outcome is: The correct serial-numbered switch reappears online in the managed inventory after reconnection.